Comparison and Detection of Abnormal Conditions in Induction Motors

Similar documents
Effect of Harmonics on the Performance Characteristics of Three Phase Squirrel Cage Induction Motor

Three-Phase Induction Motors Torque under Voltage Unbalance

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Reduction of flicker effect in wind power plants with doubly fed machines

INVESTIGATION OF THE IMPACT OF SPEED-RIPPLE AND INERTIA ON THE STEADY-STATE CURRENT SPECTRUM OF A DFIG WITH UNBALANCED ROTOR

Harmonics Elimination Using Shunt Active Filter

Journal of World s Electrical Engineering and Technology J. World. Elect. Eng. Tech. 3(1): 18-25, 2014

Voltage Unbalance Effects on Induction Motor Performance

1 INTRODUCTION 2 MODELLING AND EXPERIMENTAL TOOLS

Stator Fault Detector for AC Motors Based on the TMS320F243 DSP Controller

ROTOR FAULTS DETECTION IN SQUIRREL-CAGE INDUCTION MOTORS BY CURRENT SIGNATURE ANALYSIS

Behavior of Induction Motor at Voltage Unbalanced

Analysis Of Induction Motor With Broken Rotor Bars Using Discrete Wavelet Transform Princy P 1 and Gayathri Vijayachandran 2

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

Employing Finite Element Method to Analyze Performance of Three-Phase Squirrel Cage Induction Motor under Voltage Harmonics

Bahram Amin. Induction Motors. Analysis and Torque Control. With 41 Figures and 50 diagrams (simulation plots) Springer

Unbalance Detection in Flexible Rotor Using Bridge Configured Winding Based Induction Motor

An Introduction to Power Quality

Investigating the effects of Unbalanced Voltages and Voltage Harmonics on a Three-Phase Induction Motors Performance

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

Comparative Analysis of Multiple-pulse VSC-Based STATCOM s for Voltage-Dip Mitigation

Power Quality in Wind Power Systems

Generator Advanced Concepts

Voltage and Current Waveforms Enhancement using Harmonic Filters

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Analysis of Indirect Temperature-Rise Tests of Induction Machines Using Time Stepping Finite Element Method

Volume I Issue VI 2012 September-2012 ISSN

Estimation of Vibrations in Switched Reluctance Motor Drives

CHAPTER 3 VOLTAGE SOURCE INVERTER (VSI)

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

II. RESEARCH METHODOLOGY

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Latest Control Technology in Inverters and Servo Systems

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

Analysis of Harmonic Distortion in Non-linear Loads

A SPECIAL TRANSFORMER CONNECTION FOR THREE- PHASE TO FIVE-PHASE TRANSFORMATION

Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

BLDC TORQUE RIPPLE MINIMIZATION USING MODIFIED STAIRCASE PWM

Ultra-Modified Control Algorithms for Matrix Converter in Wind Energy System

A Robust Fuzzy Speed Control Applied to a Three-Phase Inverter Feeding a Three-Phase Induction Motor.

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

V. Ramakrishnan 1, and S.K. Srivatsa 2 1

Volume 1, Number 1, 2015 Pages Jordan Journal of Electrical Engineering ISSN (Print): , ISSN (Online):

Frequency Converter Influence on Induction Motor Rotor Faults Detection Using Motor Current Signature Analysis Experimental Research

Keywords: unbalanced voltage, unbalanced current, Load balancing transformer

Effects of Harmonic Distortion I

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Hybrid PWM switching scheme for a three level neutral point clamped inverter

SYNCHRONOUS MACHINES

A Single Phase Single Stage AC/DC Converter with High Input Power Factor and Tight Output Voltage Regulation

Pak. J. Biotechnol. Vol. 13 (special issue on Innovations in information Embedded and communication Systems) Pp (2016)

Comparison of Different Modulation Strategies Applied to PMSM Drives Under Inverter Fault Conditions

CONVERTERS IN POWER VOLTAGE-SOURCED SYSTEMS. Modeling, Control, and Applications IEEE UNIVERSITATSBIBLIOTHEK HANNOVER. Amirnaser Yazdani.

SPECIFIC HARMONIC ELIMINATION SCHEME FOR NINELEVEL CASCADED H- BRIDGE INVERTER FED THREE PHASE INDUCTION MOTOR DRIVE

Journal of Engineering Technology

Flicker Attenuation Part I: Response of Three- Phase Induction Motors to Regular Voltage Fluctuations

Speed Control of Induction Motor using Space Vector Modulation

p. 1 p. 6 p. 22 p. 46 p. 58

A Guide to Power Quality Testing

A Novel Three-Phase to Nine-Phase Transformation using a Special Transformer Connection

Designing Of Distributed Power-Flow Controller

Voltage Regulated Five Level Inverter Fed Wind Energy Conversion System using PMSG

Eyenubo, O. J. & Otuagoma, S. O.

Inter Harmonics of Cycloconveter Excited Induction Motor and Design its Filter Circuit

Comparative Analysis of Space Vector Pulse-Width Modulation and Third Harmonic Injected Modulation on Industrial Drives.

Understanding Harmonics

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

IN MANY industrial applications, ac machines are preferable

Performance Analysis of DFIG based Wind Energy Conversion System Using Direct Power Controller

Three Phase Induction Motor Performance under Unbalanced Voltage Conditions

NEW CRITERION FOR STATOR INTER TURN FAULT DETECTION OF SYNCHRONOUS GENERATOR

Brushless DC Motor Drive using Modified Converter with Minimum Current Algorithm

MATLAB/SIMULINK MODEL OF FIELD ORIENTED CONTROL OF PMSM DRIVE USING SPACE VECTORS

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

UNBALANCED CURRENT BASED TARRIF

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

CHAPTER 5 PERFORMANCE EVALUATION OF SYMMETRIC H- BRIDGE MLI FED THREE PHASE INDUCTION MOTOR

Assessment of Different Compensation Strategies in Hybrid Active Power Filters

Voltage Sag Effects on the Process Continuity of a Refinery with Induction Motors Loads

POWER QUALITY AND SAFETY

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Efficiency Optimized Brushless DC Motor Drive. based on Input Current Harmonic Elimination

Improved Grid Synchronization Algorithm for DG System using DSRF PLL under Grid disturbances

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

Assessment of Energy Efficient and Standard Induction Motor in MATLAB Environment

Power Quality Analysis in Power System with Non Linear Load

ANALYSING THE EFFECT OF USSC CONNECTION TO DISTRIBUTION SYSTEM ON VOLTAGE FLICKER

A Comparative Study of FFT, STFT and Wavelet Techniques for Induction Machine Fault Diagnostic Analysis

1. Introduction to Power Quality

Overview of IAL Software Programs for the Calculation of Electrical Drive Systems

Multi-Objective Optimal Design of a NEMA Design D Three-phase Induction Machine Utilizing Gaussian-MOPSO Algorithm

Power quality measurements in a singlehouse

MODELING AND SIMULATION OF UNIFIED POWER QUALITY CONDITIONER FOR POWER QUALITY IMPROVEMENT

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

INDUCTION MOTOR FAULT DIAGNOSTICS USING FUZZY SYSTEM

Transcription:

Comparison and Detection of Abnormal Conditions in Induction Motors Mehrdad Heidari 1, Ghodratollah Seifossadat 2, Davar Mirabbasi 1 mehrdad266@yahoo.com, seifossadat@yahoo.com, dmirabbasi@yahoo.com 1 PhD student of Shahid Chamran University 2 Assistant professor of Shahid Chamran University, Ahvaz, Iran Abstract Deficiencies like unbalanced voltages or harmonics in the voltage source could result in problems like excessive losses, over-voltages, mechanical oscillations, and interference with control electronics. Detecting these abnormal conditions in the machine is of great importance in the interaction of the electrical machine and the power grid. In this paper the effect of the unbalanced voltages, harmonics and flicker on the motor performance, have been investigated. Then, monitoring these unhealthy condition using electrical machine parameters is carried out. In this case, motor itself can act as the sensor that detects abnormal conditions. Also this paper investigates the negative effects of unbalanced sinusoidal voltage which always present in the power supply over balanced (inverter supply) non-sinusoidal voltage on the performance of induction motor in terms of line currents, power factor and efficiency. According to the test results and analysis, the negative effects of unbalanced sinusoidal voltage are more than the balanced no sinusoidal voltage on the motor's performance. 1. Introduction According to the U.S. Department of Energy (DoE), 70% of the electricity is used by industrial motors, and in a typical industry the 80% of the load consists of three-phase AC induction motors [1]. Induction motors are being used more than ever before due to their versatility, dependability and economy, good self-starting capability, offers users simple, rugged construction, easy maintenance, low cost and reliability. As the industries are developed more and more, the high quality of the electric power has been concerned in manufacturing plants. The power quality is deteriorated in terms of voltage sag, swell, surge, blackout, harmonics, or unbalanced voltage. The unbalanced voltage gives a bad influence for the power quality. If the unbalanced power is applied to the electric apparatuses, it gives a difficult problem to them, especially the electric motors. The unbalance voltage is caused by unsymmetrical transformer windings or transmission impedances, unbalanced loads, or large single phase loads. Even unbalanced voltage applied to the motor is small, large unbalanced motor current can be flowed because of relatively low negative sequence impedance. The large unbalanced current makes difficult problems in induction motor applications, such as a heat problem, increases of losses, vibrations, acoustic noises, shortening of the life, reduction in efficiency, a decrease of the rotating torque and creating a torque pulsation. [8]. Role of induction motors in industry increased after the development of adjustable speed drives. However, it is wellknown that the operation of the motor cannot be done under conditions of perfectly balanced supply voltage. This asymmetry induces negative-sequence current which in its turn produces a backward rotating field in addition to the forward rotating field produced by the positive sequence one. The interaction of these fields produces pulsating electromagnetic torque and velocity disturbances resulting in increasing losses, stresses and noise in the machine [2-5]. The efficacy of normal operation of a motor from an unbalanced supply depends directly on the degree of unbalance at the terminals of the machine. It is therefore essential that a suitable standard be used to quantify the degree of voltage unbalance. The NEMA and IEC standards introduce independent definitions for voltage unbalance and one of these is normally used for the analysis of electrical machines [6-9].. In most cases, condition monitoring schemes have focused on one of three induction motor components: the stator, rotor or bearings. While the use of vibration monitoring is currently extensive, moderately little attention has been paid to voltage unbalance in the motor supply. Because of the wide use of the induction motors both in industrial and residential areas, the damaging effects on induction motors will cause an important economic impact. Harmonics produced by inverters can be in some cases a main source of vibration and oscillations in AC motors. The fundamental harmonic component is positivesequence, second harmonic is negative-sequence, and third harmonic is zero-sequence, repeating this pattern higher order harmonics. Negative sequence harmonics produce a pulsating torque that causes excess of power losses in the winding as it works against the fundamental component. This is the case of the harmonic component created by the voltage unbalance. Those with positive sequence have a forward rotation and also increase the losses due to skin effect and eddy currents. Finally, triplen harmonics are zero-sequence harmonics that are multiples of third harmonic and they have no effect on torque pulsation. The harmonics caused by inverters, in practice, are odd and not a multiple of three. In [10] the impact of harmonics on induction motors is analyzed, and for example, for the lowest harmonic frequencies, which are fifth and seventh in a three phase square wave inverter, they produce a torque that pulsates at a sixth harmonic frequency. In addition, as higher order harmonics produce torque components at higher frequencies, they have a lower impact on the speed ripple because of the integrative effect of the system inertia. The harmonic content of the inverter output depends on the type of control [11]. In this paper two methodologies are applied to a three phase induction motor, using the well-know Matlab/Simulink software. The simulated results presented clearly show that the I-382

proposed techniques can accurately early detection, abnormal condition of induction motor. 2. Comparison Effect of Balanced, Unbalanced and Balanced but with Harmonics (non Sinusoidal) Voltages on Induction Motors The motor was tested from no load condition to full load by varying applied load to the motor for three the non-sinusoidal balanced, the unbalanced and balanced sinusoidal voltage conditions. Fig.1 shows the simulation results for a 20HP (15Kw), 400V rms line to line, three-phase squirrel-cage induction motor supplied by three conditions. Efficiency of the tested motor under unbalanced sinusoidal voltage is smaller than the motor operated with balanced non-sinusoidal (inverter) voltage shown in Fig. 1. Maximum line current drawn by the motor under both operating conditions is shown in Fig. 1. This figure shows that the maximum current drawn by the motor under first condition is higher than the current under second condition. Lower power factor is obtained by use of balanced non-sinusoidal voltage (Fig.1). Fig. 2: balanced case: torque & speed, FFT of ripple 3.2. Unbalanced Cases Fig. 1: Three evaluated factors of induction motor: Ismax, efficiency, power factor 3. Normal and Unbalanced Conditions Analysis 3.1. Normal Case In this section normal operating condition has been investigated. It is necessary to accomplish this to develop a reference for comparison purposes. This model has been simulated. In normal condition, motor was supplied by its rated voltage which is 326.6 volts peak for each phase. The voltages applied are as follows: Va = 326.6 0, Vb = 326.6 240, Vc = 326.6 120, f = 50Hz (1) Fig. 2 depicts the simulation results in this case. As shown in this figure the torque ripple is almost negligible. In this part the unbalance in the phase and the magnitude of the voltage has been considered. In order to model the electrical motor symmetrical components can be used. A wide variety of research has been done on modeling of unbalanced condition. In the unbalanced voltage operating condition the torque can be written as follows [12, 13]: T = P = ( P0 + P2 ) / ω = T0 + T ω 2 (2) In which, T 0 is the DC torque. T 2, is the torque component whose frequency is twice the supply frequency. In a simpler way assuming induction motor as a RL load the torque can be written as: T = η E I /ω (3) In which E and I are input voltage and current of each phase respectively. Assuming sinusoidal waveforms for voltage and current this equation can be rewritten as: T = K cos( 2π 50t + α) cos(2π 50t + β ) (4) So, / T = K [ cos( α β ) + cos(2π100t + α + β ] (5) Based on equation (5) the resulting torque would include a DC term and a term whose frequency is twice the fundamental frequency of the applied voltage. In order to detect the unbalanced supply voltage this extra torque component can be used. 3.2.1. Unbalance in the voltage magnitude In this case an unbalance of 20% and 15% of the rated voltage is assumed for phase B and C voltages respectively. So, the value of the voltages for phases A, B and C would be as follows: Va = 326.6 0, Vb = 326.6 * 0.8 240, Vc = 326.6 * 0.85 120 The torque components from simulated model have been shown in figure 3. In order to have a better view of the torque components frequency analysis has been made using DFT. Torque components have been shown in figure 3. According to I-383

this figure there is a DC component and a 100 Hz component(second order) as expected. The magnitude of this component is big enough to be measured. Comparing to the case of the normal operation the average torque is decreased while the ripple has increased significantly. Fig. 4: vol. phase unbalance case: torque & speed, FFT analysis of ripple Fig. 3: vol. mag. unbalance case : torque & speed, FFT analysis of ripple 3.2.2. Unbalance in the voltage phase In this part an unbalance of 10% is assumed for the phase of applied voltages of phase B and C. The applied 3 phase voltages are as follows: Va = 326.6 0, Vb = 326.6 216, Vc = 326.6 132 Fig. 5 depicts the torque components in this case. Based on the figure there is a significant increase in the torque ripple while the average torque has decreased a little bit comparing to normal case. 3.2.3. Unbalance in the Voltage Magnitude and Phase In this case an unbalance of 10% is applied for voltage Phase and magnitude. The applied voltages are as follows: Va = 326.6 0, Vb = 326.6*.9 216, Vc = 326.6*.9 132 The torque components have been shown in Fig. 5 depicts the torque components in this case. As expected in this case the ripple is increased more and the average torque is decreased. From the performance point of view pulsating torque is unaccepted so it is important to detect and avoid any kind of unbalance in the voltage Fig.5: vol. phase & mag. unbalance case: torque & speed, FFT analysis of ripple. I-384

4. Harmonic Analysis Because of the destructive effects of the harmonics like torque pulsation, acoustic noise and increased losses a wide variety of the research have been done to minimize the harmonics in the voltage supply [14-16]. In this part three major harmonics namely, 3rd, 5th, and 7th harmonics are introduced to the model. Moreover, a combination of these harmonics is considered as well. The machine has been supplied with the rated voltage and the harmonics are injected in the voltage source. The applied voltage can be written as: V ( t) = V sin(2π ft) + V k sin(2πkft + θ (6) 1 k ) k = 3,5,7 It is shown in [9] that the current in the stator windings are as follows: Vk ( t) Ik ( t) = k = 1,3,5,7 (7) 2 2 Req + X eq) In which R eq and X eq are stator equivalent resistance and reactance respectively. Based on equation (7) it is expected that the harmonics with the same frequency but different amplitude would be present in the stator currents. Fig. 7: FFT analysis of Ib: with 5th harmonic The frequency analysis of the current waveforms has been depicted in Fig. 7. 4.3. 7th Harmonic In this case the 7th harmonic is injected into the voltage sources. As the main frequency of the voltage source is 50Hz the harmonic frequency is 350Hz. Va7 Vb7 (10) Vc7 = 326.6 *0.05 0, f = 350Hz The frequency analysis of the current waveforms has been depicted in Fig. 8. 4.1. 3rd Harmonic In this case the 3rd harmonic is injected into the voltage sources. As the main frequency of the voltage source is 50Hz the harmonic frequency is 150Hz. According to the standards the magnitude of the harmonics should be less than 5% of the main frequency magnitude. Two cases can assumed here. In the 1st case the stator windings are not grounded but in the second case the stator winding is star connected and grounded. The voltages that are applied to the stator 3 phases are as follows (not grounded): Va3 = 326.6 *0.05 0, Vb3 (8) Vc3 f = 150Hz The analysis results are shown in Fig. 6. In case of an ungrounded stator winding the currents due to the 3 rd harmonic are not able to flow according to Kirchhoff s law. triplen harmonics are zero-sequence harmonics that are multiples of third harmonic and they have no effect on torque pulsation. Fig. 6: FFT analysis of Ib:with 3rd harmonic 4.2. 5th Harmonic In this case the 5th harmonic is injected into the voltage Sources. As the main frequency of the voltage source is 50Hz the harmonic frequency is 250Hz. According to the standards the magnitude of the harmonics should be less than 5% of the main frequency magnitude. Va5 = 326.6*0.05 0, Vb5 = 326.6* 0.05 0, (9) Vc5 = 326.6* 0.05 0, f = 250Hz Fig. 8: FFT analysis of Ib: with 7th harmonic 4.4. All Harmonics In this section all the above mentioned harmonics are injected simultaneously into the stator windings. The stator winding currents has been depicted in Fig. 9. Fig. 9: FFT analysis of Ib: with all harmonics 5. Effect of Flicker In this section the effect of voltage flicker on the performance of induction motor was investigated. A voltage flicker is a fluctuation of voltage with frequency of about 10Hz as shown in fig. 10. The loads like electric arc furnaces (EAF) causes to the voltage flicker on the terminal of load. For simulation of the effects of this type of voltage disturbance was injected. A voltage flicker with modulation index, m=0.15 to the induction motor. The speed and mean of torque and current of phase B shown in fig. 10. it can be seen from figures that torque fluctuate is as non sinusoidal with frequency 20 Hz. I-385

Fig.10: Flicker effect: vol. source, speed and mean of torque 6. Conclusions This study has investigated the negative effects of three phase unbalanced sinusoidal voltage over balanced nonsinusoidal voltage on the performance of 20HP, squirrel cage induction motor, focusing on the efficiency, line currents and power factor. The main conclusions from the study are (i) efficiency of the motor under three-phase unbalanced voltage is lower than the efficiency at balanced non-sinusoidal voltage, (ii) current drawn by the motor under unbalanced supply is higher, (iii) lower power factor is obtained by use of non sinusoidal supply, and (iv) it should additionally paid per year to the electricity supplier due to voltage unbalance in one motor because of reduction of efficiency. As the harmonics in the voltage source can cause excessive losses, extra noise and pulsating torque detecting harmonics in the voltage applied is important. The frequency analysis of the stator currents can be used for detection. In the case of unbalanced voltages the efficiency and average output torque of the motor would decrease and the ripple would increase significantly destructing the motor application. In order to detect unbalance condition torque frequency analysis can be used. In case of an unbalanced voltage with harmonics these quantities still work properly towards detection purpose.it was being seen from effect of flicker that torque and speed have damaged swings. motors with eccentric rotors. I. Analytical model, IEE Proceedings Electric Power Applications, Volume: 143, No. 3, Page(s): 193-201, May 1996. [5] Smith, A.C., Dorrell, D.G., Calculation and measurement of unbalanced magnetic pull in cage induction motors with eccentric rotors. II. Experimental investigation, IEE Proceedings Electric Power Applications, [6] NEMA Standard MG1-Motor and Generators, 1987. [7]C. Y. Lee, Effects of unbalanced voltage on the operation performance of a three-phase induction motor, IEEE Trans. on Energy Conversion, Vol. 14, No. 2, 1999, pp. 202-208. [8]P. Pillay, P. Hoffmann and M. Manyage, Derating of induction motors operating with a combination of unbalanced voltages and over or under voltages, IEEE Trans. on Energy Conversion, Vol. 17, No. 4, December 2002, pp. 485-491. [9]. Faiz, H. Ebrahimpour and P. Pillay, Influence of unbalanced voltage on the steady-state performance of a threephase squirrel-cage induction motor, Accepted for publication in IEEE Trans. on Energy Conversion. [10] N. Mohan, T. Undeland, and W. Robbins, Power Electronics, Converters,Applications and Design. New York: Wiley, 1989, p. 328. [11] Jesus M. Corres, Javier Bravo, Francisco J. Arregui,, and Ignacio R. Matias," Unbalance and Harmonics Detection in Induction Motors Using an Optical Fiber Sensor", IEEE Sensors Journal, Vol. 6, NO. 3, June 2006, page 607. [12] Lie Xu, Yi Wang, Dynamic modeling and control of DFIG-Based wind turbines under unbalanced network conditions, IEEE trans. on Power Systems, vol.22, pp. 314 323, 2007. [13] T.K.A. Brekken, N. Mohan, Control of a doubly fed Induction wind generator under unbalanced grid voltage conditions, IEEE trans. on Energy Conversion, vol.22, pp. 129 135, 2007 [14] M.G.A. Ioannides, New approach for the prediction and identification of generated harmonics by induction generators in transient state, IEEE trans. on Energy Conversion, vol.10, pp. 118 125, 1995. [15] R. B. Stincescu, P. Viarouge, J. Cros, I. Kamwa, A general approach of space and time harmonics interactions in induction motors, Int. Conf. on Electric Machines and Drives, pp. 366 368, 1999. [16] X. Liang, Y. Luy, Harmonic Analysis for Induction Motors, Canadian Conf. on Electrical and Computer Engineering, pp.172 177, 2006. 7. References [1] O. Souto, J. Oliveira, and L. Neto, Induction motors thermal behavior and life expectancy under nonideal supply conditions, in IX Int. Conf.Harmonics and Quality of Power, Orlando, FL, 2000. [2] Condition monitoring of stator faults in induction motors: Part II- A more sensitive indicator of inter-turn shortcircuits fault in stator windings under unbalanced supply voltage., proposed for the same conference. [3] Alwash, J.H.H., Ikhwan, S.H., Generalised approach to the analysis of asymmetrical three-phase induction motors, IEE Proceedings Electric Power Applications, Volume: 142, Issue: 2, Page(s): 87-96, March 1995. [4] Smith, A.C., Dorrell, D.G., Calculation and measurement of unbalanced magnetic pull in cage induction I-386