NJWA - Harmonics and Drives Proper System Design

Similar documents
Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

Harmonics White Paper

Understanding Input Harmonics and Techniques to Mitigate Them

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

APPLICATION GUIDE. Harmonics in HVAC applications

Effective Harmonic Mitigation with Active Filters

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

Harmonic Distortion and Variable Frequency Drives

Economical Solutions to Meet Harmonic Distortion Limits[4]

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

7/15/2002 PP.AFD.08 1 of 28

ABB DRIVES Technical guide No. 6 Guide to harmonics with AC drives

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Harmonic Filters and Reactors

1C.4.1 Harmonic Distortion

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Drives 101 Lesson 5. Power Input Terminology for a VFD

ZENER ELECTRIC PTY LTD

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

The increase in the application

Reliable power onboard and offshore

Power Factor & Harmonics

Analysis of Harmonic Distortion in Non-linear Loads

Understanding Harmonics

VFDs and Harmonics in HVAC Applications

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives

Low Pass Harmonic Filters

Thyristorised Automatic Power Factor

Peteris Spels, ABB Inc., WMEA, November 18, 2011 HARMONICS. ABB Group December 14, 2011 Slide 1

22.0 Harmonics in Industrial Power Systems

Harmonic Requirements

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Active Harmonic Filter (AF3)

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

CHAPTER 4 HARMONICS AND POWER FACTOR

Electromagnetic Harmonic Filters Technical Guide

ABB drives. Technical guide No. 6 Guide to harmonics with AC drives

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

ACS 1000 Transformer Failure Investigation. Nathan Schachter, Peng

Electrical Energy Saving and Economic Benefits from Power System Harmonics Mitigation in the Petrochemical Plants

External Drive Hardware

Technical Paper. Harmonic Distortion in Data Centers

CHAPTER 1 INTRODUCTION

International Journal of Advance Engineering and Research Development ANALYSIS AND MITIGATION OF HARMONICS IN MEDICAL FIELD

Effects of Harmonic Distortion I

Introduction to Rectifiers and their Performance Parameters

Comparison of Different Common Passive Filter Topologies for Harmonic Mitigation

Harmonic Distortion Evaluations

Harmonic control devices

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Open-Delta Systems Affect Variable Frequency Drives

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

An Active Interphase Transformer for 12-Pulse Rectifier System to Get the Performance Like 24- Pulse Rectifier System

Harmonic Filters for Single Phase Equipment

PFC Lite. How it works OMNIVERTER. OMNIVERTER November 14, 2015 Slide 1

Do Capacitor Switching Transients Still Cause Problems?

Simulation of H bridge Inverter used for Induction Melting Furnace

How Harmonics have led to 6 Power Factor Misconceptions

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Principles for Controlling Harmonics

Matrix Drives Boost Power Quality and Energy Savings

VARIABLE FREQUENCY DRIVE

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Design and Simulation of Passive Filter

Power Quality Analysis in Power System with Non Linear Load

AGN 026 Harmonic Voltage Distortion

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with MTE Matrix AP Harmonic Filter vs. 18-Pulse Drive

Emicon Engineering Consultants L.L.C.

Part Five. High-Power ac Drives

How adjustable speed drives affect power distribution

6L]LQJ$8366\VWHP )RU1RQ/LQHDU/RDGV

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

Reduce harmonics in HVAC&R inverters through C-Less technology

Harmonic Mitigating Transformer - Technical Guide

SHUNT ACTIVE POWER FILTER

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

Harmonics, its Mitigation & Result of Case study of Spinning Mill

Power Quality and Harmonic :Causes and Effects with Paper Mill Factory

Update on Conventional and Gearless Drive Systems for Draglines Industrial Solutions and Services Your Success is Our Goal

16B2011B1 EASY HARMONICS USER MANUAL

ABB n.v. Power Quality Products, October 2014

BUFFALO ENERGY SCIENCE AND TECHNOLOGY GROUP

Harmonic Filtering in Variable Speed Drives

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

MIRUS International Inc.

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with Matrix AP Harmonic Filter vs. AFE Drive

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Reducing Total Harmonic Distortion with Variable Frequency Drives

Active Harmonic Filter (AHF)

Mitigation of Harmonics and Interharmonics in VSI-Fed Adjustable Speed Drives

Transcription:

Session Goals Larry Stanley, Sr. Regional Business Development Engineer, Water Segment Matthew LaRue, ABB Drives Product Manager Philadelphia District, Baldor of Philadelphia NJWA - Harmonics and Drives Proper System Design Understand what harmonics are Understand why harmonics may be a concern Provide simple guidelines for when to be concerned Understand what options are available for addressing harmonic issues October 21, 2016 Slide 1 October 21, 2016 Slide 2 Harmonics What? Harmonics What? Non-linear loads draw non-sinusoidal current from a sinusoidal line (current doesn t look like voltage): Non-incandescent lighting Computers Uninterruptible power supplies Telecommunications equipment Copy machines Battery chargers Any load with a solid state AC to DC power converter Electronic variable speed drives October 21, 2016 Slide 3 October 21, 2016 Slide 4 Harmonics Key Concepts The Real World, 6- Pulse Drive Non-linear loads draw current in a periodic non-sinusoidal or distorted manner Line transients are not harmonics Harmonics or harmonic content is a mathematical concept implemented to allow quantification and simplified analysis of nonlinear waveforms Harmonics are typically present in both network currents and network voltages Non-linear current draw creates non-linear voltage as it flows through the electrical network Current harmonics Voltage harmonics PWM Drive Input Current October 21, 2016 Slide 5 October 21, 2016 Slide 6 1

The Theory: Fundamental, 5 th and 7 th Harmonics Harmonic Content, 6- Pulse Drive Fundamental 5th PWM Drive Harmonic Input Spectrum Components Fundamental 7th 5th Summation 7th 11th 13th October 21, 2016 Slide 7 October 21, 2016 Slide 8 Harmonics Why worry? Harmonics Why worry? Harmonic Current Distortion Added heating in transformers and cables, reduces available capacity May stimulate a PF correction resonance condition Excessive voltage Overheating of capacitors Tripping of protection equipment Shutdown / damage to electronic equipment May cause telephone or electronic interference October 21, 2016 Slide 9 October 21, 2016 Slide 10 Beware Harmonic Resonance Harmonics Why worry? (cont.) Harmonic Voltage Distortion Undamped power factor correction capacitors on the same bus as nonlinear loads may create a resonance condition with consequent severe bus voltage distortion and excessive peak voltage Increased heating in motors and other electromagnetic equipment Noisy operation of electromagnetic equipment Malfunction of sensitive electronics Nuisance tripping of electronic circuit breakers Equipment downtime Premature component failures Failed transformers, motors and capacitors Compliance with codes or specifications October 21, 2016 Slide 11 October 21, 2016 Slide 12 2

Harmonics, Important Terminology PCC Example (definitions per IEEE 519-1992) Harmonic - A sinusoidal component of a periodic wave or quantity having a frequency that is an integral multiple of the fundamental frequency. Harmonic, characteristic - Those harmonics produced by semiconductor converter equipment in the course of normal operation. h = kq ± 1 k = any integer q = pulse number of the converter Point of common coupling (PCC) Def. 1 - point of common coupling (PCC) with the consumer-utility interface. (current harmonic emphasis) Def. 2 - Within an industrial plant the point of common coupling is the point between the nonlinear load and other loads. (voltage harmonic emphasis) October 21, 2016 Slide 13 October 21, 2016 Slide 14 Harmonics, Important Terminology (cont.) Effect of Short Circuit Ratio on Harmonics I SC I L ~ 400 I SC I L ~ 8 I SC /I L - The ratio of the short-circuit current available at the point of common coupling, to the maximum fundamental load current. Total harmonic distortion (THD) or distortion factor - The ratio of the root-mean-square of the harmonic content to the rootmean-square value of the fundamental quantity, expressed as a percent of the fundamental. Total demand distortion (TDD) - The root-sum-square harmonic current distortion, in percent of the maximum demand load current (15 or 30 min demand). October 21, 2016 Slide 15 October 21, 2016 Slide 16 Harmonics - A System Issue! Harmonics By the Numbers Harmonics produced by an individual load are only important to the extent that they represent a significant portion of the total connected load (Harmonics are expressed as a percentage) IEEE 519-1992 Linear loads help reduce system harmonic levels (percentages) TDD (Total Demand Distortion) equals the THD (Total Harmonic Distortion) of the nonlinear load multiplied by the ratio of nonlinear load to the total (demand) load: Where TDD = TDD of the system THD NL = THD of the nonlinear loads NL = kva of nonlinear load TL = kva of total load (nonlinear + linear) October 21, 2016 Slide 17 October 21, 2016 Slide 18 3

Harmonics By the Numbers (cont.) R SC IEEE 519-1992 Harmonics By the Numbers (cont.) IEEE 519-1992 October 21, 2016 Slide 19 October 21, 2016 Slide 20 Harmonic Voltage, Will it be a problem? THD (Voltage) will be acceptable (<5%) if the % drive load times the % impedance feeding the drive load is <3% Harmonics Will it be a problem? %DriveLoad x %Impedance < 3% E.g. a 45% drive load fed from 6% impedance feeder bus: 45% x 6% = 2.7% 2.7% < 3% Acceptable E.g. a 70% drive load fed from 5% impedance feeder bus: 70% x 5% = 3.5% 3.5% > 3% Not Acceptable (Approximate rule of thumb for 6-pulse drives with 3% reactor, all other loads assumed to be linear) October 21, 2016 Slide 21 October 21, 2016 Slide 22 Harmonic Current, Will it be a problem? THD (Current) on a network with a short circuit ratio <20 (20<50, 50<100, 100<1000) will be acceptable if the % drive load times 45% is <5% (<8%, <12%, <15%) %DriveLoad x 45% < 5% (R SC <20) %DriveLoad x 45% < 8% (R SC 20<50) %DriveLoad x 45% < 12% (R SC 50<100) %DriveLoad x 45% < 15% (R SC 100<1000) E.g. a network with a short circuit ratio of 35 has 15% drive load: 15% x 45% = 6.75% 6.75% < 8% Acceptable E.g. a network with a short circuit ratio of 65 has 30% drive load: 30% x 45% = 13.5% 13.5% > 12% Not Acceptable Harmonics What can I do? (Rule of thumb for 6-pulse drives with 3% reactor,, all other loads assumed to be linear) October 21, 2016 Slide 23 October 21, 2016 Slide 24 4

Harmonics What can I do? Reactors (Chokes) Reactors (Chokes) Passive Filters Harmonic Trap Hybrid High Pulse Count Rectification Active Filters Stand Alone Drive Active Front End Simplest and least expensive harmonic reduction technique May be included in base drive package Often meet harmonic needs provided drive load is a small portion of total connected load May be implemented with AC line reactors or with DC link reactors AC line reactors provide better input protection DC link reactors provide load insensitive drive output voltage Both types provide similar harmonic benefits Swinging choke design provides enhanced light load harmonic performance October 21, 2016 Slide 25 October 21, 2016 Slide 26 Reactors, AC Line or DC Link Reactor Effectiveness Different design techniques Equal harmonic reduction for same normalized % reactance Typical full load THD (current) at drive input terminals 28% 46% Current harmonic content (THD) at drive input terminals as a function of normalized % reactance and network short circuit ratio Existence - not position - is what is important October 21, 2016 Slide 27 October 21, 2016 Slide 28 Swinging Chokes Swinging DC Link Choke Designed to reduce harmonics at full and partial loads Perfect for Variable Torque Centrifugal Loads Equivalent to 5% line reactor More inductance per volume/weight of material Provide increased inductance at reduced current Reduce harmonics up to 30% more than traditional designs Swing portion of choke characteristic significantly improves harmonic performance at reduced loads October 21, 2016 Slide 29 October 21, 2016 Slide 30 5

Swinging Choke Vs. Fixed Choke Harmonic Trap Filter Optional Installs in series with drive input May feed multiple drives Improves power factor (may go leading) Typical full load THD (current) at filter input terminals (line side) 10% 14% Performance reduced by line imbalance October 21, 2016 Slide 31 October 21, 2016 Slide 32 Hybrid Filter High Pulse Count Rectification Installs in series with drive input May feed multiple drives Improves power factor (may go leading) Typical full load THD (current) at filter input terminals (line side) 5% 8% Relatively unaffected by line imbalance Typical configurations are either 12 pulse or 18 pulse Phase shifting transformer is required Additional drive input bridges are needed Typical full load THD (current) at transformer primary 8% 12% (12 pulse), 4% 6% (18 pulse) Performance significantly reduced by line imbalance (voltage or phase) Excellent choice if stepdown transformer is already required October 21, 2016 Slide 33 October 21, 2016 Slide 34 High Pulse Count Rectification (cont.) Harmonic Cancellation, 5th 6 pulse rectifier 18 pulse rectifier DC/AC Transformer (if included) and cabling simple 12 pulse rectifier DC/AC DC/AC Transformer and cabling complicated Current quite distorted I thd 32% to 48% with 3% reactor (depending on network impedance) Transformer and cabling more complicated Current wave form good I thd 4% to 6% (depending on network impedance) Current slightly distorted I thd 8% to 12% (depending on network impedance) October 21, 2016 Slide 35 October 21, 2016 Slide 36 6

Harmonic Cancellation, 7th Active Front End Filter October 21, 2016 Slide 37 October 21, 2016 Slide 38 Active Filter Front End with LCL Filter Beauty Instead of Beast October 21, 2016 Slide 39 Drive L C LCL filter L Line inverter (rectifier) DC Link Motor inverter Motor Active Filter Line Inverter removes low frequencies < 1kHz LCL Filter (passive filter) removes high frequencies >1 khz. (Current and voltage) Full output voltage is available with 80% input voltage (400V In = 480V Out ) Full regenerative capability (ACS800-U11/-17) No transformer required Not affected by line imbalance M IGBT line supply controls the current Sinusoidal line current Low distortion below switching frequency LCL Line filter removes high frequency distortion Cleans the waveform above switching frequency October 21, 2016 Slide 40 Diode supply Impressive Numbers Active Front End Drive, Construction Inverter module Total current distortion less than 3.5% to 4.5% Total voltage distortion less than 5% Power factor adjustable from 0.85 (leading or lagging) to 1.0 %THD (Voltage) = f(r SC) 5 4 3 Converter module Main switch 2 1 0 10 20 30 40 50 60 70 80 90 100 R SC Main contactor LCL-filter module October 21, 2016 Slide 41 October 21, 2016 Slide 42 7

Product offering 18-Pulse Impedance and Imbalance Dependencies Wall-mounted low harmonic drive ACS800- U31 10 125 HP ULH Clearly Superior 18 Pulse with 12 Pulse Performance Cabinet-built low harmonic drive ACS800-37 75-2800 HP October 21, 2016 Slide 43 October 21, 2016 Slide 44 Harmonic Reduction Summary Remember! Even an 80% THD nonlinear load with a will result in only 8% TDD if the nonlinear load is 10% and the linear load is 90%. (80% (10%/(10%+90%))=8%) October 21, 2016 Slide 45 8