SIMULATION VERIFICATION OF DYNAMIC VOLTAGE RESTORER USING HYSTERESIS BAND VOLTAGE CONTROL

Similar documents
Mitigation of voltage sags/swells unbalanced in low voltage distribution systems

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

ISSN Vol.07,Issue.21, December-2015, Pages:

Power Quality Improvement using Hysteresis Voltage Control of DVR

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

Unit.2-Voltage Sag. D.Maharajan Ph.D Assistant Professor Department of Electrical and Electronics Engg., SRM University, Chennai-203

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

ISSN Vol.03,Issue.11, December-2015, Pages:

Simulation and Implementation of DVR for Voltage Sag Compensation

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

Simulation of Dynamic Voltage Restorer Using Matlab to Enhance Power Quality in Distribution System

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

Mitigation of voltage sag by using AC-AC PWM converter Shalini Bajpai Jabalpur Engineering College, M.P., India

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

COMPENSATION OF VOLTAGE SAG USING LEVEL SHIFTED CARRIER PULSE WIDTH MODULATED ASYMMETRIC CASCADED MLI BASED DVR SYSTEM G.Boobalan 1 and N.

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Protection from Voltage Sags and Swells by Using FACTS Controller

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

Improvement of Power Quality Using a Hybrid Interline UPQC

DYNAMIC VOLTAGE RESTORER (DVR) FOR VOLTAGE SAG COMPENSATION WITH FUZZY LOGIC CONTROLLER. Chennai, Tamilnadu, India. Chennai, Tamilnadu, India.

Mitigation of Voltage Sag/Swell by Using Battery Energy Storage DVR for Induction Motor Drive Applications

Investigation of Dynamic Voltage Restorer for Compensation of Voltage Sag and Swell

Voltage Sag Mitigation of DVR using Matlab Simulation

OVERVIEW OF DVR FOR POWER QUALITY IMPROVEMENT

Design and Development of DVR model Using Fuzzy Logic Controller for Voltage Sag Mitigation

Design and Simulation of Dynamic Voltage Restorer (DVR) Using Sinusoidal Pulse Width Modulation (SPWM)

Multi level DVR with Energy Storage System for Power Quality Improvement

FUZZY LOGIC CONTROL BASED DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT IN DISTRIBUTION SYSTEM

Voltage Quality Enhancement in an Isolated Power System through Series Compensator

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

DYNAMIC VOLTAGE RESTORER USING THREE PHASE AC-AC CONVERTER

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Power Quality Improvement By Using CHB Inverter Based DVR

IMPROVEMENT OF POWER QUALITY USING CUSTOM POWER DEVICES

MITIGATION OF VOLTAGE SAG IN A DFIG BASED WIND TURBINE USING DVR

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Performance of DVR under various Fault conditions in Electrical Distribution System

Compensation of Unbalanced Sags/Swells by Single Phase Dynamic Voltage Restorer

Improvement of Power Quality using Unified Power Quality Conditioner with Distributed Generation

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Mitigation of Voltage Sag and Swell Using Dynamic Voltage Restorer

Compensation of Balanced and Unbalanced voltage disturbance using SRF controlled DVR

SRF CONTROLLED DVR FOR COMPENSATION OF BALANCED AND UNBALANCED VOLTAGE DISTURBANCES

Power Quality improvement of a three phase four wire system using UPQC

Compensation of Different Types of Voltage Sags in Low Voltage Distribution System Using Dynamic Voltage Restorer

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

High Frequency Link-Dynamic Voltage Restorer with Fuzzy Logic Controller

Simulation of a Dynamic Voltage Restorer to Compensate Voltage Sag for Improving Power Quality

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

A REVIEW PAPER ON REGULATION TECHNIQUE FOR VOLTAGE SAG AND SWELL USING DVR

Study & Comparison of Various Topologies of Dynamic Voltage Restorer & Its type: a Review

A CONTROL TECHNIQUE FOR INSTANT MITIGATION OF VOLTAGE SAG/SWELL BY DYNAMIC VOLTAGE RESTORER

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

Design of Dynamic Voltage Restorer for three phase network as steady state device in the Distribution System

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

A new integration method of IPQC as Zeta converter based DVR to improve the Power Quality in DG network

Mitigation of Fault in the Distribution System by using Flexible Distributed Static Compensator (FD-STATCOM)

Voltage Sag, Swell And Interruptions Compensation Based On Feed Forward Backpropagation Network Using Dynamic Voltage Restorer

Power Quality and the Need for Compensation

World Journal of Engineering Research and Technology WJERT

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

A Power Control Scheme for UPQC for Power Quality Improvement

New Topology of a Three Phase Dynamic Voltage Restorer (DVR) for Voltage Swells Mitigation in Electrical Distribution System

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

ICCCES Application of D-STATCOM for load compensation with non-stiff sources

MODELLING & SIMULATION OF ACTIVE SHUNT FILTER FOR COMPENSATION OF SYSTEM HARMONICS

Voltage Sags in Distribution Systems with Induction Motor Loads Fed by Power Converters and Voltage Mitigation using DVR and D-STATCOM

Synchronous Reference Frame Theory (SRF) along with PI Controller Based Dynamic Voltage Restorer

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

II. RESEARCH METHODOLOGY

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

Improvement of Power Quality Using a Hybrid UPQC with Distributed Generator

Voltage Sag and Mitigation Using Dynamic Voltage Restorer (DVR) System

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Mitigation of Power Quality Problems Using DVR in Distribution Network for Welding Load

DESIGN AND DEVELOPMENT OF SMES BASED DVR MODEL IN SIMULINK

CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

PERFORMANCE OF DVR UNDER VOLTAGE SAG AND SWELLS CONDITIONS FOR POWER QUALITY IMPROVEMENTS

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

ITEE Journal. Information Technology & Electrical Engineering International Journal of Information Technology and Electrical Engineering

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Design Requirements for a Dynamic Voltage Restorer for Voltage Sags Mitigation in Low Voltage Distribution System

COMPARITIVE STUDY ON VOLTAGE SAG COMPENSATION UTILIZING PWM SWITCHED AUTOTRANSFORMER BY HVC

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

Modeling and Analysis of a Nonlinear Adaptive Filter Control for Interline Unified Power Quality Conditioner

Mitigation of Voltage Sag using DVR and PI Controller

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

Compensation of Balanced and Unbalanced voltage disturbance using SRF controlled DVR

Transcription:

SIMULATION VERIFICATION OF DYNAMIC VOLTAGE RESTORER USING HYSTERESIS BAND VOLTAGE CONTROL 1 R V D Rama Rao*, 2 Dr.Subhransu Sekhar Dash, Assoc. Professor, Narasaraopeta Engineering College, Narasaraopet 522 601, India Phone: +919908740746, Email: ramrvd@yahoo.com Professor, SRM University, Chennai, India Phone: +919884356933, Email: munu_dash_2k@yahoo.com 3 K. Ramash Kumar, Department of Electrical and Electronics Engineering, A.M.S.College of Engineering, Chennai -55,India Phone: +91-9894910778, Email: ramash1210@yahoo.co.in Abstract - Dynamic Restorer (DVR) is one of the custom power devices that are used as an effective solution for the protection of sensitive loads against voltage disturbances in power distribution system. The efficiency of the DVR depends on the performance of the efficiency control technique involved in switching the inverters. Unlike previous approaches, this paper presents a hysteresis voltage control technique of DVR based on unipolar Pulse Width Modulation (PWM). The hysteresis voltage control has a very fast response, simple operation and variable switching frequency. To evaluate the quality of the load voltage during the operation of DVR, it is controlled by hysteresis voltage control techniques with various Hysteresis Band (HB). The validity of proposed method and achievement of desired compensation are confirmed by the results of the simulation in MATLAB/ SIMULINK. Key words - Dynamic Restorer (DVR), hysteresis voltage control, Total Harmonic Distortion (THD), Hysteresis Band. 1. Introduction Power quality problems in industrial applications concern a wide range of disturbances, such as voltage sags and swells, flicker, interruptions, harmonic distortion. Preventing such phenomena is particularly important because of the increasing heavy automation in almost all the industrial processes. High quality in the power supply is needed, since failures due to such disturbances usually have a high impact on production costs [1-3]. sag/swell that occurs more frequently than any other power quality phenomenon is known as the most important power quality problems in the power distribution systems. IEEE 519-1992 and IEEE 1159-1995 describe the voltage sags /swells as shown in Fig.2. sag is defined as a sudden reduction of supply voltage down from 90% to 10% of nominal. According to the standard, a typical duration of sag is l0 ms to 1 minute. On the other hand, voltage swell is defined as a sudden increasing of supply voltage up1l0% to 180% in rms voltage at the network fundamental frequency with duration from 10 ms to 1 minute. sag/swell often caused by faults such as single line-to-ground fault, double line-toground fault on the power distribution system or due to starting of large induction motors or energizing a large capacitor bank. sag/swell can interrupt or lead to malfunction of 1

any electric equipment that is sensitive to voltage variations. The Dynamic Restorer (DVR) has been proposed to protect sensitive loads from such voltage sags/swell. The DVR is connected in series with the sensitive load or distribution feeder and is capable of injecting real and reactive power demanded by the load during voltage sag/swell compensation. The output of the DVR inverter is usually provided with an output LC filters to attenuate the harmonic contents appearing in injected voltage. The filter parameters are designed according to certain design aspects such as depth of the sag to be mitigated and the load voltage [4]. This paper presents a Hysteresis Control technique based on bipolar and unipolar PWM to improve the quality of load voltage. The hysteresis voltage control has not been investigated on DVR. The proposed method is validated through modeling in MATLAB/Simulink. energy storage unit can become a limiting factor in the disturbance compensation process especially for sags of long duration. Fig. 1. Typical schematic of a power system Compensated by DVR. 2. Dynamic Restorer (DVR) A Dynamic Restorer (DVR) is a recently proposed series connected solid-state device that injects voltage into the system in order to regulate the load side voltage. The DVR was first installed in 1996 [5]. It is normally installed in a distribution system between the supply and the critical load feeder [6]. Its primary function is to rapidly boost up the loadside voltage in the event of a disturbance in order to avoid any power disruption to that load [7-8]. There are various circuit topologies and control schemes that can be used to implement a DVR. In addition to voltage sags and swells compensation, DVR can also perform other tasks such as: line voltage harmonics compensation, reduction of transients in voltage and fault current limitations. The general configuration of the DVR consists of an Injection/Booster transformer, a Harmonic filter, a Source Converter (VSC), DC charging circuit and a Control and Protection system as shown in Fig. 1. In most sag correction techniques, the DVR is required to inject active power into the distribution line during the period of compensation. Hence, the capacity of the Fig.2. Reduction Standard of IEEE Std. 1159-1995. 3. DVR Power Circuit The power circuit of the DVR is shown in Fig.3. The DVR consists of mainly a three-phase Sourced Converter (VSC), a coupling transformer, passive filter and a control system to regulate the output voltage of VSC. 3.1. Source Converter (VSC) A voltage-source converter is a power electronic device, which can generate a sinusoidal voltage with any required magnitude, frequency and phase angle. This converter injects a dynamically controlled voltage in series 2

with the supply voltage through three singlephase transformers to correct the load voltage. It consists of Insulated Gate Bipolar Transistors (IGBT) as switches. The switching pulses of the IGBT are the output from the hysteresis voltage controller. Fig.3.Power Circuit of a Typical DVR. 3.2. Coupling Transformer Basic function is to step up and electrical isolation the ac low voltage supplied by the VSC to the required voltage. In this study single-phase injection transformer is used. For three phases DVR, three single-phase injection transformers can be used. Several control techniques have been proposed for voltage sag compensation such as pre-sag method, in-phase method and minimal energy control. 4.1. Pre-Sag Compensation Technique In this compensation technique, the DVR supplies the difference between the sagged and pre-sag voltage and restores the voltage magnitude and the phase angle to the nominal pre sag condition. The main defect of this technique is it requires a higher capacity energy storage device. Fig. 4(a) shows the phasor diagram for the pre-sag control strategy. In this diagram, Vpre-sag and VSag are voltage at the point of common coupling (PCC), respectively before and during the sag. In this case VDVR is the voltage injected by the DVR, which can be obtained as [7]: VPre-Sag=VL, VSag=VS and VDVR=Vinj --- (1) Vinj = VPre-Sag - VSag --- (2) --- (3) 3.3. A C-Filter 4.2. In-phase compensation technique A Passive filter consists of a capacitor that is placed at the high voltage side of coupling transformer. This filter rejects the switching harmonic components from the injected voltage. In this technique, only the voltage magnitude is compensated. VDVR is in-phase with the left hand side voltage of DVR. This method minimizes the voltage injected by the DVR, unlike in the pre-sag compensation. Fig. 4(b) shows phase diagram for the in-phase compensation technique. 3.4. Control Method The aim of the control scheme is to maintain a balanced and constant load voltage at the nominal value under system disturbances. In this paper, control system is based on hysteresis voltage control. 4. Conventional Control Strategies VDVR=Vinj --(4) 4.3. Energy optimization technique Pre-sag compensation and in-phase compensation must inject active power to loads almost all the time. Due to the limit of energy storage capacity of 3

DC link, the DVR restoration time and performance are confined in these methods. The fundamental idea of energy optimization method is to make injection active power zero. In order to minimize the use of real power the voltages are injected at 90 phase angle to the supply current. Fig.4 shows a phasor diagram to describe the Energy optimization Control method. The selection of one of these strategies influences the design of the parameters of DVR. In this paper, the control strategy adopted is Presag compensation to maintain load voltage to pre fault value. 5. Hysteresis Control In this paper, hysteresis voltage control is used to improve the load voltage and determine switching signals for inverters gates. A basic of the hysteresis voltage control is based on an error signal between an injection voltage (Vinj) and a reference voltage of DVR (Vref), which produces proper control signals. There is Hysteresis Band (HB) above and under the reference voltage and when the difference between the reference and inverter voltage reaches to the upper (lower) limit, the voltage is forced to decrease (increase) as shown in Fig.5. (a) Pre-sag compensation technique. Fig.5.Hysteresis band voltage control. (b) In-phase compensation technique. Fig.6. Single-phase full bridge inverter. (c) Energy optimized compensation technique. Fig.4. Conventional control strategies. T1+T2=Tc=1/fc ------(5) Where HB and fc are Hysteresis Band and switching frequency respectively. The HB that has inversely proportional relation to switching frequency is defined as the difference between VH and VL (HB=VH-VL). In comparison with the other PWM methods, the hysteresis voltage control has a 4

very fast response, a simple operation and a variable switching frequency. Fig.6 shows a single-phase full bridge inverter that is connected in series to a sensitive load. The inverter can be controlled in unipolar or bipolar PWM method [9-10]. In the unipolar modulation, four voltage bands are used to achieve proper switching states to control the load voltage. The first upper and lower bands (HB1) are used when the output current is changed between (+Vdc & 0) or (-Vdc or 0). The second upper and lower bands (HB2) are used to change the current level Fig.7 (a). There are four switching states for switches (S1, S2) and (S3, S4) as shown in Fig.7 (b). The switching functions of both B and C phases in bipolar and unipolar Hysteresis voltage control are determined similarly using corresponding reference and measured voltage band (HB). voltage. Here we consider two different cases. In Case 1, the unbalanced voltage sag is simulated. To demonstrate the performance of the proposed method we assumed voltage swell condition in Case 2. A. Case 1 In this case, we assume that there is a 30% three-phase voltage sag with +30 phase jump in phase-a in supply voltage that is initiated at 0.1s and it is kept until 1.8 s. The outcome of voltage sag compensation considering hystersis voltage control based on unipolar switching for HB1=0.005 and HB2=0.007 is demonstrated in Fig.8. Fig.8 (b) shows the serial injected voltage components. Moreover, the compensated load voltage is shown Fig.8 (c). As it can be seen from the results, the DVR is able to produce the required voltage components for different phases rapidly and help to maintain a balanced and constant load voltage at the nominal value (400 V). (a) Supply voltages. (a) Output voltage with two lower and higher bands. (b) Injected voltage, VDVR. (b) Switching Signals. Fig.7. Unipolar Hysteresis Control. 6. Simulation Results The proposed method is validated by simulation results of MATLAB/Simulink. The system parameters are given in the Appendix. DVR with hysteresis voltage control is applied to compensate load (c) Load voltage, VL. Fig.8. Simulation result of DVR response to unbalance voltage sag (HB1=0.005, HB2=0.007). B. Case 2 5

In the second case, performance of DVR for a voltage swell condition is investigated. Here, an unbalance voltage swell with 30% three-phase voltage swell with +30 phase jump in phase-a which starts at 0.1s and ends at 1.8s is considered. Fig.9 shows the result of voltage swell compensation considering hysteresis voltage control based on unipolar switching for HB1=0.005 and HB2=0.007. The injected voltage that is produced by DVR to correct the load voltage is shown in Fig.9 (b). As it can be seen from Fig.9, DVR is able to correct the voltage swell by injecting negative three phase voltage components. 8.Appendix Table.1: Case Study Parameters. PARAMETERS VALUE 400V SUPPLY VOLTAGE VDC,CF 200V,500ΜF 96V/240V SERIES TRANSFORMER 0.004+J0.008 ZTRANS 31.84Ω,0.139H RLOAD,LLOAD References [1] Banaei, M.R. Hosseini, S.H. Khanmohamadi, S. (a) Supply voltages. and Gharehpetian, G.B., Verification of a new energy control strategy for dynamic voltage restorer by simulation, Simulation Modelling Practice and Theory (ELSEVIER), 2005, pp: 113-125. [2] (b) Injected voltage, VDVR. Boonchiaml, P. Apiratikull, p. and Mithulananthan, N., Detailed Analysis of Load Compensation for Dynamic Restorer, TENCON IEEE 2006. 14-17 Nov. pp: 1-4. [3] Chen, S. Joos, G. Lopes, L. and Guo, W. A Nonlinear Control Method of Dynamic Restorers, Power Electronics Specialists Conference (c) Load voltage, VL. Fig.9. Simulation result of DVR response to unbalance voltage swell (HB1=0.005, HB2=0.007). 7. Conclusion This paper has been successfully demonstrated a hysteresis voltage control technique based unipolar Pulse Width Modulation (PWM) For Dynamic Restorer to improve the quality of load voltage. The validity of proposed method is approved by results of the simulation in MATLAB/ Simulink. The result simulation shows that DVR can compensate Sag and Swell of the distribution system. IEEE, 23-27 June 2002. Vol.1, pp: 88-93. [4] Ezoji, H. Sheikholeslami, A. lessan,s., Hysteresis Control of DVR Based on Unipolar PWM, accepted in International Conference on Industrial Technology (IEEE-ICIT09), Australia,2008. [5] Fawzi, A. Modeling and Simulation of Dynamic Vltage Restorer (DVR) Based on Hysteresis Control, The 33rd Annual Conference of the IEEE Industrial Electronics Society (IECON) Nov. 5-8, 2007, Taipei, Taiwan, pp: 1726-1731. 6

[6] Fitzer, C. Barnes, M. and Green, P., Sag Detection Technique for a Dynamic Restorer, IEEE Transactions on industry applications, February 2004. Vol. 40, NO. 1, pp: 203-212. [7] Ghosh,A. Ledwich,G., Structures and Control of A Dynamic Regulator (DVR), IEEE Confrance, pp:1027-1032. [8] Hannan, M.A. and Mohamed, A., Modeling and analysis of a 24-pulse dynamic voltage restorer in a distribution system, Research and Development, IEEE 2002 SCOReD. July 2002, pp: 192-195. [9] Jurado,F. Valverde,M. Carpi,J, Sag Correction by Dynamic Restorer Based on Fuzzy Logic Control, May, mai 2003 IEEE, pp:421424. [10] Kale, M. Ozdemir, E., An adaptive hysteresis band current controller for shunt active power filters, Electric Power Systems Research 73, Elsevier. 2005, pp: 113 119. 7