Characterizing a single photon detector

Similar documents
Photon Count. for Brainies.

PoS(PhotoDet 2012)058

InGaAs SPAD BIOMEDICAL APPLICATION INDUSTRIAL APPLICATION ASTRONOMY APPLICATION QUANTUM APPLICATION

INGAAS FAST PIN (RF) AMPLIFIED PHOTODETECTORS

InGaAs SPAD freerunning

Redefining Measurement ID101 OEM Visible Photon Counter

Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

A Measurement of the Photon Detection Efficiency of Silicon Photomultipliers

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

Silicon Carbide Solid-State Photomultiplier for UV Light Detection

Silicon Photomultiplier

pulsecheck The Modular Autocorrelator

Characterisation of SiPM Index :

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

IR Antibunching Measurements with id201 InGaAs Gated SPAD Detectors

Advantages of gated silicon single photon detectors

ADVANTAGES OF SILICON PHOTON COUNTERS IN GATED MODE APPLICATION NOTE

PRELIMINARY. Specifications are at array temperature of -30 C and package ambient temperature of 23 C All values are typical

InGaAs Avalanche Photodiode. IAG-Series

TCSPC at Wavelengths from 900 nm to 1700 nm

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

High-performance InGaAs/InP-based single photon avalanche diode with reduced afterpulsing

Photon Counters SR430 5 ns multichannel scaler/averager

PCS-150 / PCI-200 High Speed Boxcar Modules

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

Application Notes: Discrete Amplification Photon Detector 5x5 Array Including Pre- Amplifiers Board

Pulses in Fibers. Advanced Lab Course. University of Bern Institute of Applied Physics Biomedical Photonics

Instruction manual and data sheet ipca h

SiPMs for solar neutrino detector? J. Kaspar, 6/10/14

Effects of Incident Optical Power on the Effective Reverse Bias Voltage of Photodiodes This Lab Fact demonstrates how the effective reverse bias

Figure Responsivity (A/W) Figure E E-09.

Quantifying the energy of Terahertz fields using Electro-Optical Sampling. Tom George. LCLS, Science Undergraduate Laboratory Internship Program

OFCS OPTICAL DETECTORS 11/9/2014 LECTURES 1

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

Contents. The AMADEUS experiment at the DAFNE collider. The AMADEUS trigger. SiPM characterization and lab tests

Uniformity and Crosstalk in MultiAnode Photomultiplier Tubes

Silicon Photo Multiplier SiPM. Lecture 13

Silicon Photomultiplier Evaluation Kit. Quick Start Guide. Eval Kit SiPM. KETEK GmbH. Hofer Str Munich Germany.

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Xiuliang Chen, E Wu, Guang Wu, and Heping Zeng*

ModBox - Spectral Broadening Unit

Amplified High Speed Photodetectors

Detectors for microscopy - CCDs, APDs and PMTs. Antonia Göhler. Nov 2014

Extending the Offset Frequency Range of the D2-135 Offset Phase Lock Servo by Indirect Locking

Figure Figure E E-09. Dark Current (A) 1.

Photodiode: LECTURE-5

Engineering Medical Optics BME136/251 Winter 2018

14-MHz rate photon counting with room temperature InGaAs / InP avalanche photodiodes

Non-amplified Photodetectors

S.M. Vaezi-Nejad, M. Cox, J. N. Copner

Silicon Avalanche Photodiode SAR-/SARP-Series

TCSPC measurements with the InGaAs/InP Single- photon counter

Non-amplified High Speed Photodetectors

SHM-180 Eight Channel Sample & Hold Module

Status of Primex Beam Position Monitor July 29 th, 2010

Amplified Photodetectors

PoS(PhotoDet 2012)051

Great Britain: LASER COMPONENTS (UK) Ltd., Phone: , Fax: , France: LASER COMPONENTS

APE Autocorrelator Product Family

Lecture 9 External Modulators and Detectors

Optical Fiber Amplifiers. Scott Freese. Physics May 2008

Chemistry Instrumental Analysis Lecture 10. Chem 4631

Waveguide-based single-pixel up-conversion infrared spectrometer

Table of Contents Table 1. Electrical Characteristics 3 Optical Characteristics 4 Maximum Ratings, Absolute-Maximum Values (All Types) 4 - TC

14 MHz rate photon counting with room temperature InGaAs/InP avalanche photodiodes

CHAPTER 8 PHOTOMULTIPLIER TUBE MODULES

Exp 3 COLCULATE THE RESPONSE TIME FOR THE SILICON DETECTOR

Photonics and Optical Communication Spring 2005

SUPPLEMENTARY INFORMATION

GFT1504 4/8/10 channel Delay Generator

Avalanche Photodiode. Instructor: Prof. Dietmar Knipp Presentation by Peter Egyinam. 4/19/2005 Photonics and Optical communicaton

Characterization of a prototype matrix of Silicon PhotoMultipliers (SiPM s)

Deschutes Series InGaAs Avalanche Photodiodes

arxiv: v2 [physics.ins-det] 17 Oct 2015

2014 PRODUCT SELECTION GUIDE

400 MHz Photoreceiver with Si PIN Photodiode

March 31, 2003 Single-photon Detection at 1.55 µm with InGaAs APDs and via Frequency Upconversion Marius A. Albota and Franco N.C.

Components of Optical Instruments

NIH Public Access Author Manuscript Opt Lett. Author manuscript; available in PMC 2012 March 14.

125-MHz Photoreceivers Models 1801 and 1811

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application

A-CUBE-Series High Sensitivity APD Detector Modules

PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS

DC to 3.5-GHz Amplified Photoreceivers Models 1591 & 1592

New Focus High Speed Photoreceivers

ECEN 4606, UNDERGRADUATE OPTICS LAB

Status of the LED calibration system

Electronic Instrumentation. Experiment 8: Diodes (continued) Project 4: Optical Communications Link

Wavelength switching using multicavity semiconductor laser diodes

Optical Receivers Theory and Operation

Solid-State Photomultiplier in CMOS Technology for Gamma-Ray Detection and Imaging Applications

Working in Visible NHMFL

GPD. Germanium Photodetectors. GPD Optoelectronics Corp. OPTOELECTRONICS CORP. Small & Large Area pn, pin detectors Two-color detectors

Optical Power Meter Basics

Review of tradeoffs for quenched avalanche photodiode sensors for imaging turbid media

Optical to Electrical Converter

1550 nm Programmable Picosecond Laser, PM

H2 / H3 / H4 / H5 Series Silicon and InGaAs-APD Receiver

Testing the Electronics for the MicroBooNE Light Collection System

Transcription:

Michigan Technological University Digital Commons @ Michigan Tech Dissertations, Master's Theses and Master's Reports - Open Dissertations, Master's Theses and Master's Reports 2011 Characterizing a single photon detector Paul N. Rojas Michigan Technological University Copyright 2011 Paul N. Rojas Recommended Citation Rojas, Paul N., "Characterizing a single photon detector", Master's report, Michigan Technological University, 2011. http://digitalcommons.mtu.edu/etds/566 Follow this and additional works at: http://digitalcommons.mtu.edu/etds Part of the Physics Commons

CHARACTERIZING A SINGLE PHOTON DETECTOR By Paul N. Rojas A REPORT Submitted in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE PHYSICS MICHIGAN TECHNOLOGICAL UNIVERSITY 2011 2011 Paul Rojas

Characterizing a Single Photon Detector Paul Rojas Advisor: Dr. Kim Fook Lee Abstract I will present my work about constructing and characterizing a single photon detector. Using the 1550nm laser and second harmonic light generation, I am able to count single photons on a Multi Pixel Photon Counter (MPPC) silicon APD. My results show that upwards of 22% quantum efficiency is achievable with the MPPC. Future work will include coincidence detection of correlated photon pair. 1. Introduction 1.1 Motivation Quantum information is a big and growing field. One of the many topics includes quantum communication. Quantum communication utilizes photons as bits and by counting individual photons we take one step closer to realizing this goal. The wavelengths used in this experiment are also useful because they are in the telecom band. Another possible use is high resolution spectroscopy. With high resolution spectroscopy, individual photon resolution allows for more detailed spectrums, allowing for better characterization of elements. 1.2 The Avalanche Photodiode The most important part of the experiment is the avalanche photodiode (APD). By use of an APD, which amplifies the effect of the photon, one can record measurements. An incident photon strikes an electron on the surface of the APD, with a large bias voltage greater than the breakdown voltage of the material, the electron speeds through the material, knocking more electrons thus creating the avalanche. We use a power supply to create a bias voltage almost at the breakdown level, and then use a pulser with a voltage large enough such that the total voltage is above the breakdown voltage. There are two kinds of counts one can get from an APD, dark counts and light counts. Dark counts are when one sees the breakdown with no laser light. Light counts are counts from the APD while laser light is present. 1

Downcounter Pulser Laser Avalanche Photodiode Photon Counter Second Harmonic Figure 1. Diagram of Setup 2. Components and Apparatus 2.1 Laser We use a 50MHz, 50mW, 150fs pulse width, 1550nm Polar Onyx laser for this operation. It is split into two beams, one at 49mW and another at 1mW. The 1mW beam is used as the trigger for the experiment; this beam goes to the downcounter. Unfortunately, 50MHz is too fast for our delay generator, which has a limit of 1MHz, so we ve slowed it down to 780kHz. The 49mW component is sent to the second harmonic light generation setup which allows us to halve the wavelength. This is necessary since our APD won t operate at an optical wavelength of 1550nm, however, 775nm is within the APD s operating limits. 2.2 Downcounter The downcounter inputs the laser and slows it down to 1/64 th of what its original frequency was. We must slow it down as the original 50MHz is too fast for our delay generator. The downcount is achieved by use of 4 components: the photodiode, an amplifier, a comparator, and a downcouter chip. The photodiode translates the optical signal into a digital signal, allowing us to use electrical components. Next, the electronic signal is sent to an amplifier, this brings the peak to peak voltage level of the signal into operating range of the comparator. Following the amplifier the signal goes to the comparator and is compared to a tunable resistor, resulting in a square wave. The square wave then goes to the downcounter chip and is downcounted by 64. With an input frequency of 50MHz this results in a downcounted output frequency of 780kHz. 2

Figure 2. Diagram of the function of the downcounter circuit (See appendix A for full electronic diagram). First the photodiode takes the incident light and creates a signal. That signal goes to the amplifier, creating a gain. The comparator compares the signal with a resistor resulting in a square wave. This goes to the downcounter which slows the signal. 2.3 Delay Generator Using the output from the downcounter we trigger the delay generator, an SRS DG535. The main function of the delay generator is to create multiple outputs that are synced up so our signals arrive at expected times. The delay generator is also able to create variable delays in its outputs. The maximum delay time for a signal is 1/f 1µs, where f is the frequency. This places a maximum frequency of the device at 1MHz. We output two TTL pulses, one to trigger our pulser and another to trigger our photon counter. 2.4 Pulser Our pulse generator is an Avtec AVM 2 C. We can get pulses from 600mV to 15V with widths of 500ps to 1.5ns. The pulser was 1.5ns wide and 600mV high. It is important for us to be able to use small pulse widths because this means the APD will be above the breakdown voltage for a shorter amount of time resulting in less dark counts. Dark counts are counts made by the equipment when there is no laser light present. 2.5 APD The APD we are calibrating is a silicon Multi Pixel Photon Counter (MPPC) from Hamamatsu. It operates in a spectrum of laser light from 500nm to 900nm and has a breakdown voltage of 71.59 volts. The APD gets a bias voltage of 71V from an Agilent power supply and gated voltage of 600mV from the pulser, which results in a total voltage of 71.6V, just above the breakdown voltage. The MPPC has a surface of pixels, this is where the incident laser light that is counted strikes. The signal from the MPPC is then sent to Input 1 on the photon counter for discriminated counting. 3

Figure 3. The left graph is shows a peak from our pulser. The right graph shows our breakdown signal outputted from our MPPC. Note that the signal becomes sketchy resulting from dark counts. The red overlay signifies what our discriminator from the photon counter might look compared to the signal. 2.6 Second harmonic light generation Second harmonic light generation is a non linear optical property of certain materials. Essentially, by sending a laser to a special kind of crystal, two photons will enter, but one will leave. This results in a doubling of energy thus a doubling of frequency and a halving of wavelength. This is necessary for our experiment because our MPPC APD operates at 775nm, which is approximately half of our 1550nm wavelength from our laser. For the second harmonic light generation in this experiment, we used a Type I BBO crystal with a maximum efficiency of ~2%. To filter out the 1550nm wavelength we used a broca prism. The broca prism has an index of refraction dependant on frequency which splits the laser light into 1550nm and 775nm beams. We block the 1550nm light and couple the 775nm light to a fiber optic cable. We were able to get a maximum power of.9mw from the 775nm light, which is just under the 2% maximum efficiency,.98mw Because we are characterizing the system, we must send a single photon per pulse of laser light to the APD. We achieve this by attenuating the light. By using the following equation: P=R*h*c/λ, where R is the repetition rate of the laser, h is Planck s constant, c is the speed of light, and λ is the wavelength of laser light, we calculate a power of 79dBm. Once the laser was attenuated to the proper power, we send that laser light to the APD. 2.7 Photon Counter The photon counter we use is the SRS400. The counter accepts the TTL pulse from the delay generator. This machine runs for a specified number of gates, adjustable by the user, and marks a count whenever the input signal jumps above the discriminator level. The machine also gates our signal, thus allowing us to use only the biggest peak, where the breakdown is most significant. 2.8 Problems We encountered multiple problems while building and running this experiment. Our first APD broke so we had to replace it with a cheaper APD. We also had issues with grounding, where getting physically 4

close to wires and certain components caused our data to change. We also encountered a problem where our signal would drift on the photon counter, thus requiring us to constantly change the discriminator level to match where the new maximum would be. Initially we used a Princeton Lightwave APD (PGA 400), with a pigtail coupling for light. This broke under use and we had to switch to the Hamamatsu APD, a cheaper, lower quality APD. We used the MPPC to test the circuit and find out what fried the PGA 400. The day it died there was a thunderstorm which could have created a power surge in the Agilent power supply and brought the total bias voltage too high for the APD. We don t believe this is case though due to the high quality of Agilent s power supplies, but it is still a possible factor though. Another problem we noticed was with our APD circuit, we had a dead capacitor. With a dead capacitor more DC voltage could have gotten to the APD thus killing it. However, we believe the main cause of the failure to be a short in the board. Due to using surface mount components and a small board its possible some solder created a bridge and allowed more voltage than necessary. To fix the board we re soldered the whole thing, once again taking care to how we soldered, and replaced the dead capacitor. Replacing the dead capacitor fixed our drifting problem and we remained with a constant steady signal. To fix our grounding issues we placed the APD into a metal box which relieved most of the sensitivity of the equipment. 3. Results and Analysis To characterize the APD we recorded the number of counts per 10k gates. We checked to see how counts were affected by discriminator levels and bias voltages. Starting at the 17.8 mv level for our discriminator and decreasing.2mv each trial until 17.2mV since at that level there was an incredibly high dark count. To check the effect of bias voltage, we raised the total voltage to 71.8V in.1v increments from 71.6V. For our errors we used the standard deviation for a Poisson system, σ=(n).5. (a) (b) (c) We took our measurements without light to get our dark count graphs. To get the light + dark count graph we took measurements with laser light incident to the APD. To find out the number of light counts though, one must subtract the dark counts from the light dark counts. Our results here are expected and make sense. By decreasing the discriminator level we increase the number of count. This is correct because as we lower the discriminator we lessen the requirement of energy needed to mark 5

as a count. Also to note, for the light counts we see increasing counts as the bias voltage is raised. Once again, we expect this, because a greater bias voltage creates a greater avalanche effect on the diode making a bigger signal. On graph (c) the 71.2V graph doesn t increase as much as one would expect compared to the lower bias voltages. This is because at a low discriminator level we have a high number of dark counts. In an attempt to lower our error and bring our gates into a larger time domain, we combined our counts from the 10k gates and created data for 40k gates. For 40k gates we see the same trends as before. (d) (e) (f) To characterize our MPPC silicon APD, we look at how quantum efficiency relates to the dark count probability and discrimination level. The dark count probability is simply the number of dark counts divided by the number of gates. For our experiment, we used one photon per pulse. This means our quantum efficiency is defined as: QE= number of light counts/number of gates In this case we use one photon per pulse; this means our efficiency is equal to the light count probability. (g) (h) 6

This shows our MPPC APD is able to achieve upwards of 22%. However, due to the quality of the MPPC we have a high dark count probability. In graph (h) the efficiency increases as the discriminator is decreased due to increased light count probability. 4. Future Work We are confident that our experiment works. Next, we must replace the Hamamatsu MPPC with our Princeton Lightwave APD and confirm that our setup still works it. By replacing it with an InGaAs APD we should keep the same efficiency but have a lower dark count probability, resulting in a better detector. Also, by using the InGaAs APD we will be able to get rid of the second harmonic light generation component because the InGaAs operates at 1550nm wavelengths. After we characterize our Princeton Lightwave InGaAs APD we will build a second APD circuit with the same type of APD in it and begin correlated photon counting. The SRS400 Photon Counter has two inputs, allowing us to use two InGaAs APDs. We can then output the counts to our SR430 Multichannel Scaler and Averager; this will allow for coincidence counting. 7

References: 14Mhz rate photon counting with room temperature InGaAs/InP avalanche photodiodes. Paul Voss et. al. Journal of Modern Optics. July 15 Vol. 51, n.9, 1369 1379. A Single Photon Detector for High Speed Telecom Band Quantum Communication Applications. Chuang Liang et. al. Quantum Communications and Quantum Imaging III, Proc. of SPIE Vol. 5893. pg. 14 1 to 14 6 8

Appendix The electronic schematic for our downcounter circuit. 4990Ω ~1mW 50Ω 9V 1 OPA846 +5V 1 AD8611 330Ω 330Ω 100Ω -5V 50Ω 3V 16 50Ω OUTPUT 9

Electronic diagram for APD board. Bias Voltage (SMA) 320μH 25Ω 50Ω APD APD Cathode APD Anode Case GND. 50Ω Gate In (SMA) Output (SMA) 10