Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers

Similar documents
Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

Manufacturing Metrology Team

Large Field of View, High Spatial Resolution, Surface Measurements

Bringing Answers to the Surface

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

Dynamic Phase-Shifting Microscopy Tracks Living Cells

Surface Finish Measurement Methods and Instrumentation

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI)

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

The Fastest, Easiest, Most Accurate Way To Compare Parts To Their CAD Data

Chapter 7. Optical Measurement and Interferometry

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

ABC Math Student Copy. N. May ABC Math Student Copy. Physics Week 13(Sem. 2) Name. Light Chapter Summary Cont d 2

System Configuration 3D Optical Profi ler Dimensions SENSOFAR SENSOFAR-TECH, SL. TERRASSA SENSOFAR Japan Ltd.

Chapter 36: diffraction

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

SUPPLEMENTARY INFORMATION

Optical Performance of Nikon F-Mount Lenses. Landon Carter May 11, Measurement and Instrumentation

of surface microstructure

SENSOR+TEST Conference SENSOR 2009 Proceedings II

Microscopic Structures

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Chapter 25. Optical Instruments

PhD Thesis. Balázs Gombköt. New possibilities of comparative displacement measurement in coherent optical metrology

Asphere and Freeform Measurement 101

Laser Scanning for Surface Analysis of Transparent Samples - An Experimental Feasibility Study

Practical Flatness Tech Note

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Coherence radar - new modifications of white-light interferometry for large object shape acquisition

Bruker Optical Profilometer SOP Revision 2 01/04/16 Page 1 of 13. Bruker Optical Profilometer SOP

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Compare and Contrast. Contrast Methods in Industrial Inspection Microscopy. Application Note. We explain how to

Study of shear force as a distance regulation mechanism for scanning near-field optical microscopy

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

Non-contact 3D optical profiler

Simple interferometric fringe stabilization by CCD-based feedback control

Be aware that there is no universal notation for the various quantities.

ASM Webinar Digital Microscopy for Materials Science

Scanning Electron Microscopy

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

Point Spread Function Estimation Tool, Alpha Version. A Plugin for ImageJ

BIG PIXELS VS. SMALL PIXELS THE OPTICAL BOTTLENECK. Gregory Hollows Edmund Optics

Resolution. [from the New Merriam-Webster Dictionary, 1989 ed.]:

The End of Thresholds: Subwavelength Optical Linewidth Measurement Using the Flux-Area Technique

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Characterization of field stitching in electron-beam lithography using moiré metrology

Applications of Optics

Demo Pattern and Performance Test

LightGage Frequency Scanning Technology

ECEN 4606, UNDERGRADUATE OPTICS LAB

Diffraction. Interference with more than 2 beams. Diffraction gratings. Diffraction by an aperture. Diffraction of a laser beam

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D

Radial Polarization Converter With LC Driver USER MANUAL

Focusing X-ray beams below 50 nm using bent multilayers. O. Hignette Optics group. European Synchrotron Radiation Facility (FRANCE) Outline

nanovea.com PROFILOMETERS 3D Non Contact Metrology

Point Autofocus Probe Surface Texture Measuring Instrument. PF-60 technical report

Super-Resolution and Reconstruction of Sparse Sub-Wavelength Images

Copyright 2000 Society of Photo Instrumentation Engineers.

Sensors and Metrology - 2 Optical Microscopy and Overlay Measurements

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Modulation Transfer Function

By: Louise Brown, PhD, Advanced Engineered Materials Group, National Physical Laboratory.

Bias errors in PIV: the pixel locking effect revisited.

Application Note (A11)

Instructions for the Experiment

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Lithography. Taking Sides to Optimize Wafer Surface Uniformity. Backside Inspection Applications In Lithography

Imaging Optics Fundamentals

Specifying and Measuring Nanometer Surface Properties. Alson E. Hatheway

Physics 4. Diffraction. Prepared by Vince Zaccone For Campus Learning Assistance Services at UCSB

M4 TORNADO PLUS. Innovation with Integrity. Super Light Element Micro-XRF Spectrometer. Micro-XRF

University of Huddersfield Repository

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Fabrication of Probes for High Resolution Optical Microscopy

Errors Caused by Nearly Parallel Optical Elements in a Laser Fizeau Interferometer Utilizing Strictly Coherent Imaging

Lecture 20: Optical Tools for MEMS Imaging

Physics 1C Lecture 27B

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

Comparison of resolution specifications for micro- and nanometer measurement techniques

Introduction of New Products

How to Optimize the Sharpness of Your Photographic Prints: Part I - Your Eye and its Ability to Resolve Fine Detail

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

Contouring aspheric surfaces using two-wavelength phase-shifting interferometry

Fast Laser Raman Microscope RAMAN

J. C. Wyant Fall, 2012 Optics Optical Testing and Testing Instrumentation

Diffraction, Fourier Optics and Imaging

Extended vertical range roughness measurements in non-ideal environments

Diffraction Single-slit Double-slit Diffraction grating Limit on resolution X-ray diffraction. Phys 2435: Chap. 36, Pg 1

Testo SuperResolution the patent-pending technology for high-resolution thermal images

Optical design of a high resolution vision lens

Properties of Structured Light

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Fast Laser Raman Microscope RAMAN

DetectionofMicrostrctureofRoughnessbyOpticalMethod

ADVANCED OPTICS LAB -ECEN 5606

Transcription:

Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers ContourGT with AcuityXR TM capability White light interferometry is firmly established as being among the fastest, most accurate, and most versatile surface measurement techniques available to researchers and manufacturers. Traditionally, interferometric technology does have a well-known limitation in lateral resolution compared to a couple of other techniques. This application note details Bruker s development of an interferometric measurement mode, AcuityXR, that effectively overcomes this optical diffraction limit, resolving greater detail in many surfaces without compromising the many other benefits of white light interferometry. Optical Interferometry and Lateral Resolution Limits Interferometric methods provide among the fastest, most accurate, and most versatile surface measurements. 1,2 The measurement principal is relatively simple: split a single beam of light into two parts; reflect one part off a highquality reference surface and one part from the test surface; recombine the light and measure either the phase of the resulting signal or its contrast as the test object moves through focus. The result is a series of optical fringes that correspond to the topography of the sample surface, much like a topographic map for geographic areas. Using this technique, vertical noise floors less than 0.01nm may be readily achieved using a standard commercial system, with measurement times on the order of a few seconds and virtually no setup time. One drawback of interferometry in certain situations, however, is a more limited lateral resolution as compared to atomic force microscope (AFM) or scanning electron microscope (SEM) systems. There are two potential limits on the lateral resolution of an optical system. The first is pixel-limited resolution, where two adjacent features are imaged into a single camera pixel, and thus there is no way to distinguish between the features in the final digitized image (see figure 1). The black lines represent camera pixels and the red curves are the images of perfect lines as spread out by the optical system. Since both the red curves are imaged onto the same pixel, only one bright spot would be observed rather than one for each feature. In this case, resolution may be increased by increasing the number of pixels in the imaging camera, though this is not always practical. Pixel-limited resolution is typically encountered at low microscope magnifications, such as 2.5X, 5X, or 10X where the optical resolution often exceeds the pixel resolution of the system.

Pixel Limited Diffraction Limited Figure 1: Illustration of pixel-limited resolution. The red bars represent the overall light collected in each pixel. The two adjacent features will not be distinguished because of inadequate camera pixel spacing. Another possible limitation to lateral resolution is an opticslimited one, where there are at least two camera pixels for each feature but where multiple features are so blurred by the optics that they still cannot be readily distinguished from each other (see figure 2). This is known as diffraction limited resolution. The diffraction-limited resolution δ is typically defined using the Sparrow criterion formula δ = 0.47λ / NA, where λ is the wavelength of light and NA is the numerical aperture of the optical system used to image the feature. For visibile-light microscope systems, including white-light interferometers, this limit is usually about 350 to 400nm. High-magnification objectives, such as 20X, 50X, and 115X typically produce diffraction-limited images. Often resolution may be increased by moving from a smaller magnification to a larger magnification. However, high-magnification objectives are both expensive and limited in the size of objects that can be imaged in a single field of view, making them less than ideal for many applications. Beating the Diffraction Limit Overcoming this diffraction limit would provide great advantages to the user of such an optical system. For instance, smaller features could be distinguished for any given microscope magnification, so that the field of view could be larger and the need for stitching together multiple images to fully characterize a surface would be less. Also, for the highest magnifications, where simply moving to a larger NA objective is not possible, interferometric techniques could continue to be used without resorting to the more difficult and costly AFM or SEM methods. Some of the primary applications where such a technique would be useful include: Defect detection on glass, silicon, plastic, or other substrates Examination of micro-scratches from polishing processes, such as for orthopedics or other finely ground surfaces Linewidth measurements of very small features Nanoscale roughness determination of smooth surfaces Figure 2: Illustration of diffraction-limited resolution. Features are wider than the camera pixel spacing but are blurred due to the optics of the system and in this case are barely separated. Distinguishing fine features and determining precise motions of MEMS devices Nanoscale quality control for medical implants, including optics, orthopedics, and monitoring devices Imaging of sub-cellular structures in biological applications In theory, one can reconstruct the object that has been imaged by an optical system. However, this requires that the optical system be perfectly known and that either no noise is present or it is perfectly characterized. Such knowledge of the system is generally impossible to obtain. In addition, such a reconstruction works only on a single image, and does not readily translate to a surface map generated by many such images, such as is the case for surface measurements using white light interferometry. Various methods have been proposed to overcome the limited lateral resolution of optical systems. 3,4 However, such methods have only been commercially successful in improving resolution when it is camera-pixel limited, such as is generally the case for satellite imagery or for reconstruction of scenes taken with a video camera. For improving diffraction-limited resolution, only a few very specific, well-controlled cases have been described in the literature. 5,6 To date, no commercially available system has solved this problem to provide real-time improvements in lateral resolution for a broad range of surfaces. A primary limitation of other proposed solutions has been the inability to enhance the signal from the small features without also enhancing noise in the system in such a way that it dominates the final results. Through extensive research and a novel combination of hardware and software techniques, Bruker s Nano Surfaces Division has overcome these challenges and has implemented a revolutionary measurement mode, AcuityXR, that can significantly enhance the lateral resolution for a broad class of measurements. AcuityXR works on any smooth surface in which the phase of the light is examined and used to calculate the surface from the white-light-interferometric signal. 2

AcuityXR Enhanced-Resolution Microscopy Technology Through advanced system modeling and the combination of multiple scans, AcuityXR produces a measurement with twice the number of pixels in the X and Y directions than is possible with a standard interferometric measurement. Greater detail is achieved for fine features in the measurement, such as more separated lines and sharper scratches or defects. There may be slight ringing near the edges of the field of view or near areas of missing surface data from the processing required to improve resolution, but this is a normal consequence of the mathematical algorithms used to enhance the resolution. The examples below detail several use cases where AcuityXR measurements provide significant benefits in detection capability or in quantification of key surface features. Case 1: Improved Metrology of Narrow Linewidths One obvious application of enhanced lateral resolution is to achieve superior measurement of narrow linewidth features. To test this, a sample with two 350nm lines, separated by 350nm were measured on a Bruker ContourGT X8 Optical Profiler System using standard Phase Shifting Interferometry (PSI) and AcuityXR PSI measurement modes. Figure 3 shows one measurement from each technique. First, one can clearly see that using the AcuityXR measurement, enough resolution is gained to reveal the full separation between the lines, whereas for the PSI image they are blurred enough that the surface height between the lines is not the same as the rest of the substrate. Also, fine details of the linewidth variation along the line are visible in the AcuityXR result and not apparent in the standard PSI result. The average linewidth calculated using PSI was just 300nm. Using AcuityXR mode, the average linewidth was 320nm. Though the AcuityXR result is still slightly smaller than listed on the standard, it can be adjusted based on exactly where the width is taken vertically along the line. In terms of numerical measurement performance, the standard deviation of linewidth for the PSI measurements was 35.1nm. For the AcuityXR PSI results, the standard deviation drops by nearly a factor of 7, to just 5.2nm. Similarly, when calculating the volume of the lines, the standard deviations for PSI and AcuityXR PSI measurements are.005µm3 and 0.001µm3 respectively, which is a factor of 5 improvement. Thus, significant gains in metrology capability are possible through the enhanced lateral resolution offered by AcuityXR. Standard PSI AcuityXR Figure 3: 350nm linewidth measurements taken with Standard PSI (left) with little feature separation and AcuityXR PSI (right), showing high levels of feature differentiation. 3

Case 2: Feature Separation Capability To truly test the limits of AcuityXR and it s ability to distinguish fine features, a linewidth standard of successively smaller lines, from 1µm to 100nm, was obtained. Bruker s exclusive 115X, 0.8NA microscope objective was used to provide maximum resolution on the linewidth standard. The lateral resolution of the optical system as determined by the Sparrow criterion is 314nm. Features down to 200nm can be easily distinguished both using PSI and AcuityXR PSI modes (see figure 4). However, greater detail and a better separation are clearly seen using the AcuityXR mode. The 150nm lines that can barely be distinguished using normal measurements are quite clearly separated using AcuityXR. Ultimately, at 130nm there was no separation at all visible using normal PSI measurement, while AcuityXR mode was able to show two distinct features. This apparent limit of the lateral resolution capability of AcuityXR enhanced measurements is approximately 2.5 times smaller than the lateral resolution expected from the Sparrow calculation. Standard PSI AcuityXR Figure 4: All the images have the same vertical scale of 2nm (red) to -8nm (blue). Standard PSI Measurements (left) and AcuityXR PSI Measurements (right) of 200nm (top), 150nm (middle), and 130nm (bottom) linewidth features. The two 130nm lines are indistinguishable in standard PSI measurements, but AcuityXR PSI is able to separate the two features. 4

Case 3: General Feature Clarity Often when examining surfaces, one wishes to identify scratches, defects, or other fine features without necessarily needing to perform gage studies or otherwise quantify each individual feature. For instance, this would be a nonsensical laboratory requirement when examining surface finish in orthopedics, medical implants, plastic substrates, or optics. We measured a variety of surfaces quickly using PSI measurement mode and AcuityXR PSI mode (see figure 5). In each case, the AcuityXR measurement demonstrates sharper features on the gratings and other small defects present in the images. This allows not just superior visual identification, but also a better capability for automatically locating, counting, and quantifying features based on width or height with Bruker s Vision software. Standard PSI AcuityXR Figure 5: Images taken with Standard PSI (left) and AcuityXR PSI (right) shows vast improvement in AcuityXR PSI in the ability to make images less pixilated while showing the proper structure on the sample. 5

Limitations of AcuityXR Mode While AcuityXR can measure many surfaces, it is limited to surfaces with local roughness less than approximately 20nm, where PSI or HDVSI measurement modes can measure the surface without problems. Rough surfaces, such as paper, roughly machined metal, or foams are not appropriate for AcuityXR. The additional noise caused by the rougher surfaces overwhelms the ability to accurately model the optical system s behavior. Also, surfaces with large amounts of missing data may suffer some ringing near the edges of the valid data when using AcuityXR, since the mathematics involved require contiguous surfaces for proper calculation. In general though, if PSI or HDVSI may be used to measure the surface, AcuityXR should show significant enhancement of fine features on the surface. Conclusions AcuityXR is a breakthrough technology available for most models of Bruker s optical profilers. It employs system modeling, low-noise measurements, and the combination of multiple surface scans. With this combination, the blur caused by the optical elements can be reduced and lateral resolution significantly enhanced. Greater detail can be seen in many surfaces. For narrow features, AcuityXR also offers significantly enhanced quantification of variations, making process control possible even on small structures. While AcuityXR is not suitable for all surfaces, for smooth, fine features it greatly enhances the measurement capability of the optical profiler. References 1. P. Caber, Interferometric Profiler for Rough Surfaces, Appl. Opt. 32: 3438 41 (1993). 2. J. Schmit and A. Olszak, High-Precision Shape Measurement by White- Light Interferometery with Real-Time Scanner Error Correction, Appl. Opt. 41: 5943 50 (2002). 3. S. Park, M. Park, and M. Kang, Super-Resolution Image Reconstruction: A Technical Overview, IEEE Signal Processing Magazine, May: 21 36 (2003). 4. Y. Eldar and T. Michaeli, Beyond Bandlimited Sampling, IEEE Signal Processing Magazine 48: 48 68 (2009). 5. G. van Kempen et al, Comparing Maximum Likelihood Estimation and Constrained Tikhonov-Miller Restoration as Applied to Confocal Microscopy, IEEEE Engineering in Medicine and Biology Jan/Feb: 76 83 (1996). 6. Z. Zalevsky, Spatial Information Transmission Using Orthogonal Mutual Coherence Coding, Optics Letters Vol. 30, No. 21: 2837 39 (2005). Authors Erik Novak, Bruker Nano Surfaces Division, Stylus and Optical Metrology (erik. novak@bruker-nano.com) Florin Munteanu, Bruker Nano Surfaces Division, Stylus and Optical Metrology (florin.munteanu@bruker-nano.com) Bruker Nano Surfaces Division is continually improving its products and reserves the right to change specifications without notice. 2011 Bruker Corporation. All rights reserved. AcuityXR, ContourGT, and Vision are trademarks of Bruker Corporation. AN548, Rev. A1 Bruker Nano Surfaces Division Tucson, AZ USA +1.520.741.1044 ext. 3/800.366.9956 ext. 3 productinfo@bruker-nano.com 6 www.bruker.com