R&S ZV-Z135 Calibration Kit Specifications

Similar documents
R&S ZV-Z3xx T-Checker Specifications

R&S RSC Step Attenuator Specifications

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

R&S ZVT Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications

R&S ZV-Z5x Calibration Units Specifications

R&S ZNB Vector Network Analyzer Specifications

Noise Figure Measurement Applications Specifications

R&S FS-K112PC NFC Measurement Software Specifications

R&S EB500 Monitoring Receiver Specifications

R&S ZVT Vector Network Analyzer Specifications

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ZV-Z5x Calibration Units Specifications

Analog Modulation Analysis (AM/FM/φM) Specifications

R&S FU129 Antenna Filter Unit Antenna switching, rotator control and signal attenuation, amplification and filtering

Power Added Efficiency Measurement with R&S ZNB/ R&S ZVA

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

R&S ZVA-Zxx Millimeter-Wave Converters Network analysis up to 500 GHz

Attenuators and Matching Pads, Terminations 75 mw to 1000 W, DC to 18 GHz

Noise Figure Measurement in the 60 GHz Range Application Note

R&S CMU-Z10/-Z11 Antenna Coupler/ RF Shielding Cover Simple interference-free testing of all mobiles

R&S ZVL Vector Network Analyzer Specifications

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

R&S FSC Spectrum Analyzer Specifications

Data Sheet Version R&S RT-ZVCxx Multi-Channel Power Probe Specifications

Vector Network Analyzers ZVB

LabWindows/CVI, VXIpnp driver history for the R&S Radio Tester

R&S ZNA Vector Network Analyzer Specifications

R&S SMC100A Signal Generator Specifications

R&S FPC Spectrum Analyzer Specifications

R&S ESRP EMI Test Receiver Specifications

R&S ESCI/ESCI7 EMI Test Receiver Specifications

Guide Version Five techniques for fast, accurate power integrity measurements

R&S NRP USB and LAN Power Sensors Specifications

R&S TS-PSAM Analog Source and Measurement Module Scanning multimeter and data acquisition unit

R&S FSWP Phase Noise Analyzer Specifications

R&S FSH4/8 Spectrum Analyzer Specifications

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

R&S NRPC Calibration Kits Calibration of power sensors

R&S FSWP Phase Noise Analyzer Specifications

R&S NRP-Zxx Power Sensors Specifications

R&S SMZ Frequency Multiplier Precise andadjustable output levels from 50 GHz to 110 GHz

R&S NRP Power Meter Family Specifications

R&S TS8997 Regulatory Test System for Wireless Devices

ENY81 Coupling Network

Measurement Setup for Phase Noise Test at Frequencies above 50 GHz Application Note

Bring satellites into your lab: GNSS simulators from the T&M expert.

Receiver requirements for a TDOA-based radiolocation system

MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

Evolution of the Modern Receiver in a Crowded Spectrum Environment White Paper

R&S TS-EMF EMF Measurement System Easy, frequency-selective measurement of EMF emissions

R&S ZVH Cable and Antenna Analyzer Specifications

R&S ZVH Cable and Antenna Analyzer Specifications

Modulation Accuracy Measurements of DVB-S2 and DVB-S2X Signals Application Note

R&S NRPC Calibration Kits Calibration of power sensors

R&S ESR EMI Test Receiver Specifications

R&S FSV Signal and Spectrum Analyzer Specifications

R&S MNT100 RF Interference Locator Specifications

R&S FSx-K91/-K91n, R&S FSW/FSQ-K91ac WLAN Application Firmware WLAN TX measurements with Rohde & Schwarz analyzers

Complimentary Reference Material

R&S CLGD DOCSIS Cable Load Generator Multichannel signal generator for DOCSIS 3.1 downstream and upstream

R&S TSMW, TSME, TSMA LTE Downlink Allocation Analysis Application Note

Voltage Sensors URV5-Z

Technical Information

Bring satellites into your lab

R&S UMS175 Compact Radiomonitoring System High performance for outdoor deployment

R&S FSV Signal Analyzer Specifications

R&S ESRP EMI Test Receiver Specifications

R&S UPP Audio Analyzer Specifications

R&S NRP USB and LAN Power Sensors Specifications

R&S ZVH Cable and Antenna Analyzer Where mobility counts

R&S SMB100N SIGNAL GENERATOR

Provided by R&S FSH4/FSH8 Spectrum Analyzer Specifications

R&S SMA100A Signal Generator The new standard of excellence in the analog signal generator class

R&S ZVH Cable and Antenna Analyzer For more efficiency in the field

R&S FSUP Signal Source Analyzer Specifications

Technical Information

Application Firmware for Phase Noise Measurements FS-K40

HO118 Binning Interface User Manual * * Version 02. User Manual. Test & Measurement

Spectrum Analyzer FSL

Group Delay measurements with Signal and Spectrum Analyzers Application Note

Signal Generator SMA 100A

R&S FSH Handheld Spectrum Analyzer Where mobility counts

Using Harmonic External Mixers To Extend the Frequency Range Application Note

R&S OSP Open Switch and Control Platform Specifications

R&S DF-ATC-S ATC DF System Solution Accurate and reliable direction finding for civil and military air traffic control

R&S ETH Handheld TV Analyzer Specifications

HF Transmit/Receive Broadband System XB 2900

R&S OSP Open Switch and Control Platform Specifications

R&S SMB100A RF and Microwave Signal Generator Versatile, compact, up to 40 GHz; 170 GHz with upconverter

R&S Spectrum Rider FPH Handheld Spectrum Analyzer Specifications

R&S EM510 HF Digital Wideband Receiver Efficient and versatile solution for radiomonitoring

MILnews. IP-based split-site operation with the R&S M3SR Series4100 HF radios. Offprint from MILnews 12. Electronics for security and defense

Automated Measurements of 77 GHz FMCW Radar Signals

R&S NRP USB and LAN Power Sensors Specifications

R&S ZVAX TRM Extension Unit Configurable signal conditioning for measurements on active components

RF Signal Generator SM300

R&S MNT100 RF Interference Locator

Signal Generator SML

Transcription:

R&S ZV-Z135 Calibration Kit Specifications Test & Measurement Data Sheet 01.01

CONTENTS Definitions... 3 Specifications... 4 Mechanical data... 4 Electrical data of R&S ZV-Z135 (3.5 mm, female)... 4 Electrical data of R&S ZV-Z135 (3.5 mm, male)... 5 General data... 6 Ordering information... 7 2 Rohde & Schwarz R&S ZV-Z135 Calibration Kits

Definitions General Product data applies under the following conditions: Three hours storage at ambient temperature followed by 30 minutes warm-up operation Specified environmental conditions met Recommended calibration interval adhered to All internal automatic adjustments performed, if applicable Specifications with limits Represent warranted product performance by means of a range of values for the specified parameter. These specifications are marked with limiting symbols such as <,, >,, ±, or descriptions such as maximum, limit of, minimum. Compliance is ensured by testing or is derived from the design. Test limits are narrowed by guard bands to take into account measurement uncertainties, drift and aging, if applicable. Specifications without limits Represent warranted product performance for the specified parameter. These specifications are not specially marked and represent values with no or negligible deviations from the given value (e.g. dimensions or resolution of a setting parameter). Compliance is ensured by design. Typical data (typ.) Characterizes product performance by means of representative information for the given parameter. When marked with <, > or as a range, it represents the performance met by approximately 80 % of the instruments at production time. Otherwise, it represents the mean value. Nominal values (nom.) Characterize product performance by means of a representative value for the given parameter (e.g. nominal impedance). In contrast to typical data, a statistical evaluation does not take place and the parameter is not tested during production. Measured values (meas.) Characterize expected product performance by means of measurement results gained from individual samples. Uncertainties Represent limits of measurement uncertainty for a given measurand. Uncertainty is defined with a coverage factor of 2 and has been calculated in line with the rules of the Guide to the Expression of Uncertainty in Measurement (GUM), taking into account environmental conditions, aging, wear and tear. Device settings and GUI parameters are designated with the format parameter: value. Typical data as well as nominal and measured values are not warranted by Rohde & Schwarz. Rohde & Schwarz R&S ZV-Z135 Calibration Kits 3

Specifications Mechanical data Connector type R&S ZV-Z135 model.02 3.5 mm, male R&S ZV-Z135 model.03 3.5 mm, female Gauge R&S ZV-Z135 model.02 0 mm to 0.076 mm R&S ZV-Z135 model.03 0 mm to 0.076 mm Inner conductor material Au-plated age-hardened CuBe alloy Outer conductor material CuSnZn-plated Cu alloy Body blue anodized Al Electrical data of R&S ZV-Z135 (3.5 mm, female) Frequency range 0 Hz to 15 GHz Through standard Return loss 0 Hz to 4 GHz typ. 36 db 4 GHz to 8 GHz typ. 30 db 8 GHz to 13 GHz typ. 27 db 13 GHz to 15 GHz typ. 25 db Insertion loss typ. 0.02 db f/ghz Electrical length typ. 38.25 mm Open standard Fringing capacitance C 0 7.425 ff C 1 2.47 ff/ghz C 2 0.226 ff/ghz 2 C 3 0.00618 ff/ghz 3 Offset length 9.24 mm Loss typ. 0.01 db f/ghz Short standard Inductance L 0 27.98 ph L 1 5.01 ph/ghz L 2 0.3038 ph/ghz 2 L 3 0.00613 ph/ghz 3 Offset length 9.2 mm Loss typ. 0.01 db f/ghz Match standard DC resistance 50.0 Ω ± 0.5 Ω Return loss 0 Hz to 4 GHz typ. 42 db 4 GHz to 8 GHz typ. 37 db 8 GHz to 13 GHz typ. 30 db 13 GHz to 15 GHz typ. 24 db Maximum input power 0.5 W Effective system data Directivity 0 Hz to 4 GHz > 41 db 4 GHz to 8 GHz > 38 db 8 GHz to 13 GHz > 29 db 13 GHz to 15 GHz > 23 db Source match 0 Hz to 4 GHz > 36 db 4 GHz to 8 GHz > 31 db 8 GHz to 13 GHz > 26 db 13 GHz to 15 GHz > 20 db Reflection tracking 0 Hz to 4 GHz < 0.025 db 4 GHz to 8 GHz < 0.03 db 8 GHz to 13 GHz < 0.04 db 13 GHz to 15 GHz < 0.05 db Load match 0 Hz to 4 GHz > 39 db 4 GHz to 8 GHz > 35 db 8 GHz to 13 GHz > 27 db 13 GHz to 15 GHz > 21 db Transmission tracking 0 Hz to 4 GHz < 0.05 db 4 GHz to 8 GHz < 0.10 db 8 GHz to 13 GHz < 0.20 db 13 GHz to 15 GHz < 0.40 db 4 Rohde & Schwarz R&S ZV-Z135 Calibration Kits

Electrical data of R&S ZV-Z135 (3.5 mm, male) Frequency range 0 Hz to 15 GHz Through standard Return loss 0 Hz to 4 GHz typ. 36 db 4 GHz to 8 GHz typ. 30 db 8 GHz to 13 GHz typ. 27 db 13 GHz to 15 GHz typ. 25 db Insertion loss typ. 0.02 db f/ghz Electrical length typ. 38.25 mm Open standard Fringing capacitance C 0 3.434 ff C 1 0.3752 ff/ghz C 2 0.000676 ff/ghz 2 C 3 0.000725 ff/ghz 3 Offset length 9.24 mm Loss 0.01 db f/ghz Short standard Inductance L 0 22.44 ph L 1 4.568 ph/ghz L 2 0.2909 ph/ghz 2 L 3 0.00516 ph/ghz 3 Offset length 9.217 mm Loss 0.015 db f/ghz Match standard DC resistance 50.0 Ω ± 0.5 Ω Return loss 0 Hz to 4 GHz typ. 42 db 4 GHz to 8 GHz typ. 37 db 8 GHz to 13 GHz typ. 30 db 13 GHz to 15 GHz typ. 24 db Maximum input power 0.5 W Effective system data Directivity 0 Hz to 4 GHz > 41 db 4 GHz to 8 GHz > 38 db 8 GHz to 13 GHz > 29 db 13 GHz to 15 GHz > 23 db Source match 0 Hz to 4 GHz > 36 db 4 GHz to 8 GHz > 31 db 8 GHz to 13 GHz > 26 db 13 GHz to 15 GHz > 20 db Reflection tracking 0 Hz to 4 GHz < 0.025 db 4 GHz to 8 GHz < 0.03 db 8 GHz to 13 GHz < 0.04 db 13 GHz to 15 GHz < 0.05 db Load match 0 Hz to 4 GHz > 39 db 4 GHz to 8 GHz > 35 db 8 GHz to 13 GHz > 27 db 13 GHz to 15 GHz > 21 db Transmission tracking 0 Hz to 4 GHz < 0.05 db 4 GHz to 8 GHz < 0.10 db 8 GHz to 13 GHz < 0.20 db 13 GHz to 15 GHz < 0.40 db Rohde & Schwarz R&S ZV-Z135 Calibration Kits 5

General data Temperature loading operating temperature range +18 C to +28 C permissible temperature range +5 C to +40 C storage temperature range 40 C to +70 C, in line with EN 60068-2- 1 and EN 60068-2-2 Standards R&S ZV-Z135 IEC 60169-23 Recommended calibration interval 1 year Dimensions (W H D) R&S ZV-Z135 model.02 65 mm 22 mm 90 mm, (2.6 in 0.9 in 3.6 in) Dimensions (W H D) R&S ZV-Z135 model.03 74 mm 22 mm 95 mm, (2.9 in 0.9 in 3.7 in) Weight R&S ZV-Z135 225 g (0.5 lb) Shipping weight 1 kg (2.2 lb) 6 Rohde & Schwarz R&S ZV-Z135 Calibration Kits

Ordering information Designation Type Order No. Calibration Kit (3.5 mm, male) R&S ZV-Z135 1317.7677.02 Calibration Kit (3.5 mm, female) R&S ZV-Z135 1317.7677.03 Rohde & Schwarz R&S ZV-Z135 Calibration Kits 7

Service you can rely on J Worldwide J Local and personalized J Customized and flexible J Uncompromising quality J Long-term dependability About Rohde & Schwarz Rohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solutions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure communications. Established more than 75 years ago, Rohde & Schwarz has a global presence and a dedicated service network in over 70 countries. Company headquarters are in Munich, Germany. Environmental commitment Energy-efficient products Continuous improvement in environmental sustainability ISO 14001-certified environmental management system Certified Quality System ISO 9001 Rohde & Schwarz GmbH & Co. KG www.rohde-schwarz.com Regional contact Europe, Africa, Middle East +49 89 4129 12345 customersupport@rohde-schwarz.com North America 1 888 TEST RSA (1 888 837 87 72) customer.support@rsa.rohde-schwarz.com Latin America +1 410 910 79 88 customersupport.la@rohde-schwarz.com Asia/Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China +86 800 810 8228/+86 400 650 5896 customersupport.china@rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners Printed in Germany (as) PD 3606.6828.22 Version 01.01 March 2012 R&S ZV-Z135 Subject to change 2012 Rohde & Schwarz GmbH & Co. KG 81671 München, Germany 3606682822