Pulse Timing and Latency Measurements Using Wideband Video Detectors

Similar documents
LB680A Pulse Profiling USB PowerSensor+ Data Sheet

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

LB480A Pulse Profiling USB PowerSensor+ Data Sheet

Keysight Technologies PNA-X Series Microwave Network Analyzers

LadyBug Technologies, LLC LB5926A True-RMS Power Sensor

Pulsed S-Parameter Measurements using the ZVA network Analyzer

MAKING TRANSIENT ANTENNA MEASUREMENTS

LadyBug Technologies, LLC LB5918L True-RMS Power Sensor

Optimizing Averaging for Better Power Measurements

Statistical Pulse Measurements using USB Power Sensors

LB679A CW and Pulse (Modulation) USB PowerSensor+ Data Sheet

Technical Datasheet GT-8550B Series USB Power Sensor 10 MHz to 26.5 GHz

Power Measurement Basics

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Addressing the Challenges of Wideband Radar Signal Generation and Analysis. Marco Vivarelli Digital Sales Specialist

GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals. Copyright 2001 Agilent Technologies, Inc.

Pulsed VNA Measurements:

Agilent PNA Microwave Network Analyzers

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

Keysight Technologies

R&S NRP-Zxx Power Sensors Specifications

Getting Started. MSO/DPO Series Oscilloscopes. Basic Concepts

Amplifier Test Bench Taking performance to a new peak

Understanding New Pulse-analysis Techniques

Agilent PNA Microwave Network Analyzers

Albuquerque, New Mexico

Exercise 2: FM Detection With a PLL

Narrow Pulse Measurements on Vector Network Analyzers

Improving Amplitude Accuracy with Next-Generation Signal Generators

Testing S-Parameters on Pulsed Radar Power Amplifier Modules

Many devices, particularly

Testing with Femtosecond Pulses

Antenna Measurements using Modulated Signals

Design of Class F Power Amplifiers Using Cree GaN HEMTs and Microwave Office Software to Optimize Gain, Efficiency, and Stability

Quick Start Guide for the PULSE PROFILING APPLICATION

Transient Current Measurement for Advance Materials & Devices

IREAP. MURI 2001 Review. John Rodgers, T. M. Firestone,V. L. Granatstein, M. Walter

Keysight Technologies N9051B Pulse Measurement Software X-Series Signal Analyzers. Technical Overview

Using an Arbitrary Waveform Generator for Threat Generation

PERFORMANCE CONSIDERATIONS FOR PULSED ANTENNA MEASUREMENTS

Meeting Measurement Challenges For Low-Power, Pulsed, Or Modulated Light Sources

Introduction. In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed

Test & Calibration Benefits from a New Precision RF/Microwave Calibrator

Model 865-M Wideband Synthesizer

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Keysight Technologies Techniques for Precise Power Measurements in the Field

Data Sheet. RF Power Meter. Taking performance to a new peak

A Product Development Flow for 5G/LTE Envelope Tracking Power Amplifiers, Part 2

Testing Sensors & Actors Using Digital Oscilloscopes

The VSX3622, a 1.5 kw X-Band GaN Power Amplifier for Radar Application

RF Power Amplifiers for Wireless Communications

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

Pulse Measurements. Application Note

8 Hints for Better Spectrum Analysis. Application Note

PN9000 PULSED CARRIER MEASUREMENTS

RF Peak Power Analyzer

Advances in RF and Microwave Measurement Technology

Tips for making accurate rise / fall time measurements for radar signals

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

60 W, DC MHz, 50 V, GaN HEMT for LTE and Pulse Radar Applications. = 25 C) of Demonstration Amplifier

Federal Communications Commission Office of Engineering and Technology Laboratory Division

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

DR-PL-20-MO Pulse Medium Output Voltage Driver Module

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Advanced Test Equipment Rentals ATEC (2832)

APPH6040B / APPH20G-B Specification V2.0

ETSI Standards and the Measurement of RF Conducted Output Power of Wi-Fi ac Signals

Model 855 RF / Microwave Signal Generator

Agilent AN 1275 Automatic Frequency Settling Time Measurement Speeds Time-to-Market for RF Designs

MEASURING HUM MODULATION USING MATRIX MODEL HD-500 HUM DEMODULATOR

Advances in RF and Microwave Measurement Technology

Today s wireless. Best Practices for Making Accurate WiMAX Channel- Power Measurements. WiMAX MEASUREMENTS. fundamental information

Lecture Topics. Doppler CW Radar System, FM-CW Radar System, Moving Target Indication Radar System, and Pulsed Doppler Radar System

Hints. for making. Better. Spectrum Analyzer. Measurements. Application Note

Keysight Technologies Accurate Pulsed Measurements with the PNA Microwave Network Analyzers. Application Note

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

CLOUDSDR RFSPACE #CONNECTED SOFTWARE DEFINED RADIO. final design might vary without notice

Rigol DG1022A Function / Arbitrary Waveform Generator

Agilent Pulsed Measurements Using Narrowband Detection and a Standard PNA Series Network Analyzer

Even as fourth-generation (4G) cellular. Wideband Millimeter Wave Test Bed for 60 GHz Power Amplifier Digital Predistortion.

Understanding RF and Microwave Analysis Basics

Novel laser power sensor improves process control

Time Matters How Power Meters Measure Fast Signals

Agilent Technologies Gli analizzatori di reti della serie-x

Introduction to ixblue RF drivers and amplifiers for optical modulators

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

N9051A Pulse Measurement Software

Fundamentals of Radar Measurements. Primer

A balancing act: Envelope Tracking and Digital Pre-Distortion in Handset Transmitters

R&S FSWP Phase Noise Analyzer Specifications

Many applications. Mismatched Load Characterization for High-Power RF Amplifiers PA CHARACTERIZATION. This article discusses the

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

What the LSA1000 Does and How

High Power RF/Microwave Transistors, Pallets and Amplifiers from Integra Technologies, Inc.

MHz. The package options are ceramic/metal flange and pill package. Package Type: , PN: CGHV14250F, CGHV14250P

Analysis of Complex Modulated Carriers Using Statistical Methods

Anadyne s Next-Gen Detector Log Video Amplifier Foils CW Jamming Threats

HAMEG Programmable Measuring Instruments Series 8100

Microwave & RF Device Characterization Solutions

Data Sheet. Peak, CW & Average. Power Sensors. Taking performance to a new peak

Transcription:

Pulse Timing and Latency Measurements Using Wideband Video Detectors LadyBug Technologies 3317 Chanate Rd. Suite 2F Santa Rosa, CA 95404 ladybug-tech.com 1-866-789-7111 An efficient, accurate, and cost-effective method for making RF signal timing and latency measurements is to use wideband video detectors at the two points within the circuit from which the timing comparison is desired. Pulse Profiling USB power sensors from LadyBug Technologies enable easy measurement of one-shot pulse events and other real-time modulated signals with a real-time, wide bandwidth, calibrated analog detector output signal together with a high speed oscilloscope (see Fig. 1). This feature (option OW2) is available on LadyBug models LB480A and LB680A. Fig. 1. Option OW2 provides a wideband, calibrated analog, negative detector video output signal, 0 to -1 volts. As an example, the latency of a pulsed signal passing through a CREE GaN High Electron Mobility Transistor (HEMT) Power Amplifier for S-band radar application was measured. The test setup is shown in Fig. 2. A pulse signal with a 20% duty cycle and a 2.9 GHz carrier frequency was applied to the input through a coupler that was used to provide access to the input signal. The amplifier operates in

saturated mode to maximize efficiency and provide fast switching speed for pulsed waveforms. The amplifier supplies 12 db of gain in its saturated state. Fig. 2. Pulse Latency Measurement Setup. Connecting a LadyBug LB680A power sensor equipped with the wideband video output to both the input and output of the amplifier and the video out of the sensors to two inputs of an oscilloscope enables the time delay measurement. LadyBug Pulse Profiling software allows temporal measurements of the pulses such as rise and fall times, overshoot, droop, and others at both points in the circuit showing the effects of the amplifier on these parameters.

Fig. 3. Wideband analog video outputs of the two sensors on an oscilloscope. The latency measurement of the two video outputs on an oscilloscope is shown in Fig. 4. With a 2.9 GHz carrier frequency the average delay measured was 8.37 ns. This was measured at the rising edge of the RF pulse just as the signals began rising. Averaging was used to reduce the effect of random noise. Fig. 4. Latency measurement results using an oscilloscope with LadyBug LB680A USB power sensors and option OW2. Multiple measurements of time delay were made at different carrier frequencies. Additionally, multiple measurements of time delay were made at different carrier frequencies. For this amplifier the timing latency drops as the carrier frequency increases. At 2.7 GHz, latency is measured as 8.66 ns, falling to 8.14 ns when the frequency is increased to 3.1 GHz.

Time Interval Analysis of Pulses and Pulse Trains Precise, fast and efficient frequency and Time Interval Analysis (TIA) measurements for a Radar System are essential. Pulsed RF signal time and frequency parameters are easily characterized by time stamping the rising and falling RF pulse envelope edges. For an unmodulated CW pulse, measuring pulse parameters such as Pulse Repetition Interval (PRI) and Pulse Width (PW) are relatively easy to derive from the spectrum display on a spectrum analyzer. Pulse Repetition Frequency (PRF = 1/PRI) lines can be obtained by narrowing the resolution bandwidth (RBW) of the spectrum analyzer. Pulse Width can be determined by measuring the peak of the spectrum trace to one of the first nulls. These measurements can be challenging for more complex radar signals. Using the wideband video detector on a LadyBug power sensor with an oscilloscope provides a viable solution. To gather needed information about a long train of pulses with a low duty cycle the oscilloscope or digitizer used will require a substantial amount of memory to acquire a large set of real-time data. Questions include: When does the pulse turn on and off? When does the next pulse turn on and off relative to the previous pulse? In most radar applications, systems tend to change modes and vary their PW and PRI over time. Without a fast, real-time TIA capability these mode and timing changes would not be seen. One answer: measure the timing of the pulse envelope edges provided by the analog envelope signal from the LadyBug power sensor using an oscilloscope or digitizer. Only the timing of the pulse edges needs to be recorded. For time interval analysis of radar signals, use a wideband video detector and oscilloscope to make measurements and facilitate analysis such as: raw time interval data and frequency vs. time data; RF pulse width (PW) vs. time; RF pulse repetition interval (PRI) vs. time; develop PW and PRI histograms and statistics (min/max, mean, std deviation). Simplifying Predistortion Circuitry System elements affecting the performance of the RF predistortion design are the analog envelope detectors required for generating control signals for the analog or digital control circuitry. One method of simplifying the predistortion circuitry: employ the video detector of a LadyBug peak and average power sensor. This would not be feasible for portable user devices and may not be cost effective for some lower power and lower frequency predistortion applications (L- & S-band). For higher power fixed

applications with the carrier frequencies to 20 GHz, the calibrated video output on the LadyBug power sensor provides a simplifying alternative. The level of the video output is fully calibrated so the absolute amplitude of the PA output is accurately tracked by the video signal. It can then be sampled and fed to the DSP based digital predistortion circuit without the need to pass through a calibration look-up-table (LUT) reducing the feedback latency. Fig. 6. RF Digital Predistortion (DPD) block diagram using signal feedback and feedforward. Fig. 6 shows one predistortion configuration out of a multitude of techniques and designs. Here we have implemented digital predistortion using feedback and feedforward of the analog envelope signals of the RF input and output. Out of the all the different possible configurations for PA predistortion, most require at a minimum an accurate real-time sampling of the output power level. The video detector option OW2 is available on LadyBug models LB480A and LB680A pulse profile, peak and average sensors.

Table 1. Video detector specifications. Option OW2 provides real-time, calibrated detector output capability. This allows viewing of one-shot pulses and other real-time modulated signals by using a high speed oscilloscope to display the detector's analog output. The option OW2 signal is made available on the trigger out (TO) SMB connector (so the TO signal will not be available). Option OW2 requires option 004 and is not available if option 001 is ordered.