Lambda 1050 / 950 UV/Vis/NIR

Similar documents
LAMBDA 800 UV/VIS and 900 UV/VIS/NIR Spectrophotometer Systems

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

Croma Enterprise Cromtech India

instruments Analytical Instruments for Science

Spectro p photomete p r V-700 series

T92+ UV-VIS SPECTROPHOTOMETER

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

Nicolet Evolution 500. UV-Visible Spectrophotometer

SolidSpec-3700 SolidSpec-3700DUV

Lambda X65 series. UV/Vis Simplified for your Lab. Gerlinde Wita October 2015

Oriel Cornerstone 130 1/8 m Monochromator

Cornerstone 260 1/4 m Monochromators

Lab Junior Educational UV-VIS Spectrometer

UV / VIS Spectrophotometer

CHEM Course Outline (Part 14) Absorption Spectroscopy update 2011 For an html version of 2005 notes, click here

1/8 m GRATING MONOCHROMATOR

SP-8001 UV/Visible Spectrophotometer

The FTNIR Myths... Misinformation or Truth

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

Cornerstone 130 1/8 m Monochromators

V-700 series. UV-Visible/NIR Spectrophotometers

MANUAL BMS SPEC5000 Spectrophotometer

Page 1 BIOIMAGER. Spectrophotometers. Toll Free: (855) BIO- IMAG / (855) , E: S:

Czerny-Turner mount Double monochromator Fully symmetrical double beam type

UVS-2800 Spectro UV-VIS Split Beam (PC) is a precise scanning

Spectro UV-VIS Double Beam Research Spectrophotometer UV-VIS Double Beam

Microscope-Spectrometer

Table 8 Overview light sources

Content Spectrophotometers

Operating Manual. Model 721N. Visible Spectrophotometer

Systems & Accessories

Measuring optical filters

MS260i 1/4 M IMAGING SPECTROGRAPHS

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

Tunable KiloArc. Tunable Broadband Light Source.

Visible & UV/Vis Spectrophotometers

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

AvaLight-HAL-S-MINI Tungsten-Halogen Light Source

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

INTERNATIONAL INTERCOMPARISON OF WAVELENGTH SCALE AND PHOTOMETRIC SCALE OF SPECTROPHOTOMETRY LABORATORIES CENAM - NRC - INMETRO - NIST.

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

UV-Vis-NIR Spectrophotometer Quick Start Guide

AvaLight-DHc Full-range Compact Light Source

Oriel MS260i TM 1/4 m Imaging Spectrograph

VWR SPECTROPHOTOMETERS

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

PRODUCT BROCHURE. Affordable Lab Technology

Research Grade Xenon Arc Lamp Sources LH-Series 75 W - 300W

Chemistry Instrumental Analysis Lecture 10. Chem 4631

NATIONAL INSTITUTE OF RESEARCH AND DEVELOPMENT FOR OPTOELECTRONICS

CONTENTS Product Accessory Software V /02 V-5100/UV /04 UV-5100B 05/06

Ensure Optimal Instrument Performance with Genuine Agilent Long-life Deuterium Lamps

BIO SPECTROPHOTOMETER

Miniature Spectrometer Technical specifications

TriVista. Universal Raman Solution

Maya2000 Pro Spectrometer

SpectraPro 2150 Monochromators and Spectrographs

Certified Reference Materials for UV, Visible, NIR and IR Molecular Spectroscopy

Spotlight 150 and 200 FT-IR Microscopy Systems

JETI Specbos Instruments

Symmetrical Czerny-Turner, 75 mm focal length nm nm, depending on configuration (see table)

Spectrophotometer simpler to use and higher in dependability thanks to mounting of a large-size color LCD.

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism

Mini-Chrom TM Monochromators

The CORONA Dryer and Blender

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Hitachi Double Beam Spectrophotometer

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Automated Double Aperture Accessory

Development of a New Reference Spectrophotometer. J.C. Zwinkels, D.S. Gignac

UV/VIS Spectrophotometer

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

The equipment used share any common features regardless of the! being measured. Electronic detection was not always available.

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Gamma Scientific Display Measurement Systems

UV/VIS Spectrophotometer

Pulsed Laser Power Measurement Systems

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

StarBright XLT Optical Coatings

Automated Spectrophotometric Spatial Profiling of Coated Optical Wafers

CUBE. Diode Laser System FEATURES

COLOUR INSPECTION, INFRARED AND UV

Compact High Intensity Light Source

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

SPECTRAL SCANNER. Recycling

UV-VIS-NIR Spectrophotometer

Collector development with IR suppression and EUVL optics refurbishment at RIT

TECHNICAL QUICK REFERENCE GUIDE MANUFACTURING CAPABILITIES GLASS PROPERTIES COATING CURVES REFERENCE MATERIALS

We bring quality to light. Spectro 320 Scanning Spectrometer

Coherent Laser Measurement and Control Beam Diagnostics

ZEISS Spectrometer Modules Compendium of products, electronic components and software solutions

Modular Fourier Transform Infra-Red Spectrometer (FT-IR) Solution

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

1) Solar simulator with I-V measurement setup and software

CUBE. Diode Laser System FEATURES & BENEFITS

Modern Instrumental Methods of Analysis Prof. Dr. J.R. Mudakavi Department of Chemical Engineering Indian Institute of Science, Bangalore

Transcription:

www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Lambda 1050 / 950 UV/Vis/NIR LAMBDA 1050 Choose the LAMBDA 1050 with its triple detector capability for ultra-high UV/Vis/NIR performance for wavelengths up to 3300 nm with extreme sensitivity in the NIR region (800-2500 nm) and higher energy throughput. For applications such as highly reflective and anti-reflective coatings, all types of glass from clear to highly absorbing safety glass, optical filters of all types from the deep UV through the NIR and many more applications requiring the best photo- dynamic range and the widest possible sampling capability. LAMBDA 950 Choose the LAMBDA 950 for ultra-high UV/Vis/NIR performance for wavelengths up to 3300 nm, high- precision measurements, and for applications such as highly reflective and anti-reflective coatings, color correction coatings, bandpass characteristics of UV, Vis and NIR filters, and more. Introduction PerkinElmer UV/Vis and UV/Vis/NIR spectrophotometers are built to the highest ISO- 9001 manufac- turing standards. This document presents confirmed performance specifications based on factory tests. All instruments will meet or achieve better than the confirmed specifications, under normal conditions of use as described in the user manual. The LAMBDATM Series of spectrophotometers is the industry standard for high performance, flexibility and convenience. Each model includes the same range of modular components and snap-in accessories to tackle a range of tough applications. Whatever specifications you require, the LAMBDA Series provides best-in-class accuracy, precision and reproducibility. Technical description and specifications Page 1 of 6

Principle Double beam, double monochromator, ratio recording UV/Vis/NIR spectrophotometers with microcomputer electronics, controlled by DELLTM PC or compatible personal computer. Optical System All reflecting optical system (SiO2 coated) with holographic grating monochromator with 1440 lines/mm UV/Vis blazed at 240 nm and 360 lines/mm NIR blazed at 1100 nm, Littrow mounting, sample thickness compensated detector optics. Beam Splitting System Chopper (46+ Hz, Cycle: Dark/Sample/ Dark/Reference, Chopper Segment Signal Correction). Detector Source Wavelength Range N2 purge required below 185 nm LAMBDA 1050 LAMBDA 950 Photomultiplier R6872 for high energy in the entire UV/Vis wavelength range. Combination of high performance Peltier-cooled InGaAs detector, 2 options: Narrow band covering 860-1800 or wide band covering 860-2500 nm and Peltier- cooled PbS detector for 1800/2500-3300 nm in the NIR wavelength range. Pre-aligned tungsten-halogen and deuterium. Utilizes a source doubling mirror for improved UV/Vis/NIR energy. Photomultiplier R6872 for high energy in the entire UV/Vis wavelength range. High per- formance Peltiercooled PbS detector for the NIR wavelength range. Pre-aligned tungstenhalogen and deuterium. 175 nm - 3300 nm 175nm-3300nm UV/Vis Resolution 0.05 nm 0.05 nm NIR Resolution 0.20 nm 0.20 nm Stray Light At 200 nm 12 g/l KCl USP/DAP method At 220 nm >2A >2A Page 2 of 6

10 g/l NaI ASTM 0.00007 %T 0.00007 %T method At 340 nm 50 mg/l NaNO2 0.00007 %T 0.00007 %T ASTM method At 370 nm 50 mg/l NaNO2 0.00007 %T 0.00007 %T ASTM method At 1420 nm H20 1 cm path 0.00040 %T 0.00040 %T length At 2365 nm CHCl3 1 cm path 0.00050 %T 0.00050 %T length Wavelength ± 0.080 nm ± 0.080 nm Accuracy UV/Vis NIR ± 0.300 nm ± 0.300 nm Wavelength Reproducibility UV/Vis 0.010 nm 0.020 nm (Deuterium lamp lines) NIR (Deuterium 0.040 nm 0.080 nm lamp lines) Standard deviation 0.005 nm 0.005 nm of 10 measurements UV/Vis Standard deviation of 10 measurements NIR 0.020 nm 0.020 nm LAMBDA 1050 LAMBDA 950 Accuracy Double Aperture ± 0.0003 A ± 0.0006 A Method 1 A Double Aperture ± 0.0003 A ± 0.0003 A Method 0.5 A NIST 1930D ± 0.0030 A ± 0.0030 A Filters 2 A NIST 930D Filters ± 0.0030 A ± 0.0030 A 1 A NIST 930D Filters ± 0.0020 A ± 0.0020 A 0.5 A K2Cr2O7-Solution ± 0.0080 A ± 0.0080 A Page 3 of 6

USP/DAP method Linearity Addition of filters UV/Vis at 546.1 nm, 2 nm slit, 1 second integration time At 1.0 A ± 0.0060 A ± 0.0060 A At 2.0 A ± 0.0160 A ± 0.0170 A At 3.0 A ± 0.0050 A ± 0.0200 A NIR At 1.0 A ± 0.0005 A (1200 nm) NIR At 2.0 A ± 0.0010 A (1200 nm) Reproducibility Standard deviation for 10 measurements, 2 nm slit, 1 second 1 A with NIST 0.00016 A 0.00016 A 930D Filter at 546.1 nm 0.3 A with NIST 930D Filter at 546.1 nm 0.00008 A 0.00008 A Range LAMBDA 1050 LAMBDA 950 UV/Vis 8 A 8 A NIR 8 A 6 A Unlimited Unlimited Display Bandpass 0.05 nm - 5.00 nm in 0.01 nm increments UV/Vis range 0.20 nm - 20.00 nm in 0.04 nm increments NIR range Fixed resolution, constant energy or slit programming. 0.05 nm - 5.00 nm in 0.01 nm increments UV/Vis range 0.20 nm - 20.00 nm in 0.04 nm increments NIR range Fixed resolution, constant energy or slit programming. 0.0002 A/ h 0.0002 A/ h Page 4 of 6

Stability After warm-up at 500 nm, 0 A, 2 nm slit, 2 second integration time, peak to peak Baseline Flatness ± 0.0008 A ± 0.0008 A 190 nm - 3100 nm, 2 nm slit 0.20 second UV/Vis, no smoothing applied 0.24 second NIR, no smoothing applied Noise LAMBDA 1050 LAMBDA 950 RMS 2 nm slit, 1 second 0 A and 190 nm 0.00010 A 0.00010 A 0 A and 500 nm 0.00005 A 0.00005 A 2 A and 500 nm 0.00020 A 0.00020 A 4 A and 500 nm 0.00100 A 0.00100 A 6 A and 500 nm 0.00500 A 0.00500 A 0 A and 1500 nm 0.00002 A 0.00004 A 2 A and 1500 nm 0.00010 A 0.00010 A 3 A and 1500 nm, 0.00250 A 0.00300 A PbS (Servo) 0 A and 1500 nm 0.00002 A InGaAs 2 A and 1500 nm InGaAs 0.00010 A 3 A and 1500 nm, Wide Band InGaAs (Servo) 3 A 1500 nm, Narrow Band InGaAs (Servo) Primary Sample Compartment 0.00010 A 0.000025 A 200 mm x 300 mm x 220 mm 200 mm x 300 mm x 220 mm Page 5 of 6

Dimensions (W x D x H) Secondary Sample Compartment Dimensions (W x D x H) Purging Optics Purging Sample Compartment Instrument Dimension (W x D x H) 480 mm x 300 mm x 220 mm 480 mm x 300 mm x 220 mm 1020 mm x 740 mm x 300 mm 1020 mm x 740 mm x 300 mm Instrument Weight ~ 77 kg ~ 77 kg Digital I/O RS 232 C RS 232 C Light Beam 90 mm above the base plate, 120 mm beam separation, 3 mm - 12 mm beam height Instrument Requirements 90 mm above the base plate, 120 mm beam separation, 3 mm - 12 mm beam height Power 90 VAC - 250 VAC, 50/60 Hz; 250 VA Temperature 10 C - 35 C 10 C - 35 C Recommended 10-70% relative humidity, noncondensing Humidity 90 VAC - 250 VAC, 50/60 Hz; 250 VA 10-70% relative humidity, non-condensing www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Page 6 of 6