PES Eddy Current Proximity Sensor User s Manual P/N M8A-100

Similar documents
SPES Underwater Eddy Current Proximity Sensor User s Manual P/N M2A-107

SPES Underwater Eddy Current Proximity Sensor User s Manual P/N M3A-103

1-830 SERIES DISPLACEMENT TRANSMITTER

121PB - PRO UNEVEN BARS

CEC VIBRATION TRANSMITTER

Landscape Drag OWNER S MANUAL

Tube Facing Tool.

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

Dynamo Brushless DC Motor and GreenDriveTM Manual

Video Wall Installation Instructions 2W X 3H, 3W X 3H

KFI Hybrid Mount Installation Manual

INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

ZOOM Software Measurement and Graph Types

2011 / Circuit Tracer

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N)

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

NRU Diode Replacement

Magnetic Inductive Flow Sensor induq

Rosemount 5408 and 5408:SIS Level Transmitters

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

Installation Instructions Space Temperature Transmitter

Digital Interface Option "OPC-E1-DIO"

TA MHz oscilloscope probe TA MHz oscilloscope probe

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start

Foot Rail. Land Rover Discovery 5 (L462) START HERE! READ ME FIRST

User Guide. For. Alpha Antenna. Model: Multiband (Black Match)

S&C Scada-Mate Switching Systems Outdoor Distribution Interrupter Replacement 14.4 kv through 34.5 kv

READ ME! IMPORTANT WARNING! ENG. LED Light Bar Rack Mount Brackets

E-400 endstufe. user manual

SAFETY SENSORS FIELD OF VIEW WILL BE ALTERED WITH USE OF THE REPLACEMENT BUMPER. Injury hazard

INSTALLATION INSTRUCTIONS

incorrect use or handling that exceeds normal operating limits.

VT1586A Rack Mount Terminal Panel Installation and User s Manual

USER MANUAL Universal Gateway U9921-GUV (P/N: 40994G-01)

Pushbutton Bollard. Wireless Control for BlinkerSign, RRFB or BlinkerBeacon User Guide. Blinker Division Solar LED Solutions

INSTALLATION INSTRUCTIONS

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

Installation Instructions

Operator s Manual. PP016 Passive Probe

ATV CULTIVATOR OWNER S MANUAL

User Guide. For. Alpha DX Sr Antenna

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

9 QUICK RELEASE WOODWORKING VISE

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Keychain Radio Remote Control System

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Grid Radar Installation Manual

Fulfill Retrofit and Integrated Melter Capacitive Level Sensor P/N , and

Mounting Instructions for Cisco Aironet 1550 Series Outdoor Access Point Pole-Mount Kits

INSTRUCTION MANUAL. MODEL: Vintage 60R. Vintage Series Guitar Amplifi er

Model Numbers: P/N Date TPS-200 POLE SAW ATT TPS-200. Supplier To The Outdoor Power Equipment Industry

CHANCE Proximity Voltage Indicator

Dawson DDM190. Digital Multimeter User s Manual

ATV Adjustable Drag Harrow

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

RATCHET CABLE CUTTER

ELPMB27. Short Throw Projector Wall Mount Installation Manual xxx(fr) xxx(de) xxx(it) xxx(es) xxx(pt) xxx(zhs)

MSP-DCCLFSD LCD Flat Screen Swing-Down Mount

RESIDENTIAL MOTORIZED STORAGE UNIT

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

Field Hub Installation Guide. P/N Rev. C 05/15

Motor Vibration. Detect Mechanical & Electrical Motor Faults with Vibration Monitoring Instrumentation. IMI Sensors - A PCB Piezotronics Division

For detailed specifications and ordering info go to

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

returned to your distributor for attention. 14. Do not operate the function switch while the instrument is connected to a circuit.

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

Assemble and Adjustment Instructions and Flex Balance Beam and Crank Balance Beam

INSTRUCTION MANUAL LKG

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

FMG90 Series Electromagnetic Flow Meter

Yagi and Omni Antennas Installation Manual

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

General Installation Instructions

Service Manual for Installers Troubleshooting for Power-Line Communication SUNNY BOY 240-US / SUNNY MULTIGATE-US

User s Manual Current Probe. IM E 2nd Edition IM E

Operating Manual. Differential Pressure Transmitter DPS 100

Pole Mount Installation Guide

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Flexproof-Cutter AF-30

User Guide for the Alpha Loop Sr Antenna

Foot Rail. Volkswagen T5 / T6 Caravelle / Transporter START HERE! READ ME FIRST

Instructions for Installation. S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection TABLE OF CONTENTS INTRODUCTION INSTALLATION

i sburgh COMPACT BENDER ASSEMBLY INSTRUCTIONS & PROJECT IDEAS Rev 08/00

Installation Instructions

D3400 digital power amplifier. user manual

Operating Manual 6 Industrial Bench Grinder ATBG280/

P4263TP. Installation Guide. Low-Profile Tilting Portrait Mount for Flat-Panels

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

A-16D A-Net Distributor

2015 RIGOL TECHNOLOGIES, INC.

Agilent G1888 Network Headspace Sampler

E-400 power amplifier. user manual

WARNING Honda CR-V Honda Element Installation Instructions BX2232. Serial Number

Transcription:

PES -110 Eddy Current Proximity Sensor User s Manual P/N 9431-09M8A-100

Safety Information The following manual contains information and warnings. They must be followed in order to keep the instrument in a working condition and ensure safe operation. Safety Symbols Safety Precautions Warning - Danger - Identifies conditions or practices that could cause physical harm or death. Caution - Identifies conditions or practices that could result in a permanent loss of data or damage the measuring chain and/or other equipment to which it is connected. Important Information - Identifies important information, hints, and tips that must be read and applied. Warning - Danger Caution To use the described product correctly and safely, read and follow all safety instructions or warnings that appear throughout this manual. This product in intended to be used by qualified operators and maintenance personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and maintenance information before using this product. Install and use this product only as specified in this manual or the protection provided by this product might be impaired. When in doubt that safety protection has been impaired, make this product inoperative and secure it against any unintended operation. Do not use this product in wet environments. The VibroSystM logo, ZOOM, and PES are registered trademarks or trademarks of VibroSystM Inc. This manual is provided solely for guidance. VibrosystM Inc. takes no responsibility or liability for any damage caused by accidents, improper installation or misuse. Liability is limited to the repair and/or replacement of defective products. VibroSystM Inc. 2727 Jacques-Cartier E. Blvd, Longueuil, QC, Canada J4N 1L7 Phone: 450 646-2157 U.S. Toll-free Line: 800 663-8379 Email: techsupp@vibrosystm.com www.vibrosystm.com 2 PES-110 - User s Manual 2015 VibroSystM Inc. All rights reserved

TABLE OF CONTENTS 1. PES-110 SENSOR OVERVIEW... 5 1.1 Description... 5 1.2 Main Unit Interventions... 5 2. SENSOR OPERATION... 6 2.1 Connecting the PES-110 Sensor... 6 2.2 Assessing the Actual Sensitivity... 7 2.2.1 Measuring Current Output (Iout) and the Corresponding Distance... 8 2.2.2 Taking a Measurement with the Sensor Installed... 9 2.2.3 Calculating the Sensitivity... 9 2.2.4 Adjustment Through the ZOOM Configuration Software... 10 3. SENSOR INSTALLATION OVERVIEW... 11 3.1 Sensor Positioning... 11 3.2 Typical Installation... 11 APPENDIX: TEMPLATE FOR RECORDING DISTANCE VALUES VS I out PES-110- User s Manual 3

4 PES-110 - User s Manual

1. PES-110 SENSOR OVERVIEW 1.1 Description The PES-110 proximity sensor is designed for non-contact measurements of relative vibration, displacement, and axial positioning. It acquires data by measuring the distance between its sensing face and a metallic target surface. Furthermore, this sensor is equipped with built-in conditioning circuitry allowing it to be directly connected to processing instrumentation through an M12 connector and signal cable. The PES-110 covers a 0 to 10 mm [0 to 394 mils] measuring range. PES-110 Eddy Current Proximity Sensor M12 Connector PES-110 Sensor Sensing Face Tightening Nuts 1.2 Main Unit Interventions Sensor holders must be bolted or welded at appropriate locations. Signal cables must be routed and protected from the sensor all the way to the acquisition unit. Caution Instructions for sensor installation and connection must be thoroughly followed to ensure a safe and proper operation. In order to complete the commissioning, VibroSystM must be contacted when Section 2.2 (Assessing the actual sensitivity) is reached. PES-110- User s Manual 5

2. SENSOR OPERATION 2.1 Connecting the PES-110 Sensor The PES-110 sensor must first be connected to a 24VDC power supply and a receiving instrument with a signal cable and M12 connector. It is important to confirm the sensor s functionality before proceeding with a permanent installation. The signal cable s shield must be grounded. It is important to ground the shield on one end only to avoid creating a ground loop. If the M12 connector at the end of the cable is insulated from the shield, the shield must then be grounded on the acquisition unit side. However, if the M12 connector at the end of the cable is connected to the shield, attaching the cable to the already grounded PES-110 sensor will automatically ground the shield. In this case, the shield must not be grounded on the acquisition unit side. PES-110 Pinout 3 4 5 2 1 The signal cable provided by VibroSystM may be replaced by any cable having similar characteristics. The table below shows the color codes, designations and specifications for VibroSystM s signal cable. M12 Connector Pin # Corresponding Color Code Designation Specifications 1 Brown Power Supply +24 VDC 2 White Current Output 4-20 ma (proportional to sensor s full range) 3 Blue Common 0 V 4 Black Voltage Output 0-10 V (proportional to sensor s full range) 6 PES-110 - User s Manual

2.2 Assessing the Actual Sensitivity The PES-110 proximity sensor is calibrated to produce a linearized output based on an FE360 steel target. Because the sensitivity of eddy current sensors is affected by the target s material, the actual sensitivity must be determined. Important Information Failure to correctly assess and compensate the sensitivity will result in incorrect measurement results as presented in the illustration below. PES-110 Calculated Distance vs Sensor Current Output Real Distance vs Sensor Output Correct Calculated Distance (With Compensation) Incorrect Calculated Distance (Without Compensation) PES-110- User s Manual 7

2.2.1 Measuring Current Output (I out ) and the Corresponding Distance To assess the sensor s actual sensitivity, physical distance and current measurements must first be taken using a target made of the same material as the real target. Minimum dimensions for the target are: 50mm x 50mm x 2mm [2" x 2" x 1/16"]. Proceed as follows: Fill the table with measurements (distance vs current), equally distributed on the full current scale. Add non- metallic spacers between the sensor s tip and the target until I out max. is approximately reached. Note down the current value and the distance (total spacer thickness) in the table. Gradually remove spacers to approximately reach the next I out level and again, write down the current value and distance. Repeat until the table is filled. The last I out value is measured without spacers (0mm), with the sensor s tip placed directly against the target. Recorded Distance Values vs I out for PES-110 Important Information Section 2.2.1 must be completed BEFORE installing the sensor. Sections 2.2.2, 2.2.3, and 2.2.4 must be completed AFTER installing the sensor. In the examples below, calculations are in metric format. All distances may also be measured in inches with the resulting values used in the same formulas. Ideal level of I out (ma) 20 17.3 14.7 12 9.3 6.7 4 Example of Recorded Distance Values vs I out for PES-110 I out B I op approx. I out A 20 17.7 14.9 12.9 9.7 6.5 3.4 Measured distance (mm) 9.9 8.1 6.5 5.5 4.1 2.4 0 d B d A 8 PES-110 - User s Manual

2.2.2 Taking a Measurement with the Sensor Installed With the sensor now installed, take a measurement and note the real operating current (I op ). Example with PES-110 I op = 12.9 ma 2.2.3 Calculating the Sensitivity Important Information For best results, the sensor should be installed at a distance corresponding to the middle of the measuring range when the target is stationary (unit stopped). Select two points in the table on either side of the value closest to I op. These two points (A & B) will be used to define the linear equation. The selected points should be at an equal distance from I op. Ideally, point A should be at I op - 2.5 ma and point B at I op + 2.5 ma. For example, if I op = 12.9 ma: Point A: I op - 2.5 ma= 10.4 ma (closest correspondence in the table: I out A = 9.7 ma, d A = 4.1 mm) Point B: I op + 2.5 ma= 15.4 ma (closest correspondence in the table: I out B = 14.9 ma, d B = 6.5 mm) a) Using selected points A and B, calculate «m» (the sensitivity or gain). Example m = d B - d A I outb - I outa m = 6.5-4.1 14.9-9.7 = 2.4 5.2 = 0.462 b) Using the formula below, calculate «b» (the y-intercept) of the linear equation, using calculated «m», measured current and I out and measured distance «d» corresponding to point A or point B. c) The equation to calculate the compensated distance corresponding to the sensor current output is the following: d C = (m x I out ) + b Example with values closest to I op b = d - (m x I out ) b = 6.5 - (0.462 x 14.9) = - 0.384 mm Where: d C is the calculated distance (in mm) d) Verify the «m» and «b» calculated values by applying the following formula on the measured value between the A and B coordinates: for I out to equal 12.9 ma, verify that d C = 5.5 mm (± 10% of range). d C = (0.462 x 12.9) - 0.384 = 5.58 mm PES-110- User s Manual 9

2.2.4 Adjustment Through the ZOOM Configuration Software Proceed with the final adjustment through the ZOOM Configuration software. Select Sensor Configuration, and in the Range tab of the dialog window, enter the Maximum and Minimum values of the Raw output range. Formulas for Adjusting the Raw Output Range Maximum (m x 20 ma) + b 10 0 Minimum (m x 4 ma) + b 0 Note: In the Trending and alarm range section, the Maximum and Minimum values must be within the limits of the Raw output range. Example with Calculated Values Maximum (0.462 x 20 ma) - 0.384 8.86 1.46 Minimum (0.462 x 4 ma) - 0.384 0 10 PES-110 - User s Manual

3. SENSOR INSTALLATION OVERVIEW 3.1 Sensor Positioning Before determining where to install the sensor, consider the following: The sensor s surface must face the target. The maximum extension cable length must be considered. From the sensor to the acquisition unit, the maximum distance is 300 m [984 ft] for the current output, and 100 m [328 ft] for the voltage output. 3.2 Typical Installation Caution The PES-110 sensor must be properly connected with the signal cable well protected to avoid any sort of mechanical damage. Important Information VibroSystM recommends relying on the services of a trained technician for supervising the installation of these proximity sensors and finalizing the ZOOM software configuration. Metallic Surface Metal-Free Zone Tightening Nuts 24 mm [0.94"] M12 Connector Signal Cable PV300915A PES-110- User s Manual 11

APPENDIX: TEMPLATE FOR RECORDING DISTANCE VALUES VS I out Unit no.: Sensor S/N: Position: Unit no.: Sensor S/N: Position: Unit no.: Sensor S/N: Position: Unit no.: Sensor S/N: Position: Unit no.: Sensor S/N: Position: Unit no.: Sensor S/N: Position: 12 PES-110 - User s Manual