Troubleshooting accelerometer installations

Similar documents
Installation of vibration sensors

Industrial vibration sensor selection: piezovelocity transducers

Industrial vibration sensor selection: Piezovelocity transducers

ACCELERATION TRANSDUCER INSTRUCTION MANUAL

Models Z7, Z11, Z602WA and Z820WA Impedance head operating guide

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Mounting Instructions

Unstable Reading of Accelerometers in Cryogenic Service. Cryodynamics Division

Sensor selection guide

Presented By: Michael Miller RE Mason

it150 Series Vibration Transmitters Installation and Operating Manual

Introduction*to*Machinery*Vibration*Sheet*Answer* Chapter*1:*Vibrations*Sources*and*Uses*

What are we looking at?

Low frequency machinery monitoring: measurement considerations

PA FAN PLATE ASSEMBLY 188D6127G1 SYMBOL PART NO. DESCRIPTION. 4 SBS /10 Spring nut. 5 19A702339P510 Screw, thread forming, flat head.

INSTALLATION AND OPERATION

731A seismic accelerometer and P31 power unit/amplifier Operating guide

EEE 432 Measurement and Instrumentation

Wilcoxon Research PA8HF power amplifier Operating guide

PA8HF power amplifier Operating guide

Developer Techniques Sessions

Device Interconnection

Q: What does it mean if the RF generator will not put out full power and the reflected power is nearly equal to forward power?

Acceleration Enveloping Higher Sensitivity, Earlier Detection

Troubleshooting RTDs and Thermocouples

AGN 008 Vibration DESCRIPTION. Cummins Generator Technologies manufacture ac generators (alternators) to ensure compliance with BS 5000, Part 3.

results at the output, disrupting safe, precise measurements.

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

Experiment 1: Instrument Familiarization (8/28/06)

AC AC AC

Oscilloscope Applications MREC Rural Energy Conference 2012 Prepared by Paul Ortmann, P.E. /

MASTERFLEX L/S ECONOMY 200 RPM DRIVE 115 VOLT MASTERFLEX L/S ECONOMY 200 RPM DRIVE 230 VOLT

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

Know and understand you and your co-workers competence level before opening a live panel to diagnose

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

CONTINUOUS CONDITION MONITORING WITH VIBRATION TRANSMITTERS AND PLANT PLCS

CMA-100. Counter Measures Amplifier. Owner s Guide

Inductive Loop Detector

Four Channel Inductive Loop Detector

DLVP A OPERATOR S MANUAL

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

AUDIO SYSTEMS 8F - 1 AUDIO SYSTEMS CONTENTS

Piezoelectric accelerometer design. Piezoelectric transducers Quartz and piezoceramics Mechanical design Charge amplification Design trade-offs

Current Draw (Circuit breakers and fuses blow. Burning smell or smoke)

Single-Axis, High-g, imems Accelerometers ADXL193

79/26 Series III Multimeter

Experiment (1) Principles of Switching

GE Energy Operating Guide Series Industrial Transmitter, with Dynamic Signal Sensor

Experiment 1: Instrument Familiarization

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

CAN BUS TROUBLESHOOTING

MODEL 140 VIBRATION TRANSMITTER

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

CONTENTS. User Manual

Introduction to LIVM Accelerometers

Three Hidden Demons in your Network

Chapter 2 Analog-to-Digital Conversion...

Dual-Axis, High-g, imems Accelerometers ADXL278

Benefits of Implementing a Basic Vibration Analysis Program for Power Transmission Drives

Silicon Full-Wave Bridge Rectifier Testing. Drawn by Jon Pardue 2007, 2009, and 2011 Updated September 2012 by Jon Pardue.


3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

EXPERIMENT 5 : THE DIODE

Models N7FS, N8FS, and N8HFS Matching networks operating guide

General Application Notes Remote Sense Remote On / Off Output Trim Series Operation Parallel Operation...

OPVibr Ultrasonic vibration measurement system Ultrasonic vibrometer INSTRUCTION MANUAL

Maintenance Manual LBI-38531G MHz, 110 WATT POWER AMPLIFIER 19D902797G1 DESCRIPTION TABLE OF CONTENTS

Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide

Electromagnetic shakers operating guide Models F3, F4, F5B, F10

Common Sensors. Understand the following sensors: Pull Up sensor Pull Down sensor Potentiometer Thermistor

Technical Information

Entry Level Assessment Blueprint Electronics Technology

To Float or Not to Float? Analysis of a floating vs. grounded output Associated Power Technologies

Using Circuits, Signals and Instruments

OPERATING AND MAINTENANCE MANUAL

Micrel, Inc Fortune Drive San Jose, CA USA tel + 1 (408) fax + 1 (408)

WHITE PAPER. Continuous Condition Monitoring with Vibration Transmitters and Plant PLCs

AUDIO SYSTEMS 8F - 1 AUDIO SYSTEMS CONTENTS

Application Note (Revision NEW) Original Instructions. EMI Control in Electronic Governing Systems

Bearing Fault Diagnosis

White Paper: Electrical Ground Rules

SSPMA Sump and Sewage Pump Manufacturers Association

ST6911 IPT ACCELERATION VIBRATION TRANSDUCER ST6917 IPT VELOCITY VIBRATION TRANSDUCER Installation Manual

Operation and Maintenance Manual

EXPERIMENT 5 : THE DIODE

Motors and drives. Module B- Introduction to input measurements

Horizon User s Guide

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

ABCs of DMMs. Multimeter features and functions explained. Application Note. Introduction. Choosing your DMM. Some basics

Making sense of electrical signals

The silicon controlled rectifier (SCR)

MAKERS OF THE ORIGINAL HOT SPOT PERSONAL MONITOR

SEMASPEC Provisional Test Method for Evaluating the Electromagnetic Susceptibility of Thermal Mass Flow Controllers

CRICKET POLARITY TEST SET OWNERS MANUAL GALAXY AUDIO. 601 E. Pawnee Wichita, KS 67211

OIS25. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

W100/W600/W900 Controller ph Electrode Troubleshooting Guide

CMA-100. User Manual. Counter Measures Amplifier

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

Basic Electronics Learning by doing Prof. T.S. Natarajan Department of Physics Indian Institute of Technology, Madras

Amplified High Speed Photodetectors

Transcription:

Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most commonly occurring problems. The troubleshooting techniques presented are very simple and can be performed using most monitoring systems and data collectors or simple test equipment. Many installation and problems can be detected by measuring the bias voltage of the. The bias voltage will indicate faulty cable routes and failed s. Many online systems are capable of trending the bias voltage. Other problems can be detected by analyzing the time waveform and FFT spectrum. Accelerometer operation and response Most accelerometer faults can be diagnosed by measuring the bias voltage of the amplifier. If the bias voltage is within correct limits the is most likely operating properly. Most cabling faults can also be isolated by measuring the bias. After the bias is checked, the time waveform and FFT spectrum will verify fault diagnosis or proper operation. AC coupling and the DC bias voltage The output is an AC signal proportional to the vibration applied. This AC signal is superimposed on a DC bias voltage, also referred to as Bias Output Voltage (BOV) or sometimes rest voltage. The DC component of the signal is generated by the 2 ma constant current diode in the power supply. This DC voltage needs to be blocked by a coupling capacitor in the measurement equipment, leaving the AC output signal. Most vibration data collectors, monitors, and power units contain an internal blocking capacitor for AC coupling. If not included, a blocking capacitor must be field installed. What is bias voltage? The majority of accelerometers, PiezoVelocity Transducers (PVT ), and pressure s have a biased output. Biased outputs are characteristic of two-wire s used to measure dynamic AC signals. Vibration and pressure are examples of dynamic signals that vary with time. The external power supply provides a DC voltage to the accelerometer. This power supply voltage is normally 18 to 30 volts DC. The accelerometer amplifier circuit design establishes this voltage (or biases the voltage) to a preset level. This BOV is normally 12 VDC, although it may vary depending on the manufacturer and design. The accelerometer s specification sheet provides further information on the BOV. The BOV is determined by the amplifier design and is not adjustable. The BOV remains the same regardless of the input power to the accelerometer, as long as the input power is within the specified range. For example, if the BOV is 12 VDC and the input power is specified as 18 to 30 V, then the BOV will be 12 VDC if the input power is 18 VDC. If the input power is increased to 30 VDC, the BOV will remain at 12 VDC. The BOV is set by the interaction of the amplifier circuit in the accelerometer and the constant current from the stand-alone power supply or the analyzer or data collector.

Figure 1 is a diagram representing the performance of the circuit. The line represented by Instrument Power and BOV is one conductor that has two functions. So even though the power supply is providing a higher input voltage, the BOV is the measured output voltage level on the cable connecting the accelerometer to the data collector or analyzer. The BOV carries the dynamic vibration signal to the analyzer. The AC signal swings high and low from the BOV level and is limited by the power supply level and ground. For example, if the power supply level is 24 volts, the swing of the AC signal would be limited to no more than 24 volts and no less than ground (0 volts). These are theoretical limits. In reality, the limits to this swing occur at about 1.5 volts above ground and about 1.5 volts below the power supply level, as shown in figure 2. Figure 1: Sensor amplifier circuit Figure 1: Sensor amplifier circuits Most portable data collectors and online systems supply 24 volts to the. The should have a nominal BOV of approximately one half of the power supply voltage, to maximize the amount Figure 2: AC signal limits of swing in the positive and negative directions. Most two-wire s produce an 8 to 14 volt bias. When the signal amplitude runs into the supply voltage or ground, clipping occurs. Clipping the vibration signal distorts the waveform. In other words, a clipped signal is no longer a true analog representation of the vibration the is attempting to measure. Measuring the BOV The constant current diode (CCD) limits the current supplied to the. It provides a constant current to the regardless of the supply voltage because the use of unlimited power supply current will damage most internally amplified s. For this reason, most commercially available data collectors and vibration monitors have power supply circuits that include a CCD to regulate the power supplied to the. Figure 3: Schematic of a power supply Most battery power supplies contain a 2 ma CCD to ensure long battery life. Line powered supplies (where power consumption is not a concern) should contain 6 to 10 ma CCDs. This offers the ability to drive long cables. For operation above 100 C, it is best to limit the current to less than 6 ma to reduce self heating. Most data collectors supply 2 ma of current to the ; most online systems supply 4 to 6 ma. If a power supply that is not current limited is used, a CCD should be placed in series with the voltage output of the supply. Ensure that proper diode polarity is observed. If a current limited power supply is probed with a voltmeter the supply voltage will be measured before the CCD. The bias voltage will be measured on the side of the CCD connected to the. Figure 3 shows a schematic of a power supply containing a fixed CCD between 2 and 10 ma.

The BOV should be measured periodically to check operation. The best measurement device is a voltmeter, however, most portable data collectors can measure the BOV if the is powered from a different source (other than the data collector). When using the data collector as a voltmeter the DC voltage input setting is used. Oscilloscopes can also measure the BOV by selecting the DC coupled input. The BOV can be trended with many online systems. Trending the BOV provides a record of operation. If the is disconnected or slowly develops a fault, the BOV data can show when the event occurred. The BOV will also indicate the condition of the cabling and connectors. If the BOV level measurement is equal to the supply voltage, the may be disconnected or reverse powered. A measurement of 0 volts indicates a short in the system. An unstable bias voltage can indicate poor connections, but can also be caused by a clipped signal or severe electromagnetic interference. Time waveform and FFT spectrum fault analysis The time waveform of a can be measured with an oscilloscope, most data collectors, and online vibration monitoring systems. Reviewing the time waveform can immediately indicate a clipped signal, which usually looks truncated or flattened on one side and normal on the other. Severely clipped signals will cause the waveform to look jumpy. Poor connections can also cause a similar jumpy reading. The FFT spectrum can give another quick indication of signal quality. The one-times (1X) operating speed vibration is usually present and a good indication of proper operation. The presence of a large ski slope can indicate distortion from overload. However, a noisy accelerometer that has been integrated to velocity or displacement may also produce ski-slopes for various reasons. Cable routing faults can also be detected by analyzing the FFT. Multiples of the line power frequency usually indicates improper shielding or grounding. If the time and frequency measurements read zero, the is disconnected or is not operating. Fault indications Open bias fault: Supply voltage (18-30 V) When the measured BOV equals the supply voltage, the amplifier is disconnected or reverse powered. In most cases the problem is the connector or cabling. First check the cable termination at the junction box, data collector or monitoring system. If the cable is connected to a terminal block, make sure the wires are secure and in the proper terminal. Next check the cable connection to the. Many times, the was disconnected for maintenance and was never reconnected. If a faulty connector is detected, it can be disassembled or replaced, but avoid disassembling or removing the connector until all other fault sources have been checked. If each end appears good, check all other terminations, splices and connectors. Also ensure that the cable is not crushed or cut. If the cable route and connections appear good, further test the cable continuity. Cable continuity can be tested by shorting the signal leads at one end of the cable to the shield wire and measuring the opposite end with an ohmmeter. Depending on the cable length, several ohms to no more than several hundred ohms should be measured from each wire to the shield. If the cable and all connections are in proper working order, the fault is in the. However, open faults inside the are very rare. Short bias fault: 0 volts When the bias measures 0 volts, power failure or a system short is usually the problem. First ensure that power is turned on and connected. If the power supply is on, check for a short in the cabling. Like the open fault, it

is very rare to have a short inside the. The most common fault location is in junction box terminations. Check to make sure that a frayed shield is not shorting across the signal leads. Many times a crushed cable can produce a short. Use an ohmmeter to check electrical isolation between the leads. Disconnect the cable from all other devices and measure between all signal leads and shields. When measuring the resistance between the cable conductors, the ohmmeter should measure infinite or at least above 50 megaohms. Damaged : Low bias, high bias Out of specification bias readings other than those listed above usually indicate damage. Common sources of damage are exposure to excessive temperature, shock impacts, mispowering, and electrostatic discharge. Excessive temperature is the most common cause of failure. Sensors caught in a fire are usually destroyed and can show various bias readings depending on the failure mode within the. Long term temperature failures are marked by a slowly rising or declining bias voltage. In many cases bias returns to normal as the temperature decreases. However, the damage to the amplifier is permanent and the amplifier may continue to deteriorate. Figure 4 shows the bias trend of a failing from long term temperature degradation in a paper machine dryer section. Excessive shock, mispowering and electrostatic discharge can permanently damage the amplifier of unprotected s. Industrial s typically contain protection devices to prevent these types of failures. Erratic bias and time waveform Figure 4: BOV trend of a exposed to long-term excessive temperatures The bias voltage should remain stable and unchanging for properly operating s. Shifting bias indicates a very low frequency signal that is not filtered out by a DC meter. In rare cases this indicates an actual low frequency signal, however in most cases this indicates a fault. Primary causes of erratic bias are thermal transients, poor connections, ground loops, and signal overload. Each of these faults will also be visible in the time waveform as erratic jumping or spiking of the signal. Thermal transients cause uneven thermal expansion of the housing materials. This can be detected by the as a low frequency signal. The problem is most evident when using low frequency s. Poor or contaminated connections can also cause low frequency bias and contact noise. Look for corroded, dirty, or loose connections. Repair or replace the connection as necessary. Non-conducting silicone grease should always be applied to connectors to reduce contamination. Ground loops are developed when the cable shield is grounded at two points of differing potential. Always ground the shield at one end only! An easy test for ground loops is to disconnect the shield at one end of the cable. If the problem disappears it was probably a ground loop fault. Figures 5a and 5b show a connection susceptible to ground loops and a correct installation where the shield is tied at one end only. Figure 5a: A poorly grounded installation Figure 5b: A properly grounded installation

Sometimes spurious spikes from fast thermal shifts, lightning strikes, and shocks can overload the and cause a momentary shift in the bias voltage. The shift in bias can trigger alarms and protection system shutdown devices. To prevent triggering alarms and shutdown, a longer delay can usually be programmed or hardwired into the monitoring system. The delay prevents the system from taking action until the has settled. High frequency, high amplitude vibration signals can also overload the and in severe cases cause bias shift and erratic time waveform. However, overload problems are usually detected by observing truncated waveforms and large ski-slope spectrums. Truncated time waveform: overload Truncated (flattened) time waveforms indicate that the signal is clipping. Clipping causes the amplifier to saturate and become overloaded. Some common mechanical causes of an overload in the are severe pump cavitation, steam release, impacts from loose or reciprocating parts and even gearmesh. One way to reduce clipping is to use a higher power supply voltage and ensure that the bias voltage is centered between supply voltage and ground voltage. However the bias voltage and power supply are rarely adjustable. For example, if you are using an 18 volt power supply and a 12 volt bias, clipping will occur sooner than if you used a 24 volt power supply. Long cables in excess of 200 feet can also reduce the amplitude swing at high frequencies and may be a problem in some applications. The easiest solution is to use a lower sensitivity. A with 10 mv/g sensitivity will have a hundred times larger amplitude range than a similar 1 V/g. Ski-slope spectrum Sensor overload may also produce a ski-slope spectrum. If the amplifier saturates, intermodulation distortion occurs. This causes low frequency noise, also referred to as washover distortion. Figures 6a shows a normal spectrum. Figure 6b shows what can happen when the signal becomes overloaded due to excessive vibration. Figure 6a: Normal operation Figure 6b: Overload operation Sometimes the ski-slope signals can be caused by the circuitry used to integrate acceleration signals to velocity or displacement. Figure 7 shows integration noise due to analog integration of an acceleration signal. Figure 7: Ski-slope noise caused by analog integration

Mounting resonance spectrum Mounting resonance can give false indication of high frequency machinery faults such as gear mesh and bearing problems. The problem is more likely to occur when using probe tips and magnets, and care must be exercised to prevent the measured mounting resonance peaks from being falsely identified as machine produced peaks. Mounting the on thin plates such as machine guards, can also lower the mounting resonance. Figure 8 shows the resonance of several common mounting techniques. Mounting resonance plots are shown for: (a) probe tip; (b) magnet; (c) Wilcoxon s QuickLINK ; and (d) stud mounted configurations. Figure 8a: Probe tip mounting resonance Figure 8b: Magnet mounting resonance Figure 8c: QuickLINK TM mounting resonance Figure 8d: Stud mounting resonance Re-measuring with the mounted at a different location will usually discriminate machine vibration from mounting resonance. However if a machine signal coincides with the resonance of the mounting configuration, a greatly increased signal can happen. This can lead to overload which will be manifested with a spectrum dominated by a ski slope. Line frequency harmonics in spectrum Harmonics of AC line power frequency usually indicate interference from motors, power lines and other emissive equipment. First, ensure that the shield is grounded (at one end only). If the shielding is good, check the cable routing. A good measurement practice is to run signal cables in cable trays separate from power line cable trays by at least 12 inches. If a signal cable tray must come near a power cable tray, they should cross at right angles to reduce the possibility of magnetically coupled signals. Using shielded, twisted pair cable will also help minimize any magnetically coupled noise into the signal cable. For example, if a power cable is 440 volts and the vibration signals from the are at the millivolt level, any cross talk will severely corrupt the data.

Troubleshooting chart Below is a troubleshooting chart for s with a 12 volt bias. For s with other bias voltages, the same concepts apply only the stable bias range will be different. BOV Spectrum Time waveform Fault condition Action 0 V No signal No signal No power or cable/ connector short Test/turn on power Test cable isolation Repair/replace cable 2.5 5.0 V No signal No signal Damaged amplifier Replace High low frequency ski slope High amplitude high frequency noise High frequency overload (steam release, air leak, cavitation, etc.) Repair steam leak/dump Use less sensitive Place rubber pad under Very high low frequency ski slope No high frequency signal Good signal, strong 50/60 Hz High low frequency noise High low frequency noise Choppy Damaged amplifier Replace 50/60 Hz Inadequate shielding Connect ground/cable High frequency spikes Jumpy/choppy ESD Arcing impacts Intermittent connection Reroute cable Use less sensitive Place rubber pad under Repair connection 18.0 30.0 V No signal No signal Reversed powering Reverse leads 18.0 30.0 V No signal 50/60 Hz No signal Open cable connections Repair connection