EVALUATING ROLLING SHEAR STRENGTH PROPERTIES OF CROSS LAMINATED TIMBER BY TORSIONAL SHEAR TESTS AND BENDING TESTS

Similar documents
Connection and performance of two-way CLT plates

EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION

SIMPLIFIED DESIGN PROCEDURE FOR GLUED-LAMINATED BRIDGE DECKS

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

STRUCTURAL TIMBER DESIGN

Three-dimensional finite element analysis of the Japanese traditional post-and-beam connection

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS

The fracture of wood under torsional loading

Dowel connections in laminated strand lumber

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber (LVL), and Cross-Banded LVL (LVL-C)

Glued laminated timber beams repair.

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey

PRO LIGNO Vol. 11 N pp

Space-frame connection for small-diameter round timber

Korean standards of visual grading and establishing allowable properties of softwood structural lumber

Pull-compression tests on glued-in metric thread rods parallel to grain in different timber species and laminated veneer lumber

Anti-check bolts as means of repair for damaged split ring connections

Investigations on the Effectiveness of Self-tapping Screws in Reinforcing Bolted Timber Connections

Comparison of Eurocodes EN310 and EN789 in Determining the Bending Strength and Modulus of Elasticity of Red Seraya Plywood Panel

Simplified analysis of timber rivet connections

STRUCTURAL FINGER JOINTED SOLID TIMBER

Improved Arcan Shear Test For Wood

AN IMPROVED SHEAR TEST FIXTURE USING THE IOSIPESCU SPECIMEN

Ductility of large-scale dowelled CLT connections under monotonic and cyclic loading

Defect detection in lumber including knots using bending deflection curve: comparison between experimental analysis and finite element modeling

Detection and Assessment of Wood Decay in Glulam Beams Using a Decay Rate Approach: A Review

THE ENGINEERED WOOD ASSOCIATION

MAT105: Floor Framing

A Numerical Study of the Transverse Modulus of Wood as a Function of Grain Orientation and Properties

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

APA Performance Rated Rim Boards

BENDING STRENGTH PROPERTIES OF SCARF JOINTED EUROPEAN SPRUCE WOOD (Picea excelsa) Sotirios Karastergiou and George Ntalos ABSTRACT

Development of Wooden Portal Frame Structures with Improved Columns

Prediction of Reinforcement Effect by Screw on Triangular Embedment Perpendicular to the Grain with Variation of Screw Locations

Lawrence A. Soltis, M. and Robert J. Ross, M. 1

Derivation of Mechanical Properties of Rubberwood Laminated Veneer Lumber

Verification Processes for. (CLT) in the Frame of EN. Graz University of Technology. Speaker: holz bau forschungs gmbh, Graz

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS

STRENGTH OF GLUED LAMINATED SITKA SPRUCE MADE UP OF ROTARY-CUT VENEERS. R. F. LUXFORD, Senior Engineer

Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading

EVALUATION OF SCREWS USED IN LAMINATED VENEER LUMBER ROCKING CONNECTIONS

Title. CitationJournal of Wood Science, 58(4): Issue Date Doc URL. Rights. Type. File Information.

T Wooden Structures 1

Effect of shoulders on bending moment capacity of round mortise and tenon joints

Dowel type joints Influence of moisture changes and dowel surface smoothness. Erik Serrano and Johan Sjödin, Växjö University, Sweden

VERSA-LAM. An Introduction to VERSA-LAM Products

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite.

IN-PLANE STIFFNESS OF TRADITIONAL TIMBER FLOORS STRENGTHENED WITH CLT

SIMULATION AND EXPERIMENTAL WORK OF SINGLE LAP BOLTED JOINT TESTED IN BENDING

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

COST Action FP1402. Basis of Structural Timber Design - from research to standards. Short Term Scientific Mission (STSM) Report

VIBRATIONAL MODES OF THICK CYLINDERS OF FINITE LENGTH

THE EFFECT OF THREAD GEOMETRY ON SCREW WITHDRAWAL STRENGTH

Section Downloads. Lumber Design Values. Lumber Standard. Western Lumber Product Use Manual. Section 05: Truss Materials.

Comparison of behaviour of laterally loaded round and squared timber bolted joints

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

Glulam Curved Members. Glulam Design. General Glulam Design. General Glulam Beams are Designed in the SAME Manner as Solid Sawn Beams

Lateral Load-Bearing Capacity of Nailed Joints Based on the Yield Theory

Effect of finger length on fingerjoint strength in radiata pine

Quality and Surface Modification of BC Softwood For Value-Added Products

THE EFFECT OF END DISTANCE AND NUMBER OF READY-TO- ASSEMBLE FURNITURE FASTENERS ON BENDING MOMENT RESISTANCE OF CORNER JOINTS.

Ingenious hardwood. Ingenious hardwood. Order our BauBuche sample box free of charge. 1

Aspen Art Museum Creating Innovative Wood Structure

ALONA YANSHINA EXERCISE 1.1

Load-carrying capacity of timber frame diaphragms with unidirectional support

CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES

THREE-DIMENSIONAL NONLINEAR FINITE ELEMENT MODEL FOR SINGLE AND MULTIPLE DOWEL-TYPE WOOD CONNECTIONS

INTERNATIONAL COUNCIL FOR BUILDING RESEARCH STUDIES AND DOCUMENTATION WORKING COMMISSION W18- TIMBER STRUCTURES

CHIPLESS MACHINING: CHALLENGES IN MANUFACTURE OF LAMINATED VENEER PRODUCTS

LP SolidStart Laminated Strand Lumber (LSL) and Laminated Veneer Lumber (LVL) Louisiana-Pacific Corporation Revised July 21, 2017

F'II'XURAI PROPERTIES. and DIiIENSIONAL STABILITIES of two ronsrsrfcions of 4 8inch,,l SOUTHERN PINE PIY WOOD. ris on m p o f I( F

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

Durability of adhesive bonds in cross-laminated timber (CLT) panels manufactured using Irish Sitka spruce

Hanger bolts and solar fasteners in sandwich panels

Combined stress analysis of mitered spline furniture joints under diagonal loading

Load carrying capacity of dowelled connections

NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1. Kug-Bo Shim* Ronald W. Wolfe. Marshall Begel

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2011

M. Bücker*, M. Magin. Institute for Composite Materials, Erwin-Schrödinger-Straße 58, Kaiserslautern, Germany

Module 3 Selection of Manufacturing Processes

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

EVALUATING BEARING PROPERTIES OF WOOD PEG CONNECTION USING FOUR DIFFERENT TEST METHODS. G. Y. Jeong* J. H. Kong

PROCEDURE FOR DESIGN OF GLUED-LAMINATED

Mira Dedijer 1, Stéphane Roche 2, Yves Weinand 3 1 INTRODUCTION 123. θ rotations.

Prying of a Large Span Base Plate Undergoing a Moment Load Applied by a Round Pier

ASSESSMENT OF COMPOSITES REINFORCED WITH INNOVATIVE 3D WOVEN HOLLOW FABRICS

THE INFLUENCE OF GEOMETRIC PARAMETERS AND MECHANICAL PROPERTIES OF ADHESIVE ON STRESS ANALYSIS IN ADHESIVELY BONDED ALUMINUM SINGLE LAP JOINT

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

Nail and screw withdrawal strength of laminated veneer lumber made up hardwood and softwood layers

25-Sep-17. SPECIES, SITE, SOIL, CLIMATE, MICROCLIMATE, WEATHER, GENES etc

Verbindungselemente Engel GmbH Weltestraße Weingarten DEUTSCHLAND. Manufacturing plant 74437, , ,

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

Bolts and Set Screws Are they interchangeable?

SCREW WITHDRAWAL RESISTANCE SHEET METAL SCREWS IN PARTICLEBOARD AND MEDIUM-DENSITY HARDBOARD

MANUFACTURING TECHNOLOGY

4.0 MECHANICAL TESTS. 4.2 Structural tests of cedar shingles

Please do not open this exam until you are told to do so.

DOWEL ACTION OF TITANIUM BARS CONNECTING MARBLE FRAGMENTS AT DIFFERENT ANGLES

Transcription:

EVALUATING ROLLING SHEAR STRENGTH PROPERTIES OF CROSS LAMINATED TIMBER BY TORSIONAL SHEAR TESTS AND BENDING TESTS Minghao Li 1, Frank Lam 2, and Yuan Li 3 ABSTRACT: This paper presents a study on evaluating rolling shear (RS) strength properties of cross laminated timber (CLT) using torsional shear tests and bending tests. The CLT plates were manufactured with Spruce-Pine-Fir boards and glued with polyurethane adhesive. Two types of layups (3-layer and 5-layer) and two clamping pressures (0.1 MPa and 0.4 MPa) were studied. For the torsional shear tests, small shear block specimens were sampled from the CLT plates and the cross layers were processed to have an annular cross section. Strip specimens were simply sampled from the CLT plates for the bending tests. Based on the failure loads, RS strength properties were evaluated by torsional shear formula, composite beam formulae as well as detailed finite element models, respectively. It was found that the two different test methods yielded different average RS strength value for the same type of CLT specimens. The test results showed that the CLT specimens pressed with the higher clamping pressure had slightly higher average RS strength. The specimens with thinner cross layers also had higher RS strength than the specimens with thicker cross layers. KEYWORDS: Cross laminated timber, rolling shear strength, torsional shear tests, bending tests 1 INTRODUCTION 1 Rolling shear (RS) stress in wood is defined as the shear stress in the radial-tangential plane perpendicular to the grain direction. RS strength and stiffness of wood is much lower than its longitudinal shear strength and stiffness. According to the Wood Handbook (FPL, 2010), RS strength normally varies between 18% and 28% of parallel-to-grain shear strength based on limited test data. In Eurocode 5 (2004), a characteristic RS strength of 1.0 MPa is used for wood independent of its strength class. Therefore, in timber design, high RS stresses should always be avoided due to the low RS capacity of wood. Cross laminated timber (CLT) consists of crosswise oriented layers of wood boards that are often glued by adhesives. RS strength and stiffness are not major design properties for timber. For CLT, however, RS strength and stiffness must be considered in some loading scenarios due to the existing cross layers. For example, when a CLT floor panel is supported by columns, highly concentrated loads in the supporting area may cause high RS stresses in 1 Minghao Li, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand, minghao.li@canterbury.ac.nz Formerly, University of British Columbia, 2835-2424 Main Mall, Vancouver, Canada 2 Frank Lam, University of British Columbia, 4041-2424 Main Mall, Vancouver, Canada, frank.lam@ubc.ca 3 Yuan Li, University of British Columbia, 2843-2424 Main Mall, Vancouver, Canada, ubcliy@interchange.ubc.ca cross layers; the same concerns may arise for designing short-span floors or beams. Therefore, there is a need to evaluate the RS strength and stiffness properties of CLT products to provide technical support for more robust designs. ASTM D2718-00 (2006) stipulates two test methods (planar shear test and short-span bending test) to evaluate shear properties of wood products. In the planar shear test, shear loads are applied by two metal plates face-glued onto the specimen. The short-span bending test is to load the specimen with small span-depth ratios to encourage shear failure mechanism. Norlin et al. (1999) used a short-span bending test to study longitudinal and RS shear strength properties of a laminated veneer product. Using nondestructive bending vibration tests, Fellmoser and Blass (2004) studied the influence of RS modulus on CLT stiffness as well as the relationship between shear deformations and the span-depth ratios. Mestek et al. (2008) studied the influence of shear deformations in cross layers on the load carrying capacity of CLT beams. Zhou et al. (2014) used both planar shear tests and short-span bending tests to study RS strength and stiffness properties of CLT specimens made by black spruce. The objective of this study is to evaluate the RS strength properties of non-edge-glued CLT plates by two test methods: torsional shear tests and short-span bending tests. The CLT plates were manufactured mainly by mountain pine beetle killed lodgepole pine, which is a major species

in the Spruce-Pine-Fir (SPF) group in Canada. Another important motivation for this study is to help recover the wood resource from the beetle attacked forests. This study is also focused on understanding the influence of the clamping pressure for curing adhesives and the thickness of cross layers on the RS strength properties of the CLT products. Table 1: CLT layup and lamination grade Type SPF5-0.1 & SPF5-0.4 Laminate Grade No.2/Stud/No.2 /Stud/No.2 Laminate thickness (mm) 34/19/34/ 19/34 Plate size L W H (mm) 3658 1219 140 2 METHOD SPF3-0.1 & SPF3-0.4 No.2/Stud/No.2 34 3658 1219 102 2.1 CLT PLATE SPECIMENS As shown in Figure 1, 5-layer Spruce-Pine-Fir (SPF5) plates and 3-layer S.P.F. (SPF3) plates were manufactured for the experimental studies. For each layup, two clamping pressures (0.1 MPa representing vacuum press and 0.4 MPa representing mechanic press) were used for the pressing process. Thus, combining the layup and the curing pressure, four types of CLT plates were studied. For each type, three full-size plates were sampled. In the following context, a SPF5-0.4 represents the 5-layer S.P.F. panel pressed under 0.4 MPa. Similarly, a 3-layer S.P.F plate pressed under 0.1 MPa is labeled as SPF3-0.1. Figure 1: Full-size CLT plates Table 1 shows the board grades, laminate thickness, and dimensions of the CLT plates. In the SPF5 plates, No. 2 or better boards were used for two face layers and the core layer while stud grade boards were used for two cross layers. In the SPF3 plates, No. 2 or better boards were used for two face layers and stud grade boards were used for the crosswise core layer. All the laminates were 34 mm x 138 mm boards except that the cross layers in the SPF5 plates were 19 mm x 138 mm boards. The average moisture content of the boards was about 13% with a coefficient of variation (COV) of 0.18. Modulus of Elasticity (MOEs) of the boards were also measured by transverse vibration tests following a test standard (ASTM D6874-03, 2009) before they were glued to the CLT plates. Table 2 shows the vibration MOE results which showed that the No.2 and better grade boards had higher stiffness than stud grade boards. Table 2: Vibration MOE of wood boards Grade MOE Mean (GPa) COV Sample size No. 2 or btr. 11.43 16.4% 256 Stud 10.66 18.5% 280 2.2 TORSIONAL SHEAR TESTS Figure 2 shows the schematics of a torsional shear specimen, in which the mid-layer, i.e., the cross layer in a CLT plate, has a milled-down annular cross section. The reason to have such a cross section is to facilitate the RS failure mechanism and reduce the stress concentrations typically experienced by a square-shaped shear plane. The specimens were processed in three steps. In the 1st step, 3-layer blocks were sampled from the full-size CLT plates. For the SPF5 specimens, two layers of wood needed to be removed. In the 2nd step, the 3-layer blocks were press drilled from the centre of the top face to the bottom face; in the 3rd step, the blocks were further processed by a CNC machine to achieve the annular cross section. It should also be noted that for each torsional shear specimen, the mid-layer was cut out from one piece of wood in order to eliminate the influence of gaps on the torsional shear stress distributions. Figure 2: Torsional shear specimens Figure 3 shows the test setup in which the torsional moment was applied via a steel arm firmly connected with one face layer of the specimen. The moment arm length was 500 mm. The other face layer of the specimen was

fully restrained onto the test table. The test to failure time for was kept in 5 ~ 10 minutes for each specimen. Figure 5: Cumulative distributions of peak torsional moments Table 3: Summary of torsional shear results Figure 3: Test setup of torsional shear test Figure 4 shows an example of RS failure mode observed in the cross layer. Most of the specimens had brittle failures and the cracks were developed at an inclined angle with respect to the top or bottom face of the specimen. Loaddisplacement curves from the actuator also indicated an approximate linear relationship up to the peak load followed with a sudden drop of the load due to failure. CLT Cross layer thickness (mm) Sample size Failure torque (N.m) mean COV SPF3-0.1 34 23 85.1 17.8% SPF3-0.4 34 25 84.6 16.6% SPF5-0.1 19 28 101.7 21.1% SPF5-0.4 19 31 104.0 16.4% Assuming rigid glue line bonding and homogeneous isotropic material properties, the maximum torsional shear stresses on an annular cross section can be calculated by the torsional shear formula: Figure 4: Rolling shear failure mode Figure 5 shows the cumulative distributions of the failure torsional moments for four types of specimens. Table 3 also lists the mean and COV for each type. It was found that the SPF5 specimens with 19 mm thick cross layers had much higher torsional shear capacity than the SPF3 specimens with 34 mm thick cross layer although the annular cross sections of these specimens are the same. On average, the SPF3 specimens pressed with 0.1 MPa and 0.4 MPa had almost the same torsional capacity. The SPF5 specimens pressed with 0.4 MPa had slightly higher torsional capacity. where T is the peak torsional moment, r o and r i are the outer radius and inner radius of the annular cross section. In this study, finite element models were also developed in finite element software ANSYS v14 (2011) to model the torsional shear specimens in order to consider the glue line shear stiffness and the orthotropic wood properties. Solid elements were used to model the wood boards and linear spring elements were used to model the glue line shear stiffness. Table 4 lists the input wood material properties. Poisson s ratios of lodgepole pine were obtained from the Wood Handbook (FPL, 2010). The parallel to grain modulus E L were obtained from the transverse vibration tests. Additional assumptions on other wood properties were given as follows. The perpendicular to grain modulus E T / E R was assumed to be 1/30 of E L. The parallel to grain shear modulus G LR or G LT was assumed to be 1/16 of E L. The rolling shear modulus G RT was assumed to be 1/10 of G LR or G LT. These assumptions are also consistent with commonly adopted assumptions for CLT strength and stiffness calculations in Europe (FPInnovations, 2011). Table 5 lists the shear stiffness of glue lines which were (1)

experimentally obtained by Schaaf (2010) using torsional shear testing methods. Table 4: Wood orthotropic properties for FE models Elastic properties (GPa) Poisson s ratios Grade G E L E T /E LR / R G G RT ν LR ν LT ν RT LT No. 11.43 0.381 0.714 0.071 2/ btr 0.316 0.347 0.469 stud 10.66 0.355 0.666 0.067 Table 5: Shear stiffness of glue lines Species S.P.F. Clamping pressure (MPa) Shear stiffness (N/mm 3 ) 0.1 19.0 0.4 20.6 Figure 6 shows the meshed FE model for the torsional shear specimen. The metal part of the test jig was also modelled. Figure 7 shows the RS stress distributions in the cross layers of the SPF3-0.1 and SPF5-0.1 specimens loaded under the average peak torsional loads. Apparently, the stresses were not uniformly distributed along the perimeter of the annular rings due to the orthotropic wood properties. Table 6 lists the average RS strength for each type of CLT specimen evaluated by the torsional shear formula and the FE model simulations. It was found that the torsional shear formula gives unreasonably high RS strength due to the assumption of homogenous isotropic material property. The FE models give rational evaluations which are in a reasonable range of RS strength compared with available test data. Figure 7: RS stress distributions in cross layers of SPF3-0.1 and SPF5-0.1 specimens (Pa) Table 6: Summary of average RS strength from torsional shear tests (MPa) CLT Cross layer thickness (mm) Shear Formula FE model SPF3-0.1 34 3.54 2.33 SPF3-0.4 34 3.52 2.31 SPF5-0.1 19 4.23 2.40 SPF5-0.4 19 4.33 2.46 Figure 6: FE model of a torsional shear test 2.3 SHORT-SPAN BENDING TESTS As shown in Figure 8, a series of three-point bending tests on strip specimens sampled from the full-size CLT plates have also been conducted by Yawalata and Lam (2011) following a test standard (ASTM, D198-05a, 2005). A span-to-depth ratio of 6 was used to encourage the RS failure mode. The wood fibres of the top and bottom layers of the specimens were parallel to the beam span. Table 7 lists the dimensions and the test results in terms of the mean and standard deviation of the failure loads. The bending test results showed that for the specimens with the same layup, the increased clamping pressure from 0.1 MPa

to 0.4 MPa seemed to slightly increase the load-carrying capacity on average. Figure 9: FE model of a SPF5 bending specimen Figure 8: Short-span bending test and RS failure mode Table 7: Summary of bending test results CLT Span x depth (mm x mm) Sample size Failure loads (kn) mean COV SPF3-0.1 612x102 30 15.13 10.8% SPF3-0.4 612x102 30 16.51 19.1% SPF5-0.1 840x140 30 20.98 16.2% SPF5-0.4 840x140 30 21.78 7.2% Assuming rigid glue line bonding and material continuity in the cross layers, the RS strengths of the bending specimens were evaluated by three composite beam theories: Layered beam (Bodig and Jayne, 1982); Gamma beam method (Eurocode 5, 2004); and Shear analogy method (Kreuzinger, 1999). Meanwhile, as shown in Figure 9, considering orthotropic wood properties, gaps between the wood boards in the cross layers and the glue line shear stiffness, detailed FE models were also developed in ANSYS v14 (2011) to study the RS stress distributions under the failure loads. The wood properties given in Table 4 and the glue line shear stiffness given in Table 5 were used for the FE model simulations. Similar to the torsional shear FE models, solid elements and linear spring elements were used for the wood members and the glue lines, respectively. Figure 10 shows the RS stress distributions of the SPF5-0.1 and SPF3-0.1 specimens under the average failure loads. It can be seen that the RS stress distribution was not continuous in the cross layer due to the gaps. The stresses in the vicinity of the gaps were much smaller than those in the central parts of the boards due to the shear stress release around the free edges. This type of RS stress distribution also agreed with the test observation that the RS failures of the specimens tended to occur at a certain distance (comparable to the thickness of the cross layers) from the location of the gaps. Figure10: RS stress distributions in cross layers of SPF5-0.1 and SPF3-0.1 specimens (Pa) Table 8 lists the average RS strengths evaluated by the composite beam theories and the FE modeling for each type of the specimens. For the SPF5 specimens, the

calculations by the beam theories agreed reasonably well with the FE results. However, for the SPF3 specimens, the beam theories significantly over-estimated the RS strength compared with the FE results. According to the composite beam calculations, the average RS strength of the SPF3 specimens with 34 mm thick cross layers was about 18 % higher than the SPF5 specimens with 19 mm thick cross layers. However, the FE results showed that the average RS strength of the SPF3 specimens was actually 8 % lower than that of the SPF5 specimens. The FE models are believed to be more accurate and the FE findings were also consistent with the torsional shear test results. If one considers the size effect on the RS strength of the cross layers, it is understandable that thick cross layers tend to have more volume of wood stressed under RS stresses than thin cross layers. Therefore, thick cross layers will normally have lower RS strength properties. Table 8: Average RS strength calculated by beam theories and FE models CLT type Layered beam Gamm a beam Shear analogy FE model SPF3-0.1 2.04 2.15 2.02 1.71 SPF3-0.4 2.22 2.34 2.20 1.87 SPF5-0.1 1.85 1.74 1.78 1.91 SPF5-0.4 1.93 1.81 1.85 1.98 3 CONCLUSIONS In this study, RS strength properties of CLT plates manufactured by S.P.F. boards and polyurethane adhesive were evaluated by torsional shear tests and short-span bending tests. The test results were analysed by torsional shear formula, composite beam theories and detailed FE modelling. Based on the test and modelling results, some conclusions are drawn as follows: Two different test methods yielded very different RS strength properties of the CLT specimens. Torsional shear tests gave higher average RS strength range (2.31 ~ 2.46 MPa) than that obtained from the short-span bending tests (1.71 ~ 1.98 MPa). Besides the different mechanism of the test methods, one reason might be that the bending specimens had gaps between the adjacent wood boards in the cross layers. However, the torsional shear specimens eliminated the influence of the gaps. On average, the SPF5 specimens with thin (19mm thick) cross layers had about 7 % higher RS strength than the SPF3 specimens with thick (34 mm) cross layers although the cross layers consisted of the same stud grade material. The thickness of cross layers seemed to affect the RS strength properties for the CLT specimens. For specimens with the same layup configuration, the increased clamping pressure from 0.1 MPa to 0.4 MPa increased the average RS strength of the CLT specimens by 4% approximately. The torsional shear formula is not suitable for evaluating RS strength properties of the torsional shear specimens. The composite beam theories should also be used with caution to evaluate the RS strength of the bending specimens. ACKNOWLEDGEMENT The authors would like to thank NSERC strategic network for engineered wood-based building systems for supporting this research. REFERENCES [1] ANSYS V14.0. 2011, Swanson Analysis System, Inc. Houston, PA, US [2] ASTM, D198-05a, 2005, Standard test method of static tests of lumber in structural sizes. ASTM International, U.S. [3] ASTM, D2718-00, 2006, Standard test methods for structural plates in planar shear (RS), ASTM International, U.S. [4] ASTM, D6874-03, 2009, Standard test methods for non-destructive evaluation of wood-based flexural members using transverse vibration, ASTM International, U.S. [5] Bodig J. and Jayne B.A., 1982. Mechanics of wood and wood composites. Van Nostrand Reinhold Co. NY, U.S. [6] European Committee for Standardization. 2004 Eurocode 5: Design of timber structures. Part 1-1: General Common rules and rules for buildings. EN 1995-1-1. Brussels: CEN. [7] Fellmoser, P. and Blass, H. J. 2004. Influence of RS modulus on strength and stiffness of structural bonded timber elements. CIB-W18/37-6-5. Edinburgh, U.K. [8] Forest products laboratory (FPL). 2010 Wood handbook - wood as an engineering material (centennial edition). Madison, WI. [9] FPInnovations. 2011 CLT handbook Chapter 3 Structural design of cross-laminated timber elements. Vancouver, BC. [10] Kreuzinger, H. (1999) Flaechentragwerke platten, scheiben und schalen ein Berechnungsmodell fuer gaengige statikprogramme. Bauen mit Holz. 01/1999, S.34-39 [11] Mestek P., Kreuzinger, H. and Winter S. 2008. Design of cross laminated timber (CLT). Proc. of WCTE 2008, Miyazaki, Japan. [12] Norlin L.P., Norlin C.M. and Lam, F. 1999 Shear behaviour of laminated Douglas fir veneer, Wood Sci. and Tech. 33: 199-208.

[13] Schaaf, A., 2010. Experimental investigation of strength and stiffness properties for cross laminated timber. Diplomarbeit, Karlsruhe Institute of Technology. Germany. [14] Yawalata D. and Lam F. 2011 Development of technology for cross laminated timber building systems. Research report submitted to Forestry Innovation Investment Ltd. University of British Columbia, Vancouver, British Columbia, Canada. [15] Zhou, Q.Y., Gong, M., Chui, Y.H., and Mohammad, M. 2014. Measurement of rolling shear modulus and strength of cross laminated timber using bending and two-plate shear tests. Wood and Fiber Science, 46(2): 1-11