Using Harmonic External Mixers To Extend the Frequency Range Application Note

Similar documents
Noise Figure Measurement in the 60 GHz Range Application Note

Power Added Efficiency Measurement with R&S ZNB/ R&S ZVA

Measurement Setup for Phase Noise Test at Frequencies above 50 GHz Application Note

Noise Figure Measurement Applications Specifications

GSM/EDGE Application Firmware R&S FS-K5 for R&S FSP and R&S FSU

1 Introduction: frequency stability and accuracy

Application Firmware for Phase Noise Measurements FS-K40

R&S ZVT Vector Network Analyzer Specifications

R&S ZVA-Zxx Millimeter-Wave Converters Network analysis up to 500 GHz

Conversion Gain Measurements on Mixers with Different Input and Output Impedances

R&S ZV-Z5x Calibration Units Specifications

R&S FU129 Antenna Filter Unit Antenna switching, rotator control and signal attenuation, amplification and filtering

Harmonic Mixer. R&S FS-Z90 (40 GHz to 60 GHz) R&S FS-Z60 R&S FS-Z75. R&S FS-Z110 (50 GHz to 75 GHz) Operating Manual. (60 GHz to 90 GHz)

R&S ZV-Z5x Calibration Units Specifications

R&S ZVT Vector Network Analyzer Specifications

R&S ZNB Vector Network Analyzer Specifications

R&S ZNC Vector Network Analyzer Specifications

Measuring Frequency Settling Time for Synthesizers and Transmitters

Wideband mm-wave Signal Generation and Analysis

Program for Frequency Response Measurements FreRes

R&S ZV-Z135 Calibration Kit Specifications

Modulation Accuracy Measurements of DVB-S2 and DVB-S2X Signals Application Note

LabWindows/CVI, VXIpnp driver history for the R&S Radio Tester

R&S FSUP Signal Source Analyzer Specifications

R&S EB500 Monitoring Receiver Specifications

Transmitter Tests in Accordance with the CTIA Plan for Wi-Fi Mobile Converged Devices

R&S FPC-Z10 Teaching Kit Getting Started

Group Delay measurements with Signal and Spectrum Analyzers Application Note

Vector Network Analyzers ZVB

R&S ZNBT8 Vector Network Analyzer Specifications

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

R&S CMU-Z10/-Z11 Antenna Coupler/ RF Shielding Cover Simple interference-free testing of all mobiles

Advanced Test Equipment Rentals ATEC (2832)

R&S FSC Spectrum Analyzer Specifications

R&S ZV-Z3xx T-Checker Specifications

Spectrum and signal analyzers for every requirement an overview

Evolution of the Modern Receiver in a Crowded Spectrum Environment White Paper

Signal Generators for Anritsu RF and Microwave Handheld Instruments

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

R&S ESCI/ESCI7 EMI Test Receiver Specifications

R&S FSH4/8 Spectrum Analyzer Specifications

Optimize External Mixer Operation for Improved Conversion Loss Performance.

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

R&S SMA100A Signal Generator The new standard of excellence in the analog signal generator class

Analog Modulation Analysis (AM/FM/φM) Specifications

Testing S-Parameters on Pulsed Radar Power Amplifier Modules

Using the FREQUENCY CONVERSION Mode of Vector Network Analyzer ZVR

Thermal Power Sensor

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Application Note TS-EMF. System for RF Exposure Measurements. System Check with Tri-Axis Sensor (Isotropic Antenna)

R&S RSC Step Attenuator Specifications

R&S FSV-K54 EMI Measurement Application User Manual

1 MHz 6 GHz RF Mixer with built in PLL Synthesizer

Testing Millimeter-Wave Mixers Using Converters of the R&S ZVA Family

Attenuators and Matching Pads, Terminations 75 mw to 1000 W, DC to 18 GHz

Generating Interference Signals Using the R&S SFU-K37 Option

Handheld Spectrum Analyzer R&S FSH3

Ultra High Frequency Measurements

R&S FSH Handheld Spectrum Analyzer Where mobility counts

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

Spectrum Analyzer R&S FS300

R&S FSV Signal and Spectrum Analyzer Specifications

Automated Measurements of 77 GHz FMCW Radar Signals

Firmware Release 4.76

R&S ZVH Cable and Antenna Analyzer Specifications

Harmonic Mixers And their application with Spectrum Analysers Application Note Revision: February 2009

Guide Version Five techniques for fast, accurate power integrity measurements

PXIe Contents CALIBRATION PROCEDURE

Measuring Receiver FSMR

Spectrum Analyzer FSU

External Source Control

R&S SMZ Frequency Multiplier Precise andadjustable output levels from 50 GHz to 110 GHz

Measurement of conducted EMI when using a switching power supply

Voltage Sensors URV5-Z

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Handheld Spectrum Analyzer R&S FSH3

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

Spectrum Analyzer FSU

R&S TS8997 Regulatory Test System for Wireless Devices

R&S FSx-K91/-K91n, R&S FSW/FSQ-K91ac WLAN Application Firmware WLAN TX measurements with Rohde & Schwarz analyzers

R&S FS-K112PC NFC Measurement Software Specifications

Appnote - Realtime Spectrum Analyzer vs Spectrum Analyzer

Spectrum Analyzer FSL

Technologies Vector Reflectometers

R&S FSV Signal Analyzer Specifications

Configuration of PNA-X, NVNA and X parameters

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

R3131A. Advanced Test Equipment Rentals ATEC (2832) A personal spectrum analyzer for use in diverse applications R3131A

R&S ZVL Vector Network Analyzer Specifications

R&S FSH4/FSH8 Handheld Spectrum Analyzer Where mobility counts

R&S ESRP EMI Test Receiver Specifications

R&S FSWP Phase Noise Analyzer Specifications

ENY81 Coupling Network

Spectrum Analyzers FSEA, FSEB, FSEM, FSEK

Signal Generator SMA100A

DSA700 Series Spectrum Analyzer

Test & Measurement. Technical Information. R&S ZV-WR10 / -WR12 / -WR15 Calibration Kits

OBJECTIVES EQUIPMENT LIST

Gain Compression Simulation

R&S FSWP Phase Noise Analyzer Specifications

Transcription:

Using Harmonic External Mixers To Extend the Frequency Range Application Note Products: R&S FSV R&S FSVR R&S FSQ R&S FSU R&S FSP R&S FSE This application note gives a short summary on how to use harmonic mixers in combination with Signal and Spectrum Analyzers. Focus of this application note is the use of conversion loss tables with different R&S analyzers. It also provides a tool to convert different formats of the conversion loss tables. Application Note Dr. Florian Ramian August 2010

Table of Contents Table of Contents 1 Using Harmonic Mixers to Extend the Frequency Range... 3 1.1 Operating Harmonic Mixers in combination with R&S Spectrum Analyzers...4 1.1.1 Local Oscillator and IF Frequencies of different Spectrum Analyzer families...4 1.1.2 Support of 3 port and 2 port mixers...5 1.1.3 Signal identification (Image suppression)...5 2 Characteristics of an External Mixer: Conversion Loss... 6 2.1 Overview...6 2.2 Conversion Loss Definition...6 2.3 How to measure the Conversion Loss of a Mixer...7 3 Using Conversion Loss Tables with R&S Analyzers... 7 3.1 Formats in Use for R&S Spectrum Analyzers...7 3.1.1 ASCII Format...7 3.1.2 Binary Format...7 3.2 Setting up an R&S Spectrum Analyzer for External Mixer operation...8 3.2.1 R&S FSV...8 3.2.2 R&S FSU...9 3.3 A sample Conversion Loss Table...12 3.4 Conversion Tool...12 4 Literature... 13 5 Ordering Information... 13 Using Harmonic External Mixers To Extend the Frequency Range 2

Using Harmonic Mixers to Extend the Frequency Range 1 Using Harmonic Mixers to Extend the Frequency Range Spectrum analyzers make use of harmonic mixers to increase their frequency range. Every harmonic mixer covers a specified frequency band, whose frequency range is dependent on the dimensions of the waveguide used as a connector to the DUT. Typical frequency ranges are therefore 40 to 60 GHz (U-band), 50 to 75 GHz (V-band), 60 to 90 GHz (E-band) and 75 to 110 GHz (W-band). A list of harmonic mixers available from is appended in chapter "Ordering information". A harmonic mixer is placed in the signal path between the DUT and the RF frontend of the spectrum analyzer. It down-converts its specified frequency band to one of the intermediate frequencies (IF) of the analyzer, which is made available via a dedicated input connector. To perform the frequency conversion, harmonic mixers need a so called local oscillator signal (LO), which must be provided by the spectrum analyzer as an output signal. RF signal ( input ) IF signal ( output ) Local oscillator Figure 1: Block circuit of an external mixer The frequency conversion complies with the following equation f IF = f RF n f LO, (1) where n equals the order of the harmonic of the local oscillator being used. To cover a complete frequency band this means that the analyzer must provide a sweeping LO signal, which subsequently converts the RF at each frequency of the selected band to the fixed intermediate frequency. By creating the IF signal directly the harmonic mixer bypasses the inbuilt microwave module of the spectrum analyzer. This is why the external mixing solution lacks a tunable filter and therefore yields image signals. To distinguish true signals from image signals, modern spectrum analyzers provide software algorithms (so called software preselectors), which detect and eliminate the image frequencies before drawing the measured curve on the screen. For more details on harmonic mixing, see Application Notes 1EF43_0E and 1GP65_0E, references [1] and [2]. Using Harmonic External Mixers To Extend the Frequency Range 3

Using Harmonic Mixers to Extend the Frequency Range 1.1 Operating Harmonic Mixers in combination with R&S Spectrum Analyzers 1.1.1 Local Oscillator and IF Frequencies of different Spectrum Analyzer families 1st IF 2nd IF 3rd IF 1st IF filter 2nd IF filter RBW filter Spectrum Analyzer RF input 1st LO (tunable) 2nd LO (fixed) 3rd LO (fixed) RF input port Harmonic mixer LO output port Spectrum Analyzer IF input port Spectrum Analyzer Spectrum Analyzer External Harmonic Mixer External Harmonic Mixer Figure 2: Spectrum Analyzer block diagram with a harmonic mixer attached Figure 2 shows a block diagram of a modern spectrum analyzer that is operated with a harmonic mixer. Depending on the concept, the IF stages are located at different frequencies. Therefore, the tuning ranges of the local oscillators are also different. The local oscillator frequency ranges for R&S spectrum analyzers are 7.73 GHz to 15.23 GHz for the R&S FSV and R&S FSVR 7.00 GHz to 15.50 GHz for the R&S FSU/FSQ family 7.00 GHz to 13.20 GHz for the R&S FSP family. The fundamental frequency of the local oscillator is too low to directly down-convert frequencies at 40 GHz or above. The conversion therefore uses the n-th harmonic of the LO frequency, with n being the necessary factor to reach the desired frequency range. The R&S FSV for example uses the 6 th harmonic for down-conversion of the E band (60 to 90 GHz). Depending on the LO frequency range a single harmonic might not be sufficient to fully cover the frequency range of a microwave band. Modern spectrum analyzers, like the R&S FSV, therefore offer the possibility to switch the harmonic number within the microwave band. The required IF frequency depends on the frequency concept of the spectrum analyzer. For R&S spectrum analyzers, it is 729.9 MHz for R&S FSV and FSVR 404.4 MHz for R&S FSU/FSQ and FSP families. Using Harmonic External Mixers To Extend the Frequency Range 4

Using Harmonic Mixers to Extend the Frequency Range From the different LO frequency ranges and the different IFs available in these instrument models, it is obvious that the number of the LO harmonic used for downconversion of a microwave band is different for the individual spectrum analyzer families. In order to use an external harmonic mixer, it is necessary to access the local oscillator (LO) and intermediate frequency (IF) signals of the spectrum analyzer. Therefore the options R&S FSP-B21, R&S FSU-B21, and R&S FSV-B21 provide access to the 1 st LO and 2 nd IF by means of two female SMA connectors. 1.1.2 Support of 3 port and 2 port mixers As shown in figure 1, a harmonic mixer basically has 3 ports: RF input, LO input and IF output. As the LO frequency range is much higher than the IF frequency used, some external mixers combine these two signals at one port. These mixers are therefore only two port devices, i.e. they have an RF input port and a combined LO in / IF out port. To support both types of mixers, the LO out port of all B21 options can also be used as a combined LO out / IF in port. This means that all B21 options are suitable for 2- as well as 3-port mixers. 1.1.3 Signal identification (Image suppression) The absolute value function in equation (1) indicates that there are always two RF frequencies the real frequency and its image frequency - which will be converted to the same IF frequency. To distinguish between the real signal and its image, modern spectrum analyzers use a mechanism called Signal Identification (see AppNote 1EF43_0E). The principle of the Signal Identification algorithm is simple. According to equation (2) the same RF frequency is converted to a given IF frequency by two LO frequencies at a distance of twice the IF frequency: f = n f ± f, (2) RF LO If the spectrum analyzer performs two sweeps with LO frequencies at a distance of twice the IF, the wanted RF signals will remain at the same position in the resulting trace, whereas the image signals will be shifted in frequency. With this knowledge, it is easy to eliminate the image signals from the displayed trace. More details can be found in reference [1]. IF Using Harmonic External Mixers To Extend the Frequency Range 5

Characteristics of an External Mixer: Conversion Loss 2 Characteristics of an External Mixer: Conversion Loss 2.1 Overview The conversion loss of a mixer specifies how efficiently a mixer converts the signal energy from the input frequency (RF) to the output frequency (IF). It is defined as the ratio of the input power to the output power of one sideband, measured in db at a given LO level. As the conversion loss of a mixer is frequency dependent, it is usually specified in tables which contain a list of frequencies and the corresponding conversion loss values. When loaded into a spectrum analyzer the conversion loss table increases the level accuracy of the results obtained from the harmonic mixer, as it allows the analyzer to take the frequency characteristics of the mixer into account. 2.2 Conversion Loss Definition An inherent conversion loss results from the mixing principle, which is 3 db for each sideband. A passive mixer, which is composed of diodes, causes additional attenuation of the input signal power. The resulting conversion loss varies with the applied LO power. At a certain LO level, the conversion loss reaches a minimum and thus the mixer should be operated at this optimal power level. As the frequency of the IF signal (mixer output) is different from the RF signal frequency (mixer input) as described in section 1, both frequencies appear in the conversion loss definition. A conversion loss is specified as K ( f ) RF = P log 10 P IF ( f ) RF RF 10, (3) with K being the conversion loss, which is dependent on the input frequency. Clearly, the equation also shows a dependency on the intermediate frequency, but with the local oscillator characteristics known, the IF can be derived from the RF signal. The conversion loss is specified at a certain power level of the LO signal, the drive level, as this determines the operating point of the mixer. During production of the harmonic mixer, the conversion loss is measured for the complete frequency range of the mixer. The resulting tables contain the frequency response characteristics of the mixer. To avoid the need for conversion loss tables, spectrum analyzers with an external mixer option also allow the usage of an average conversion loss, i.e. a number for the conversion loss that is constant over the entire frequency range. Usage of an average conversion loss number yields the advantage of easier handling, i.e. there is just one number to enter, at the cost of reduced level measurement accuracy. ( f IF ) P LO Using Harmonic External Mixers To Extend the Frequency Range 6

Using Conversion Loss Tables with R&S Analyzers 2.3 How to measure the Conversion Loss of a Mixer To characterize a mixer, a measurement of the device specific conversion loss needs to be performed. For conversion loss measurement, a sinusoidal input signal with known power level over frequency is required at the mixer input. Furthermore, the measurement requires the local oscillator to be operated at the power level which will be used later in the environment the conversion loss table is dedicated to. With these prerequisites, the RF signal is tuned over the frequency band limits in k discrete steps. For each step, the IF power at the mixer output is measured and normalized to the RF input power. The result is a conversion loss table, e.g. for the U band (40-60 GHz): RF Frequency 40 GHz 17.4 db Conversion Loss 60 GHz 18.6 db 3 Using Conversion Loss Tables with R&S Analyzers 3.1 Formats in Use for R&S Spectrum Analyzers 3.1.1 ASCII Format All R&S spectrum analyzers of the R&S FSP, FSU, FSV, and FSVR families require ASCII format conversion loss tables for the external mixer operation mode. The tables can be read using any text editor and may also be edited, but it is strongly recommended to use the edit function of the analyzer firmware, as explained in section 3.2. 3.1.2 Binary Format A binary format of the conversion loss table was used with R&S FSE family spectrum analyzers. External mixers sold as accessory to FSE family spectrum analyzers were delivered with conversion loss tables in binary format. To make these tables available for newer R&S spectrum analyzers that require ASCII format tables, a conversion tool comes with this application note, see section 3.4. Using Harmonic External Mixers To Extend the Frequency Range 7

Using Conversion Loss Tables with R&S Analyzers 3.2 Setting up an R&S Spectrum Analyzer for External Mixer operation 3.2.1 R&S FSV To open the configuration dialog on a R&S FSV with option FSV-B21, press FREQ External Mixer External Mixer Config to open the configuration dialog. Select the band that the mixer was designed for or USER if none of the displayed bands fits. Having selected the frequency band also determines the RF start and stop frequencies. For all predefined bands, these are the band limits, whereas for the user defined band, it is the maximum range that can be covered using the LO range of the R&S FSV in combination with the selected harmonic. The checkbox RF Overrange allows the usage of a mixer beyond the frequency limits of the selected band. In this case, the settable RF frequency is limited by the LO range and the selected harmonic, as is the case for the USER band. For further configuration, select the Harmonic Type. For double diode mixers, such as the R&S FS-Z60, Z75, Z90, and Z110, it will in general be an even harmonic only, i.e. select Even. Finally the conversion loss can be set for a single range. If two different harmonics are used to cover the band, Range 2 has to be set up in the same way for the other harmonic in use. To use an external mixer with the 6 th harmonic of the LO and a conversion loss table named table.cvl : Check Range 1 Set the Harmonic Type to Even Set the Harmonic Number to 6 Press the Table Button Select IMPORT TABLE from the dropdown box Navigate to the directory of table.cvl, select the file Press Select Select table.cvl from the dropdown box. Using Harmonic External Mixers To Extend the Frequency Range 8

Using Conversion Loss Tables with R&S Analyzers Figure 3: R&S FSV External Mixer Configuration dialog Alternatively, the conversion loss table can also be imported in the Conversion Loss Table Setup tab. Instead of importing, a conversion loss table can also be generated if the conversion loss values are known. Switch to the Conversion Loss Table Setup tab Press New Table Fill in the File Name, the Band, Harmonic Order, Bias, and the Mixer Type (2- or 3-port). Optionally, the fields Comment, Mixer Name, and Mixer S/N may be used for additional data. For each conversion loss value o Press Insert Value o Enter Position (frequency) o Enter Value (conversion loss) Press Save After having pressed Save, the generated conversion loss table is available for selection in the Conversion Loss dropdown box. As mentioned in section 2.2, an average conversion loss for the entire band may be used. The setup is identical to the above, except that Average is chosen instead of Table and a single value is specified instead of a conversion loss file. 3.2.2 R&S FSU To open the configuration settings for external mixer operation on an R&S FSU or R&S FSQ with option FSU-B21, press Using Harmonic External Mixers To Extend the Frequency Range 9

Using Conversion Loss Tables with R&S Analyzers FREQ EXTERNAL MIXER EXT MIXER ON SELECT BAND to open the band selection dialog. To use an external mixer with an average conversion loss for the entire band Check the appropriate band Specify the mixer specific values, such as harmonic, number of ports, and bias in the respective columns Modify the value in column AVG CONV LOSS/dB. To configure an external mixing setup using a conversion loss table as shown in Figure 4, the table must be imported first. Figure 4: Selecting a U band external mixer and the corresponding conversion loss table If the table is available in the acl ASCII format, it can be imported to the R&S FSU from any other storage medium, such as a USB stick. A table cannot be selected if it was not imported. To import a table Press CONV LOSS TABLE in the external mixer softkey menu Press LOAD TABLE Select the respective file in the open dialog Press Open. The table will now be available for selection. Alternatively, a new table can be generated. To generate a new table, stay in the conversion loss table dialog and Using Harmonic External Mixers To Extend the Frequency Range 10

Using Conversion Loss Tables with R&S Analyzers Press NEW TABLE Enter a suitable name For each conversion loss value o Press INSERT LINE o Enter Position (frequency) o Enter Value (conversion loss) Press SAVE Please note: The name of the conversion loss table is automatically extended by an underscore and an integer value, e.g. _4. The integer value corresponds to the harmonic order of the LO signal being used. A file without this extension cannot be selected later on. It is also important to have exactly the band start frequency as the first value in the conversion loss table and exactly the band stop frequency as the last value in the table. If these criteria are not fulfilled, the table cannot be selected. Figure 5 shows the conversion loss edit dialog, including the filename extended by _4 and the first value in the table being at 40 GHz, exactly the band start frequency. Figure 5: Editing a conversion loss table on an R&S FSU Back in the band selection dialog, the newly generated or loaded tables can now be selected for use by Pressing Enter in the corresponding line of column CONV LOSS TABLE Selecting the appropriate conversion loss table from the list of available tables as shown in Figure 4. Please note: Pressing Enter in the CONV LOSS TABLE column lists only those tables for selection that match the conditions mentioned above. These are: Tables need to have the harmonic order in the file name Using Harmonic External Mixers To Extend the Frequency Range 11

Using Conversion Loss Tables with R&S Analyzers Tables need to have the band start frequency as the first value and the band stop frequency as the last frequency value. 3.3 A sample Conversion Loss Table Although it is not recommended to set up a table manually, a sample conversion loss table in ASCII format is shown here. The table below is a table, with only six entries for a U band mixer that was generated on an R&S FSV. # Mixer Name My U band mixer # Serial Number 123456 # Band U # Number of Harmonic 4 # Bias 0.000000 # Ports 2 # Comment # Date 1.JUN.10 # Calibration data (40000000000.000000, 18.000000) (45000000000.000000, 19.000000) (50000000000.000000, 20.000000) (55000000000.000000, 21.000000) (59000000000.000000, 22.000000) (60000000000.000000, 23.000000) 3.4 Conversion Tool This application note comes with a conversion tool which allows the conversion of binary conversion loss tables from the R&S FSE family into ASCII conversion loss tables for the R&S FSP, R&S FSU, and R&S FSV families. The program is not only capable of converting binary data in to ASCII data, but also calculates the correct harmonic order for the given mixer and spectrum analyzer. The program is called with two parameters ConversionTool -TargetFamily FileName Where -TargetFamily is one out of -fsp,-fsu,-fsv. It specifies the target spectrum analyzer. FileName is the filename of the original file. The file extension tells the program whether to read it in binary or text form. A file with extension cl is read binary, all others as ASCII files. Using Harmonic External Mixers To Extend the Frequency Range 12

Literature 4 Literature [1] Rauscher, Christoph. Frequency Range Extension of Spectrum Analyzers with Harmonic Mixers. Application Note 1EF43_0E.. [2] Tröster, C., Thümmler, F., and Röder, T. Upconverting Modulated Signals to Microwave with an External Mixer and the R&S SMF100A Microwave Signal Generator. Application Note 1GP65_0E.. 5 Ordering Information R&S FS-Z60 Harmonic mixer 40 GHz to 60 GHz 1089.0799.02 R&S FS-Z75 Harmonic mixer 50 GHz to 75 GHz 1089.0847.02 R&S FS-Z90 Harmonic mixer 60 GHz to 90 GHz 1089.0899.02 R&S FS-Z110 Harmonic mixer 75 GHz to 110 GHz 1089.0947.04 R&S FSV30 Signal and Spectrum Analyzer 9 khz to 30 GHz 1307.9002.30 R&S FSV40 Signal and Spectrum Analyzer 9 khz to 40 GHz 1307.9002.40 R&S FSV-B21 LO/IF connections for external mixers for R&S FSV and R&S FSVR 1310.9597.02 R&S FSVR30 Real-Time Spectrum Analyzer 10 Hz to 30 GHz 1311.0006.30 R&S FSU26 Spectrum Analyzer 20 Hz to 26.5 GHz 1166.1660.26 R&S FSU46 Spectrum Analyzer 20 Hz to 46 GHz 1166.1660.46 R&S FSU50 Spectrum Analyzer 20 Hz to 50 GHz 1166.1660.50 R&S FSU67 Spectrum Analyzer 20 Hz to 67 GHz 1166.1660.67 R&S FSQ26 Signal Analyzer 20 Hz to 26.5 GHz 1166.1660.26 R&S FSQ40 Signal Analyzer 20 Hz to 40 GHz 1166.1660.40 R&S FSU-B21 LO/IF connections for external mixers for R&S FSU and R&S FSQ 1157.1090.02 Using Harmonic External Mixers To Extend the Frequency Range 13

About is an independent group of companies specializing in electronics. It is a leading supplier of solutions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure communications. Established 75 years ago, has a global presence and a dedicated service network in over 70 countries. Company headquarters are in Munich, Germany. Environmental commitment Energy-efficient products Continuous improvement in environmental sustainability ISO 14001-certified environmental management system Regional contact USA & Canada USA: 1-888-TEST-RSA (1-888-837-8772) from outside USA: +1 410 910 7800 CustomerSupport@rohde-schwarz.com East Asia +65 65 13 04 88 CustomerSupport@rohde-schwarz.com Rest of the World +49 89 4129 137 74 CustomerSupport@rohde-schwarz.com This application note and the supplied programs may only be used subject to the conditions of use set forth in the download area of the website. GmbH & Co. KG Mühldorfstraße 15 D - 81671 München Phone + 49 89 4129-0 Fax + 49 89 4129 13777