Radio Remote Controls Manual K Series

Similar documents
Radio Remote Controls Manual K Series

Radio Controls Manual Protean Series

Radio Control Manual Series L10

Radio Remote Controls Manual Series L12

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Radio Remote Controls Series D1 / D2

Radio Remote Controls Protean TM L Series K Series

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

X80 Activator. User's Manual. Version 1.1.

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

Single Flex and Double Flex Couplings (i)

Radio Remote Controls Protean TM L Series K Series

Radio Remote(s) (Installation Manual)

Using the USB Output Port to Charge a Device

User s Guide ASSISTIVE LISTENING SYSTEMS

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Gypsy Statement of Limited Warranty. Part 1 General Terms

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

380 SERIES REPAIR PARTS INDEX. NOTE! Read and understand the pump and motor instructions before attempting to install, disassemble or repair the pump.

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

Keychain Radio Remote Control System

14 Piece Slide Hammer and Puller Set

RFTX-1 Installation Manual

Installation/Operation Instructions and Warranty Information for Models...

PHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S

Glass Electrode Meter

Owner s Manual & Safety Instructions

Model DB Disc Caliper Brake AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

BE369 Deadbolt Installation Instructions

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

MaxLite LED Self-Driven LiteBars

MODEL 3810/2 Line Impedance Stabilization Network

COMMERCIAL TRANSMITTER INSTRUCTIONS

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

PCO-7114 Laser Diode Driver Module Operation Manual

Tension Control Clutch Model TCC-7

Technical Support, End User License & Warranty Information

WARNING: Do not work around outlets while the power is on. Do not stick fingers or tools into an electrical box while the power is on.

Model 9302 Amplifier-Discriminator Operating and Service Manual

Model 113 Scintillation Preamplifier Operating and Service Manual

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

Owner s Manual & Safety Instructions

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

SureCall TM CM dB Dual Band Universal Inbuilding Repeater

SureCall TM CM800 65dB

Questions? Call Toll-Free

Grid Radar Installation Manual

A-16D A-Net Distributor

User Manual January Opticom Infrared System RC790 Remote Coding Unit

Receiver Type /Version Factory No. Frequency. Transmitter Type /Version Factory No. Frequency

Pushbutton Bollard. Wireless Control for BlinkerSign, RRFB or BlinkerBeacon User Guide. Blinker Division Solar LED Solutions

CDT. Service and Installation Manual. Manual Revision Oct 2014

INSTRUCTION MANUAL INF Fax: (503)

TERMS OF SALE. Quotations & Orders

LBI Mobile Communications MDX DESK TOP STATION. Operator's Manual

Installation Instructions

CSM_G7S-_-E_DS_E_7_1

Installation Instructions

Broadband Current Probe Series Operation Manual

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

742A Series Resistance Standards

E3X-DRT21/SRT21/CIF11

Pre-Filter. Brushless/ Sparkless Blower. HEPA Filter. Fluorescent Light

Instruction Sheet D-CPU. Secure CPU Holder

TeleChief Series TM2200HT

Horizontal Mezzanine Gate

Instruction Sheet SNE SERIES. Cable Chase

User s Guide Instructions for Installation and Operation

Preliminary Data Sheet!

LBI-38976A. Mobile Communications MDX/ORION DESK TOP STATION. Operator's Manual

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

RTC. Redundant Transmitter Controller FM RTC. Redundant Transmitter Controller. User's Manual

CRD 410 MANUAL FITTING INSERTER

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Independent Technology Service Inc Independence Ave. Chatsworth, California Toll Free:

SPM-50 RF Spectrum Power Meter PC Software User Manual

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Planishing hammer stand For use with SKU Planishing hammer

WSA 8 BOX RELE Installation Manual

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

UNCONTROLLED WHEN PRINTED

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Oberebenestrasse Bremgarten Switzerland Tel Fax

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

Current Probe Fixture Instruction Manual

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003

VT1586A Rack Mount Terminal Panel Installation and User s Manual

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

Field Hub Installation Guide. P/N Rev. C 05/15

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

SIR-WRR1. User's Guide SIRIUS Echo Antenna. Signal Repeater System Accessory

Manual Carton Closing Staplers

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

8003 1/8 DIN Temperature Controller

Installation Guide. Delphi XM FM Direct Accessory. For Use With Roady2 and SKYFi2 Satellite Radio Receivers

SX204. Headphone Amplifier. Symetrix. Owner s Manual

Transcription:

Radio Remote Controls Manual K Series 1 PN 52764 2010.12.20 Rev. 2 K SERIES RADIO CONTROL MANUAL

Conductix Incorporated The technical data and images which appear in this manual are for informational purposes only. NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE CREATED BY THE DESCRIPTIONS AND DEPICTIONS OF THE PRODUCTS SHOWN IN THIS MANUAL. Conductix makes no warranty (and assumes no liability) as to function of equipment or operation of systems built according to customer design or of the ability of any of its products to interface, operate or function with any portions of customer systems not provided by Conductix. Seller agrees to repair or exchange the goods sold hereunder necessitated by reason of defective workmanship and material discovered and reported to Seller within one year after shipment of such goods to Buyer. Except where the nature of the defect is such that it is appropriate, in Seller s judgment, to effect repairs on site, Seller s obligation hereunder to remedy defects shall be limited to repairing or replacing (at Seller s option) FOB point of original shipment by Seller, any part returned to Seller at the risk and cost of Buyer. Defective parts replaced by Seller shall become the property of Seller. Seller shall only be obligated to make such repair or replacement if the goods have been used by Buyer only in service recommended by Seller and altered only as authorized by Seller. Seller is not responsible for defects which arise from improper installation, neglect, or improper use or from normal wear and tear. Additionally, Seller s obligation shall be limited by the manufacturer s warranty (and is not further warranted by Seller) for all parts procured from others according to published data, specifications or performance information not designed by or for Seller. Seller further agrees to replace or at Seller s option to provide a refund of the sales price of any goods that do not conform to applicable specifications or which differ from that agreed to be supplied which non-conformity is discovered and forthwith reported to Seller within thirty (30) days after shipment to the Buyer. Seller s obligation to replace or refund the purchase price for non-conforming goods shall arise once Buyer returns such goods FOB point of original shipment by Seller at the risk and cost of Buyer. Goods replaced by Seller shall become the property of Seller. There is no guarantee or warranty as to anything made or sold by Seller, or any services performed, except as to title and freedom from encumbrances and, except as herein expressly stated and particularly, and without limiting the foregoing, there is no guarantee or warranty, express or implied, of merchantability or of fitness for any particular purpose or against claim of infringement or the like. Seller makes no warranty (and assumes no liability) as to function of equipment or operation of systems built to Buyer s design or of the ability of any goods to interface, operate or function with any portions of Buyer s system not provided by Seller. Seller s liability on any claim, whether in contract, tort (including negligence), or otherwise, for any loss or damage arising out of, connected with, or resulting from the manufacture, sale, delivery, resale, repair, replacement or use of any products or services shall in no case exceed the price paid for the product or services or any part thereof which give rise to the claim. In no event shall Seller be liable for consequential, special, incidental or other damages, nor shall Seller be liable in respect of personal injury or damage to property not the subject matter hereof unless attributable to gross misconduct of Seller, which shall mean an act or omission by Seller demonstrating reckless disregard of the foreseeable consequences thereof. Seller is not responsible for incorrect choice of models or where products are used in excess of their rated and recommended capacities and design functions or under abnormal conditions. Seller assumes no liability for loss of time, damage or injuries to property or persons resulting from the use of Seller s products. Buyer shall hold Seller harmless from all liability, claims, suits and expenses in connection with loss or damage resulting from operation of products or utilization of services, respectively, of Seller and shall defend any suit or action which might arise there from in Buyer s name - provided that Seller shall have the right to elect to defend any such suit or action for the account of Buyer. The foregoing shall be the exclusive remedies of the Buyer and all persons and entitles claiming through the Buyer. 2 K SERIES RADIO CONTROL MANUAL PN 52764 2010.12.20 Rev. 2

INDEX 1.0 Warning and Caution 2.0 Important Information Before You Start 2.1 Important 2.2 Precautions 2.3 Emergency Procedures 3.0 Specification 4.0 Transmitter & Receiver Overview 5.0 General Operation 5.1 Getting Started 5.2 Transmitter LED Indicator 5.3 Changing Receiver Input Voltage 6.0 Receiver Wiring Diagram 3 PN 52764 2010.12.20 Rev. 2 K SERIES RADIO CONTROL MANUAL

1.0 Warning and Caution The following symbols may be found on the product or throughout the documentation. Symbol Description Refer to Manual Refer the user manual for additional information when product marked with this sign. Dangerous Voltage Indicated presence of hazardous voltage. Unsafe practice could result in sever personal injury. Warning Denotes a hazard. Included text gives proper procedures. Failure to follow instructions could result in severe personal injury and/or property damage. Caution Denotes a hazard. Included text gives proper procedures. Failure to follow instructions could result in minor personal injury and/or property damage. 4 K SERIES RADIO CONTROL MANUAL PN 52764 2010.12.20 Rev. 2

2.1 Important 2.0 Important Information Before You Start Due to the complex nature of equipment, read this entire manual carefully before operation and installation. 2.1.1 Never allow any unauthorized personnel to dismantle equipment as this may cause the equipment damage. 2.1.2 The equipment has been stringently tested for quality assurance before delivery from factory. However, it must not be used in extremely dangerous situations, or where damage may result. 2.1.3 After operation, switch off crane main power as well as receiver unit and remove rotary key from transmitter unit. 2.1.4 The transmitter should be kept in a safe place when not in use to avoid any unintentional operation. 2.1.5 The crane should be equipped with main power relay, limit switch and the other safety devices required. 2.1.6 Do not use this device during electrical storms or where there are conditions of high electrical interference. 2.1.7 Always check transmitter battery and receiver input power conditions before operation. 2.1.8 The installation and maintenance service is allowed only when the crane and receiver power are turned off to avoid electrical shock. 2.1.9 The contents of the manual may be amended by the manufacturer without notice. 2.1.10 The specification and function is subjected to change without notice by manufacturer. 2.2 Precautions 2.2.1 Press EMS button and switch off main power of crane and receiver after operation. Then remove transmitter rotary key and keep in a safe place. 2.2.2 The following situations may cause receiver response delay and stop operation immediately when situation occurs. a) Beyond operation range b) During sever radio interference 2.2.3 Remove transmitter batteries when not in use for a long period of time. 2.2.4 To extend product life, please follow the standard operation procedure and maintain system regularly. 2.2.5 Check EMS button and other main functions before operation. 2.2.6 Press EMS button during system failure or any abnormal conditions occur. 2.2.7 The operator must be familiar with emergency procedures before operating the system. 2.3 Emergency Procedures In case of emergency, please follow the procedure below: 2.3.1 Press EMS button and stop operation. 2.3.2 Switch rotary key to OFF position and remove it from transmitter unit. 2.3.3 Switch off crane main power. 2.3.4 Contact the authorized distributor for further assistance. 5 PN 52764 2010.12.20 Rev. 2 K SERIES RADIO CONTROL MANUAL

3.0 Specification General Specification ID Code Channel Space Hamming Distance Structure Operation Environment Operating Distance Over 1 Million Sets 25 KHz 4 Enhanced Glass-Fiber -40 C ~ +85 C Up to 100 M Transmitter Power AA Battery x 4 Emission Power Dimension Weight Receiver < 10mW 163x49x45mm (Series K1/K2) 274x77x42mm (Series K3/ K4) 210 g (Series K1/K2) 385 g (Series K2/K3) Power 24/48/110/220/380VAC (± 20%) Dimension Weight 167x154x88mm (Series K1/K2) 310x160x95mm (Series K2/K3) 2100g (Series K1/K2 with cable) 2900g (Series K2/K3 with cable) 6 K SERIES RADIO CONTROL MANUAL PN 52764 2010.12.20 Rev. 2

Series K1/K2 Transmitter Overview 4.0 Transmitter & Receiver Overview EMS Button Function Button Rotary Key LED Indicator START / Alarm Button Battery Cover Series K1/K2 Receiver Overview Alarm (Horn) Receiver Wiring Diagram Cable Power - On Indicator Antenna 7 PN 52764 2010.12.20 Rev. 2 K SERIES RADIO CONTROL MANUAL

Series K3/K4 Transmitter Overview 4.0 Transmitter & Receiver Overview 1 3 5 EMS Button Function Button & A/B Switch Battery Cover 2 LED Indicator 4 START / Alarm Button 6 Rotary Key Series K3/K4 Receiver Overview Antenna Power-On Indicator Alarm (Horn) Receiver Wiring Diagram Cable 8 K SERIES RADIO CONTROL MANUAL PN 52764 2010.12.20 Rev. 2

5.1 Getting Started 5.0 General Operation 5.1.1 Install 4 new AA-size batteries in the battery compartment (make sure batteries correctly installed according to the indication of Postive & Negative ) and close battery cover firmly. 5.1.2 Insert rotary key into transmitter unit and switch to ON position. 5.1.3 Press START button to power the system. Note: Red LED indicator will flash when fail to follow procedures above accordingly. 5.1.4 Press function button for operation. 5.1.5 Follow the procedure below when finished with operation. 1. Press EMS button. 2. Switch rotary key to OFF position. 3. Remove rotary key and keep in a safe place. 4. Remove batteries if not to be used for long period of time. 5.2 Transmitter LED Indicator Green (Full Power) Operate as usual. Yellow (Mid Power) Red (Low Power) Unload the article as soon as possible and stop operation until batteries are replaced. An EMS signal will be sent to receiver automatically to turn off receiver. To avoid the interruption during operation, check battery power frequently. Note: Switch rotary key to OFF position to turn off transmitter completely thus extending the battery life, otherwise transmitter is in standby mode when rotary key remains in the ON position. 5.3 Changing Receiver Input Voltage If the factory preset receiver voltage is different from application, follow the procedures below to change input voltage. (Three different voltage options for each receiver as shown in the picture with yellow label.) 5.3.1 Switch off receiver main power. 5.3.2 Remove the connector from original position. 5.3.3 Insert connector to new voltage position accordingly. Note: Four different transformer options are available for K Series. (1) 24V/42V/230V (2) 48V/110V/220V (3) 110V/220V/380V (4) 48V/220V/380V 9 PN 52764 2010.12.20 Rev. 2 K SERIES RADIO CONTROL MANUAL

6.0 Receiver Wiring Diagram K1 Series K1 Series (DC) K2 Series K2 Series (DC) 10 K SERIES RADIO CONTROL MANUAL PN 52764 2010.12.20 Rev. 2

6.0 Receiver Wiring Diagram K3 Series K3 Series (DC) K4 Series K4 Series (DC) 11 PN 52764 2010.12.20 Rev. 2 K SERIES RADIO CONTROL MANUAL

www.conductix.us Conductix-Wampfler 2017 Subject to Technical Modifications Without Prior Notice USA / LATIN AMERICA 10102 F Street Omaha, NE 68127 Customer Support Phone +1-800-521-4888 Phone +1-402-339-9300 Fax +1-402-339-9627 info.us@conductix.com latinamerica@conductix.com CANADA 1435 Norjohn Court Unit 5 Burlington, ON L7L 0E6 Customer Support Phone +1-800-667-2487 Phone +1-450-565-9900 Fax +1-450-851-8591 info.ca@conductix.com MÉXICO Calle Treviño 983-C Zona Centro Apodaca, NL México 66600 Customer Support Phone (+52 81) 1090 9519 (+52 81) 1090 9025 (+52 81) 1090 9013 Fax (+52 81) 1090 9014 info.mx@conductix.com BRAZIL Rua Luiz Pionti, 110 Vila Progresso Itu, São Paulo, Brasil CEP: 13313-534 Customer Support Phone (+55 11) 4813 7330 Fax (+55 11) 4813 7357 info.br@conductix.com Contact us for our Global Sales Offices 12 K SERIES RADIO CONTROL MANUAL PN 52764 2010.12.20 Rev. 2