NORMATIVE REFERENCES

Similar documents
NORMATIVE REFERENCES

COMMERCIAL ITEM DESCRIPTION RODS, GROUND (WITH ATTACHMENTS)

SECTION METAL FABRICATIONS

RR-F-191/1D 14 May SUPERCEDING RR-F-191/1C July 22, 1981 FEDERAL SPECIFICATION SHEET

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

Barofor Round System (polyester coated) Panels, Posts, Accessories

ICC-ES Evaluation Report

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

!"# $%& '()*(+%,-. /#--) 0"+.1%# --- บร ษ ท เอ นไซ กร ป จ าก ด ---

Ground Clamps Cable Tray

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt.

ODOT ITB Group 4 Item 33 Qty. 1

PART MATERIALS. Section Fencing Materials. Description

Peco Fasteners 3/8 Internal Plug Drop In 50 Per Jar 3/8-16 SMART DROP IN ANCHOR ZINC

Letter of Transmittal/Submittal

Steel Nipples. Nipples & Fittings. Black and Galvanized Steel Nipples. Black and Galvanized. Steel Nipples. 142

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

PIPE/CONDUIT SUPPORTS

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

Section 914. JOINT AND WATERPROOFING MATERIALS

Securifor Polyester Coated Welded Mesh Panels

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Cable & Bolt Cutters. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Standard Specification for Electric-Resistance-Welded Metallic-Coated Carbon Steel Mechanical Tubing 1

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

Sockets. Dimensions; Mechanical & Performance Requirements. Socket Head Cap Screws Body & Grip Lengths - Socket Cap Screws...

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

MILITARY SPECIFICATION SHEET SCREW, CAP, SOCKET HEAD- HEXAGON, CORROSION RESISTANT STEEL, UNC-3A

ESR-1799 Reissued June 1, 2009 This report is subject to re-examination in one year.

Large Diameter Tapcon

1. ANSI/ASME Standard B , Square and Hex Bolts and Screws, Inch Series

Standard Specification for Quenched and Tempered Steel Bolts and Studs 1

ESR-2024* Reissued September 1, 2011 This report is subject to renewal September 1, 2013.

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: MiTek USA, INC.

AUDAS. Tel: Fax: No.259 Baichi north Rd.Haiyan.Zhejiang.

ERECTION & CONSTRUCTION

C-Clamps and Lifting Eyes (Eye Bolts)

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

Standard Specification for High-Strength Bolts for Structural Steel Joints [Metric] 1

Thru Wall Floor Seals For New Installation

Evaluation of In-Pavement Light Fixture Designs and Performance

Designation: F

ICC-ES Evaluation Report Reissued June 1, 2011 This report is subject to renewal in one year.

Captive Quarter-turn Fasteners Continuous Receptacle Strip MIL-F-25173A * APPROVED

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

Cluster Block Housings and Contacts

Standard Specification for Steel Transmission Tower Bolts, Zinc-Coated and Bare 1

Standard Specification for Carbons and Alloy Steel Nuts 1

FEDERAL SPECIFICATION SHEET FENCING, WIRE AND POST, METAL (CHAIN-LINK FENCE ACCESSORIES) (DETAIL SPECIFICATION)


Standard Test Method for Rubber Deterioration Surface Cracking 1

Elcometer Conical Mandrel Bend Tester

Manufacturing Workmanship Standards. KSO Rev 1

General Information...SA1-SA4

Procedure for Testing Direct Tension Indicators (DTI) Assemblies

Standard Specification for Steel Transmission Tower Bolts, Zinc-Coated and Bare 1

METAL-TO-WOOD FASTENERS QUIKGRIP METAL2WOOD METAL2WOOD HD METAL2WOOD XD LOPRO 300SS. Value through the Roof.

Standard Specification for Carbon and Alloy Steel Nuts [Metric] 1

Housings and Contacts 20 JUL 11 Rev G

Standard Specification for Copper-Clad Steel Wire for Electronic Application 1

Hilti, Inc South 122 nd East Avenue Tulsa, OK

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

2. Conductor insulation should be supported and gripped by the terminal.

SUBMITTAL SHEET. Project Submittals by

Midwest Roadside Safety Facility

E-Z LOK Products are available from MARYLAND METRICS P.O. Box 261 MD USA

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: ASTROTECH STEELS PRIVATE LIMITED

METRIC FASTENERS 1520 METRIC FASTENERS

MIL-STD-1580B REQUIREMENT 11 DETAILED REQUIREMENTS FOR CONNECTORS

ESR-1799 Reissued April 2014 This report is subject to renewal June 1, 2015.

Evaluation Instructions Machining Level II CNC Milling

Design for Manufacturability Guide

METAL METAL

FOR UL INTERNAL REFERENCE OR CSDS USE ONLY NOT FOR OUTSIDE DISTRIBUTION

(Public Law ). Infasco Bolts are Original Equipment on both MACK and CATERPILLAR Products

Hex Cap Screws Coarse & Fine Thread

Foundation Specifications

Dimensions Mechanical and Performance Requirements. Drop-In Anchors Hollow Wall, Steel Regular Style Drive Style...

SECTION CABLE TRAYS

FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson.

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here)

Standard Specification for Fence Fittings 1

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Ford Water Meter Couplings & Accessories

Trusted ICC ES. Issued 06/2018 HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

Engineering Test Report

Standard Test Methods for Bend Testing of Material for Ductility 1

Manufacturing Workmanship Standards Implemented November 2011

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

TOOLING COMPONENTS. Clamping Kits Step Blocks & Kits Driver Studs Bolts, Screws Nuts, Washers...

Transcription:

American National Standards Institute NORMATIVE REFERENCES ANSI C135.30 1988 (expired 1993) Zinc-Coated Ferrous Ground Rod Electrodes for Overhead or Underground Lines American Society for Testing and Materials ASTM A-108 Standard Specification for Steel Bars, Carbon, Cold-Rolled ASTM A-123 Standard Specification for Zinc Coatings of Iron and Steel Products ASTM A-370 Standard Test Methods and Definitions for Mechanical Testing of Steel Products ASTM E-376-96 Standard Practice for Measuring Coating Thickness by Magnetic-Field or Eddy- Current Test Methods ASTM A510 Standard Specification for General Requirements for Wire Rods and Coarse Round Wire, Carbon Steel ASTM 571-97E1 Standard Practice for Qualitative Testing of Metallic Coatings Canadian Standards Association CSA C22.2 No. 41-M1987; Grounding and Bonding Equipment Canena THC-99 Standard (anticipated introduction late 2007) Underwriters Laboratories ANSI/UL467-1993; Standard for Grounding & Bonding Mexican Electrical Code NMX-J-567; Bonding & Grounding Canadian Electrical Code C22.2 No. 41; Bonding & Grounding Technical Engineering Service Sharp Edge Tester SET-50 Underwriters Laboratories UL467 Standard for Grounding & Bonding Equipment

1.0 Ground Rods Copper-Coated & Hot-Dip Galvanized Rods shall be listed for quality purposes and traceability by a Nationally Recognized Testing Laboratory (NRTL) such as ETL, UL, CSA, etc. to specification UL467. Material: The steel used in the production of the ground rod core shall meet the requirements of ASTM-A370, and shall have a minimum tensile strength of 80,000 PSI and a minimum Rockwell B hardness of 80. The rod s steel core shall be colddrawn to assure enhanced hardness and straightness. Length: Rod length tolerances shall be 0, + 5/8 inch for each size specified. Finished Diameters: Rod diameters (inches nominal) shall fall within the ranges listed below. Trade Size Finished Diameter Finished Diameter Threadless or Threaded Threadless Diameter Copper-Coated Zinc-Coated 1/2 0.500 0.510 0.484 0.500 5/8 0.555 0.565 0.539 0.555 5/8 Actual Size N/A 0.625 0.640 3/4 0.673 0.683 0.750 0.765 1 0.907 0.917 1.000 1.015. Note: RUS now accepts rods with 10 mils minimum of copper coating. Please refer to www.rurdev.usda.gov/supportdocuments/lom1207.pdf for official statement. Coating: The coating thickness for copper-coated rods shall not be less than 0.010 inch thick at any point on the rod when measured with an eddy-current device per ASTM E- 376. The coating thickness for 13-mil copper-coated rods shall not be less than 0.013 inch thick at any point on the rod when measured with an eddy-current device per ASTM E-376. Note: See www.rurdev.usda.gov/supportdocuments/lom1207.pdf for official statement regarding the acceptance of 10 mil rods. The coating thickness for zinc-coated rods shall not be less than 0.0039 inch thick at any point on the rod when measured in accordance with ASTM E-376. Zinc coated rods shall be hot-dip galvanized in accordance with ASTM A-123.

Threads: Threads on copper-coated sectional rods shall be of the roll-thread type, and shall conform on each end of the rod electrode per the following: Nominal Thread A UNC Thread B Diameter Length 1/16, + 1/8 Profile 1/2 1 1/16 9/16-12 5/8 1 3/16 5/8-11 3/4 1 1/2 3/4-10 1 1 11/16 1-8 A A B B Rod ends: The configuration of the chamfer and drive end of each rod shall conform to the following: A B 60 60 Nominal Conical Point End Chamfer End Diameter A B 1/2 3/16 3/32 5/8 3/16 1/8 3/4 1/4 1/8 1 3/8 7/32 Adhesion Test: An 18-inch length of the rod with one end cut to a 45 degree point shall be driven between two steel clamping plates, or the jaws of a vise set 0.04 inch less than the diameter of the rod, so as to shear off sufficient metal to expose the bond between the jacket and rod. Peeling of the jacket by the steel plates or the jaws of the vise is acceptable, but there shall be no other evidence of separation of the jacket from the steel core. Bend Test: There shall be no evidence of cracking of the jacket if at room temperature a length of the rod is rigidly held in a clamp or vise and the free end

bent by applying a force normal to the rod at a distance from the clamping device equal to 40 times the rod diameter. The magnitude of the force and the direction of application shall be such that the rod is permanently bent through a 30-degree angle without failure of the copper coating. Surface Evaluation: The surface of the ground rod, including point and chamfer ends, shall be smooth and uniform, and free from blisters, pitting, slivers, peeling, flaking and other types of sharp projections as safety criteria. Conformance to no sharp projections shall be tested using a Technical Engineering Service Company, Sharp Edge Tester, Model SET-50 device. There shall also be no evidence of cracking of the coating. Straightness: All ground rod electrodes shall be straight per the following test and acceptance criteria. A ground rod sample shall be supported by two V blocks with a dial feeler gage located at the mid-point of the V blocks per the following figure. While rotating the ground rod by hand, the maximum and minimum readings shall be recorded. The readings are to be subtracted for the total deviation. The average deviation from straight for the length of the ground rod located between the V blocks is determined by the following formula: Average Deviation = Maximum Deviation less Minimum Deviation 2 x 3 feet The straightness of the rod, per this calculation, shall not vary more than 0.25 inches/5 feet. Marking: The ground rod shall be permanently and legibly marked with the manufacturer s identification, and the catalog or equivalent designation, Beginning within the top 6 inches of the drive, or chamfer, end of the ground rod. In addition, a rod end shall be color-coded to identify diameter per the following: Copper-Coated: Nominal Diameter Threadless or Threaded ½ Non-Listed Green ½ Listed Orange 5/8 Non-Listed Red

5/8 Listed Copper 5/8 Full Size Yellow 3/4 Black 1 No Color Hot-Dip Galvanized: Nominal Diameter Threadless ½ Non-Listed Green 5/8 Copper 5/8 Full Size Yellow 3/4 Black 1 No Color Packaging: Rods shall be packaged in sub-bundles of five (5) rods, and master bundles shall be secured with metal banding. Master bundles shall consist of twenty (20) sub-bundles of 5 rods producing a master bundle of one hundred (100) rods. Exception to this will be ¾ inch diameter rods where the master bundle shall consist of 10 sub-bundles of 5 rods for a total master bundle of 50 rods, and 1 inch diameter rods where the master bundle shall consist of 5 sub-bundles of 5 rods for a total master bundle of 25 rods. 2.0 Ground Rods Stainless Steel Rods shall be listed for quality purposes and traceability by a Nationally Recognized Testing Laboratory (NRTL) such as ETL, UL, CSA, etc. to specification UL467. Material: The material shall be solid stainless steel. The steel used in the production of the ground rod shall be ANSI Type 304 Solid Stainless Steel, meet the requirements of ASTM-A370, and shall have a minimum tensile strength of 80,000 PSI and a minimum Rockwell B hardness of 80. Length: Rod length tolerances shall be 0, + 5/8 inch for each size specified. Diameters: Rod diameters (inches nominal) shall fall within the finished diameter ranges listed below. Diameter Full-Size Actual Finished Diameter Threadless or Threaded 5/8 0.625 0.635 3/4 0.750 0.765 1 1.000 1.020 All other characteristics of the stainless-steel rod shall meet the same criteria as the copper-coated and hot-dip galvanized referenced in section 1.0.

Packaging: Rods shall be packaged in sub-bundles of five (5) rods, and master bundles shall be secured with metal banding. Master bundles shall consist of twenty (20) sub-bundles of 5 rods producing a master bundle of one hundred (100) rods. Exception to this will be ¾ inch diameter rods where the master bundle shall consist of 10 sub-bundles of 5 rods for a total master bundle of 50 rods, and 1 inch diameter rods where the master bundle shall consist of 5 sub-bundles of 5 rods for a total master bundle of 25 rods. 3.0 Threaded & Threadless Couplings Material: Copper rod coupling material shall be Copper Alloy CDA-956000 containing not less than 80% copper, and shall be suitable for direct burial. Zinc-coated rod coupling material shall be Copper Alloy CDA-956000 or coatedsteel, and shall be suitable for direct burial. Stainless-steel rod coupling material shall be of stainless steel composition compatible with the rod, and shall be suitable for direct burial. Finish: The surface finish of the completed coupling shall be smooth and free of cracks, burrs and sharp projections. Conformance to no sharp projections shall be tested using a Technical Engineering Service Company, Sharp Edge Tester, Model SET-50 device. Length: The length of the coupling shall be sufficient to accommodate the threaded portion of two coupled ground rods and meet the performance requirements. Threads: Threaded couplings shall be symmetrical and shall accept electrodes of the following nominal sizes: Nominal Diameter UNC Thread Profile 1/2 9/16-12 UNC 5/8 5/8-11 UNC 3/4 ¾ -10 UNC 1 1-8 UNC Note: Threadless coupling shall be symmetrical and shall be compatible with threadless ground rods. Conductivity: The couplings in the assembled mode shall exhibit no less than 95% of the conductivity of an unspliced ground rod of equal length. Impact: Two 18-inch rod samples shall be coupled and held vertically in a tubular fixture that is at least 0.010 inch greater than the rod diameter. The penetrating end of the bottom ground rod shall be rested on a fixed plate of a weight sufficient to withstand the impact test, and located in a hole at least 4 inches in depth. The

coupling shall not rest on or be contained within the tubular fixture or fixture plate. The top ground rod shall be subjected to an impact force of 40 foot-pounds. After 25 impacts, the couplings shall not break, split, or be subjected to damage that impairs performance. Pullout: The joined coupling/rod assembly must withstand a pullout force of no less than 1500 pounds before separation. Bend: The coupling/rod assembly shall be subjected to the same bending requirements as an individual ground rod. The test specimen shall be gripped in a suitable rigid clamp or vise, and the ground rod bent by applying a force normal to the ground rod, at a distance of 40 times the rod diameter from the clamping device. The coupling shall be located midway between the clamping device and the point of applied force. The force shall be applied until the ground rod is permanently bent through an angle of 30 degrees. The coupling shall exhibit an sign of cracking or separation from the rod electrode. Marking: Couplings shall be marked with the manufacturer s name or trademark, and trade size. Each coupling package shall be marked with the manufacturer s name or trademark, and trade size. 4.0 Ground Rod Clamps Bolted & Compression Clamps shall be listed for quality purposes and traceability by a Nationally Recognized Testing Laboratory (NRTL) such as ETL, UL or CSA. Material: Copper rod coupling material shall be Copper Alloy CDA-956000 containing not less than 80% copper, and shall be suitable for direct burial. Hardware material must be either stainless steel or minimum 80% copper, suitable for direct burial and compatible with the coupling material. Finish: The surface finish of the completed coupling shall be smooth and free of cracks, burrs and sharp projections. Conformance to no sharp projections shall be tested using a Technical Engineering Service Company, Sharp Edge Tester, Model SET-50 device. Conductivity: The clamp in the assembled mode shall exhibit no less than 95% of the conductivity of a solid conductor. Pullout: The joined clamp/grounding conductor/rod electrode assembly must withstand a pullout force of no less than 500 pounds before separation. This test shall be performed by pulling on the grounding conductor with the rod held firmly in place, the clamp providing a securing function only. Marking: Clamps shall be marked with the manufacturer s name or trademark, and trade size. Each clamp package shall be marked with the manufacturer s name or trademark, and trade size.

Packaging: Clamps shall be packaged and marked with the part number, quantity, coupling size/nominal and bar code. Torque/Securance Requirements: Bolted Clamp: Assembly torque requirements shall fall within one of the following criteria with the appropriate thread characteristics: Duty Assembly Torque Thread Size Standard 350 inch-pounds 3/8-16 UNC Heavy 450 inch-pounds 7/16-14 UNC Extra Heavy 600 inch-pounds 1/2-13 UNC Compression Clamp: Hammer-on ground clamps shall provide sufficient force to facilitate a compression connection between the clamp and rod electrode. The grounding conductor shall be in direct contact with the rod electrode to assure a positive grounding path. Copyright 2013 GALVAN INDUSTRIES, INC. All Rights Reserved.