OPTISENS PH 8390 Technical Datasheet

Similar documents
OPTISENS ORP 8590 Technical Datasheet

OPTISENS PH 8100 Technical Datasheet

OPTISENS PH ph sensor. Technical Datasheet

SMARTPAT PH 1590 Technical Datasheet

Digital ORP sensor for the water and wastewater industry

SMARTPAT COND 1200 Technical Datasheet

OPTISENS CL 1100 Technical Datasheet

SMARTPAT ORP 8510 Technical Datasheet

OPTISENS PH 8500 Handbook

Digital ORP sensor for the industrial wastewater industry

SMARTPAT ORP 8150 Technical Datasheet

OPTISYS CL 1100 Technical Datasheet

ph or ORP Transmitter

OPTITEMP TT 20 Technical Datasheet

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

WATERFLUX 3000 Quick Start

Orbipac CPF81/CPF82 and CPF81D/CPF82D

WATERFLUX 3000 Quick Start

Technical Information Orbipore CPS91D and CPS91

Signet ph/orp Electrodes General Purpose

OPTIFLUX 5000 Technical Datasheet

Memosens CPS96D. Technical Information

Signet ph/orp Electrodes

phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

Condumax W CLS15 and CLS15D

Signal converter for electromagnetic flowmeters

TUpH 396RVP and 398RVP Retractable ph/orp Sensors

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

OPERATING MANUAL. ba15358e03 09/2014 F 500 DIN, F 500 BNC F 800 DIN, F 800 BNC FLUORIDE SENSITIVE ELECTRODE

ABB ph/orp analyzer and probe package

S8000 Series ph/orp Electrode Platform. Self Cleaning Flat Surface ph/orp Electrodes LIQUID ANALYTICAL SOLUTIONS THE NEXT GENERATION

Technical Information Memosens CPS96D

OPTITEMP TT 10 C/R Technical Datasheet

Conductivity Transmitter

B Operating Instructions V1.00/EN/

Ceramax CPS341D. Technical Information

TIDALFLUX 2300 F Technical Datasheet

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Condumax CLS15 and CLS15D

Bulb ph and ORP Electrodes

Measuring and Controlling Unit Multronic OC

B Operating Instructions /

1000TR. Instructions

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

Condumax CLS15 and CLS15D

Condumax CLS21 and CLS21D

S8000 Series ph/orp Electrode Platform. Knowledge and Experience You Can Depend On. Self Cleaning Flat Surface ph/orp Electrodes

BATCHFLUX 5500 C Technical Datasheet

OPERATING MANUAL. ba77044e01 03/2014 FDO 1100 IDS OPTICAL D.O. SENSOR

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

Condumax W CLS15 and CLS15D

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Measuring and Controlling Unit Multronic

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

Technical Information Condumax CLS15D/CLS15

Condumax CLS21 and CLS21D

ph / ORP Measurement mypro CPM 431

Signet 2750 DryLoc ph/orp Sensor Electronics

HBPH-MK2 Brine/NH3 Leakage Sensor

Signal converter for electromagnetic flowmeters

Multi-Electrode Mounting (used for ph, Orp and Specific Ion) Honeywell Proprietary

Memosens New technology for contactless, inductive, digital transmission of ph signals

Measuring Nitrate in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

OPTIFLUX 1000 Handbook

Technical Information Condumax CLS21D/CLS21

Key Number I II III IV V _ - - _ - - _ - _, _,

OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE

BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

ph/orp Measurement OPM223/253

Operating manual FDO 925. Optical D.O. sensor

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Conductivity sensor for hygienic applications

OPTIFLUX 2000 Technical Datasheet

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

TARAline CS4. Data Sheet

Differential ph Design Overcomes Common ph Sensor Challenges

WATERFLUX 3070 Technical Datasheet

Top spin Nr /

GRUNDFOS DATA BOOKLET DIP. Measuring amplifiers and controllers, preassembled systems. Up to 3 parameters (Cl 2, ClO 2, O 3, ph, ORP)

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

Digital inductive conductivity transmitter

Technical specification FLUXUS F401 H2O

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Signet 2610 Process Optical Dissolved Oxygen Sensor

Digital conductivity transmitter

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

ORP100 Sensor. Edition 1.0. User Manual

New Technology for Monitoring Cycle Chemistry. David M. Gray McIlvaine Hot Topic Hour February 21, 2013

Sensor PAR xxx

Rebuild 19mm & 25mm Sensors

ph Measurement Good Operating Procedures for ph Sensors Mettler-Toledo AG Process Analytics Quality Measurements for In-Line Applications

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Valve Island with Electronic I/O

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

OPERATING MANUAL OPERATIONS MANUAL. ba76197e01 10/2017 FDO 4410 FDO 4410W FDO 4410 FDO 4410W OPTICAL D.O. SENSOR

Transcription:

OPTISENS PH 8390 Technical Datasheet ph sensor for water and wastewater industry Large PTFE diaphragm and integrated Pt100 Robust sensor design for harsh applications Low maintenance costs and a long life cycle The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE

CONTENTS OPTISENS PH 8390 1 Product features 3 1.1 ph sensor for water and wastewater applications... 3 1.2 Design and options... 5 1.3 ph measurement... 7 2 Technical data 9 2.1 Technical data... 9 2.2 Dimensions... 10 3 Installation 11 3.1 General notes on installation... 11 3.2 Intended use... 11 3.3 Pre-installation requirements... 11 3.4 Installing the sensor... 12 3.4.1 General installation instructions... 12 4 Electrical connections 13 4.1 Safety instructions... 13 4.2 Connecting the cable to the sensor... 13 4.3 Connecting the sensor cable to the MAC 100... 14 4.4 Connecting the external temperature sensor... 15 5 Order information 16 5.1 Order code... 16 5.2 Accessories... 18 6 Notes 19 2

OPTISENS PH 8390 PRODUCT FEATURES 1 1.1 ph sensor for water and wastewater applications The OPTISENS PH 8390 sensor is characterised by standardised design, easy handling and a long life cycle. In combination with the MAC 100 signal converter it is possible to create an extremely reliable and low-cost measurement system, which is suitable for a wide range of water and wastewater measurement tasks. Designed as combined sensor with built-in reference electrode the OPTISENS PH 8390 is equipped with PTFE diaphragm and integrated temperature sensor Pt100. The sensor can be easily adapted to various application requirements and it is extremely service friendly and durable. 1 Attached cable or 4-pin connector 2 CPVC body 3 Diaphragm 4 Membrane glass 3

1 PRODUCT FEATURES OPTISENS PH 8390 Highlights Large PTFE diaphragm for reliable ph measurement Double junction for extended lifetime and a wide application range Suitable for connection to the MAC 100 signal converter Available with 4-pin military connector or attached cable up to 10 m / 33 ft. With integrated Pt100 for temperature compensation Various mounting assemblies for an easy installation and handling Industries Industrial wastewater Municipal wastewater Water Applications Monitoring of surface and wastewater Control of biology in wastewater Neutralisation in municipal wastewater Process control Dosage of flocculation agents Oily and greasy media 4

OPTISENS PH 8390 PRODUCT FEATURES 1 1.2 Design and options The sensor type is equipped with a large PTFE diaphragm, Pt100 temperature sensor and is available with CPVC body material. It can be easily adapted to various application requirements and can be installed directly into a pipe or tank with the 3/4" NPT (male) process connection. The OPTISENS PH 8390 sensor is manufactured using highly sensitive membrane glass which can be used in almost all standard water and wastewater applications due to its robust sensor design. The sensor is suitable for connection to the MAC 100 signal converter. MAC 100 signal converter for various analytical parameter A complete measuring system consists of: MAC 100 signal converter 1 or 2 sensors Mounting assemblies Up to 2 sensors (for identical or different parameters) can be connected to the signal converter. The MAC 100 signal converter can be adapted perfectly for your requirements. Select between 1 or 2 signal inputs, 3 x outputs, relays, various operation language, power supply and further additional features. The standardised user interface also speeds up commissioning of the device. 5

1 PRODUCT FEATURES OPTISENS PH 8390 Made to Fit Mounting assemblies SENSOFIT series As a complete provider for water and wastewater analysis, we naturally offer a complete range of assemblies, like retractable, immersion and flow-through assemblies in a wide range of materials. Special versions for special operating conditions are available on request. For the OPTISENS PH 8390 sensor type the following individual assemblies are available: SENSOFIT FLOW 1000 series - Flow-through assemblies SENSOFIT IMM 2000 series - Immersion assemblies For further information please consider the technical datasheets. 6

OPTISENS PH 8390 PRODUCT FEATURES 1 1.3 ph measurement Figure 1-1: Measuring principle for ph measurement 1 Reference electrode 2 Measuring electrode 3 Diaphragm in contact with KCl solution and measuring medium 4 Inner ph 7 buffer solution 5 Surface potential on the inside (contact with buffer solution) 6 ph sensitive glass (membrane glass) 7 Surface potential on the outside (contact with measuring medium) 8 Measuring medium The measuring principle of a ph sensor is based on a membrane glass (ph sensitive glass). When the membrane glass gets into contact with a liquid, a thin layer of hydrated gel developes on the surface, enabling an ion exchange between the glass surface and the liquid. The so-called Nernst potential builds up on the glass surface. If both sides of the glass are in contact with liquids, a voltage may be detected between the two surface potentials. The voltage correlates to the difference in H + ion concentration and thus to the difference of ph values in both liquids. The ph sensor contains an internal buffer solution with a known ph value. If the ph value of the measuring medium on the outside of the sensor is equal to the ph value of the inner buffer, the resulting voltage is 0 V. If the ph value of the medium differs from the internal ph value, a voltage between the internal and the external layer can be measured. From the resulting voltage, the ph difference of the two liquids can be calculated. The voltage is measured using a measuring electrode and a reference electrode; both are built into the sensor. The measuring electrode is in contact with the known buffer solution in the ph sensitive glass bulb. The reference electrode is immersed into a saturated solution of potassium chloride (KCl). The KCl solution itself is in electrical contact with the measuring medium by means of a diaphragm. The diaphragm prevents the measuring medium from penetrating into the reference system but still allows electrical contact with the measuring medium. 7

1 PRODUCT FEATURES OPTISENS PH 8390 The voltage change of a ph sensor at 25 C /77 F is around 59 mv for each ph unit. This is also called the slope of the ph sensor. The slope is temperature dependent and decreases over life time of the sensor. Figure 1-2: Optimal slope at 25 C /77 F To compensate for the temperature dependency of the ph measurement, the temperature of the medium can be measured and automatically compensated in the signal converter. Figure 1-3: Temperature dependency of the slope 8

OPTISENS PH 8390 TECHNICAL DATA 2 2.1 Technical data The following data is provided for general applications. If you require data that is more relevant to your specific application, please contact us or your local sales office. Additional information (certificates, special tools, software,...) and complete product documentation can be downloaded free of charge from the website (Downloadcenter). Design Measuring principle Potentiometric Measuring range 0 14 ph Shaft diameter 20 mm / 0.79" Insertion length 23 mm / 0.91" or 44 mm / 1.73" Temperature sensor Pt100 Connector 4-pin military connector or attached cable (7.26 m / 25 ft or 10 m / 33 ft) Measuring accuracy Accuracy Reproducibility +/- 0.1 ph unit +/- 0.1 ph unit Operating conditions Temperature range -5 +80 C / +23 +176 F Pressure range Max. 5.9 bar at 25 C / 85 psi at 77 F Conductivity Min. 150 µs/cm Installation conditions Weight approx. Process connection Approx.193 g / 0.43 lb 3/4" NPT (male) Materials Sensor shaft CPVC Membrane glass Multi purpose glass Inner buffer ph 7.0 Reference KCl gel double junction Diaphragm PTFE 9

2 TECHNICAL DATA OPTISENS PH 8390 2.2 Dimensions Figure 2-1: Dimensions OPTISENS PH 8390 Dimensions [mm] Dimensions [inch] a Ø 33 Ø 1.3 b 3/4 NPT (male) c 23 / 44 0.91 / 1.73 d 128 5.04 10

OPTISENS PH 8390 INSTALLATION 3 3.1 General notes on installation Inspect the packaging carefully for damages or signs of rough handling. Report damage to the carrier and to the local office of the manufacturer. Do a check of the packing list to make sure that you have all the elements given in the order. Look at the device nameplate to ensure that the device is delivered according to your order. 3.2 Intended use Responsibility for the use of the measuring devices with regard to suitability, intended use and corrosion resistance of the used materials against the measured fluid lies solely with the operator. The manufacturer is not liable for any damage resulting from improper use or use for other than the intended purpose. The intended use of OPTISENS PH 8390 sensor is the measurement of ph in water liquids. The sensor is suitable for connection to the MAC 100 signal converter. 3.3 Pre-installation requirements Never touch or scratch the membrane glass of the sensor. Make sure that the glass tip is clean and dust-free. If necessary, clean the tip as described in the manual of the sensor. Figure 3-1: Handling the sensor Unpacking the sensor Gently pull the protection cap from the sensor 1. Lay the sensor on a soft mat/tissue 2. Keep the protection cap in the original packaging 3. 11

3 INSTALLATION OPTISENS PH 8390 3.4 Installing the sensor 3.4.1 General installation instructions The sensor tip must always have full contact with the measuring medium. The mounting position of the sensor should not deviate more than 75 from vertical position (sensor tip pointing downwards). Doing otherwise might cause internal air bubbles to float into the sensor glass tip. This would interrupt the electrical contact between the inner buffer solution and the glass surface. Figure 3-2: Installation requirements 1 Measuring medium 2 Maximum deviation of 75 from vertical position 12

OPTISENS PH 8390 ELECTRICAL CONNECTIONS 4 4.1 Safety instructions All work on the electrical connections may only be carried out with the power disconnected. Take note of the voltage data on the nameplate! Observe the national regulations for electrical installations! Observe without fail the local occupational health and safety regulations. Any work done on the electrical components of the measuring device may only be carried out by properly trained specialists. Look at the device nameplate to ensure that the device is delivered according to your order. 4.2 Connecting the cable to the sensor Moisture inside the sensor connector must be avoided! Moisture may cause a short-circuit and deliver erratic readings! If moisture has entered the connector dry it with air (e.g. hair blower). Figure 4-1: Connecting the cable to the sensor Connecting the cable to the sensor (only for sensor with 4-pin military connector) Ensure that the cable and the sensor connector are absolutely dry 1. Screw the cable connector 2 on to the sensor connector 3 and tighten it by hand. 13

4 ELECTRICAL CONNECTIONS OPTISENS PH 8390 4.3 Connecting the sensor cable to the MAC 100 All work on the electrical connections may only be carried out with the power disconnected. Take note of the voltage data on the nameplate! Look at the device nameplate to ensure that the device is delivered according to your order. Figure 4-2: Sensor connection terminals on the MAC 100 dual channel version 1 Sensor connection terminals 2 Terminal block S (protective earth) 3 Terminal block Pos.A: terminal for sensor and temperature 4 Terminal block Pos.B: terminal for sensor and temperature MAC 100 single channel version is equipped only with terminal block Pos. A. MAC 100 dual channel version is equipped with terminal block Pos. A and Pos. B. Wire Black (inner coax shield) Transparent (coax core) White (Pt100) Red (Pt100) Terminal block Pos.A/B N (ref.) O (ph / ORP) P X 14

OPTISENS PH 8390 ELECTRICAL CONNECTIONS 4 Figure 4-3: Connecting the sensor cable The following instructions describe the connection of the sensor cable. Connecting the sensor cable to the signal converter Thread the sensor cable through the outer right cable gland 1. Push the black wire (inner coax shield) 4 into terminal N 2 and the transparent wire (coax core) into terminal O 3. To remove a wire, press down the white clip 5 on the corresponding terminal and pull the wire out 6. 4.4 Connecting the external temperature sensor Connect an external Pt100 or Pt1000 sensor to terminal block Pos.A/B of the signal converter according to the following drawings: Figure 4-4: Connection of an external Pt100/1000 temperature sensor to the signal converter 1 2-wire connection 2 3-wire connection 15

5 ORDER INFORMATION OPTISENS PH 8390 5.1 Order code The characters of the order code highlighted in light grey describe the standard. VGA U 4 Sensor type 2 OPTISENS PH 8390 Measuring range 1 0...14 ph Diaphragm 2 PTFE Reference 1 KCl gel double junction Body material 1 CPVC Glass 1 General purpose glass Process conditions 1-5...+80 C, max. 5.9 bar at +25 C / +23...+176 F, max. 85 psi at +77 F Process connection 1 3/4" NPT (male) Insertion length 1 23 mm / 0.91 2 44 mm / 1.73 Sensor features 1 Standard Sensor option 1 Pt100 Carried forward Continued next page 16

OPTISENS PH 8390 ORDER INFORMATION 5 VGA U 4 Connector type 1 Attached cable 2 4-pin military connector Cable 0 None 1 Cable ph/orp-w US Cable features 0 None 1 Coax, single screen Cable length 0 None 2 7.62 m / 25 ft. 3 10 m / 33 ft. Cable options 0 None 2 Core sleeves ends Documentation 0 None 1 English 2 German 3 French 4 Spanish 17

5 ORDER INFORMATION OPTISENS PH 8390 5.2 Accessories Consumables Order code 250 ml buffer solutions ph4 XGA S 010020 250 ml buffer solutions ph7 XGA S 010030 Accessories Order code SENSOFIT FLOW 1000 Flow-through assembly Please see technical datasheet SENSOFIT FLOW 1000 SENSOFIT FLOW 1710 Flow-through assembly Please see technical datasheet SENSOFIT FLOW 1710 SENSOFIT IMM 2000 Immersion assembly Please see technical datasheet SENSOFIT IMM 2000 SENSOFIT IMM 2920 Immersion assembly Please see technical datasheet SENSOFIT IMM 2920 OPTISENS cable PH/ORP-W-US-4P-25 for 4 pin military XGA W 0 12221 connector, 7.62 m / 25 ft. OPTISENS cable PH/ORP-W-US-4P-33 for 4 pin military XGA W 0 12261 connector, 10 m / 33 ft. 18

OPTISENS PH 8390 NOTES 6 19

K K K KROHNE Process instrumentation and measurement solutions KROHNE - Subject to change without notice. Flow Level Temperature Pressure Process Analysis Services Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 47058 Duisburg (Germany) Tel.: +49 203 301 0 Fax: +49 203 301 10389 info@krohne.com The current list of all KROHNE contacts and addresses can be found at: