BC145 SIGNAL ISOLATOR BOARD

Similar documents
INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

MODEL KBWD-15 Pulse Width Modulated (PWM)

Copyright 2014 by Minarik Drives

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

USER S MANUAL PROCESS CONTROL MODULE PCM3

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

SPECIFICATION, CONTROLS AND ACCESSORIES

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

TRANSDUCER IN-LINE AMPLIFIER

INSTALLATION AND OPERATION MANUAL MODEL KBPW-240D. KB Part No (Black Case) Part No (White Case) NEMA 4X, IP-65

Precision Frequency To Voltage Converter Card

201AP Charge Amplifier User Manual

AD-8100 & AD-8200 Servo Amplifiers

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

TABLE OF CONTENTS WARRANTY

Programmable K-Factor Scaler B and Programming Software Kit B

INSTRUCTION MANUAL UTL260

Model 9305 Fast Preamplifier Operating and Service Manual

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

K-FACTOR SCALER B & B

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

DC200A Displacement Clipper User Manual

200Amp AC Clamp Meter + NCV Model MA250

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

Current Loop Interface Module M 2025D

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Model 863 Quad Timing Filter Amplifier Operating and Service Manual

Independent Technology Service Inc Independence Ave. Chatsworth, California Toll Free:

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

High Frequency SineWave Guardian TM Filter

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Grid Radar Installation Manual

High Frequency Sinewave Guardian TM Filter

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

SPECIFICATION, CONTROLS AND ACCESSORIES

Model 113 Scintillation Preamplifier Operating and Service Manual

Model 9302 Amplifier-Discriminator Operating and Service Manual

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

200B Clipper Module User Manual

INSTRUCTION MANUAL. March 11, 2003, Revision 3

41P Portable Calibrator User Manual

Dawson DDM190. Digital Multimeter User s Manual

TRANSDUCER IN-LINE AMPLIFIER

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Model 7000 Low Noise Differential Preamplifier

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

MLA High Performance Microstepping Driver. User s Guide E. Landon Drive Anaheim, CA

Instruction Manual. Description Calibration. Excitation Sensor and Reverse Power Relay

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

Series 3000 Model R-107A

MBC Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

Contents NUDRIVE ACCESSORY USER GUIDE

PCO-7114 Laser Diode Driver Module Operation Manual

Model 1791 VHF Radio User's Manual

AMP-13 OPERATOR S MANUAL

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

INSTRUCTION MANUAL LKG

ELECTROSURGICAL UNIT ANALYZER

UM Series DC Servo Control

Pen Multimeter. Model

S11 Adjustable Speed Drive Engineering Specification

MODEL AT-10 ANALOG TRANSMITTER

Digital Lighting Systems, Inc.

VF-nC1 Adjustable Speed Drive Engineering Specification

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

Pen Multimeter. Model

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

OPERATION MANUAL. Spring Return Actuator. Electrical Actuator. September, st

COOPER POWER SERIES. External application of a motor start capacitor on a single-phase voltage regulator. Voltage Regulators MN225063EN

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

600A Clamp Meters w/tightsight Display

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control

DDM350 Pen-Type Digital Multimeter User s Manual

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

UM Series DC Servo Control

7I25 H-BRIDGE MANUAL

VS1SM Single Phase AC Drive

Current Loop Interface Module M-2025C

2006 MFJ ENTERPRISES, INC.

RHS SERIES RH Set Point Controller/Probe

Dynamo Brushless DC Motor and GreenDriveTM Manual

Accuracy 1.2 PERCENT AC VOLTAGE, 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT DC CURRENT, 1 PERCENT RESISTANCE, 2.5 PERCENT TEMPERATURE Battery Type

Model 533 Dual Sum and Invert Amplifier Operating and Service Manual

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

Variable Speed Brushed DC Motor Drive

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Transcription:

BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373

Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download the latest version of this manual in Adobe Acrobat PDF format.

Table of Contents Chapter 1 Introduction Safety Warning...1-1 General Performance Specifications...1-4 Chapter 2 Installation Mounting Instructions.... 2-1 Chapter 3 Wiring AC Power...3-1 Input Terminals...3-2 Current Signal Input...3-2 Voltage Signal Input...3-4 Chapter 4 Adjustments Output Signal...4-1 MN1373 i

Chapter 1 Introduction Introduction The BC145 Signal Isolator is used to isolate, amplify and condition DC voltage and current signals from any source (motors, tachs and transducers) which will provide most adjustable speed motor controls with a voltage following input. The maximum output voltage of the isolator is 10 volts which is a linear function of the input signal. The BC145 is versatile since it can accommodate a wide range of input voltages (0-25*, 0-120 and 0-550VDC) and, in addition, a wide range of input current signals (4-20mA, 10-50mA and 1-5mA). The Voltage/Current ( VLT/CUR ) jumper is used to change the BC145 from a voltage to current input. BC145 is a unipolar input, providing 0-10V input. For Regenerative Drives with bipolar ±10V input, other Signal Isolators are available. A built-in power supply enables the BC145 to be controlled with a 5KΩ remote potentiometer (connect potentiometer to terminals P1, 5 and 6 ). The potentiometer can also be wired for Auto/Manual Operation. *The input range of 0-25V is the maximum voltage that can be applied to terminals 5 and 6. The minimum input voltage is 0-5 volts which can achieve an output voltage of 0-10 volts. The unit is factory calibrated so that a 0-10VDC input yields a 0-10VDC output. SAFETY NOTICE A Warning statement indicates a potentially hazardous situation which, if not avoided, could result in injury or death. A Caution statement indicates a potentially hazardous situation which, if not avoided, could result in damage to property. A Note indicates additional information that is not critical to the installation or operation. WARNING: This equipment may contain voltages as high as 1000 volts! Electrical shock can cause serious or fatal injury. Only qualified personnel should attempt the start-up procedure or troubleshoot this equipment. WARNING: Be sure the system is properly grounded before applying power. Do not apply AC power before you ensure that all grounding instructions have been followed. Electrical shock can cause serious or fatal injury. 1-1 MN1373

SAFETY NOTICE Continued WARNING: Electrical shock can cause serious or fatal injury. Be sure that all power is disconnected and there is no voltage present from this equipment or equipment to which it is or will be connected. Electrical shock can cause serious or fatal injury. Only qualified personnel should attempt the installation and start-up procedures. WARNING: Electrical shock can cause serious or fatal injury. Verify there is no voltage phase-to-phase or phase-to-neutral at the motor leads before connecting motor to this control. Motor may have high voltage present even when disconnected from this control. WARNING: Do not use motor overload relays with an automatic reset feature. These are dangerous since the process may injure someone if a sudden or unexpected automatic restart occurs. If manual reset relays are not available, disable the automatic restart feature using external control wiring. WARNING: This unit has an automatic restart feature that will start the motor whenever input power is applied and a RUN (FWD or REV) command is issued. If an automatic restart of the motor could cause injury to personnel, the automatic restart feature should be disabled. WARNING: Using a jumper to eliminate the start/stop function will cause the motor to run at the Main Speed Potentiometer setting when the AC line is applied. WARNING: If possible, do not adjust trim pots with the main power applied. Electrical shock can cause serious or fatal injury. If adjustments are made with the main power applied, an insulated adjustment tool must be used to prevent shock hazard and safety glasses must be worn. WARNING: Do not use this drive in an explosive environment. An explosion can cause serious or fatal injury. This drive is not explosion proof. WARNING: When the Enable jumper is installed, the drive and motor will start and run when AC power is applied, when power is restored after a momentary power loss, or after an overload or TCL fault is reset. The user must ensure that automatic start up of the driven equipment will not cause injury to operating personnel or damage to the driven equipment. The user is responsible for providing suitable audible or visual alarms or other devices to indicate that the drive may start at any moment. Failure to observe this warning could result in severe bodily injury or loss of life. WARNING: Do not use start/stop, inhibit or enable functions as a safety disconnect. Use only an AC line disconnect for that purpose. Failure to observe this warning could result in severe bodily injury or loss of life. Caution: Disconnect motor leads (A1 and A2) from control before you perform a Dielectric Withstand test on the motor. Failure to disconnect motor from the control will result in extensive damage to the control. The control is tested at the factory for high voltage / leakage resistance as part of Underwriter Laboratory requirements. MN1373 1-2

SAFETY NOTICE Continued Caution: Do not connect AC power to the Motor terminals A1 and A2. Connecting AC power to these terminals may damage the control. Caution: Baldor recommends not to use Grounded Leg Delta transformer power leads that may create ground loops. Instead, we recommend using a four wire Wye. Caution: Suitable for use on a circuit capable of delivering not more than 5,000 RMS symmetrical short circuit amperes listed here at rated voltage. Caution: Adjusting the current limit above 150% of the motor nameplate rating can cause overheating and demagnetization of the PM motor. Caution: Do not leave the motor in a locked rotor condition for more than a few seconds since motor damage may occur. Caution: Shunt wound motors may be damaged if field windings remain energized for an extended period of time without armature rotation. Receiving Each control is thoroughly tested at the factory and carefully packaged for shipment. When you receive your control, there are several things you should do immediately. 1. Observe the condition of the shipping container and report any damage immediately to the commercial carrier that delivered your control. 2. Verify that the part number you received is the same as the part number listed on your purchase order. 3. Do not unpack until ready for use. 1-3 MN1373

Table 1-1 General Performance Specifications Description Specification AC Power Requirements 115 or 208-230VAC, 50/60Hz (1) Signal Input Voltage (2) 0-25, 0-120, 0-550VDC Signal Input Current (2) 1-5, 4-20, 10-50mA (3) Maximum Output Voltage 10 volts Maximum Output Current 10mA Range of MIN Trimpot ±3 volts Range of MAX Trimpot 0 to 2 times the input voltage with maximum of 10 volts Linearity (4) ±0.1% Temperature Drift (4) 4mV per C Temperature Operating Range 0-40 C / 32-104 F Operating Humidity Range (% Relative, Non-Condensing) 0-95 Storage Temperature -25 to +85 C / -13 to +185 F Note: (1) To achieve full specifications, input voltage must be within ±10% of nominal. (2) Floating (non-grounded) or grounded input signal may be used. (3) To convert from 4-20mA to 1-5mA, add a 1kΩ 1/4W resistor across terminals 5 and 6. To convert to 10-5-mA, add a 150Ω 1W resistor across terminals 5 and 6. See Figure 3-3. (4) Specifications are based on an output of 10 volts. MN1373 1-4

Chapter 2 Installation Mounting Instructions Mount the Signal Isolator using (4) 6-32 screws (not included). Use the Control Layout and Mechanical Specifications drawing to locate the mounting holes. The unit is designed to be mounted in any position providing its components do not come in contact with grounded or live wiring. 2-1 Control Layout & Mechanical Specifications (Inches/[mm]) (Illustrates Factory Setting of Jumper J1) 2-1 MN1373

Wiring WARNING: READ SAFETY WARNINGS BEFORE ATTEMPTING TO USE THIS CONTROL. Chapter 3 Installation Caution: To avoid erratic operation, do not bundle AC Line and motor wires with potentiometer, voltage following, enable, inhibit or other signal wiring. Use shielded cables on all signal wiring over 12 (30cm). The shield should be earth grounded on the control side only. AC Power The BC145 is powered with either 115 or 230VAC, 50/60 Hz by arranging the jumpers between terminals 1 to 4 properly. See Figures 3-1 and 3-2. Be sure unit is wired in accordance with the National Electrical Code and other codes that may apply. It is recommended that a 1 amp fuse be installed in series with the AC line. 3-1 115V Connection MN1373 3-1

3-2 230V Connection Input Terminals A voltage or current signal from a microprocessor, tachometer, transducer, etc. is to be connected to terminals 5 through 8. The selection of the proper terminal is based on the maximum level of the input signal. See Figure 3-3, Table 3-1 and Figure 3-4. Current Signal Input WARNING: READ SAFETY WARNINGS BEFORE ATTEMPTING TO USE THIS CONTROL. The Signal Isolator accepts 4-20mA DC input to provide 0-9VDC output. Connect the current signal input common (-) to Terminal 5 and the positive (+) to Terminal 6, as shown in Figure 3-3. Other current signal input ranges can also be used by installing appropriate resistors across terminals 5 and 6. Calibrate the Signal Isolator in accordance with the procedure described below. Note: Two resistors for 10-50mA and 1-5mA inputs are supplied in the hardware bag included with this kit. 3-2 MN1373

Figure 3-3 Current Signal Input Connection 4-20mA DC Signal Input: No resistor required. Set Jumper J1 in CUR position. 10-50mA DC Signal Input (Use Large Resistor with Color Code Brown-Green-Brown ): Install the 150Ω - 1W resistor across Terminals 5 and 6. Set Jumper J1 in CUR position. 1-5mA DC Signal Input (Use Small Resistor with Color Code Brown-Black-Red ): Install the 1kΩ - 1/4W resistor across Terminals 5 and 6. Set Jumper J1 in VOLT position. Procedure to Calibrate the Signal Isolator When Using Current Signal Input: 1. Connect a DC voltmeter (a digital voltmeter is suggested) to Terminals 9 (-) and 10 (+). 2. Apply the minimum signal input current to Terminals 5 (-) and 6 (+). 3. Adjust the MIN Trimpot on the Signal Isolator to obtain an output voltage of 0VDC. 4. Apply the maximum signal input current to Terminals 5 (-) and 6 (+). 5. Adjust the MAX Trimpot on the Signal Isolator to obtain an output voltage of 9VDC. MN1373 3-3

Voltage Signal Input WARNING: READ SAFETY WARNINGS BEFORE ATTEMPTING TO USE THIS CONTROL. Note: The Voltage/Current (VLT/CUR) jumper must be in the VLT position (factory setting). The BC145 is designed to accept a wide range of input voltage signals as follows: Input Terminals 3-1 Voltage Input Signal Minimum Input Voltage Range 5, 6 0-5 0-25 5, 7 0-25 0-120 5, 8 0-120 0-550 Maximum Input Voltage Range Connect input voltage signal to proper input terminals as indicated in Figure 3-4. 1. Connect a 10VDC meter (digital meter is suggested) to terminals 9 (-) and 10 (+). 2. Apply the maximum input voltage that would be supplied from tach, transducer, etc. 3. Adjust the MAX trimpot to the desired output voltage. Example: A follower motor is to follow the output of a leader motor with an armature voltage range of 0-90V. 3-4 MN1373

Figure 3-4 Voltage Input Signal Connections a. Connect the armature of the leader motor to the BC145 input terminals 5 (-) and 7 (+). b. Set the armature voltage of the leader motor to zero (0). Adjust the MIN trimpot so that the output at terminals 9 (-) and 10 (+) reads zero (0) volts. c. Reset the armature voltage of the leader motor to 90V. Adjust the MAX trimpot to the desired output voltage. Note: (1) When setting the output voltage using the MIN and MAX trimpots, the voltage or speed of the driven motor can be read directly instead of using the output of the BC145. (2) When readjusting the MIN and MAX trimpots, always set the minimum voltage first and then the maximum voltage. (3) Trimpots allow approximately 20 turns for the full range of adjustment. If during the adjustment procedure the output stops changing, try reversing the direction of rotation of trimpot. MN1373 3-5

Output Signal Chapter 4 Adjustments WARNING: THE CONTROLS ENABLE CIRCUIT IS INOPERATIVE WHEN USING THE BC145 SIGNAL ISOLATOR CONNECTED AS SHOWN IN THE FOLLOWING DIAGRAMS. The output signal from the BC145 is obtained from terminals 9 (-) and 10 (+). Connect the output directly to the signal following input terminal of the speed control. For multiple follower motors, several controls can be driven from a single BC145. Be sure the AC line connections to the follower control are to the same phase (e.g., L1 to L1 and L2 to L2 of all controls.) The output from the BC145 can be scaled to control the speed control over any desired speed range. Adjust the MIN trimpot to provide the desired minimum speed and the MAX trimpot to provide the desired maximum speed. Figure 4-1 Leader/Follower Voltage Following System with Multiple Motors 4-1 MN1373

Note: * The BC141 controls depicted above and in the following diagrams could also be other models in your application - BC142, BC142-5, BC142-6, or BC155. A 10K ratio potentiometer is used to control up to ten (10) follower motors. If a 5K ratio potentiometer is used, up to five (5) follower motors can be controlled. WARNING: IF SIGNAL ISOLATOR IS CONNECTED TO MULTIPLE SPEED CONTROLS: 1) Multiple controls must be powered from the same phase of AC line. 2) The positive input terminal to each speed control must be installed with a 1 amp - 600V isolation diode, as shown in Figure 4-1. 3) Multiple speed controls cannot be used with PWM, Regenerative or Adjustable Frequency Drives (Inverters). Figure 4-2 Leader/Follower Voltage Following System MN1373 4-2

Figure 4-3 Process Control with Auto/Manual Switch - Connection for Models BC141, BC142, BC142-5, BC142-6, and BC155 Note: The BC145 can be wired in an Auto/ Manual mode which will allow manual override of an automatic process. See Figure 4-3. Figure 4-4 Process Control with Auto/Manual Switch - Connection for Models BC154, BC154-SI, BC154-R, BCWD140, BC160, and BC354 4-3 MN1373

Figure 4-5 Process Control with Auto (Ratio Pot)/Manual Switch - Connection for Models BC141, BC142, BC142-5, BC142-6 and BC155 Note: The following circuit provides for dual purpose usage of the speed pot. In the AUTO mode it is used for the ratio control and in the MAN mode it is used for manual speed adjustment. Figure 4-6 Auto/Manual Operation with Potentiometer on BC145 Input - Connection for Models BC141, BC142, BC142-5, BC142-6 and BC155 Note: (1) For models BC154, BC154-SI, BC154-R, BCWD140, BC160, and BC354, connect BC145 terminal 9 (-) to terminal P1 instead of F (-). MN1373 4-4

LIMITED WARRANTY For a period of 2 years from date of original purchase, BALDOR will repair or replace without charge controls which our examination proves to be defective in material or workmanship. This warranty is valid if the unit has not been tampered with by unauthorized persons, misused, abused, or improperly installed and has been used in accordance with the instructions and/ or ratings supplied. This warranty is in lieu of any other warranty or guarantee expressed or implied. BALDOR shall not be held responsible for any expense (including installation and removal), inconvenience, or consequential damage, including injury to person, caused by items of our manufacture or sale. (Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion may not apply.) In any event, BALDOR s total liability, under all circumstances, shall not exceed the full purchase price of the control. Claims for purchase price refunds, repairs or replacements must be referred to BALDOR with all pertinent data as to the defect, the date purchased, the task performed by the control, and the problem encountered. No liability is assumed for expendable items such as fuses. Goods may be returned only with written notification including a BALDOR Return Authorization Number and any return shipments must be prepaid.

Baldor Electric Company P.O. Box 2400, Fort Smith, AR 72902-2400 U.S.A., Ph: (1) 479.646.4711, Fax (1) 479.648.5792, International Fax (1) 479.648.5895 www.baldor.com Baldor Electric Company MN1373 All Rights Reserved. (A42086) - Rev F - 04/17