Neutron Engineering Inc.

Similar documents
Neutron Engineering Inc.

VERIFICATION. Report No.: NEI-FCCE A Issued Date: Jul. 15, 2013

FCC Test Report FCC ID: XN6-SB3651E6

FCC Part 15B TEST REPORT

FCC Part 15C Test Report

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

C E R T I F I C A T I O N

FCC Test Report FCC ID: 2ADMQ-18867

Test Report. Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3

C E R T I F I C A T I O N

FCC RADIO TEST REPORT FCC ID: A25-TX012

TEST REPORT. Table of Contents

FCC 47 CFR PART 15 SUBPART B

FCC 15B Test Report. : Bluetooth 4.2 Dual Mode USB HCI Module (Refer to item for more details) (Refer to item for more details)

FCC Part 15C Test Report FCC ID: 2AK8V-WF8300

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

FCC/IC Test Report. : 2AOIMOMATA1 Equipment authorization required : SDoC IC ID

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

FCC CLASS B COMPLIANCE REPORT (DOC)

FCC Part 15C Test Report FCC ID: 2AFKNE100W

FCC DoC TEST REPORT. TESTED : Sep. 01 to 02, 2010 APPLICANT : LOGITECH FAR EAST LTD.

Declaration of Conformity (DoC)

FCC RADIO TEST REPORT FCC ID: 2ACNAKBT10

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

TEST REPORT. Table of Contents

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

FCC Part 15C Test Report FCC ID: 2ANYRCBAR-25

FCC TEST REPORT. according to. 47 CFR FCC Rules and Regulations Part 15 Subpart B, Class B Digital Device. Equipment : IPC Bare Bone System

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

T A B L E O F C O N T E N T S DESCRIPTION PAGE

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

RADIO TEST REPORT. Report No: STS F01. Issued for KINGFISH ELECTRONICS CO., LIMITED. Bluetooth headset

FCC TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

QI HARDWARE INC. Ben NanoNote. Model: Ben NanoNote September Report No.: (This report supersedes NONE)

TEST REPORT. The submitted sample of the above equipment has been tested for according to the requirements of the following standards:

Test Report. Product Name : Access Point Model No.: MS-6809 FCC ID.: I4L-MS6809

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

FCC 15B Test Report. : ac/a/b/g/n + Bluetooth 4.2 module (please refer to section for more details.)

FCC 47 CFR PART 15 SUBPART B CERTIFICATION TEST REPORT FOR a/b/g/n/ac 3X3 WLAN + Bluetooth Combo PCI-E Mini Card MODEL NUMBER: BCM94360CS

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

TEST REPORT. Issued for:

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

RADIO TEST REPORT. Report No: STS W02. Issued for. OBDSTAR Technology Co., Ltd. Key Master DP PLUS N/A DP80 2AJ2DDP80

FCC 47 CFR PART 15 SUBPART B TEST REPORT

FCC Part 15C Test Report FCC ID: 2ALQA-LIVE

FCC TEST REPORT. for. 47 CFR, Part 15, Subpart C. SPORTON International Inc.

FCC 47 CFR PART 15 SUBPART B TEST REPORT

FCC DOC TEST REPORT. According to. 47 CFR, Part 2, Part 15, CISPR PUB. 22, ICES 003 Issue 6

FCC TEST REPORT. for. 47 CFR, Part 2, Part 15 Subpart B and CISPR PUB. 22. SPORTON International Inc.

TEST REPORT. Table of Contents

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR DUAL RADIO OUTDOOR ACCESS POINT MODEL NUMBER: AP-ONE FCC ID: SWX-AP1R2

ENGINEERING TEST REPORT

TRANSMITTER MODEL: KAS-2030M

FCC TEST REPORT Authorized under Declaration of Conformity

FCC Part 15 Subpart B

FCC Verification TEST REPORT

FCC 15B Test Report. : Bluetooth 4.2 module (BLE only) (Refer to item for more details)

FCC C2PC Test Report

Test Report. Product Name : IPC Model No.

FCC Test Report FCC ID: 2ADWUPSPCL20A0

FCC RADIO TEST REPORT FCC ID: 2ABH3FOD43TA-BL

EMI Test Report. : BTv4.0 Dual Mode USB Dongle

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above.

FCC CLASS B COMPLIANCE REPORT (DoC)

Report No R-RFUSP28V01. FCC Test Report. Applicant Fluidmesh Networks, LLC Barlcay Blvd.,Buffalo Grove, IL USA

Test Report. Product Name : b P3 Wireless LAN PCMCIA Card Model No. : WN-110 FCC ID : QDWWN110

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed

VCCI TEST REPORT. TESTED : June 22 to 23, 2010 APPLICANT : LOGITECH FAR EAST LTD.

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

IST EMC LAB. EMISSION TEST REPORT. : DSP-4284GM Basic Alternate. : PDP(Plasma Display Panel) : Daewoo Electronics Corp. : Daewoo Electronics Corp.

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

FCC 47 CFR PART 15 SUBPART B TEST REPORT. For. External USB 2.0 HDD Enclosure

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR THE FUEL WEB, INC. GATEWAY MODULE MODEL: GWM-P-SHRF-1 FCC ID: PX5-GWM1001

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

TEST REPORT Title 47-Telecommunication

Gestek GESTEK Gestek

ORT. MobiWire. Brand. Product. Dakota. Model. Report No. April 22, Issue. TA Technology

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

FCC RADIO TEST REPORT FCC ID: 2ABH3FOD43TA-BL

TEST REPORT FCC ID: 2ADMF-HC06. : bluetooth module keyes HC-06, keyes hc-05, FUNDUINO HC-06, FUNDUINO hc-05

Matric Limited Hill City Road R.R. #1 Box 421A Seneca, PA 16346

FCC TEST REPORT. according to. 47 CFR FCC Rules and Regulations Part 15 Subpart B, Class A Digital Device

ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT

FCC RADIO TEST REPORT FCC ID: 2AML6BB898

Table of Contents Page Total Page 7 1. General Information

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

EMI Test Report. W66N220 Commerce Court, Cedarburg, Wisconsin 53012, USA : CISPR 32:2015/COR1:2016, Class B AS/NZS CISPR 32:2015, Class B

FCC TEST REPORT Authorized under Declaration of Conformity

Transcription:

Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences or generalizations drawn by the client or others from Neutron issued reports. Neutron s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron s authorized written approval. Neutron s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: NEI-FCCE-1- Page 2 of 26

Table of Contents Page 1. CERTIFICATION 4 2. SUMMARY OF TEST RESULTS 5 2.1 TEST FACILITY 6 2.2 MEASUREMENT UNCERTAINTY 6 3. GENERAL INFORMATION 7 3.1 GENERAL DESCRIPTION OF EUT 7 3.2 DESCRIPTION OF TEST MODES 8 3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 9 3.4 DESCRIPTION OF SUPPORT UNITS 10 4. EMC EMISSION TEST 11 4.1 CONDUCTED EMISSION MEASUREMENT 11 4.1.1 POWER LINE CONDUCTED EMISSION 11 4.1.2 MEASUREMENT INSTRUMENTS LIST 11 4.1.3 TEST PROCEDURE 12 4.1.4 DEVIATION FROM TEST STANDARD 12 4.1.5 TEST SETUP 12 4.1.6 BLOCK DIAGRAM OF TEST SETUP 13 4.1.7 EUT OPERATING CONDITIONS 13 4.1.8 TEST RESULTS 14 4.2 RADIATED EMISSION MEASUREMENT 18 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT 18 4.2.2 MEASUREMENT INSTRUMENTS LIST 19 4.2.3 TEST PROCEDURE 19 4.2.4 DEVIATION FROM TEST STANDARD 19 4.2.5 TEST SETUP 20 4.2.6 BLOCK DIAGRAM OF TEST SETUP 20 4.2.7 EUT OPERATING CONDITIONS 20 4.2.8 TEST RESULTS 21 5. EUT TEST PHOTO 25 Report No.: NEI-FCCE-1- Page 3 of 26

1. CERTIFICATION E q u i p m e n t : Speaker System Z320 Brand Name : Logitech Model Name : S-00079 A p p l i c a n t : GUOGUANG ELECTRIC Co.,Ltd F a c t o r y : GUOGUANG ELECTRIC Co.,Ltd Address : No.8 Jinghu Road, Xinhua Town, Huadu Reg.Guangzhou,510800 Date of Test : Jun. 15, 2009 ~ Jun. 19, 2009 Standards : FCC Part 15, Subpart B, Class B CISPR 22: 1997+A1: 2000, Class B ICES-003: 2004, Class B ANSI C63.4-2003 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCE-1-) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality assessment standard and technical standard(s). Report No.: NEI-FCCE-1- Page 4 of 26

2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: EMC Emission Standard Test Item Limit Judgment Remark FCC Part15, Subpart B Conducted Emission Class B PASS CISPR 22:1997+A1: 2000 ICES-003: 2004 Radiated Emission Class B PASS NOTE: (1) N/A denotes test is not applicable in this Test Report. Report No.: NEI-FCCE-1- Page 5 of 26

2.1 TEST FACILITY The test facilities used to collect the test data in this report is C01/OS02 at the location of No.132-1, Lane 329, Sec. 2, Palain Road, Shijr City, Taipei, Taiwan. 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95% A. Conducted Measurement : Test Site Method Measurement Frequency Range U,(dB) NOTE C01 ANSI 150 KHz ~ 30MHz 1.94 B. Radiated Measurement : Test Site OS-01 OS-02 Method ANSI ANSI Measurement Frequency Ant. Range H / V U,(dB) NOTE 30MHz ~ 200MHz V 3.82 30MHz ~ 200MHz H 3.60 200MHz ~ 1,000MHz V 3.86 200MHz ~ 1,000MHz H 3.94 30MHz ~ 200MHz V 2.48 30MHz ~ 200MHz H 2.16 200MHz ~ 1,000MHz V 2.50 200MHz ~ 1,000MHz H 2.66 Report No.: NEI-FCCE-1- Page 6 of 26

3. GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT Equipment Speaker System Z320 Brand Name Logitech Model Name S-00079 OEM Brand/Model Name N/A Compared with previous report (NEI-FCCE-1-0902C039), Model Difference model differences are resistors, diodes and capacitors changed. The EUT is a Speaker System Z320. Based on the application, features, or specification Product Description exhibited in User's Manual, the EUT is considered as an ITE/Computing Device. More details of EUT technical specification, please refer to the User's Manual. Power Source DC Voltage supplied from AC/DC adapter. (1) Adapter(Brand/Model: Logitech/S018BU1600112) AC I/P 100-240V~ 50/60Hz 500mA DC O/P 16.0V 1120mA Power Rating (2) Adapter(Brand/Model: Logitech/EFS01801600112UL) AC I/P 100-240V~ 50/60Hz 0.4A DC O/P 16V 1.12A Connecting I/O Port(s) Please refer to the User's Manual Products Covered N/A Note: 1. For a more detailed features description, please refer to the manufacturer s specifications or the User's Manual. Report No.: NEI-FCCE-1- Page 7 of 26

3.2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generated from EUT, the test system was pre-scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level. Each of these EUT operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively. Pretest Mode Mode 1 Description AUDIO IN The EUT system operated these modes were found to be the worst case during the pre-scanning test as Following: For Conducted / Radiated Test Final Test Mode Mode 1 Description AUDIO IN Report No.: NEI-FCCE-1- Page 8 of 26

3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED C-5 C-3 C-4 C-6 C-7 E-5 LCD Monitor E-2 PC E-1 EUT E-1-1 EUT E-4 Printer E-3 Modem C-2 C-1 E-7 Keyboard E-6 Mouse C-1 USB Cable C-2 USB Cable C-3 D-Sub Cable C-4 Parallel Cable C-5 RS232 Cable C-6 Audio Cable C-7 Audio Cable Report No.: NEI-FCCE-1- Page 9 of 26

3.3 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item Equipment Mfr/Brand Model/Type No. FCC ID Series No. Note Speaker E-1 System Z320 Speaker E-1-1 System Z320 Logitech S-00079 DOC N/A EUT Logitech S-00079 DOC N/A EUT E-2 PC HP Dx7400 DOC CNG7430PWL E-3 Modem ACEEX DM-1414V IFAXDm1414 0603002131 E-4 Printer SII DPU-414 DOC 3018507 B E-5 LCD monitor Dell E177FPc DOC CNOFJ179-64180-6A G-1WNS E-6 USB Mouse Dell MO56UOA DOC G01003HO E-7 USB Keyboard Dell L100 DOC CNORH6596589085 C00U7 Item Shielded Type Ferrite Core Length Note C-1 YES NO 1.8M C-2 YES YES 1.6M C-3 YES YES 1.5M C-4 YES NO 1.8M C-5 YES NO 1.8M C-6 YES NO 1.8M C-7 NO NO 1.7M Note: (1) The support equipment was authorized by Declaration of Conformity. (2) For detachable type I/O cable should be specified the length in m in Length column. Report No.: NEI-FCCE-1- Page 10 of 26

4. EMC EMISSION TEST 4.1 CONDUCTED EMISSION MEASUREMENT 4.1.1 POWER LINE CONDUCTED EMISSION (FREQUENCY RANGE 150KHZ-30MHZ) FREQUENCY (MHz) Class A (dbuv) Class B (dbuv) Quasi-peak Average Quasi-peak Average 0.15-0.5 79.00 66.00 66 56 * 56 46 * 0.50-5.0 73.00 60.00 56.00 46.00 5.0-30.0 73.00 60.00 60.00 50.00 Note: (1) The tighter limit applies at the band edges. (2) The limit of * marked band means the limitation decreases linearly with the logarithm of the frequency in the range. 4.1.2 MEASUREMENT INSTRUMENTS LIST Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until 1 Test Cable N/A SR03_C_01 &02 N/A Oct. 09, 2009 2 LISN EMCO 3816/2 00042991 Jan. 28, 2010 3 Pulse Limiter Electro-Metrics EM-7600 112644 Nov. 26, 2009 4 50Ω Terminator N/A N/A N/A May. 12, 2010 5 EMI Test Receiver R&S ESCI 100080 Mar. 09, 2010 6 LISN EMCO 4825/2 00028234 Dec. 29, 2009 Remark: N/A denotes No Model Name, Serial No. or No Calibration specified. Report No.: NEI-FCCE-1- Page 11 of 26

4.1.3 TEST PROCEDURE a. The EUT was placed 0.4 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long. c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item EUT Test Photos. 4.1.4 DEVIATION FROM TEST STANDARD No deviation 4.1.5 TEST SETUP Vertical Reference Ground Plane 40 cm EUT Test Receiver 80 cm LISN Horizontal Reference Ground Plane Report No.: NEI-FCCE-1- Page 12 of 26

4.1.6 BLOCK DIAGRAM OF TEST SETUP AC Mains Test Receiver L.I.S.N.#1 Audio Cable EUT-1 Adapter EUT Audio Cable PC USB Cable USB Cable Mouse Keyboard AC Mains L.I.S.N.#2 D-Sub Cable LCD Monitor Parallel Cable Printer RS232 Cable Modem 4.1.7 EUT OPERATING CONDITIONS The EUT exercise program used during radiated and/or conducted emission measurement was designed to exercise the various system components in a manner similar to a typical use. The program contained on a PC hard disk and is auto-starting on power-up. Once loaded, the program sequentially exercises each system component in turn. The sequence used is: 1. Read (write) from (to) mass storage device (Flash Disk). 2. Send " H " pattern to video port device (Monitor). 3. Send " H " pattern to parallel port device (Printer). 4. Send " H " pattern to serial port device (Modem). 5. PC send 1kHz voice to EUT 6. Repeated from 2 to 5 continuously. As the keyboard and mouse are strictly input devices, no data is transmitted to (from) them during test. They are, however, continuously scanned for data input activity. Report No.: NEI-FCCE-1- Page 13 of 26

4.1.8 TEST RESULTS E.U.T : Speaker System Z320 Model Name : S-00079 Temperature : 29 C Relative Humidity : 51 % Pressure : 1010 hpa Test Voltage : AC 120V/60Hz Test Mode : AUDIO IN(Adapter Model: S018BU1600112) Freq. Terminal Measured(dBuV) Limits(dBuV) Margin (MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (db) Note 0.15 Line 55.64 34.24 66.00 56.00-10.36 (QP) 0.22 Line 50.19 * 62.74 52.74-12.55 (QP) 0.26 Line 46.38 * 61.50 51.50-15.12 (QP) 0.65 Line 38.44 * 56.00 46.00-17.56 (QP) 1.47 Line 33.94 * 56.00 46.00-22.06 (QP) 9.51 Line 37.77 * 60.00 50.00-22.23 (QP) Remark (1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./mhz Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./mhz (2) All readings are QP Mode value unless otherwise stated AVG in column of Note. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured, but AVG Mode didn t perform In this case, a * marked in AVG Mode column of Interference Voltage Measured (3) Measuring frequency range from 150KHz to 30MHz Report No.: NEI-FCCE-1- Page 14 of 26

E.U.T : Speaker System Z320 Model Name : S-00079 Temperature : 29 C Relative Humidity : 51 % Pressure : 1010 hpa Test Voltage : AC 120V/60Hz Test Mode : AUDIO IN(Adapter Model: S018BU1600112) Freq. Terminal Measured(dBuV) Limits(dBuV) Margin (MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (db) Note 0.15 Neutral 56.19 36.23 66.00 56.00-9.81 (QP) 0.20 Neutral 50.78 * 63.45 53.45-12.67 (QP) 0.29 Neutral 43.97 * 60.67 50.67-16.70 (QP) 0.37 Neutral 40.61 * 58.59 48.59-17.98 (QP) 3.08 Neutral 35.73 * 56.00 46.00-20.27 (QP) 6.15 Neutral 34.89 * 60.00 50.00-25.11 (QP) Remark (1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./mhz Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./mhz (2) All readings are QP Mode value unless otherwise stated AVG in column of Note. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured, but AVG Mode didn t perform In this case, a * marked in AVG Mode column of Interference Voltage Measured (3) Measuring frequency range from 150KHz to 30MHz Report No.: NEI-FCCE-1- Page 15 of 26

E.U.T : Speaker System Z320 Model Name : S-00079 Temperature : 29 C Relative Humidity : 51 % Pressure : 1010 hpa Test Voltage : AC 120V/60Hz Test Mode : AUDIO IN(Adapter Model: EFS01801600112UL) Freq. Terminal Measured(dBuV) Limits(dBuV) Margin (MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (db) Note 0.15 Line 50.28 * 66.00 56.00-15.72 (QP) 0.21 Line 45.84 * 63.09 53.09-17.25 (QP) 0.63 Line 49.42 38.51 56.00 46.00-6.58 (QP) 1.73 Line 40.75 * 56.00 46.00-15.25 (QP) 6.28 Line 40.56 * 60.00 50.00-19.44 (QP) 9.65 Line 40.40 * 60.00 50.00-19.60 (QP) Remark (1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./mhz Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./mhz (2) All readings are QP Mode value unless otherwise stated AVG in column of Note. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured, but AVG Mode didn t perform In this case, a * marked in AVG Mode column of Interference Voltage Measured (3) Measuring frequency range from 150KHz to 30MHz Report No.: NEI-FCCE-1- Page 16 of 26

E.U.T : Speaker System Z320 Model Name : S-00079 Temperature : 29 C Relative Humidity : 51 % Pressure : 1010 hpa Test Voltage : AC 120V/60Hz Test Mode : AUDIO IN(Adapter Model: EFS01801600112UL) Freq. Terminal Measured(dBuV) Limits(dBuV) Margin (MHz) L/N QP-Mode AV-Mode QP-Mode AV-Mode (db) Note 0.17 Neutral 48.94 * 65.06 55.06-16.12 (QP) 0.62 Neutral 49.96 37.83 56.00 46.00-6.04 (QP) 1.19 Neutral 42.13 * 56.00 46.00-13.87 (QP) 1.73 Neutral 41.53 * 56.00 46.00-14.47 (QP) 2.52 Neutral 41.38 * 56.00 46.00-14.62 (QP) 4.36 Neutral 40.29 * 56.00 46.00-15.71 (QP) Remark (1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./mhz Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./mhz (2) All readings are QP Mode value unless otherwise stated AVG in column of Note. If the QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured, but AVG Mode didn t perform In this case, a * marked in AVG Mode column of Interference Voltage Measured (3) Measuring frequency range from 150KHz to 30MHz Report No.: NEI-FCCE-1- Page 17 of 26

4.2 RADIATED EMISSION MEASUREMENT 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT FREQUENCY (MHz) Class A (at 10m) Class B (at 10m) dbuv/m dbuv/m 30 230 40 30 230 1000 47 37 Notes: (1) The limit for radiated test was performed according to as following: CISPR 22/ FCC PART 15B /ICES-003. (2) The tighter limit applies at the band edges. (3) Emission level (dbuv/m)=20log Emission level (uv/m). LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz) FREQUENCY (MHz) Class A (dbuv/m) (at 3m) Class B (dbuv/m) (at 3m) PEAK AVERAGE PEAK AVERAGE Above 1000 80 60 74 54 Notes: (1) The limit for radiated test was performed according to FCC PART 15B. (2) The tighter limit applies at the band edges. (3) Emission level (dbuv/m)=20log Emission level (uv/m). FREQUENCY RANGE OF RADIATED MEASUREMENT (For unintentional radiators) Highest frequency generated or Upper frequency of measurement used in the device Range (MHz) or on which the device operates or tunes (MHz) Below 1.705 30 1.705 108 1000 108 500 2000 500 1000 5000 5 th harmonic of the highest frequency or 40 GHz, Above 1000 whichever is lower Report No.: NEI-FCCE-1- Page 18 of 26

4.2.2 MEASUREMENT INSTRUMENTS LIST Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until 1 Log-Bicon Antenna Schwarzbeck VULB 9160 3173 Jul. 01, 2009 2 Test Cable N/A 10M_OS01 N/A Oct. 09, 2009 3 Test Cable N/A OS01-1/-2 N/A Oct. 09, 2009 4 Pre-Amplifier Anritsu MH648A M09961 Oct. 09, 2009 5 EMI Test Receiver R&S ESCI 100080 Feb. 22, 2010 6 Antenna Mast Chance Most CMTB-1.5 N/A N/A 7 Turn Table Chance Most CMTB-1.5 N/A N/A Remark: N/A denotes No Model Name / Serial No. and No Calibration specified. 4.2.3 TEST PROCEDURE a. The measuring distance of at 10 m shall be used for measurements at frequency up to 1GHz. For frequencies above 1GHz, any suitable measuring distance may be used. b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3m or 10 meter open area test site. The table was rotated 360 degrees to determine the position of the highest radiation. c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the antenna are set to make the measurement. d. The initial step in collecting radiated emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed. f. For the actual test configuration, please refer to the related Item EUT Test Photos. 4.2.4 DEVIATION FROM TEST STANDARD No deviation Report No.: NEI-FCCE-1- Page 19 of 26

4.2.5 TEST SETUP 3 or 10 m EUT 1-4 m 80 cm Ground Plane Test Receiver Amp. 4.2.6 BLOCK DIAGRAM OF TEST SETUP AC Mains Audio Cable EUT-1 Adapter EUT Audio Cable PC USB Cable USB Cable Mouse Keyboard AC Mains D-Sub Cable LCD Monitor Parallel Cable Printer RS232 Cable Modem 4.2.7 EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 4.1.7 Unless otherwise a special operating condition is specified in the follows during the testing. Report No.: NEI-FCCE-1- Page 20 of 26

4.2.8 TEST RESULTS E.U.T : Speaker System Z320 Model Name : S-00079 Temperature : 29 C Relative Humidity : 51 % Pressure : 1010 hpa Test Voltage : AC 120V/60Hz Test Mode : AUDIO IN(Adapter Model: S018BU1600112) Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin (MHz) H/V (dbuv) (db) (dbuv/m) (dbuv/m) (db) 93.05 V 34.69-10.16 24.53 30.00-5.47 112.45 V 27.74-6.76 20.98 30.00-9.02 197.81 V 30.23-7.49 22.74 30.00-7.26 299.66 V 29.45-3.75 25.70 37.00-11.30 640.13 V 21.49 4.02 25.51 37.00-11.49 749.74 V 23.85 6.10 29.95 37.00-7.05 Note Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./mhz (2) All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn t perform (3) Measuring frequency range from 30MHz to 1000MHz (4) If the peak scan value lower limit more than 20dB, then this signal data does not show in table Report No.: NEI-FCCE-1- Page 21 of 26

E.U.T : Speaker System Z320 Model Name : S-00079 Temperature : 29 C Relative Humidity : 51 % Pressure : 1010 hpa Test Voltage : AC 120V/60Hz Test Mode : AUDIO IN(Adapter Model: S018BU1600112) Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin (MHz) H/V (dbuv) (db) (dbuv/m) (dbuv/m) (db) 99.84 H 31.60-9.03 22.57 30.00-7.43 197.81 H 28.42-7.49 20.93 30.00-9.07 299.66 H 26.18-3.75 22.43 37.00-14.57 640.13 H 20.47 4.02 24.49 37.00-12.51 748.77 H 17.48 6.09 23.57 37.00-13.43 903.97 H 18.30 8.71 27.01 37.00-9.99 Note Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./mhz (2) All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn t perform (3) Measuring frequency range from 30MHz to 1000MHz (4) If the peak scan value lower limit more than 20dB, then this signal data does not show in table Report No.: NEI-FCCE-1- Page 22 of 26

E.U.T : Speaker System Z320 Model Name : S-00079 Temperature : 29 C Relative Humidity : 51 % Pressure : 1010 hpa Test Voltage : AC 120V/60Hz Test Mode : AUDIO IN(Adapter Model: EFS01801600112UL) Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin (MHz) H/V (dbuv) (db) (dbuv/m) (dbuv/m) (db) 83.35 V 33.69-9.93 23.76 30.00-6.24 97.90 V 30.27-9.35 20.92 30.00-9.08 145.43 V 26.73-4.89 21.84 30.00-8.16 180.35 V 26.60-5.11 21.49 30.00-8.51 298.69 V 29.55-3.79 25.76 37.00-11.24 749.74 V 23.27 6.10 29.37 37.00-7.63 Note Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./mhz (2) All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn t perform (3) Measuring frequency range from 30MHz to 1000MHz (4) If the peak scan value lower limit more than 20dB, then this signal data does not show in table Report No.: NEI-FCCE-1- Page 23 of 26

E.U.T : Speaker System Z320 Model Name : S-00079 Temperature : 29 C Relative Humidity : 51 % Pressure : 1010 hpa Test Voltage : AC 120V/60Hz Test Mode : AUDIO IN(Adapter Model: EFS01801600112UL) Freq. Ant. Reading(RA) Corr.Factor(CF) Measured(FS) Limits(QP) Margin (MHz) H/V (dbuv) (db) (dbuv/m) (dbuv/m) (db) 97.90 H 31.54-9.35 22.19 30.00-7.81 145.43 H 27.60-4.89 22.71 30.00-7.29 196.84 H 28.83-7.42 21.41 30.00-8.59 299.66 H 27.62-3.75 23.87 37.00-13.13 575.14 H 22.40 2.74 25.14 37.00-11.86 749.74 H 17.27 6.10 23.37 37.00-13.63 Note Remark: (1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW =120KHz, Swp. Time = 0.3 sec./mhz (2) All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn t perform (3) Measuring frequency range from 30MHz to 1000MHz (4) If the peak scan value lower limit more than 20dB, then this signal data does not show in table Report No.: NEI-FCCE-1- Page 24 of 26

5. EUT TEST PHOTO Conducted Measurement Photos Report No.: NEI-FCCE-1- Page 25 of 26

Radiated Measurement Photos Report No.: NEI-FCCE-1- Page 26 of 26

ATTACHMENT PHOTOGRAPHS OF EUT Report No.: NEI-FCCE-1- Page 1 of 18

Report No.: NEI-FCCE-1- Page 2 of 18

Report No.: NEI-FCCE-1- Page 3 of 18

Report No.: NEI-FCCE-1- Page 4 of 18

Report No.: NEI-FCCE-1- Page 5 of 18

Report No.: NEI-FCCE-1- Page 6 of 18

Report No.: NEI-FCCE-1- Page 7 of 18

Report No.: NEI-FCCE-1- Page 8 of 18

Report No.: NEI-FCCE-1- Page 9 of 18

Report No.: NEI-FCCE-1- Page 10 of 18

Model Name: S018BU1600112 Report No.: NEI-FCCE-1- Page 11 of 18

Report No.: NEI-FCCE-1- Page 12 of 18

Report No.: NEI-FCCE-1- Page 13 of 18

Report No.: NEI-FCCE-1- Page 14 of 18

Model Name: EFS01801600112UL Report No.: NEI-FCCE-1- Page 15 of 18

Report No.: NEI-FCCE-1- Page 16 of 18

Report No.: NEI-FCCE-1- Page 17 of 18

Report No.: NEI-FCCE-1- Page 18 of 18