High Power Programmable DC Power Supplies PVS Series

Similar documents
2015 NEW PRODUCTS CATALOG

Photovoltaic / Solar Array Simulation Solution

Programmable AC Power Source Model 9801

Modular Programmable DC Electronic Load MDL Series

LOW POWER PLA SERIES. PLA Series Brief Profile. Interfaces. Electronic DC Loads

Power Source & Sink. Signal Generation & Analysis. Component Testing. Product Catalog

DC Electronic Loads 8500 series

DC Electronic Loads 8500 Series

Bench LCR Meter Model 891

PROGRAMMABLE DC POWER SUPPLY MODEL 62000H SERIES MODEL 62000H SERIES. Programmable DC Power Supply. Key Features :

MODEL 62000H-S SERIES

MODEL 62150H-600S/1000S PROGRAMMABLE DC POWER SUPPLY (SOLAR ARRAY SIMULATION) Programmable DC Power Supply (Solar Array Simulation) Key Features :

MODEL 62000H S SERIES

Keysight Technologies Photovoltaic / Solar Array Simulation Solution N8937APV (1500 V, 15 kw, 208 VAC) N8957APV (1500 V, 15 kw, 400 VAC) DG8901A SAS

MODEL 62000H-S SERIES

PROGRAMMABLE SWITCH MODE POWER SUPPLIES. Common Features for ALL SPD Models

About B&K Precision. Introduction. History

True RMS Bench Multimeter 5492B

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U

True RMS Bench Multimeter 5492B

Programmable DC Electronic Load

Agilent N8700 Series System DC Power Supplies

Programmable DC Electronic Loads. Series Programmable DC Electronic Loads. Programmable DC electronic loads DC POWER SUPPLIES

5V SERIES DC LOADS 5V SERIES DC LOADS. Key features:

Advanced Test Equipment Rentals ATEC (2832)

True RMS Bench Multimeters 2831E and 5491B

Keysight Technologies N8700 Series System DC Power Supplies

System and Bench Instruments Catalog 2005 Detailed Specifications, Application Briefs and more for:

Looking For A High Power, Low Profile Power Supply? KEPCO. Has More Than One Way To Help Make Your Decision Easier! AN ISO 9001 COMPANY

LAB-AUTO AUTORANGING DC POWER SUPPLY

DC Resistance Meters 2840 Series

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

Agilent E4360 Modular Solar Array Simulators

Agilent N3300 Series DC Electronic Loads

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Advanced Test Equipment Rentals ATEC (2832)

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES. Regenerative Grid Simulator. Key Features

PSB U Series. 5 kw - 15 kw. Programmable Bidirectional DC Power Supplies THE POWER TEST EXPERTS.

Elgar ETS TerraSAS. 1kW-1MW V. Standalone TerraSAS Photovoltaic Simulator

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

AUM FAMILY Programmable DC Power Supplies

True RMS Bench Multimeters 2831E and 5491B

Portable Multi-Channel Recorder Model DAS240-BAT

Arbitrary/Function Waveform Generators 4075B Series

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Agilent E3633A and E3634A DC Power Supplies

Programmable DC Power Supplies Product Catalog Version 3.1. Higher Quality Power Processing

Programmable DC Power Supplies Product Catalog Version 3.5. Higher Quality Power Processing

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES PRELIMINARY. Regenerative Grid Simulator. Key Features :

Sorensen HPD Series 300 W 5 20 A. 300 Watt DC Power Supply with Near-Linear Performance V. with automatic crossover and mode indication

Keysight E4360 Modular Solar Array Simulators

Agilent 34405A Multimeter

Programmable DC Power Supplies Product Catalog Volume Two

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Keysight Technologies N8937APV and N8957APV Photovoltaic Array Simulators N8937APV (15 kw, 208 VAC) N8957APV (15 kw, 400 VAC)

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

by permanent load resistance, autoranging and a low weight. PFC A highly effective power factor corrector Integrated measurement

Keysight N5700 Series System DC Power Supplies

Keysight 34401A Multimeter

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

PROGRAMMABLE AC POWER SOURCE MODEL 61509/61508/61507/ 61609/61608/61607 MODEL 61509/61508/61507/61609/61608/61607

GENERAL PURPOSE POWER SUPPLIES, SPECIAL PURPOSE POWER SUPPLIES, AND ELECTRONIC LOADS SELECTOR GUIDE

Model 61511/61512/61611/61612

Power Supply Selector Guide

Battery Analyzers BA6010 Series

500 W up to 28,800 W 60 V up to 800 V 45 ma up to 2,700 A. Electronic Load ZS

TS Series 3U to 9U Programmable DC Power Supply Rugged Current-Fed Power Processing

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

HMC-T2240. Synthesized Signal Generator, 10 MHz to 40 GHz

PROCUREMENT OF GOODS UNDER OPEN TENDER PROCEDURE

HMC-T2100B. Portable & Battery Operated! OBSOLETE PRODUCT. Portable Synthesized Signal Generator, 10 MHz to 20 GHz

Water Cooled Active Resistance DC Electronic Load

MAGNADC. Programmable DC Power Supplies: 1.5 kw to 2000 kw+ Product Catalog Datasheet (4.0.3) MagnaDC Programmable DC Power Supplies.

NEW PRODUCTS CATALOG 2013

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

Models 31120/31120A/31180/31180A Programmable AC Power Source

IT7600 High Power Programmable AC power supply

Agilent dc Electronic Loads Models N3300A-N3307A

MeasureReady M91/M91-T FastHall Measurement Controller

GEN10-15KW SERIES. LXI ICompliant LAN Class C ) Features. Model Selection Table. Laboratory Power Supplies: 10 ~ 15KW

WRx Series DC Electronic Load Water cooled, Active Resistance Technology

Agilent E3631A Triple Output DC Power Supply

California Instruments BPS Series kva V A / Phase. Overview. High Power AC Source. Expandable Power Levels.

PV200. Why buy the PV200? The most compact I-V curve tracer around.

PROGRAMMABLE AC POWER SOURCE MODEL 61511/61512/61611/61612

Agilent DC Power Analyzer

ARx Series DC Electronic Load Air cooled, Active Resistance Technology

Programmable Linear DC Power Supply

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price

9200 Series, 300 MHz Programmable Pulse Generator

Model 765 Fast Rise Time Pulse Generator

N432A Thermistor Power Meter DATA SHEET

California Instruments RP Series 2000 VA V 3 45 A. General purpose AC power sources

For Safety information, Warranties, and Regulatory information, see the pages behind the Index.

Transcription:

Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient response time characteristics in an industry leading 2U package. These power supplies provide many useful features such as high programming resolution, multiple remote interfaces for test systems, and a built-in SAS (solar array simulator) function to generate PV (photovoltaic) I-V curves. The optional SAS software allows users to consistently reproduce various I-V curves to test a PV inverter s MPPT efficiency. For benchtop applications, this series provides an intuitive user interface with full keypad and rotary knob. System integrators benefit from the standard USB (virtual COM), RS232, GPIB, and LAN interfaces supporting SCPI commands. Free application software and a complete set of LabVIEW drivers are available to reduce programming time and increase productivity. The application software allows users to control the power supply, execute test sequences, or log measurements. It also integrates with Data Dashboard for LabVIEW apps, enabling users to remotely monitor select measurement indicators with ios, Android, or Windows 8 compatible tablets or smart phones. These power supplies are well suited for both bench use and ATE systems integration, R&D, design verification, production test, and high voltage testing. Special Applications In particular, the low-noise characteristic of the makes these instruments ideal for motor inverter testing. When operated with the optional SAS software, these power supplies can be used for solar array testing applications. Model PVS10005 PVS60085 PVS60085MR** Max Output Voltage 1000 V 600 V 600 V Max Output Current 5 A 8.5 A 8.5 A Features & Benefits Compact, high power density, 2U package Output up to 1000 V / 5 A (PVS10005) and 600 V / 8.5 A (PVS60085 & PVS60085MR) Convenient single-phase AC input configuration Bright VFD display High voltage and current resolution of 0.1 mv, 0.1 ma (PVS10005) or 10 mv, 0.1 ma (PVS60085 & PVS60085MR) Fast transient response time of 0.5 ms Adjustable voltage and current slope (rise and fall times) List mode: 9 user-defined programs with up to 100 programmable steps each Built-in SAS function for storage of up to 16 I-V curves with Voc, Isc, Vmp, and Imp parameters and 1024-point table Store up to 100 different instrument settings to internal memory Control up to 30 power supplies from one PC via the RS485 interface Timer-controlled output (1 s to 1000 hrs) Standard USB (virtual COM), RS232, RS485, GPIB and LAN interfaces External analog programming and monitoring interface Extensive protection features: OVP, OCP, OPP, OTP, foldback protection mode, and key-lock function Front to rear airflow allows for efficient cooling in high rack density environments Master/slave mode for up to four units in parallel (20.4 kw total) LabVIEW driver and softpanel for remote control, test sequence generation, and datalogging available Max Output Power 5000 W 5100 W 3000 W **Model PVS60085MR is a multi-ranging supply allowing any combination of the rated voltage and current up to the maximum output power of 3000 W. Technical data subject to change B&K Precision Corp. 2014

Front panel Bright VFD display Protection LED indicators Function keys Numeric keypad Rotary knob Cursor keys Intuitive user interface The numeric keys and rotary knob provide a convenient interface for setting output levels quickly and precisely. Both measured output values and setting values are concurrently displayed on the screen. Additionally, the power supplies provide internal memory for storage of up to 10 different instrument settings that can be set and recalled via both the front panel and remote interfaces. Rear panel RS-232 interface LAN interface GPIB interface Ground chassis Output and remote sense terminal USB interface RS-485 interface External analog control interface Single-phase AC line input Unlike other 5 kw power supplies that need a 3-phase mains connection, this series only requires a single-phase connection, which is easier to wire and much more commonly available than 3-phase AC outlets. 2

Remote control and programming Test system integration These power supplies offer standard USB, RS-232, GPIB, and LAN interfaces to facilitate test system development and integration. The supports SCPI-compliant protocols and come with LabVIEW drivers. Web server interface The models provide a built-in web server that allows users to configure, control, or monitor the basic settings of the power supply from a remote computer using a web browser. Test sequence execution in list mode The list mode feature allows users to program a list of steps to the power supply s internal memory and execute them. A total of 100 steps can be allocated to each internal memory location, up to a maximum of 9 locations. The test sequence can be programmed remotely via the USB, RS-232, GPIB, or LAN interfaces using SCPI commands or with the included application software. Test sequences can be configured for single or repeated execution. Each steps settings include voltage, current, duration, and output status. Analog programming and monitoring interface In addition to front panel and remote interface control, voltage and current values can also be programmed with an analog control signal. The power supplies can be externally controlled from zero to full scale by either voltage source (0-5 V/0-10 V selectable) or resistance ( 0-5 kω/0-10 kω selectable for high voltage models). The analog interface also offers the ability to monitor the output voltage and current, regulation mode (CV or CC), or to indicate the occurrence of a fault condition. Socket and Telnet interface The power supply can be controlled with SCPI commands using a socket or Telnet connection via the Ethernet interface. Application software PC software is provided for front panel emulation, generating and executing test sequences or logging measurement data without the need to write source code. Remote monitoring on ios, Android, or Windows 8 compatible tablets or smart phones via NI Data Dashboard for LabVIEW apps. Quickly develop a custom dashboard consisting of one (smart phone) or several (tablet) indicators, charts, or gauges to monitor your power supply. Log voltage, current, and power values as well as time stamp, CV/CC, and output status. Save and load list files to/from the power supply s internal memory. Create an unlimited number of external list files to be executed from PC memory. Save and recall list files to/from the PC. 3

Flexible configuration Extensive device protection To protect your DUT, the provides several safety features: overvoltage (OVP), overcurrent (OCP), overpower (OPP), and overtemperature (OTP) protection. When a fault occurs, the power supply will turn off the output, sound an alarm, and display an error message. Similarly, with constant voltage-to-constant current (CV-to-CC) or constant current-to-constant voltage (CC-to-CV) foldback protection mode activated, the supply will shut down if load changes force the supply to transition between the two operating modes. The power supply is also able to detect abnormally low or high AC input power and turn the output off when this condition occurs. Multi-unit control In multi-unit control mode, up to 30 units can be daisy chained via RS485 and controlled from one master unit through the USB, GPIB, or LAN interface. Convenient front panel guided calibration Using a 5 ½ digit multimeter, voltage and current parameters can be conveniently calibrated from the front panel via the calibration menu. Master/Slave operation Up to four models with the same rating can be connected in parallel and operate in master/slave mode. The RS-485 interface is used for communication between the master and slave(s). Once configured, the master will automatically search for and detect slave units, and display the voltage and current of the complete system. AC input power cord (Standard) Rackmount kit (Optional) 4

Solar Array Simulation (SAS) Software Option Solar inverter designers need to verify their inverter is capable of delivering the maximum power available from solar modules. The I-V curve of solar cells can be influenced by various weather conditions such as a cloudy day. Combined with the SAS application software, PVS users can easily simulate the I-V curve of different arrays under various irradiance conditions while measuring and validating the effectiveness of the inverter s MPPT algorithm. Features Variety of input parameters (Voc/Isc/Vmp/Imp/FF/FFv/FFi) Monitors and logs real-time voltage, current, power, MPPT efficiency, and average MPPT efficiency Simulate I-V curve under different weather conditions during a day User-definable irradiance profile Generate a custom I-V curve with up to 1,024 data points PV Simulation Solar arrays consist of multiple solar cells characterized by a complex voltage and current profile that is represented in an I-V curve. PV simulation curve Automatically generate the I-V curve of a solar array in the software by specifying open circuit voltage (Voc), short circuit current (Isc), maximum power voltage (Vmp), and maximum power current (Imp) along with fill factor parameters. Generate an I-V curve manually via a 1,024-point voltage and current table with Notepad or MS Excel and load it in the software. The PVS power supply outputs points on the I-V curve in 1 ms intervals to test the inverter s MPPT efficiency. Use any of the software s built-in irradiance profiles or generate your own point-by-point irradiance profile. 5

Specifications Model PVS60085 PVS60085MR PVS10005 Output Rating Output Voltage (1) 0-600 V 0-1000 V Output Current (2) 0-8.5 A 0-5 A Max. Output Power 5100 W 3000 W 5000 W Line Regulation Voltage 60 mv 100 mv Current 4.25 ma 2.5 ma Load Regulation Voltage 60 mv 100 mv Current 8.5 ma 5 ma Ripple and Noise (20 Hz - 20 MHz) Voltage 100 mvrms / 500 mvpp 100 mvrms / 600 mvpp Current 15 ma 10 ma Resolution Programming 10 mv/0.2 ma 0.1 V/0.1 ma Readback 10 mv/0.2 ma 0.1 V/0.1 ma Programming Accuracy Voltage 400 mv 700 mv Current (3) ± (%output + offset) 0.03% + 3.5 ma 0.03% + 2 ma Readback Accuracy ± (%output + offset) Voltage 0.05% + 300 mv 0.05% + 500 mv Current (3) 0.1% + 8.5 ma 0.1% + 5 ma General Transient Response Time (4) 0.5 ms 0.5 ms OVP adjustment Range 5-660 V 5-1100 V OVP Accuracy 6 V 10 V OCP Accuracy 85 ma 50 ma Command Response Time 20 ms 20 ms Efficiency (5) 90% 90% Power Factor 0.99 0.99 Remote Sense Compensation 6 V 10 V Rising Time at Full Load 100 ms 250 ms Rising Time at No Load 100 ms 250 ms Falling Time at Full Load 100 ms 150 ms 250 ms Falling Time at No Load 3000 ms 5000 ms Standard Interfaces Analog Programming, USB, RS485, RS232, GPIB, and Ethernet AC Input (6) 170-265 VAC single phase Rated Frequency 47-63 Hz Maximum Rated Input Power 5800 VA 3500 VA 5800 VA Temperature Ratings Operation (0 C~40 C) Storage (-40 C~85 C) Dimensions ( W H D ) 16.53 x 3.46 x 20.94 (420 x 88 x 532 mm) Weight 32.18 lbs (14.6 kg) Three-Year Warranty Standard Accessories User manual, power cord, test report & certificate of calibration Optional Accessories SASPVS (SAS software), RKPVS (rackmount kit) (1) Minimum voltage is guaranteed to 5V. (2) Minimum current is guaranteed to maximum 0.4% of rated output current. (3) Current accuracy is applied when output power > 0.1% of full power. (4) Time for output voltage to recover within 0.5% of its rated output for a load change 50 100% of rated output current. (5) 90% typical at nominal line and max load. (6) 10% of output de-rated when operating below 190 VAC. 6 v071014