PQube 3 Specifications

Similar documents
PQube 3 Specifications

PSL - Power Sensors Ltd

PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

ProQube AC Power Monitor

PQM3000RGW Class A rack 19 power quality analyzer with Rogowski coils

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

PQube 3 Firmware 3.5.0

PQM3000R Class A network analyzer according to EN for power quality monitoring

Side view View from below Rear view

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

ARCO 400. Technical Data

Smart Energy & Power Quality Solutions. Power Quality Analyser UMG 512-PRO. Data sheet

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

AMIK 200 / 201 Technical Data Sheet

satech SynchroStar GPS 200 Series

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

3 Phase Power Quality Analy er

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

1 INTRODUCTION ORDER CODE / INFORMATION

Fluke 1750 Three-Phase Power Recorder

Network Analyzer for Low-, Medium- and High-Voltage Networks

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

UMG 509-PRO. Multifunction power analyser with RCM

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

Multimeter 500CVD21 RTU500 series

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Reliable Power Meters Multipoint Power Recorder

Overcurrent Protection / 7SJ45

Power Quality Analyzer / High Frequency Recorder

DM-5 Power Quality Analyzer

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

B850 Boiler House Energy Monitor

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

A Power Quality Interface for Low and Medium Voltage Smart Grids

B850 Boiler House Energy Monitor

Data Sheet. RISH Master Record %THD

High precision measurement system for current and voltage IHC-A/B-RM01/03

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Energy Management Energy Analyzer Type EM210 MID

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Fluke 3540 FC Three-Phase Power Monitor

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Power Meter Series PM3200 Functions and characteristics

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Specifications. 744 Users Manual

Fluke 3540 FC Three-Phase Power Monitor

Energy Management Three-phase energy meter with output modules Type EM4-DIN

RS Pro ENGLISH. Datasheet

Power Quality Analyzer Topas 2000

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Fluke Advanced Test Equipment Rentals ATEC (2832) Three-Phase Power Recorder

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Energy Management Energy Meter Type EM21 72R Retro-Fit

SOLAR300N Rel /01/10

Complimentary Reference Material

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

PQA823 PQA824 Rel /01/2007

Energy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.

PQA823 PQA824 Rel /03/2007

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Power analyzers and Energy Meters Power Analyzer Type WM14-96

DOBLE F6150SV TECHNICAL SPECIFICATIONS

Industrial Serie +600S

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

2-channel models. 4-channel models

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

Energy Management Energy Meter Type EM110

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

CMC 256plus - protection relay test set and universal calibrator

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

UMG 103-CBM. Universal measurement device for DIN rails

Vitrek 4700 Precision High Voltage Meter

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Digital Multifunction Instrument - Rish Master 3440

Technical Specifications for Portable 3-Ø Power Analyzer

LAUREL ELECTRONICS, INC.

Doc. EA Model Number:

Energy Management Energy Meter Type EM110

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Appendix A: Specifications

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

08/07/2015

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

Transcription:

PQube 3 s Reference conditions for factory tests: 19~25 C, 10%~70% RH MAINS VOLTAGE MEASURING CHANNELS Mains voltage channels Power configuration / Range of nominal input voltage 3 Line-to-Neutral, 3 Line-to-Line, 3 Line-to-Earth, 1 Neutral-to-Earth Single-phase - 69 VAC ~ 480 VAC (L-N) Split-single-phase 50 VAC ~ 480 VAC (L-N) and 100 VAC ~ 960 VAC (L-L) 3 phase wye/star - 50 VAC ~ 480 VAC (L-N) and 100 VAC ~ 830 VAC (L-L) 3 phase delta - 100 VAC ~ 600 VAC Power configuration and nominal voltages can be user-selected or auto-selected. Voltage measurement range 0 VAC ~ 750 VAC (L-N) and 0 VAC ~ 1300 VAC (L-L) Magnitude accuracy (±% rdg ±% FS) 100% Factory Test Pass/Fail limit ±0.01% ±0.025% ±0.05% 10VAC-750VAC L-N, 50/60 Hz. Voltage fundamental angle accuracy (relative to L1-E channel) 100% Factory Test Pass/Fail limit ±0.002 ±0.002 ±0.01 Sub-sample analog angle calibration Calibrated ±0.01 sample resolution 50/60 Hz. All specifications relative to L1-E angle, at nominal voltage, 50/60 Hz. and factory specifications are limited by system resolution. Range of nominal frequencies 16.67 Hz, Nominal 50 Hz, 60 Hz, or 400 Hz auto-selected Sampling Rate Notes 50/60 Hz 512 Samples per cycle Phase-locked to frequency on reference channel (L1-N or L1-L2) Simultaneous sampling on all voltage, current, analog and digital input channels Fully certified to IEC 61000-4-30 Class A Ed. 3 and Class 0.2 revenue meter accuracy Simultaneous sampling rates High- Frequency Impulse 4.0 MHz ±6 kv measurement range 4 MHz on L1-E channel only or 1 MHz on 4 channels (L1-E, L2-E, L3-E, N-E), user-selected Measured through 1.5 khz 2-pole high-pass filter Fully compatible with ANSI/IEEE C62.41, C3 and B3 combination wave, ring wave and IEC 61000-4-5 waveforms 2 khz-150 khz Emissions 1.0 MHz ±60 V measurement range, 12-bit min/avg/max recording 4 channels, 2 khz bins Filters per IEC 61000-4-30 Ed. 3 Frequency measurement range Input impedance 13.3 Hz ~ 23.3 Hz, 40 Hz ~ 70 Hz and 320 Hz ~ 560 Hz 4.8 MΩ 7.33 pf to Earth per phase Physical connection Wire connection L1, L2, L3, N, E pluggable screw terminal block (max torque 5 inch-pounds (0,6 Nm)) Minimum wire size 20 AWG (0,52 mm 2 ), maximum 14 AWG (2,1 mm 2 ) 600 V UL-recognized insulation required. Page 1 of 8

CURRENT INPUT CHANNELS Measurement channels 8 inputs : I1, I2, I3, I4, I5, I6, I7, I8 (typically used as L1, L2, L3, N, E, I6, I7, I8) Nominal input (Full scale) Crest factor 1A, 5A, 20A... 300A, 400A...6000A ranges available through CTs 3000A available through Flexible current sensors Nominal for the CT outputs: 0.333 Vrms (Low range) or 3.33 Vrms (High range) - user selected. 3.5 (±1.17 Vpk) (Low range) or 3.0 (±10 Vpk) (High range) Magnitude accuracy - including PSL Ultra-Precise calibrated shielded split-core current sensors (±% rdg ±% FS) Factory-generated CT calibration table: additional uncertainty ±0.05% ±0.035% ±0.1% At 50/60 Hz, 2.5% FS ~120% FS Additional uncertainty is the uncertainty due to the Factory CT Calibration System, plus uncertainty due to the resolution of the entries in the CT specific Calibration Table and the algorithms for applying the CT-specific Calibration Table. Angle accuracy - including PSL Ultra-Precise calibrated shielded split-core current sensors Factory-generated CT calibration table: additional uncertainty ±0.07 ±0.08 ±0.1 Sub-sample analog angle calibration Calibrated to ±0.01 sample resolution at 50/60 Hz. All channels calibrated relative to L1-E angle, 50/60 Hz. Magnitude accuracy excluding external CT's (±% rdg ±% FS) 100% Factory Test Pass/Fail limit ±0.01% ±0.025% ±0.05% At 50/60 Hz, 2.5% FS ~120% FS Angle accuracy - excluding external CT's 100% Factory Test Pass/Fail limit ±0.002 ±0.002 ±0.01 All specifications are relative to L1-E, at nominal voltage and current, 50/60 Hz. and factory specifications are limited by system resolution. Sampling rate Input impedance/burden Same rate as mains voltage measuring channels 33.3 kω < 1 VA for CTs CT ratio range 1:1 to 50000:1 Physical connection Interfaces with External CT (current transformer) with voltage-type secondary or Flexible current sensors 5 or 8 pairs of pluggable screw terminals (Max torque 2 inch-pounds (0,25 Nm)) Connections to feeder wires are done by clamping on split-core CTs around the feeder. Wire connection Connection of the CT voltage output to the PQube 3 input terminal: Min wire size 28 AWG (0,8 mm 2 ), Max. 16 AWG (1,31 mm 2 ). 600V UL- recognized insulation required. Page 2 of 8

ANALOG INPUT CHANNELS Measurement channels Nominal input (Full scale) Measurement range Accuracy Internal pull-up voltage User-selected Standard Mode or DC Energy Mode Standard mode: AN1-E, AN2-E, AN3-E, AN4-E (common mode), AN1-AN2, AN3-AN4 (differential mode) DC Energy mode: AN1 AN2, AN3 AN4 (bi-directional DC power), AN1 AN2 hours, AN3 AN4 hours (DC Energy) High range: ±60 VDC to Earth. Low range: ±10 VDC to Earth. High range: ±100 VDC, Low range ±10 VDC. ±0.05% rdg ±0.05% FS typical (1% ~ 100% FS), ANx-E 2.5 VDC Analog ratio range 1:1 to 10000:1 Input impedance Physical connection 1 MΩ to Earth Pluggable screw terminals (Max torque 2 inch-pounds (0,25 Nm)) AN1, AN2, AN3, AN4 and Earth DIGITAL INPUT CHANNEL Rating Wetting Digital threshold Sampling rate Input impedance Physical connection 3.3 VDC, 5 VDC, 24 VDC. Maximum input 60 VDC (differential input) 2.2 VDC typical. Can be used with NC or NO dry contacts. 1.5 V ±0.2V with 0.1 V hysteresis typical. Same rate as mains voltage measuring channels >1MΩ Pluggable screw terminals (Max torque 2 inch-pounds (0,25 Nm)) DIG1+ and DIG1- SIGNAL OUTPUT RELAY Connection Rating Function Operate time RLY1 pluggable screw terminals standard 30 VAC/30 VDC, 300 ma max When PQube 3 is off, normally open. When PQube 3 is on, normally closed. Contacts open for duration of event or 3 seconds (whichever is longer). 20 milliseconds POWER MEASUREMENTS Definitions Watts (power) Volt-Amps (apparent power) Power factor VARs (volt-amps reactive) Sum of true instantaneous per-phase bi-directional power, taken over the measurement interval. Sum of per-phase product of RMS voltage and RMS current, taken over the measurement interval. True power factor-ratio of Watts to Volt-Amps Fundamental VARs on L1, L2, L3 and total Inputs Voltages L-N, or L-Nm for delta configurations. Nm defined as measurement neutral, the instantaneous mean of the Page 3 of 8

three L-E voltages. Currents Measurement interval L1, L2, L3 Phase-locked, 10-cycles (50 Hz nominal) or 12-cycles (60 Hz nominal). Accuracy including PSL Ultra-Precise current sensors Watts (power) ±0.1% rdg typical at unity power factor, nominal voltage, 10% ~ 100% FS current. ±0.2% rdg typical at 0.5 power factor, nominal voltage, 10% ~ 100% FS current. Watt-hours (energy) Accuracy certified to ANSI C12.20 Class 0.2 and IEC 62053-22 Class 0,2S CLASS A POWER QUALITY MEASUREMENTS - IEC 61000-4-30 Ed. 3 Class A, full compliance certification Frequency Voltage amplitude Flicker Voltage dips/swells/interruptions Rapid voltage changes (rvc) Unbalance Voltage harmonics and interharmonics Mains signaling voltage Underdeviation and overdeviation Range 40 Hz ~ 70 Hz and 320 Hz ~ 560 Hz, Accuracy ±0.01 Hz, steady state Range 10% ~ 200% of nominal - Accuracy ±0.1% Udin (Udin = 120 V, 230 V) Method: True single-cycle RMS, phase-locked to each channel, updated every ½ cycle. URMS½ per IEC 61000-4-30 Class A. Also 10/12 cycle true-rms per IEC 61000-4-30 Class A. Pinst, Pst, Plt fully compliant and certified to IEC 61000-4-15 Ed. 2 Class F1 Fully compliant and certified to IEC 61000-4-30 Ed. 3 Class A, Accuracy ±0.2% of nominal voltage, duration accuracy : ±½ cycle at beginning of event and ±½ cycle at end of event, hysteresis selectable Fully compliant and certified to IEC 61000-4-30 Ed. 3 Class A - Accuracy 0.2% Fully compliant and certified to IEC 61000-4-30 Ed. 3 Class A Range 0.0% ~ 999.9%, method of symmetrical components, accuracy ±0.15% Fully compliant and certified to IEC 61000-4-30 Ed. 3 Class A Range 10% ~ 200% of Class 3 of IEC 61000-2-4 Accuracy : ±5% of reading for signals 1% of nominal, ±0.05% of nominal for signals < 1% nominal voltage Method IEC 61000-4-7 Class I, Gapless FFTs on L1-N, L2-N, L3-N, order up to 63 rd * Fully compliant and certified to IEC 61000-4-30 Ed. 3 Class A Range 0% ~ 15% of nominal voltage Accuracy ±5% of reading for signals between 3% ~ 15% of nominal, 0.15% of nominal for signals between 1% and 3% of nominal, no requirements for signals < 1% nominal User-selectable detection threshold recording period mains signaling frequency Fully compliant and certified to IEC 61000-4-30 Ed. 3 Class A Range 10% ~ 150% of nominal voltage, Accuracy ±0.1% of nominal voltage BEYOND CLASS A - 2 khz-150 khz CONDUCTED EMISSIONS MEASUREMENT Measurement method Range Fully compliant and certified to IEC 61000-4-30 Ed. 3, Annex C (informative) 200 Hz bin size for the range 2 khz-9 khz, 2000 Hz bin size for the range 9 khz-150 khz 0-60 Vpk Page 4 of 8

BEYOND CLASS A - HIGH FREQUENCY IMPULSE Sampling rate Accuracy Range Measurement 4 MHz on single channel, the channel is user selected. 1 MHz on 4 channels L1-E, L2-E, L3-E and N-E. ±5% typical. Dependent on frequency and type of impulse ±6 kvpk. User-selectable threshold through 2-pole 1.5 khz high-pass filter, and 1.5 MHz low pass filter Fully compatible with ANSI/IEEE C62.41, C3 and B3 combination wave, ring wave and IEC 61000-4-5 waveforms ENVIROSENSOR PROBES (TEMPERATURE/HUMIDITY/PRESSURE/ACCELERATION) Connection USB. Functional electrical isolation from PQube 3 Sampling rates Temperature Humidity Barometric pressure Acceleration 1 sample per second typical for temperature, humidity, barometric pressure 8, 16, 32 samples per second, user selected for acceleration Range: -20 C ~ +80 C (-4 F ~ 176 F) Range: 0 %RH ~ 100 %RH (useful range: 20 %RH ~ 80 %RH) Indicative measurements, resolution better than 0.001 hpa Full-scale acceleration ±2g, ±4g, ±8g, user selected Trigger on mechanical shock/vibration, seismic motion, or tilt OPTIONAL ATT1 VOLTAGE ATTENUATOR MODULES FOR ANALOG INPUT CHANNELS ATT1-0600V ATT1-1200V Rated full-scale voltage ±600 VDC/300 VAC to Earth ±1200 VDC/600 VAC to Earth Nominal measurement range ±825 Vpk to Earth ±1630 Vpk to Earth Test voltage to earth 7250 VDC 14500 VDC Accuracy ±0.2% reading typical at DC (>10% FS), plus uncertainty of PQube 3 analog input channels OPTIONAL ATT2 MODULE FOR DC POWER AND ENERGY Voltage channel ATT2-600V ATT2-1200V Maximum input voltage ±1000 Vpk differential ±2000 Vpk differential Rated full-scale voltage ±600 VDC/300 VAC differential ±1200 VDC/600 VAC differential Analog input ratio 100:1 200:1 Accuracy DC: ±0.1% rdg ±0.1% FS 50/60Hz: ±0.15% rdg ±0.15% FS typical (At 23 C ±3 C, 10% 100% FS, not including uncertainty of PQube 3 analog channels) Thermal drift of offset voltage Thermal drift of gain ±0.005 mv/ C typical ±0.01% rdg/ C typical Current channel With closed-loop sensors With open-loop sensors Page 5 of 8

Rated full-scale current Maximum input current 50A to 600A (depending on sensor model) 150% to 200% FS (depending on sensor model) 50A to 3000A (depending on sensor model) 110% to 200% FS (depending on sensor model) Accuracy at calibration current ±0.15% rdg ±0.15% FS typical at DC ±0.3% rdg ±0.3% FS typical at DC At 230C ±30C. Calibration current = 70% FS or 500A (whichever is smaller). Does not include uncertainty of PQube 3 analog channels Hysteresis offset voltage error < ±20 mv (after excursion of ±100% FS current) < ±30 mv (after excursion of ±100% FS current) Linearity (from 10% to 100% FS) ±0.1% rdg ±0.1% FS ±0.5% rdg ±0.5% FS Thermal drift of offset voltage ±0.1 mv/ºc typical ±1 mv/ºc typical Thermal drift of gain ±0.02% rdg/ºc typical ±0.1% rdg/ºc typical INSTRUMENT POWER SUPPLY PQube 3 power supply screw terminals supports AC or DC AC input range DC input range Power consumption Isolation PQube 3 P+ and P- pluggable screw terminals 24 VAC ±10% at 50/60/400 Hz, 1.5A max ±24 VDC ~ 48 VDC ±10% (polarity independent), 1A max 20W max Internally electrically isolated from all other circuits to avoid ground loops. PQube 3 - PoE - Power over Ethernet (standard) Input voltage range Power consumption 37 ~ 57 VDC 15W max PM1, PM2 Power Manager Modules (optional) Rated AC input range AC input current rating Supported DC input range Auxiliary DC power output Power consumption Isolation Surge immunity Installation category 100 ~ 240 VAC ±10%, 50/60 Hz 400 ma 120 ~ 370 VDC 24 VDC isolated, up to 5.15W max (Available with PM2 only) 20W max 3 kvac 1min, 4.2 kvdc 1 min EN 61000-4-5 Criteria A CAT II 300V Page 6 of 8

UPS1 BATTERY BACKUP MODULE PQube 3 backup time Battery Life expectancy 1 ~ 30 minutes, user selected. 7.4 V 2200mAh Li-ion battery pack 3 years or 500 cycles (100% depth discharges), whichever comes first. Operating temperature range 0 C ~ 45 C Operating humidity Protection 45 %RH ~ 85 %RH Built-in hardware cutoff for over-voltage, under-voltage, and overcurrent. UPS2 BATTERY BACKUP MODULE PQube 3 backup time Battery Life expectancy 1 ~ 60 minutes, user selected. 6.0 V, with one or several 2500mAh lead-acid external battery packs 10 years or 300 cycles (100% depth discharges), whichever comes first. Operating temperature range -20 C ~ 65 C Operating humidity Protection 45 %RH ~ 85 %RH Built-in hardware cutoff for over-voltage, under-voltage, and over-current. STORAGE/COMMUNICATIONS USB Connection Isolation Three USB master ports: one hi-speed USB2.0 port, two standard USB1.0 ports PQube 3 provides functional isolation to Earth (eliminates ground loops). Removable SD card Type Capacity microsd 8GB standard (stores up to 3 years of data under normal use) Ethernet Port Connection Email Web server Modbus over TCP FTP Server SNTP Standard RJ-45 socket (wired Ethernet). Transformer isolated. IP address can be assigned via DHCP or manually set fixed IP. Sends emails after every event with data attached; user request real-time meters via e-mail, PQube 3 firmware upgrade via email, change PQube 3 setup via email, incoming e-mail filters. Includes GIF graphs, CSV spreadsheet files, PQDIF, HTML and XML summaries Protocols: POP3, SMTP, and SSL over SMTP More than 30 real-time meters. All events, trends and statistics recordings. Includes GIF graphs, CSV spreadsheet files, PQDIF, HTML and XML summaries. More than 50 real-time meters with update rate of approximately 0.5 seconds - see PQube 3 Modbus document. Event/trend-statistics counters can be used for triggering downloads via FTP or web server. File Transfer Protocol. Transfers files from PQube 3 SD card to and from any computer. Simple Network Time Protocol for synchronizing PQube 3 real-time clock to UTC. Page 7 of 8

SNMP Security Support for SNMP v2c and v3 Secure FTP- FTPS, HTTPS. CLOCK TIMING Internal real-time clock SNTP NTP GPS (with optional MS1 module and GPS receiver) Fully compliant with IEC 61000-4-30 Ed. 3 Class A Drift: ±30 seconds/yr. Temperature compensated. ±70 seconds/yr. max drift Accuracy: ±10 to 100 milliseconds absolute, UTC time. Dependent on network latency. Accuracy: ±1 to 10milliseconds absolute, UTC time. Dependent on network latency Intrinsic resolution 1microsecond Accuracy better than Class A requirement (by a factor of 10) < 1ms. OPERATING ENVIRONMENT Operating temperature Operating humidity Altitude Overvoltage category Minimum -20 C, Maximum 65 C with no load on 24V power supply terminals, Maximum 55 C with 5.15W load on 24V power supply terminals 5% RH ~ 95% RH non-condensing, indoor use Maximum 2000 meters above sea level For PQube 3 AC mains measuring terminals, Overvoltage Category III 600V. For PM1 input terminals, Overvoltage Category II 300V. Pollution degree 2 Isolation Surge Installation category Transient voltages EFT burst immunity UL/IEC 61010:2010-3.6 kv AC 1 min, 5.1 kvdc 1 min, 5.4 kvac (5 sec), 9.6 kvpk impulse. UL/IEC 61010:2010-3.6 kv AC 1 min, 5.1 kvdc 1 min, 5.4 kvac (5 sec), 9.6 kvpk impulse. CAT IV UL/IEC 61010 for voltages up to 300 VAC L-N (equivalent to 480 VAC L-L), CAT III for voltages up to 600 VAC L-N. Pollution degree 2. 100 khz ring wave, 6 kvpk, IEC 61180, IEC 61000-4-5. Applied to voltage measuring terminals with Performance Evaluation Class 1. (When applied to optional power supply mains terminal, supply's fuse may operate in PE Class 3 at test levels greater than 4 kv.) 4 kvpk, IEC 61000-4-4, Performance Evaluation Class 1. Applied to power measuring terminals and optional PM1/PM2 power supply mains terminals. RF field strength immunity 3 V/m, IEC 61000-4-3 Test Level 2. Magnetic field strength immunity Ingress protection rating (IP rating) 30 A/m, IEC 61000-4-8 Test Level 4. IP20H, IEC 60529. (*) contact factory for availability Page 8 of 8