Control strategy for seamless transition from islanded to interconnected operation mode of microgrids

Similar documents
Fuel cell power system connection. Dynamics and Control of Distributed Power Systems. DC storage. DC/DC boost converter (1)

Impacts of P-f & Q-V Droop Control on MicroGrids Transient Stability

Islanding Detection and Frequency Circuit Measurement by Power Distribution Relation Depending on the Angle

State of Charge (SOC)-Based Active Power Sharing Method for Distributed Generations in an Islanded Microgrid

CHIL and PHIL Simulation for Active Distribution Networks

Active Power Sharing and Frequency Control of Multiple Distributed Generators in A Microgrid

Voltage Support and Reactive Power Control in Micro-grid using DG

A Control Method of Parallel Inverter for Smart Islanding of a Microgrid

Microgrid Connection Management based on an Intelligent Connection Agent

WILEY CONTROL OF POWER INVERTERS IN RENEWABLE ENERGY AND SMART GRID INTEGRATION. Qing-Chang Zhong. Tomas Hornik IEEE PRESS

Anti-IslandingStrategyforaPVPowerPlant

Control of Power Converters for Distributed Generation

Parallel Operation of Distributed Generators by Virtual Synchronous Generator Control in Microgrids

Optimal sizing of battery energy storage system in microgrid system considering load shedding scheme

Transition from Grid Connected Mode to Islanded Mode in VSI fed Microgrids

Investigation and Correction of Phase Shift Delays in Power Hardware in Loop Real-Time Digital Simulation Testing of Power Electronic Converters

Hybrid Anti-Islanding Algorithm for Utility Interconnection of Distributed Generation

Synchronization and Smooth Connection of Solar Photovoltaic Generation to Utility Grid

Published in: Proceedings of the 3rd IEEE Energy Conversion Congress and Exposition (ECCE 2011)

Enhancement of Fault Current and Overvoltage by Active Type superconducting fault current limiter (SFCL) in Renewable Distributed Generation (DG)

Interactive Distributed Generation Interface for Flexible Micro-Grid Operation in Smart Distribution Systems

MICROGRIDS Large Scale Integration of Microgeneration to Low Voltage Grids

DSP-Based Simple Technique for Synchronization of 3 phase Alternators with Active and Reactive Power Load Sharing

An Accurate Power Sharing Method for Control of a Multi-DG Microgrid

EMERGING distributed generation technologies make it

STUDY OF CIRCULATING CURRENT PHENOMENA IN MULTIPLE PARALLEL INVERTERS OPERATING IN MICROGRID

UPQC with Islanding and Grid Connection for Microgrid Applications

Current Control Strategy for Parallel Operation of Inverters Based On Micro grids M.Bavithra 1, Belwin J. Brearley 2

ENHANCEMENT OF POWER FLOW USING SSSC CONTROLLER

A New Control Strategy for Three- Phase Inverter Applied To Induction Motor of Micro Grid

An Optimized Synchronous Techniques of Single Phase Enhanced Phase Locked Loop (EPLL)

E N G I N E E R I N G M A N U A L

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

Modeling and simulation of a single phase photovoltaic inverter and investigation of switching strategies for harmonic minimization

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

Manjeet Baniwal 1, U.Venkata Reddy 2, Gaurav Kumar Jha 3

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

A New Subsynchronous Oscillation (SSO) Relay for Renewable Generation and Series Compensated Transmission Systems

Delhi Technological University (formerly DCE) Delhi-42, India

UTILITY interactive inverters converting dc power sources

Frequency Control Method of Isolated Micro-grid Based on Thermostatically Controlled Load Qingzhu Wan1, a, Yuan Bian1, b and Yalan Chen1, c

SUPERCONDUCTING MAGNETIC ENERGY

A Control Topology to Enhance Performance of Weak Grid under Different Power Levels

2012 Grid of the Future Symposium. Impacts of the Decentralized Photovoltaic Energy Resources on the Grid

GRID CODE COMPATIBLE PROTECTION SCHEME FOR SMART GRIDS

Modeling of PV Interconnected Distribution System using Simulink

Published in: Proceedings of the 39th Annual Conference of IEEE Industrial Electronics Society, IECON 2013

Improving Passive Filter Compensation Performance With Active Techniques

Design of a Dual Active Bridge DC-DC Converter for Photovoltaic System Application. M.T. Tsai, C.L. Chu, Y.Z. Yang and D. R Wu

TRANSFORMER LESS H6-BRIDGE CASCADED STATCOM WITH STAR CONFIGURATION FOR REAL AND REACTIVE POWER COMPENSATION

Power Quality enhancement of a distribution line with DSTATCOM

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Voltage Control with Distributed Generators to Enhance Voltage Stability

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

Improved Real/Reactive Power Management and Controls for Converter-Based DERs in Microgrids

Phase-phase/phase-neutral: 24/13.8 kv star, 13.8 kv delta, 12/6.9 kv star.

University of Kurdistan. Adaptive virtual impedance scheme for selective compensation of voltage unbalance and harmonics in microgrids

An Adaptive V-I Droop Scheme for Improvement of Stability and Load Sharing In Inverter-Based Islanded Micro grids

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

ELEMENTS OF FACTS CONTROLLERS

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Control of Microgrid for Different Modes of Operation

Active Rectifier in Microgrid

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

Control Hardware-in-the-Loop Demonstration of a Building-Scale DC Microgrid Utilizing Distributed Control Algorithm

HARMONIC contamination, due to the increment of nonlinear

Harnessing of wind power in the present era system

Seshankar.N.B, Nelson Babu.P, Ganesan.U. Department of Electrical & Electronics Engineering, Valliammai Engineering College, Kattankulathur, Chennai

ISSN: [Reddyrani* et al., 6(4): April, 2017] Impact Factor: 4.116

Differential Protection for Microgrids with Embedded Generations

Babak Enayati National Grid Thursday, April 17

IEEE sion/1547revision_index.html

A Novel Islanding Detection Technique for Distributed Generation (DG) Units in Power System

Control and Optimization of Smart AC/DC Hybrid Microgrids

Renewable Interconnection Standard & Experimental Tests. Yahia Baghzouz UNLV Las Vegas, NV, USA

A New Control Method for the Power Interface in Power Hardware-in-the-Loop Simulation to Compensate for the Time Delay.

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP(

Accurate Synchrophasor Estimation to Support the Islanding Maneuver of Active Distribution Networks

Agent Based Distributed Control of Islanded Microgrid Real-Time Cyber-Physical Implementation

An Isolated DC-AC Converter Module Integrating Renewable Energy Source and Energy Storage for Cascaded Inverter

Cost Based Dynamic Load Dispatch for an Autonomous Parallel Converter Hybrid AC-DC Microgrid

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

LOW ORDER HARMONICS IMPROVEMENT OF A SINGLE GRID CONNECTED INVERTER SYSTEM UNDER PR CONTROL TECHNIQUE

Design Requirements for a Dynamic Voltage Restorer for Voltage Sags Mitigation in Low Voltage Distribution System

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

A Static Synchronous Compensator for Reactive Power Compensation under Distorted Mains Voltage Conditions

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

Mitigation of the Statcom with Energy Storage for Power Quality Improvement

A PV Based Thirteen Level Inverter For Microgrid Mr.K.sairam, M. Saritha Reddy, K.S. Mann, M. Narendra Kumar

Decentralized Synchronization of AC-Stacked Voltage Source Converters

Electric Power Systems Research

Open Access Research on Fast Response Characteristic of Magnetic Control Reactor

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

Transcription:

J. Mod. Power Syst. Clean Energy (217) 5(2):169 176 DOI 1.17/s4565-16-229- Control strategy for seamless transition from islanded to interconnected operation mode of microgrids C. N. PAPADIMITRIOU 1, V. A. KLEFTAKIS 1, N. D. HATZIARGYRIOU 1 Abstract s can operate either interconnected to the utility grid or disconnected forming an island. The transition between these modes can cause transient overcurrents or power oscillations jeopardizing the equipment safety or the system stability. This paper proposes a local multi agent control method for a seamless transfer between the islanded and interconnected modes of operation with agents implemented into the microgrid central switch (MCS) and into the microsources inverters. The MCS agent supervises the grid status and controls the switch for the transition of the microgrid through the different operation modes, while it communicates locally with the inverter agents of the microsources. The inverter agents undertake the synchronization process in case of reconnecting and change the inverter control mode depending on the grid status. Simulation and experimental results are presented to show the performance and feasibility of the proposed strategy. Keywords, Islanding, Reconnection, Agents, Synchronization, Control hardware-in-the-loop (CHIL) CrossCheck date: 3 July 216 Received: 14 June 215 / Accepted: 3 July 216 / Published online: 27 August 216 The Author(s) 216. This article is published with open access at Springerlink.com & C. N. PAPADIMITRIOU chpapadi@mail.ntua.gr V. A. KLEFTAKIS Vkleft@mail.ntua.gr N. D. HATZIARGYRIOU nh@power.ece.ntua.gr 1 Department of Electrical and Computer Engineering, National Technical University of Athens (NTUA), Athens, Greece 1 Introduction s consist of distributed generators (DG), storage devices, controllable loads and protection units, and they usually operate in low or medium voltage networks. s can operate interconnected to the power grid, or islanded, offering considerable control capabilities over the network operation [1, 2]. The transition between two modes may give rise to harmful transient overcurrents. In general, a smooth connection is achieved when the voltages of the systems to be connected coincide in magnitude, phase and the frequency. In microgrid applications, synchronization before reconnection is usually accomplished by detecting the voltage magnitude, phase and frequency difference between the main grid and the microgrid [3, 4]. This problem has been tackled in various papers in the past. In all these works, the importance of implementing a fast and accurate grid voltage synchronization algorithm has been highlighted. Reference [3] presents a control method based on the adaptation of a dual second order generalized integrator based on a frequency locked loop (DSOGI-FLL). The algorithm is implemented in a gridconnected power converter that acts as an intelligent connection agent (ICA). The presence of many voltage source converters, however, may deteriorate its effectiveness. Reference [4] proposes an active synchronizing control scheme that also adopts a central based coordinated control for multiple DGs. In [5], the synchronization control system sends remote compensator signals from the substation to the speed and voltage regulators of a hydro plant, achieving safe reconnection. The phase coincidence is addressed only by means of a synchronism check relay that blocks the reconnection until the phase difference is null. This may delay the transfer for undefined period of time.

17 C. N. PAPADIMITRIOU et al. Reference [6] presents a transfer strategy based on droop control of local microsources providing good results. The algorithm moves the droop equations of the microsources to achieve frequency synchronization and in later stage phase synchronization. However, the second synchronization stage affects the frequency synchronization, while the voltage magnitude coincidence is not addressed. The synchronization system presented in [7] is based on two dual second order generalized integrators (DSOGI) and two stationary reference frames phase locked loop (SRF-PLL) for synchronizing the grid voltage with the capacitor voltage of the converter filter. Besides the requirement of rather complex components, the main consideration here is that during the synchronization process, the droop control is not employed and none of its functions are carried out. Reference [8] presents the autonomous control for smooth transitioning between the two modes. The DGs operate as current controlled sources using proportional resonant (PR) regulators for frequency and phase angle regulation while a predictive voltage controller in each DG ensures voltage control across the microgrid. Reference [9] investigates the transient oscillation during the transition between modes and presents a modified PQ control method for their amelioration. Accordingly, the output of the PQ controller of the DGs synchronously tracks the output of a V/f controller of the DG voltage forming unit to pass from islanded to grid-connected mode. In both approaches [8, 9], constant communication between the islanded and the main grid is needed. In [1], transitioning is based on two separate synchronization compensators that immediately affect real and reactive power control loops. Inputs to these synchronization compensators are the magnitude and phase of the two voltage phasors of the microgrid and the main grid. The immediate effect on the droop loops may lead to instability, in case of large differences in angle and magnitude between the two systems. The technique of [11] follows the same reasoning by implementing the synchronization algorithm in the secondary control level that affects the set points of the droop control loops. Reference [12] describes the transition process of a real microgrid between modes. The voltage source unit gradually lowers the microgrid frequency, in order to reduce the phase difference. When the breaker closes, a frequency spike is observed. In this paper, a control strategy based on local agents that are responsible for the seamless reconnection of the microgrid to the upstream grid is presented. The proposed scheme has the flexibility and reliability of distributed controller schemes. The agent of the microgrid central switch (MCS) manages the status of the switch, while exchanging information with the inverter agents of the microsources when needed. The inverter agents are responsible for the synchronization process and also manage the control strategy of the inverters depending on the microgrid operation state. In case of failure of an inverter delivering a signal to the MCS agent, synchronization is not jeopardized; it can only be slowed down. The synchronization process is based on employing two phase locked loops (PLLs) and three simple proportionalintegral (PI) controllers, whose output are three compensator signals. These signals implement voltage, frequency and phase synchronization by adjusting the control signals of the pulse width modulation (PWM) of the microsource inverters. The proposed strategy is simple to implement, as it is based on the simple PI control without affecting the droop control of the inverters. After the synchronization criteria are met, the MCS closes at a zero-crossing of the voltage waveform, and at the same time, all the agents are informed for the new operating status to switch to the appropriate control strategy. All synchronization criteria are accurately met in a fast and efficient way, as shown by the numerical and laboratory simulations. 2 Agents control strategy 2.1 MCS agent The MCS ties the point of connection between the microgrid and the upstream distribution system. The interconnection switches are designed to meet grid interconnection standards (IEEE 1547 and UL 1741 for North America) to minimize custom engineering and site-specific approval processes and lower cost [13]. The MCS switching conditions are the following. 1) disconnection from the mains The islanding operation mode can be intentional, e.g. scheduled maintenance, or unintentional, e.g. failure in the upstream network. In both cases, the microgrid switching to islanding operation ensures continuation of supply to critical loads. 2) reconnection to the mains Once islanded, the microgrid can be reconnected to the utility grid. Synchronization of the two grids is necessary before closing the central switch at a voltage zero crossing. Frequency, voltage magnitude and voltage phase need to be accurately matched to prevent transients. The following sections focus on the microgrid reconnection to the upstream network. The main modules of the MCS agent are shown in Fig. 1. The term agent is used here to describe the software that functions autonomously and continuously, while it has the ability to communicate with other agents. The operation mode detection module is enabled by an external signal that is driven by the microgrid central controller (MGCC), in case of intended islanding/

Control strategy for seamless transition from islanded to interconnected operation mode 171 MGCC Islanding detection methods Operation mode Detection module Decision module Events record module Transfer module MCS agent Control signal MCS Classic droops Synch signals (t) Synch process PLLs Modified signals d(f(t)) dt PWM Fig. 1 MCS agent structure Inverter agents 1 or to start or stop the synch process Inverter agent When d(f(t))/dt=, synch criteria met reconnection or an islanding detection method (IDM) in case of unintended islanding and is beyond the scope of this paper. The decision module provides transfer signals to the transfer module according to the signals exchanged with the islanding detection module and the microsource inverter agents. The transfer module initiates, if necessary, the transfer process by sending the appropriate signal to the MCS. It also sends the inverters of the microsources appropriate signals in order to change their control mode. Note that in case of reconnection, where the synchronization process should be enabled, the decision module exchanges also signals with the inverter agents. This process is described in the next section. The events record module records the real time data during the transfer process and sends these data for further analysis. After the transfer is complete, a signal will be sent to the decision module, and the agent will prepare itself for the next transfer. 2.2 Microsource inverter agents This section describes the synchronization process that the inverter agents undertake when a transition from islanded to interconnected mode is required. Each inverter agent structure is shown in Fig. 2. Two PLLs for detecting phase and frequency of the main network and the microgrid at the point of common coupling (PCC) are employed. The proposed method is integrated into the inverter agents that undertake the synch process, when the appropriate signal from MCS agent is received. It should be noted that the frequency and voltage of a microgrid are determined by multiple generators and loads, so the following process is integrated in all microsource inverters. The proposed process is based on local measurements and consists of two steps. Firstly, the synchronization between frequency and voltage magnitude is achieved and secondly the phase synchronization is accomplished Decision module MCS agent Fig. 2 Synchronization process that inverter agent undertakes without affecting the first step. Then reclosing is allowed. More details are as follows. When the microgrid operates in islanded mode, the inverters operate under the following conventional droop equations. f ¼ f ref þ k p ðp ref PÞ ð1þ V ¼ V ref þ k q ðq ref QÞ where f ref, V ref, P ref, Q ref are the reference values of frequency, voltage magnitude, active power and reactive power; f, V, P, Q are the measured values of the corresponding electrical parameters; k p, k q are the droop coefficients. It has to be noted that the reference values of the active and reactive powers are setpoints dictated by the control strategy of each DG or the MGCC. When the MCS agent decides reclosing, its decision module sends a signal (1) to the inverter agents so that the first step of synchronization starts. The difference between the microgrid and the grid frequency drives a simple PI controller. The output of the controller is the compensator signal S f that modifies the classical voltage reference of the PWM, as shown in Fig. 3. Similarly, the voltage difference drives a simple PI controller whose output modifies the same PWM sinusoidal signal (Fig. 3). When both the compensator signals reach a steady value and their derivative is zero, the second step of the synchronization process is triggered. The difference between the microgrid phase and the main grid phase drives a simple PI controller. Its output is the compensator signal S p that changes the phase of the sinusoidal signal of the PWM, as shown in Fig. 3 without affecting the frequency of the microgrid that has been regulated in the previous step. When the compensator signal S p gets a constant value, the phase synchronization is

172 C. N. PAPADIMITRIOU et al. f grid f meas PI S f PLL PLL Active power calculation Reactive power calculation θ grid V grid V Mgrid f V P Q f Droop equations (ES v )cos(2π(fs f )S p ) E PI S v PWM Pulses θ Mgrid PI S p Modified control signals during synch process Fig. 3 Modified control signals during synchronization completed. Note that the compensator signals are the same for all agents without immediately affecting the droops and thus the power sharing among the microsources. Next, an appropriate signal is sent to the MCS agent to inform that the synchronization criteria is met. The decision module of the MCS agent sends simultaneously the appropriate signal () to stop the synchronization process and a transfer signal to the transfer module. When reconnection is achieved, the transfer module informs the inverter agents about the new operation status in order to change from voltage control mode to current control mode. The above procedure is shown in Fig. 4. The opposite procedure can be followed in case of intentional transfer from interconnected to islanded mode. In this case, the P&Q setpoints of Fig. 4 should be first modified, so that there is no power exchange between the grid and the microgrid by means of generation rescheduling or load shedding. Then the transfer process can be activated and the inverter agents can switch control mode. 3 Simulation results In order to evaluate the proposed scheme, the microgrid of Fig. 5 is used. Two DG interfaces are connected with an AC feeder through their inverters. An RL load and an induction motor are also connected at the same feeder. The MCS is responsible for the operational status of the microgrid. The PI controller gains have been specified by trial and error after extensive iterations in order to ensure the convergence of the controlled variables to the desired values. The system parameters are as follows: DG nominal power is 3 kw; X and R of distribution lines are.268 X/ km and.5652 X/km, respectively; voltage amplitude and frequency of the AC system are 38 V and 5 Hz; power and capacity of the PL load are 3 kw and 13 kva; power, voltage amplitude and rotate speed of the induction motor are 4 kw, 4 V and 145 r/min. AC feeder Time Islanding operation Droop control under fault condition Fault elimination/ normal condition Synch process Modified droop control Voltage, frequency & phase synch Interconnected operation P & Q set points Normal grid operation DG DG VSI VSI Line Line Line MCS RL load Induction motor MCS agent starting the synch process Inverter agents synch criteria met MCS agent connecting order Breaker Utility grid Fig. 4 Transfer process between two operation modes Fig. 5 structure

Control strategy for seamless transition from islanded to interconnected operation mode 173 At initial steady state, the microgrid operates in islanded mode. The synchronization process begins at 2 s and is completed at 3.5 s. When the criteria are met, the MCS closes at 3.55 s, when the first zero crossing occurs. Some representative results are presented. During the islanded operation, the inverter agents operate under droop control mode. Thus, the frequency and voltage of the microgrid may differ slightly from their nominal values. As shown in Fig. 6, the frequency lies at 49.93 Hz during the islanded mode. At 2 s, the inverter agents start the voltage and frequency synchronization after receiving the appropriate signal from the MCS agent. The frequency is restored within 1 s. In Fig. 7, the compensator S f signal is shown. When the compensator signal gets a constant value at 3 s, the frequency is restored as expected. In Fig. 8, the root mean square (RMS) value of the voltage is shown. The voltage during the whole synchronization process and the reconnection at 3.51 s does not experience any oscillations or transients and the compensator signal S v remains zero. The zero derivatives of the compensator signals trigger the second step of phase synchronization without affecting the signals of the first step. The phase difference between the two voltages of the microgrid and the grid is shown in Fig. 9. At 2 s, the phase Frequency (Hz) 5.5 5. 49.95 49.9 1.5 2. 2.5 3. 3.5 4. Fig. 6 frequency Compensator signal.7.6.5.4.3.2.1 1.5 Fig. 7 Compensator signal S f Voltage 1.2 1..98 1.5 Fig. 8 Voltage at PCC 2. 2.5 3. 3.5 2. 2.5 3. 3.5 4. 4. difference is around 9 degrees. At 3 s, the phase synch is triggered and the phase difference is eliminated at 3.5 s, as shown in Fig. 1. At 3.5 s, the phase synchronization is achieved and the compensator signal S p triggers (Fig. 11) Phase (rad) Phase (rad) Voltage 1 5 1 5 1-1 2. 2.1 2.2 2.3 Fig. 9 Phase difference before phase synchronization Phase (rad) Phase (rad) Voltage 1 5 8 6 4 2 1-1 3.47 Mircogrid 3.48 3.49 3.5 Mircogrid Fig. 1 Phase difference after phase synchronization Compensator signal 1-1 -3-5 -7-9 1.5 Fig. 11 Compensator signal S p 2. 2.5 3. 3.5 4.

174 C. N. PAPADIMITRIOU et al. Active power (kw) Reactive power (kvar) 35 3 25 2 15 1.5 Active power Reactive power 2. 2.5 3. 3.5 Fig. 12 Absorbed active and reactive powers from loads 4. Voltage (V) 235 23 225 22 215 21 Main grid 25 1 2 3 4 5 6 Fig. 14 Voltage difference during synchronization-proposed method the decision module of the MCS. At 3.51 s, the microgrid reconnects with the mains seamlessly. As expected, the loads do not experience any oscillations during both the synchronization and reconnection process (Fig. 12). 4 Hardware setup and results In this section, the proposed control scheme is evaluated experimentally through control hardware in the loop (CHIL) simulation. In a CHIL experiment, the hardware under test is a controller, in which the proposed control algorithm is studied while the network is still simulated. The real-time digital simulator (RTDS ) of the National Technical University of Athens (NTUA) laboratory is employed for implementing the control, while the same network topology of Fig. 5 is tested. It is clear that the use of an actual controller and the inherent time delays in the communication may impact the resulting waveforms, however the qualitative comparison between simulation and lab experiment is very satisfactory. Figures 13 and 14 show the frequency and voltage of the microgrid and the main grid, respectively, during the synchronization process. At 1 s, the first step of the synchronization process begins. The frequency of the islanded microgrid is restored from 49.5 Hz to 5 Hz within 2.2 s, when the signal S f reaches a steady value. The voltage of the islanded microgrid is restored from 214 V to 23 V within 1 s, when the signal S v gets a steady value. Frequency (Hz) 5.2 5. 49.8 49.6 Main grid 49.4 1 2 3 4 5 6 Fig. 13 Frequencies during transition-proposed method At 3.2 s, the first step of synch is achieved and the regulation of the phase begins. Figure 15 presents the phase difference during the synchronization mode. At 5 s, the angle difference between the two systems is almost zero and the main breaker closes resulting in a seamless transition from islanded to grid-connected mode. Note that the frequency remains at the desired value even during the phase synchronization from 3 s to 5 s. This is one of the main differences between the proposed synchronization method and the one described in [12]. Reference [12] deals with the transition of a laboratory microgrid from islanded to grid-connected mode. For purposes of qualitative comparison with the previous results, the transition process of [12] is repeated in the next figures. The voltage source unit (this is a battery inverter in the laboratory) monitors the grid voltage waveform and gradually lowers the microgrid frequency at 1 s, in order to reduce the phase difference. It is obvious that the phase synchronization affects the frequency. When the phase difference is minimized, the breaker closes at 45 s resulting in a frequency jump (Figs. 16 and 17). Angle ( ) 1 8 6 4 2 1 2 3 4 5 6 Fig. 15 Phase difference during synchronization Frequency (Hz) 5.2 5. 49.8 49.6 Island 5 1 15 2 25 3 35 4 45 5 Fig. 16 Frequencies during transition according to [12]

Control strategy for seamless transition from islanded to interconnected operation mode 175 Voltage (V) 3 2 Island 1 5 1 15 2 25 3 35 4 45 5 Fig. 17 Voltage difference during synchronization in [12] In [13], frequency and angle synchronization affect each other and during the breaker s closure, frequency or angle slightly deviates from their desired values. As a result, oscillations or non-desired spikes may happen. 5 Conclusion In this paper, a seamless transfer control strategy based on local agents is presented. The microgrid can switch from islanded to interconnected mode of operation fast without frequency and voltage oscillations. The agent system consists of the MCS agent and the inverter agents. The MCS agent supervises the operation mode of the microgrid and manages the operation of the switch. The inverter agents are responsible for their operation mode and the synchronization process during the reconnection. The agents exchange information so that the reconnection is seamless. The synchronization control achieves firstly voltage and frequency and then phase synchronization. The compensator signals modify the classical PWM reference signal of the inverters, so that the phase and magnitude difference between both microgrid and grid voltages is minimized by means of three simple PI controllers. The proposed control strategy is tested through simulation and a hardware setup proving satisfying performance. Open Access This article is distributed under the terms of the Creative Commons Attribution 4. International License (http:// creativecommons.org/licenses/by/4./), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. References [1] Dimeas AL, Hatziargyriou ND (25) Operation of a multiagent system for microgrid control. IEEE Trans Power Syst 2(3):1447 1455 [2] Katiraei F, Iravani R, Hatziargyriou N et al (28) s management. IEEE Power Energy Mag 6(3):54 65 [3] Rocabert J, Azevedo GMS, Luna A et al (211) Intelligent connection agent for three-phase grid-connected microgrids. IEEE Trans Power Electron 26(1):2993 35 [4] Cho C, Jeon JH, Kim JY et al (211) Active synchronizing control of a microgrid. IEEE Trans Power Electron 26(12):377 3719 [5] Assis TML, Taranto GN (212) Automatic reconnection from intentional islanding based on remote sensing of voltage and frequency signals. IEEE Trans Smart 3(4):1877 1884 [6] Jin C, Gao MZ, Lü XF et al (212) A seamless transfer strategy of islanded and grid-connected mode switching for microgrid based on droop control. In: Proceedings of the 212 IEEE energy conversion congress and exposition (ECCE 12), Raleigh, NC, USA, 15 2 Sept 212, pp 969 973 [7] Rizo M, Huerta F, Bueno E et al (212) A synchronization technique for microgrid reclosing after islanding operation. In: Proceedings of the 38th annual conference on IEEE Industrial Electronics Society (IECON 12), Montreal, Canada, 25 28 Oct 212, pp 5596 561 [8] Shoeiby B, Davoodnezhad R, Holmes DG, et al (214) A resonant current regulator based microgrid control strategy with smooth transition between islanded and grid-connected modes. In: Proceedings of the IEEE 5th international symposium on power electronics for distributed generation systems (PEDG 14), Galway, Ireland, 24 27 Jun 214, 8 pp [9] Zhang TF, Yue D, O Grady MJ et al (215) Transient oscillations analysis and modified control strategy for seamless mode transfer in micro-grids: A wind-pv-es hybrid system case study. Energies 8(12):13758 13777 [1] Chen ZW, Zhang W, Cai JQ, et al (215) A synchronization control method for micro-grid with droop control. In: Proceedings of the 215 IEEE energy conversion congress and exposition (ECCE 15), Montreal, Canada, 2 24 Sept 215, pp 519 524 [11] Micallef A, Apap M, Spiteri-Staines C et al (215) Single-phase microgrid with seamless transition capabilities between modes of operation. IEEE Trans Smart 6(6):2736 2745 [12] Messinis G, Kleftakis V, Kouveliotis-Lysikatos I, et al, (214) A multi-microgrid laboratory infrastructure for smart grid applications. In: Proceedings of the 9th mediterranean conference on power generation, transmission distribution and energy conversion (MedPower 14), Athens, Greece, 2 5 Nov 214, 7 pp [13] Kroposki B, Lasseter R, Ise T et al (28) Making microgrids work. IEEE Power Energy Mag 6(3):4 53 C. N. PAPADIMITRIOU received the diploma degree in Electrical and Computer Engineering from the University of Patras, Greece (21 26) as well her Ph.D degree (27 212). She is currently a researcher at Electrical and Computers Engineering Department of NTUA. Her main research interests include renewable energy sources, fuel cells, storage devices, distributed generation and microgrids, power quality, computer applications in power system analysis, control software development and artificial intelligence on power systems. She is a member of the Technical Chamber of Greece. V. A. KLEFTAKIS received the diploma in electrical engineering from the School of Electrical and Computer Engineering, National Technical University of Athens (NTUA), in 211. He works as a researcher in the Electric Energy Systems Laboratory and his research interests include real-time and hardware-in-the-loop simulation, distributed generation, and microgrids. He is a member of the Technical Chamber of Greece since 213. N. D. HATZIARGYRIOU received the diploma degree in electrical and mechanical engineering from the National Technical University of Athens (NTUA), in 1976, and the M.Sc. and Ph.D degrees from the University of Manchester Institute of Science and Technology, Manchester, U.K., in 1979 and 1982, respectively. He is the chairman and CEO of the Hellenic Distribution Network Operator. Since 1984, he is with the Power Division of the Electrical and Computer

176 C. N. PAPADIMITRIOU et al. Engineering Department of the National Technical University of Athens, and since 1995, he is a full professor in power systems. From February 27 to September 212, he was the deputy CEO of the Public Power Corporation (PPC) of Greece, responsible for Transmission and Distribution Networks, Island DNO and the Center of Testing, Research and Prototyping. He is fellow member of IEEE, past chair of the IEEE Power System Dynamic Performance Committee, Distinguished member of CIGRE and past chair of CIGRE SC C6 Distribution Systems and Distributed Generation. He is chair of the Advisory Council of the EU Technology Platform on Smarts. He is the member of the Energy Committee of the Athens Academy of Science. He is the author of the book s: Architectures and Control and of more than 2 journal publications and 5 conference proceedings papers.