Olympia Plus Sports Ceiling Impact Class 1A

Similar documents
ROCKFON System Olympia Plus

Rockfon System OlympiaPlus A Impact 1A

CI/SfB. October RockLink Integra. Installation system

Installation Guide. Rockfon Eclipse

Installation guide. ROCKFON VertiQ. ROCKFON System T, ROCKFON System HAT. Impact-resistant and high impact-resistant acoustic wall panel solutions

Installation Guide. Rockfon Eclipse

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version

METALWORKS TARTAN PANELS General Installation Instructions

OWAtecta. OWA metal ceilings. OWAtecta Metal ceilings

CI/SfB. January Rockfon Color-all

CEILING SYSTEMS. MADERA VECTOR Semi-concealed system on exposed 24mm grid. Technical Data Sheet. [Between us, ideas become reality.

Perforated acoustic gypsum products

AXIOM Classic Trim. Assembly and Installation Instructions

AXIOM Classic Trim Installation Instructions

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

Ceiling mounting application, U support and bracket. Standard mounting of a cable tray with support, type US.., and suitable support bracket, type AW.

CertainTeed Ceilings

INTERIOR INSTALLATION

Standard Solo 8 planks in maple veneer with aligned 1/2 reveal create a panelized appearance. 1/2 Reveal. Plank thickness 5/8 (16 mm)

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

AXIOM KE CANOPY Installation Guide

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

Technical Data VARIABLES

ARMSTRONG METALWORKS BAFFLES Installation Guide

Wall mounting with holding profile

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

How to Install the QuickHang Installation Kit

Light Structural Main Runner Light Structural Infill Tees. Straight Connector. Strut Structural Tee thread

Ceiling Installation

Technical Data VARIABLES

Hospital Grade Welded Ceiling System

Art and Picture Hanging Rail Systems SYSTEMS. Display with Elegance

Colourful acoustic solutions

WOODWORKS. Linear Solid Panels. Installation Instructions CEILING SYSTEMS. 1. General

ECOPHON Focus Ds 4x4 Installation Manual

SAVE THESE INSTALLATION INSTRUCTIONS

Overlapping panel Cladding system made up of horizontal overlapping panels fixed on a wooden or metal wall-mounted framework.

METALWORKS Concealed. Installation Instructions

Classic Exposed Tee System (24" x 24", 24" x 48", and 24" x 72") Floating Clouds and Perimeter Wall Attachment

WOODWORKS Access Hook-on System

The fast track. in cable management systems for power, voice and data cables. Reduce installation time up to 50%

Installation Manual 0318

DUALCASE VERSATILE ALUMINIUM SIGN SYSTEM

Tools needed. Supplies Needed

INSTALLATION INSTRUCTIONS - CEILING POWER TRAK, HANGER HOOKS AND RACKS I. CONTENTS CEILING POWER TRAK KIT

FOR PROFESSIONAL GARAGE DOOR INSTALLERS

ON-CENTER LINEAR LIGHTING WITH XAL Layout Guide

Lightplane 3.5 Recessed

INTERIOR INSTALLATION

Cell Ceiling. Endless possibilities

T-GRID SYSTEM WIDE CLEANROOM CEILING GRID SYSTEM

modular/panel-built sauna kit

Perforation Options for Rockfon Specialty Metal Ceilings

NONIUS ceiling SUSPENSION SYSTEM

Panel Grille Suspended Ceiling Installation Guide

Technical Data VARIABLES

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS

Trim (Aluminum Substrate)

WOODWORKS Grille System

CURVING PROFILES & CONCAVE and CONVEX CURVING STUDS 60x27mm

STABILA compact lasers: For all finishing trades.

WoodWORKS Channeled Plank

INSTALLATION, I O OPERATION & MAINTENANCE M A N U A L. Flowline. Architectural Linear Diffusers

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE

Commercial Systems

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7

Connect by Ecophon engineered for your convenience

Updates Interior compensation of varying infill thicknesses. THERM + V curtain walls

metalworks Vector Assembly and Installation Instructions

Installing Novi Siding Trim

installation guide Villa

CSI Section DMI Light Gage Structural Steel Framing Systems. Blocking Fire Rated Pre-cut (Proprietary) Furring Wall Preservative Treated

Connect by Ecophon engineered for your convenience

FORMATIONS Curves Clouds with AXIOM VECTOR Trim and Suspension System

modular/panel-built sauna kit

Elam -range of products: Vanha Porvoontie 36 FIN MÄNTSÄLÄ Phone: +358 (0) Fax: +358 (0)

WOODWORKS Concealed. Assembly and Installation Instructions

INSTALLATION INSTRUCTIONS FOR PLASCORE F5075 FRAME WALL

GE LED Edgelit Panel. PREMIUM version. GE Lighting DATA SHEET. Product information. Features and Benefits. Application areas

INSTALLATION INSTRUCTIONS FOR HAND OPERATED MODELS: 170, 171-R, 171-N, 172, 260

SAGIREV Installation Manual

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

Interiors by INEXA TNF. Profile Selection. Craftsmen to the world s finest ships

Create conversation areas

Sky FactoryTM toll free

Table and Furniture Base Fittings Plinth Adjusting Fittings

Installation Instructions

Sky FactoryTM toll free

Product Guide Specification

SYSTEMS. Between us, ideas become reality. wood. ceilings

Metawell acoustic element

SUBMITTAL SHEET. Project Submittals by

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

Interior Equipment/Shop Fittings

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

Interior Equipment, Shop Fittings

ideaperfo ideatec INSTALLATION GUIDE advanced acoustic solutions

4300 Install Guide. Attention. Ceiling Accessories

Technical Note No. 028

ALLORA SWING PANEL INSTALLATION INSTRUCTIONS

Transcription:

Olympia Plus Sports Ceiling Impact Class 1A

Suspension system Exposed impact-resistant 50mm grid system 11 6 9 8 12 7 11 4 1 5 3B 3A 10 2 1. 50 mm main runner CMC 3050 2. 50 mm cross tee CMC 3054 3. Hold-down C-profile Long: CMC 5134 Short: CMC 5132 4. Rockfon Boxer/Samson panel 5. Grid cross connector CMC 3053 6. Grid wall connector CMC 1470 7. Nonius hanger CMC 3235 + 10200 8. Perimeter trim CMC 1470 9. Fire-resistant batten (top) Pinewood batten (bottom) 10. Straight C-profile connector CMC 5139 11. Angled C-profile connector CMC 5138 12. Grid coupling CMC3051

Products used Exact size (mm) Module dimensions (mm) 1166 x 1166 1200 x 1200 Boxer (40 mm) Samson (40 mm) Connecting a cross tee to a main runner. Suspension system description This high performance grid system is made from galvanized Z100 steel. The system consists of main runners, cross tees and perimeter trims. The profiles are painted white as standard.* The system is intended to be suspended from soffits using nonius hangers. The grid components have an exposed face width of 50mm. Grid cross connectors should be placed into cross tees and then hooked onto and mechanically fastened to main runners using self tapping screws 3.5 x 9.5mm (DIN 7504). At walls, the ends of the main runners and cross tees should be connected to the wall using grid wall connectors. The hold-down grid can be fitted after the Rockfon Boxer / Samson tile has been installed. * Other colours available on request. Tile compatibility The system is intended for use with Rockfon Samson and Boxer tiles. The main runner and the cross tee remain exposed after assembly. As a result of the space between the back of the ceiling tile and the bottom of the holddown grid, the tiles can be raised approximately 10 mm. Every tile can be removed by disconnecting the angled C-profile connector. 40 40 A-edge tile. Installing Rockfon Boxer / Samson. Hold-down grid The Rockfon tiles (40 mm thick) are held in place by a hold-down H frame. This is made from 2 x 2 lengths of C-profile. The two long C-profiles bridge the distance from main runner to main runner, whilst the two short C-profiles bridge the distance between the two long C-profiles. The short and the long C-profiles are connected together by the straight C-profile connector. Angled C-profile connectors are fitted to the end of the long C-profiles and clicked into the grooves in the main runners. The hold-down H frame should be installed symmetrically in the 1200 x 1200 mm module. NB: Pay special attention to the location of the main runner grid connectors, so that the angled C-profile connectors can be clicked in place.

Module dimensions This ceiling system has a module dimension of 1200 x 1200 mm. 1200 mm 1200 mm Perimeter trims There are two methods for connecting the ceiling to a wall. Both methods use perimeter trims. Depending on the technical requirements placed on the room, they can be fitted against a wall either with or without a batten. Grid component attached to a wall. Hold-down C-profile attached to a wall. Fit the grid wall connector to the main runner using self tapping screws. Fasten the connector to the wall using appropriate fixings. Fit the angled C-profile connector to the C-profile using self tapping screws. Fasten the connector to the wall using appropriate fixings.

Grid components The main runners should be suspended from the soffit using nonius hangers. The length of the nonius hangers can be adjusted. The centre-to-centre distance of both the main runners and the cross tees is 1200 mm. The maximum distance from the wall to a nonius hanger is 450 mm for each grid member. The distance between the nonius hangers for each grid member must not exceed 1200 mm. max. 1200 mm max. 450 mm Cross tees The cross tees should be placed at right angles to the main runners. The centreto-centre distance of the cross tees is the module width (1200 mm). Grid cross connectors should be connected to the ends of the cross tees. These should be screwed on to the main runner where the perforation on the top of the connector piece is located, as well as through the vertical side of the cross tees. Recommended screw: self-tapping, 3.5 x 9.5 mm (DIN 7504). 90 Cross tees are placed at right angles to the main runners. Cutting tiles to the correct size If necessary, the tiles can easily be cut to the correct size using a sharp knife.

Assembly The length of the nonius hangers can be adjusted. Suspension points The grid should be suspended using nonius hangers. The maximum distance from the wall to a nonius hanger is 450 mm. When using nonius hangers, the minimum suspension height is 200 mm. Larger suspension heights are possible. A larger suspension height makes it easier to fit the ceiling tiles. Ceiling layout Unless otherwise specified, the suspension system must be symmetrical within the room. If size (a) is used at the start of the longitudinal direction, then this size must also be used at the other end of the room. It is not recommended to fit tiles which have been cut to a length which is shorter than half the width or length of the tile. a b a b A symmetrical distribution of tiles gives the most attractive final result. Connection between the ceiling and a wall The battens and perimeter trims must be levelled against a wall (and be aligned). The distance between fixing points on a perimeter trim must not exceed 400 mm. For fire-resistant constructions, the perimeter trims must be attached directly against the wall or be fitted with fire-resistant battens. Connection between the ceiling and curved vertical surfaces When the ceiling connects with a curved vertical surface, pre-shaped and/or flexible perimeter trims must be used.

Demounting Demounting Rockfon tiles The tiles can be easily demounted. A hold-down H frame should be fitted above each Rockfon tile. Push the Rockfon tile upwards and click two of the four angled C-profile connectors out of the cross tees using the removal tool supplied or pliers or a hook. The tiles can now be removed from the grid system. The tiles can be easily demounted. Accessories Installing air handling and light fixtures A number of manufacturers supply a wide range of light and air handling fixtures whose dimensions are suitable for the various suspension systems. The suitable fixtures can be placed in and/or separately suspended at the desired positions in the grid system. If the fixtures are fitted in a tile, then extra precautions must be taken. Further information Resistance to corrosion The system meets corrosion class B in accordance with table 7 of the European product standard EN 13964. All the parts are made from Z100 steel (minimum zinc layer of 100 g/m 2 ). As a result, the system is suitable for use in rooms with a maximum relative humidity of 90% at a maximum temperature of 30 C.

THE ADVANTAGES OF OLYMPIA PLUS Excellent noise absorption of a Rockfon Boxer/Samson tile (α W = 1.00). Increased product lifespan due to optimum impact resistance (class 1A in accordance with EN 13964). Optimum fire safety (Euroclass A1). Quick and easy to assemble and demount. Tiles which are easy to remove. Modern appearance thanks to the module dimension 1200 x 1200 mm. 15-year product warranty. Olympia Plus is the result of close cooperation between Rockfon and Chicago Metallic. ACTIVATE YOUR CEILING Rockfon develop intelligent ceiling solutions which actively address a number of important issues in modern buildings and renovation projects. Rockfon products are known for their design, aesthetics and ease of installation; coupled with the key performance features of superior fire resistance and acoustics. This ensures that our ceiling solutions are among the highest performing, most cost effective and time efficient in today s interiors market. Subject to alterations in range and product technology without prior notice. Rockfon accepts no responsibility for printing errors. The comprehensive ceiling solution portfolio from Rockfon ensures that our customers are able to actively add value to the construction process, by ultimately creating superior interior environments. That is why we say ACTIVATE YOUR CEILING. 01/2011 Rockfon UK A trading division of Rockwool Limited 26-28 Hammersmith Grove London W6 7HA Tel: 020 8222 7457 Fax: 020 8222 7458 www.rockfon.co.uk