DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Similar documents
TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Prolific Systems & Technologies Pvt. Ltd. CORE DETAILS. CENTRE Figure - II L-2 X Y Wt-2

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

PUBLIC POWER CORPORATION ENGINEERING & CONSTRUCTION OF TRANSMISSION PROJECTS DEPARTMENT

Basic Principles and Operation of Transformer

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

Introduction. Centrado leading-edge transformer. Introduction

Transformer Protection

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

DISTRIBUTION TRANSFORMER 11 / kv

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

SECTION VI TECHNICAL SCHEDULES

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

VI 3 - i TABLE OF CONTENTS

EARTHING TRANSFORMER

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

Substation Preventive Maintenance

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

DISTRIBUTION TRANSFORMERS

DISTRIBUTION TRANSFORMER kv

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

TECHNICAL DESCRIPTION ND-387. THREE-PHASE TRANSFORMERS, 150 / 21kV, 40/50MVA AND 20/25 MVA, Dyn1

Electrical Description

General Electricity Company of Libya

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

OIL-IMMERSED ARC-SUPPRESSION COILS

Mechanical Design. Brian Brinson Mechanical Design Manager.

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Pomona, CA May 24 & 25, LTC Applications - Location, Series & Preventative Auto Transformers

Industrial Applications

TMC Transformers TMC

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

SECTION TRANSFORMERS

50-SDMS-01 SPECIFICATIONS FOR

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Distribution and Power Transformers

Company Directive ENGINEERING SPECIFICATION EE SPEC: 5/5. Relating to 11kV Distribution Transformers

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

SPECIFICATION No SS-88/5 630 kva, 30 / 0.4 kv THREE-PHASE TRANSFORMERS WITH ON-LOAD TAP CHANGER

POTENTIAL TRANSFORMER

Cast resin transformers HARMONY TM

On-Load Tap Changer Type M

Transformers Contents Page

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Arc Suppression Coils

No. COA/BHL/2018/293 Dated: REQUEST FOR QUOTATIONS

Transformer Fault Categories

Working Group Members

Transformer Factory Testing

Basic principles and operation of a transformer

Oil-immersed Transformers

PS REV NO: 01 PAGE : 2 OF 22

SECTION : 8.0. Guaranteed Technical Particulars

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

1 SCOPE & INTENT OF SPECIFICATION

Report on investigation of failure of 315 MVA Auto transformer at 400 kv Bawana Substation of Delhi Transco Ltd.(DTL)

SCHEDULE-VII TECHNICAL SPECIFICATIONS. Specification No

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

HOW TO SAFE GUARD THE TRANSFORMER..???

MODERN POWER TRANSFORMER PRACTICE BIBLIOGRAPHY

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

K Factor Power Transformers

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

Technical Specifications

SYRIAN ARAB REPUBLIC MINISTRY OF ELECTRICITY PUBLIC ESTABLISHMENT FOR DISTRIBUTION THE ELECTRICITY (PEDE) SPECIFICATIONS FOR

MESP TECHNICAL SPECIFICATION FOR A 1500V DC RECTIFIER TRANSFORMER

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Liquid-Filled Transformers

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

ELETTROMECCANICA. Since english OIL IMMERSED DISTRIBUTION TRANSFORMERS

Maharashtra State Electricity Distribution Co. Ltd.

86 chapter 2 Transformers

Commissioning Manual Distribution Transformers - Three-phase Oil Filled

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

(

OIL TRANSFORMER HV/LV

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

Power Transformers. TS of Power Transformer 1 1 SCOPE

PROBLEMS on Transformers

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

Transcription:

PART - A : SPECIFIC REQUIREMENTS THIS DATA SHEET IS APPLICABLE FOR IN BOILER A CLIMATIC CONDITIONS PACKAGE 1 DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.71 MTRS. 3 RELATIVE HUMIDITY 74 % 4 MAX. RAINFALL PER DAY 5 LOCATION OF INSTALLATION INDOOR 6 SITE ENVIRONMENT TROPICALIZED, MARINE, WITH PRESENCE OF CORROSIVE FUMES B SYSTEM PARTICULARS 1 PRIMARY SYSTEM LIGHTING - DRY TYPE 1.1 VOLTAGE 0.415 kv ± 10% 1.2 FREQUENCY 50 Hz ± 5 % 1.3 COMBINED VOLTAGE & FREQUENCY ± 10 % VARIATION 1.4 NO. OF PHASES / WIRE 3 PHASE / 3 WIRE 1.5 SYSTEM GROUNDING Solidly Grounded 1.6 FAULT LEVEL 50 ka 3 PH SYMM 2 SECONDARY SYSTEM 2.1 VOLTAGE 0.415 kv 2.2 NO. OF PHASES / WIRE 3 PHASE / 4 WIRE 2.3 SYSTEM GROUNDING SOLIDLY GROUNDED C TECHNICAL PARTICULARS 1 RATING * 2 NO. OF PHASES THREE 3 NO LOAD VOLTAGE RATIO : 0.415 / 0.415 kv PRIMARY/SECONDARY /ANY 4 VECTOR GROUP Dyn11 5 % IMPEDANCE : * 6 TYPE OF COOLING ANAN X:\STD\FORMS\E04-004A_Rev0 REV. 0 PAGE : 1 OF 8

PART - A : SPECIFIC REQUIREMENTS ( CONTD...) C TECHNICAL PARTICULARS ( CONTD..) 7 INSULATION LEVEL a ) FOR IMPULSE TEST (KVP) b ) FOR POWER FREQUENCY HV : - KV, LV : - KV HV : 3 KV, LV : 3 KV WITHSTAND (RMS) 8 TEMPERATURE RISE : a ) WINDING 90 C ABOVE AMBINET TEMPERATURE OF 45 C b ) OIL NOT APPLICABLE 9 ADDITIONAL OUTDOOR BUSHING FOR NEUTRAL EARTHING : a ) FOR PRIMARY b ) FOR SECONDARY c ) EARTH CONDUCTOR SIZE NOT REQUIRED REQUIRED 75 X 10 G.I EARTH STRIP 10 TAP CHANGER : HV SIDE OFF LOAD 11 RANGE OF TAPS / STEPS : +/- 2.5 % IN STEPS OF 2.5 % 12 ON LOAD TAP CHANGER : AUTO & MANUAL NOT APPLICABLE 13 PROTECTIVE BUSHING CT'S : 13.1 HV. SIDE : RATIO : NA ACCURACY CLASS : NA BURDEN : NA 13.2 LV. SIDE : RATIO : NA ACCURACY CLASS : NA BURDEN : NA 13.3 NEUTRAL SIDE: RATIO : NA ACCURACY CLASS : NA BURDEN : NA 14 MOUNTING OF CT's HV. SIDE : NA LV. SIDE : NA NEUTRAL : NA D CONSTRUCTION 1 TERMINAL BOX ARRANGEMENT ; HV & LV OPPOSITE 2 PRIMARY TERMINAL TYPE CABLE BOX WITH DISCONNECTING CHAMBER 2.1 CABLE / CONDUCTOR SIZE : * 3 SECONDARY TERMINAL TYPE CABLE BOX WITH DISCONNECTING CHAMBER FOR 3.1 CABLE / CONDUCTOR / BUS BAR SIZE : * 4 RADIATORS NA 5 PAINTING : EPOXY PAINT SHADE NO. 632 AS PER IS : 5 6 FITTINGS & ACCESSORIES AS PER STD. SPECIFICATION. :44LK5100ESS-04 X:\STD\FORMS\E04-004A_Rev0 REV. 0 PAGE : 2 OF 8

7 BIDIRECTIONAL RAILWHEEL / ROLLER RAIL WHEEL E PERFORMANCE PARTICULARS AS SPECIFIED ELSEWHERE IN FEED DOCUMENT F DRAWING, DATA & TEST AS SPECIFIED ELSEWHERE IN FEED DOCUMENT CERTIICATES G INSPECTION & TESTING AS PER INSPECTION TEST PLAN ATTACHED ELSEWHERE. H NOTES & ADDITIONAL REQUIREMENTS: 1) INSULATION SHALL BE CLASS H WITH TEMPERATURE RISE LIMITED TO CLASS F. * - BOILER VENDOR TO SPECIFY X:\STD\FORMS\E04-004A_Rev0 REV. 0 PAGE : 3 OF 8

PART - B : PERFORMANCE PARTICULARS. THE PARTICULARS MARKED WITH ASTERISK ( * ) SHALL BE GUARANTEED, SUBJECT TO THE TOLERANCE SPECIFIED IN IS - 2026 REF. 44LK5100ESS 004 UNIT 1 NAME OF THE MANUFACTURER. 2 TRANSFORMER DESIGNATION 3 QUANTITY NOS. 4 INSTALLATION 5 RATED KVA AS PER IS - 2026 KVA 6 CONTINUOUS MAXIMUM RATING FOR SITE CONDITIONS SPECIFIED IN PART - A KVA 7 ( * ) NO LOAD VOLTAGE RATIO 8 VECTOR GROUP REFERENCE 9 ( * ) NO LOAD LOSSES AT RATED VOLTAGE * KW 10 ( * ) LOAD LOSSES AT RATED CURRENT, 75 C * KW 11 RESISTANCE VOLTAGE (AT RATED KVA,75 C & 50 Hz) % 12 REACTANCE VOLTAGE (AT RATED KVA,75 C & 50 Hz) % 13 ( * ) IMPEDANCE VOLTAGE ( AT RATED KVA, 75 C & 50 Hz. ) * % 14 RESISTANCE OF WINDINGS, AT 75 C a ) H.V. PER PHASE b ) L.V. PER PHASE OHMS OHMS 15 WINDING INSULATION 16 ZERO PHASE SEQUENCE IMPEDANCE ( ESTIMATED ) % 17 EFFICIENCY ( AT 75 C ) AT FULL LOAD a ) 1.0 P.F % b ) 0.8 P.F. (LAG) % 18 EFFICIENCY ( AT 75 C ) AT 75 % OF FULL LOAD a ) 1.0 P.F % b ) 0.8 P.F. (LAG) % 19 EFFICIENCY ( AT 75 C ) AT 50 % OF FULL LOAD a ) 1.0 P.F % b ) 0.8 P.F. (LAG) % 20 LOAD AT WHICH MAX. EFFICIENCY SHALL OCCUR % FULL LOAD 21 MAXIMUM EFFICIENCY : % X:\STD\FORMS\E04-004A_Rev0 REV. 0 PAGE : 4 OF 8

PART - B : PERFORMANCE PARTICULARS. ( CONTD... ) 22 PERCENTAGE REGULATION AT FULL LOAD : a ) 1.0 P.F. % b ) 0.8 P.F. ( LAG ) % 23 EXCITING CURRENT REFERRED TO PRIMARY, 50 Hz. : a ) 90 % RATED VOLTAGE b ) 100 % RATED VOLTAGE ( NO LOAD CURRENT ) c ) 110 % RATED VOLTAGE AMPS. AMPS. AMPS. 24 POWER FACTOR OF EXCITING CURRENT AT RATED VOLTAGE AND 50 Hz. : 25 TAPPING ON H.V. WINDING a) TYPE OF TAP CHANGER b) TAPPING RANGE WITH STEPS 26 TERMINAL CONNECTION a) TERMINAL BOX ARRANGEMENT ; HV & LV b) PRIMARY TERMINAL TYPE c) CABLE / CONDUCTOR SIZE : d) SECONDARY TERMINAL TYPE e) CABLE / CONDUCTOR / BUS BAR SIZE : f) BUS DUCT TAKE OFF 27 RADIATORS 28 TERMINAL BUSHINGS a) VOLTAGE CLASS b) RATED CURRENT c) IMPULSE WITHSTAND VOLTAGE d) POWER FREQUENCY WITHSTAND VOLTAGE e) CLAREANCE IN AIR f) PHASE TO PHASE g) PHASE TO EARTH h) MINIMUM CREEPAGE/ PROTECTIVE CREEPAGE DISTANCE 29 BUSHING CTs REQUIRED 30 DRY TYPE, CAST RESIN CTs LOATED IN CABLE BOX REQUIRED 31 CT DETAILS a) NUMBER OF CTs REQUIRED b) APPLICATION OF CTs c) NUMBER OF CORES e) CT RATIO f) CLASS OF ACCURACY g) BURDEN h) PARAMETERS FOR Vk, Imag, Rct AND Vct AS PER DATA SHEET X:\STD\FORMS\E04-004A_Rev0 REV. 0 PAGE : 5 OF 8

PART - B : PERFORMANCE PARTICULARS. ( CONTD... ) 32 MAGNETISING INRUSH CURRENT ( PEAK ) UNDER WORSE CONDITIONS OF RESIDUAL MAGNETISM & INSTANT OF SWITCHING : KA. 33 SYMMETRICAL SHORT-CIRCUIT CURRENT (ASSUME INFINITE SOURCE ) : KA. 34 TIME OF WITHSTAND WITHOUT INJURY UNDER MAX. SYMM. SHORT CIRCUIT CONDITION : SECS. 35 THERMAL TIME CONSTANT : HRS. 36 MAX. FLUX DENSITY IN CORE AT RATED K.LINES / VOLTAGE : CM ² 37 CURRENT DENSITY AT RATED LOAD : a ) H.V. WINDING A / MM ² b ) L.V. WINDING A / MM ² 38 TYPE OF WINDING : HIGH VOLTAGE : LOW VOLTAGE : 39 MATERIAL FOR WINDING 40 INSULATION CLASS 41 IMPULSE LEVELS WITH 1.2/50 MICRO-SECOND WAVE FORM : a ) HIGH VOLTAGE. b ) LOW VOLTAGE. KV. KV. 42 POWER FREQUENCY WITHSTAND VOLTAGE a ) HIGH VOLTAGE. b ) LOW VOLTAGE. KV. KV. 43 TYPE OF COOLING. 44 MAXIMUM TEMPERATURE RISE ABOVE AMBIENT TEMP. 44.1 TOP OIL BY THERMOMETER a) FOR ONAN TYPE COOLING b) FOR ONAF TYPE COOLING c) FOR ONWF TYPE COOLING d) FOR OFWF TYPE COOLING 44.2 WINDING BY RESISTANCE METHOD a) FOR ONAN TYPE COOLING b) FOR ONAF TYPE COOLING c) FOR ONWF TYPE COOLING d) FOR OFWF TYPE COOLING 45 COOLING FANS a) NUMBER OF FANS REQUIRED b) RATING OF EACH FAN c) MIN NUMBER OF FANS TO BE IN OPERATION AT FULL LOAD d) WINDING TEMPERATURE AT WHICH FORCED COOLING IS INITIATED X:\STD\FORMS\E04-004A_Rev0 REV. 0 PAGE : 6 OF 8

PART - B : PERFORMANCE PARTICULARS. ( CONTD... ) e) TRANSFORMER DERATING FACTOR AFTER FAILURE OF - ONE COOLING FAN - TWO COOLING FANS - ALL COOLING FANS 46 TOTAL WEIGHT WITH OIL & ACCESSORIES. KG. 47 VOLUME OF OIL FOR COMPLETE FILLING LITRES 48 APPROXIMATE OVERALL DIMENSIONS ( L x W x H ) MM. 49 SIZE ( L x W x H ) & WT. OF LARGEST SHIPPING SECTION MM. & KG 51 CLERANCE a) MINIMUM CLERANCE HEIGHT FOR LIFTING CORE AND MM WINDING FROM TANK b) FREE SPACE REQUIRED AT THE TOP FOR REMOVAL MM OF ACCESSORIES INCLUDING BUSHING 52 WHEELS a) PLAIN ROLLERS / FLANGED WHEELS b) MOVEMENT UNIDIRECTIONAL / BIDIRECTIONAL c) GUAGE d) QUANTITY 53 ENCLOSURE FOR MARSHALLING BOX, COOLING CONTROL CABINET, OLTC PANEL ETC 54 VACUUM WITHSTAND CAPABILITY a) MAIN TANK b) RADIATORS 55 DETAILS OF FITTINGS & ACCESSORIES. a) RATING & DIAGRAM PLATE PROVIDED / NOT PROVIDED / NOT APPLICABLE b) DIAL TYPE MAGNETIC OIL LEVEL GUAGE WITH LOW PROVIDED / NOT PROVIDED / NOT APPLICABLE LEVEL ALARM CONTACTS C) SILICA GEL BREATHER WITH A SEAL & CONNECTING PROVIDED / NOT PROVIDED / NOT APPLICABLE PIPE, IN A TRANSPARENT ENCLOSURE d) CONSERVATOR WITH FILLING HOLE, CAP AND DRAIN PROVIDED / NOT PROVIDED / NOT APPLICABLE VALVE & ISOLATING VALVE FOR CONSERVATOR e) EXPLOSION VENT WITH DIAPHRAGM EQUILISING PIPE PROVIDED / NOT PROVIDED / NOT APPLICABLE f) PLAIN OIL LEVEL INDICATOR WITH MINIMUM MARKING PROVIDED / NOT PROVIDED / NOT APPLICABLE g) DOUBLE FLOAT BUCHHOLZ RELAY PROVIDED / NOT PROVIDED / NOT APPLICABLE h) DIAL TYPE THERMOMETER FOR OIL TEMPERATURE PROVIDED / NOT PROVIDED / NOT APPLICABLE WITH ALARM AND TRIP CONTACTS i) MARSHALLING BOX PROVIDED / NOT PROVIDED / NOT APPLICABLE j) OIL SAMPLING VALVE PROVIDED / NOT PROVIDED / NOT APPLICABLE k) TOP OIL FILTER VALVE PROVIDED / NOT PROVIDED / NOT APPLICABLE l) BOTTOM FILTER VALVE PROVIDED / NOT PROVIDED / NOT APPLICABLE m) DRAIN VALVE WITH PLUG PROVIDED / NOT PROVIDED / NOT APPLICABLE n) PRESSURE RELEIF VALVE PROVIDED / NOT PROVIDED / NOT APPLICABLE p) INSPECTION COVER PROVIDED / NOT PROVIDED / NOT APPLICABLE q) THERMOMETER POCKET (FOR TOP OIL TEMP) PROVIDED / NOT PROVIDED / NOT APPLICABLE X:\STD\FORMS\E04-004A_Rev0 REV. 0 PAGE : 7 OF 8

PART - B : PERFORMANCE PARTICULARS. ( CONTD... ) r) BI DIRECTIONAL ROLLERS PROVIDED / NOT PROVIDED / NOT APPLICABLE s) DRAW EYES PROVIDED / NOT PROVIDED / NOT APPLICABLE t) LIFTING LUGS PROVIDED / NOT PROVIDED / NOT APPLICABLE u) JACKING PADS PROVIDED / NOT PROVIDED / NOT APPLICABLE w) AIR RELEASE VENT PROVIDED / NOT PROVIDED / NOT APPLICABLE x) TWO EARTHING TERMINALS PROVIDED / NOT PROVIDED / NOT APPLICABLE y) IMAGE COIL CT FOR WINDING TEMP WITH DIAL TYPE PROVIDED / NOT PROVIDED / NOT APPLICABLE THERMOMETER I NOTES & ADDITIONAL REQUIREMENTS 1) DRY TYPE TRANSFORMERS SHALL BE PROVIDED WITH CLASS H INSULATION WITH TEMPERATURE RISE LIMITED TO CLASS F. X:\STD\FORMS\E04-004A_Rev0 REV. 0 PAGE : 8 OF 8