SCXI MHz Quad 8x1 50 Ω Multiplexer

Similar documents
NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

NI PXI/PXIe-2540 Specifications

Refer to the NI Switches Help at ni.com/manuals for detailed topology information.

NI PXI-2521 Specifications 40-Channel DPST Relay Module

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

NI PXI-2555 Specifications

NI PXI-2557 Specifications

NI PXIe Contents. About These Specifications DEVICE SPECIFICATIONS. 3 GHz Ω Multiplexer (SP16T)

NI PXI-2520 Specifications 80-Channel SPST Relay Module

NI PXI/PXIe-2529 Specifications

NI SCXI Specifications

NI PXI Contents. About These Specifications DEVICE SPECIFICATIONS GHz Dual Transfer Switch 50 Ω Relay Module

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

NI PXI/PXIe-2527 Specifications

NI PXI Contents DEVICE SPECIFICATIONS. RF Attenuator

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

PXI Contents. PXI-2585 Specifications. Topology DEVICE SPECIFICATIONS. 10-Channel Multiplexer

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

USRP Contents. Definitions SPECIFICATIONS. 50 MHz to 2.2 GHz Tunable RF Transceiver

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

USRP Contents. Definitions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

USRP Contents. Definitions SPECIFICATIONS. 10 MHz to 6 GHz Tunable RF Transceiver

CDA Contents. Definitions SPECIFICATIONS. Clock Distribution Device

NI PXI/PXIe Contents. About These Specifications DEVICE SPECIFICATIONS. Quad 2 1 Terminated Multiplexer

PXI Contents. PXI-2584 Specifications DEVICE SPECIFICATIONS. 300 V CAT II, 600 V CAT I Multiplexers

NI PXI-2530 Specifications

High-Speed/Flexible Data-Rate CAN Characteristics 5 VDC

NI PXI/PXIe-2532 Specifications

PXIe Contents SPECIFICATIONS. RF Amplifier

PXIe Contents SPECIFICATIONS. RF Preselector Module

100 MHz Bandwidth, 12-Bit PXI Waveform Generator

NI PXIe-5630 Specifications

1- or 2-Port, High-Speed, Flexible Data Rate PXI CAN Interface Module

NI PXI/PXIe Contents DEVICE SPECIFICATIONS. 40 A Fault Insertion Unit

NI PXI/PXIe Contents DEVICE SPECIFICATIONS. 10 A Fault Insertion Unit

Related Information Refer to the NI Switches Help for detailed topology information.

1- or 2-Port, Software-Selectable PXI CAN Interface Module

PXI Contents SPECIFICATIONS. ±20 V, 40 W PXI Source Measure Unit

Analog Characteristics

PXI Contents. Definitions SPECIFICATIONS. ±100 V, 2 W Precision PXI Source Measure Unit. These specifications apply to the PXI-4132.

DEVICE SPECIFICATIONS NI PXIe Ch, 24-bit, 25.6 ks/s Simultaneous AC LVDT Input Module

PXI Contents SPECIFICATIONS. 1.3 GHz RF Analog Signal Generator

Analog Input. DEVICE SPECIFICATIONS NI PXIe-4300

PXIe Contents SPECIFICATIONS. 250 khz to 20 GHz RF Analog Signal Generator

PXI Contents SPECIFICATIONS. 6.6 GHz RF Analog Signal Generator

PXIe Contents SPECIFICATIONS. 3.3 GHz RF Analog Signal Generator

PXIe Contents. Definitions SPECIFICATIONS. 8.5 GHz Vector Network Analyzer

PXIe Contents. Definitions SPECIFICATIONS. 8.5 GHz Vector Network Analyzer

NI USB Contents DEVICE SPECIFICATIONS. 50 MS/s Bus-Powered USB Oscilloscope

USRP Contents. Definitions SPECIFICATIONS. USRP Software Defined Radio Stand-Alone Device

100-SPST (latching), 50-DPST. Refer to the NI Switches Help at ni.com/manuals for detailed topology information.

NI PXI-2532 Specifications

4-Channel, ±6 V, 500 ma Precision PXI Source Measure Unit

DEVICE SPECIFICATIONS Phase Matrix PXI GHz PXI Vector Signal Analyzer

This document lists the specifications for the NI PXI The PXI-5900 is a differential amplifier.

4-Channel, ±24 V, 150 ma PXI Source Measure Unit

4-Channel ±10 V, 100 ma, Precision PXI Source Measure Unit

16-Bit, 120 MS/s, 12 Channel DC/16 Channel AC Receiver Adapter Module

NI PXIe-5601 Specifications

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

DEVICE SPECIFICATIONS NI PXIe-4302/ Ch, 24-bit, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module

4-Channel ±10 V, 100 ma, Precision PXI Source Measure Unit

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

4-Channel, ±24 V, 150 ma Precision PXI Source Measure Unit

Related Information Refer to the NI Switches Help for detailed topology information.

SPECIFICATIONS PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

Note Using the NI 5751/5751B in a manner not described in this document may impair the protection that the NI 5751/5751B provides.

NI roborio. Contents. Processor SPECIFICATIONS. RIO Device for Robotics

GETTING STARTED GUIDE NI khz to 100 MHz, 50 Ω, AC Coupled RF Receiver Module

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

PXIe Contents SPECIFICATIONS. 2-Channel, 60 V, 1 A PXI Programmable Power Supply. These specifications apply to the PXIe-4112.

PCI Express, 6½-Digit, ±300 V Digital Multimeter Device

NI Channel SPST Electromechanical Relay Module

DEVICE SPECIFICATIONS NI PXIe-4304/ Ch, 24-bit, ±42 V, 5 ks/s or 51.2 ks/s Simultaneous Filtered Data Acquisition Module. ni.

DATASHEET NI Channel, 250 V Sinking Digital Input Module

PXIe Contents SPECIFICATIONS. ±60 V, 3 A System PXI Source Measure Unit. These specifications apply to the PXIe-4138.

PXIe Contents SPECIFICATIONS. ±200 V, 1 A System PXI Source Measure Unit. These specifications apply to the PXIe-4136.

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling

if it is used in a manner not described in the user documentation.

SPECIFICATIONS PXIe Ch (8 ADC), 2 MS/s, bit, Flexible Resolution PXI Analog Input Module

OPERATING INSTRUCTIONS NI Port DeviceNet Module

SCC-CO20 Isolated Current Output Module

PXIe, 6½-Digit, ±300 V, Onboard 1.8 MS/s Isolated Digitizer,PXI Digital Multimeter

NI Channel, Universal Digital Input Module

PXIe, 24-Channel, ±24 V, 50 ma Precision PXI Source Measure Unit

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

2.5 GHz 75 Ω Multiplexer and SPDT Relay Switches

Specifications are typical and valid from -40 C to +85 C unless otherwise noted. Galvanic isolation between channels and to chassis

PCI Contents SPECIFICATIONS. 8-Channel, 12-Bit, 60 MHz PCI Oscilloscope Device

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

is used in a manner not described in the user documentation.

mmwave Transceiver System

6½-Digit, ±300 V, 1.8 MS/s Isolated Digitizer Included, PCI Digital Multimeter Device

Contents. CALIBRATION PROCEDURE NI PXIe-5698

PXIe Contents SPECIFICATIONS. ±200 V, 1 A Precision System PXI Source Measure Unit. These specifications apply to the PXIe-4137.

Transcription:

SPECIFICATIONS SCXI -1193 500 MHz Quad 50 Ω Multiplexer This document lists specifications for the SCXI-1193 multiplexer module. All specifications are subject to change without notice. Visit ni.com/manuals for the most current specifications. Configurations... Quad multiplexers Dual 16x1 multiplexers Single multiplexer Quad 4x1 terminated multiplexers Dual terminated multiplexers Single 16x1 terminated multiplexer Independent RF Performance Characteristics Characteristic impedance (Z 0 )... 50 Ω, nominal Insertion loss DC to 200 MHz... <0.9 db 200 MHz to 500 MHz... <1.6 db 16x1 DC to 200 MHz... <1.2 db 200 MHz to 500 MHz... <1.9 db DC to 200 MHz... <1.4 db 200 MHz to 500 MHz... <2.4 db Typical bandwidth (3 db)... >900 MHz 16x1... >750 MHz... >600 MHz

Figure 1. Typical Insertion Loss 0 0.5 1 Transmission (db) 1.5 2 16x1 2.5 3 2 1.9 0 100 200 300 400 500 600 700 800 900 1000 Frequency (MHz) Figure 2. Typical VSWR 1.8 1.7 1.6 VSWR 1.5 1.4 1.3 1.2 16x1 1.1 1 0 100 200 300 400 500 600 700 800 900 1000 Frequency (MHz) VSWR DC to 200 MHz...<1.4 200 MHz to 500 MHz...<1.8 2 ni.com SCXI-1193 Specifications

16x1 DC to 200 MHz... <1.4 200 MHz to 500 MHz... <1.8 DC to 200 MHz... <1.4 200 MHz to 500 MHz... <1.8 Channel-to-channel skew within each 8-channel bank is less than 100 ps. Only channels from standard topologies are listed in Table 1. Table 1. Propagation Delay (ns) COM CH0 to CH7 CH8 to CH15 CH16 to CH23 CH24 to CH31 0 1.90 to 2.00 2.55 to 2.65 3.75 to 3.85 3.55 to 3.65 1 1.90 to 2.00 2 1.90 to 2.00 2.55 to 2.65 3 1.90 to 2.00 Typical rise time (10% to 90%)... 385 ps 16x1... 460 ps... 550 ps 120 Figure 3. Typical Channel-to-Channel Isolation 100 Source: CH1, unterminated Measured: COM0 CH0, terminated at CH0 80 Isolation (db) 60 40 20 0 0 100 200 300 400 500 600 700 800 900 1000 Frequency (MHz) SCXI-1193 Specifications National Instruments 3

Figure 4. Typical Bank-to-Bank Crosstalk 0 20 Source: COM0 Measured: COM1 CH7, terminated at CH7 CH12, terminated at CH12 40 Crosstalk (db) 60 80 100 120 0 100 200 300 400 500 600 700 800 900 1000 Frequency (MHz) Input Characteristics All input characteristics are DC, AC rms, or a combination unless otherwise specified. Maximum switching voltage...60 VDC, CAT I (channel-to-channel and channel-to-ground) Caution This module is rated for Measurement Category I and intended to carry signal voltages no greater than 60 VDC. This module can withstand up to 800 Vpk transient overvoltage. Do not use this module for connection to signals or for measurements within Categories II, III, or IV. Do not connect to MAINS supply circuits (for example, wall outlets) of 115 or 230 VAC. Maximum switching current...0.5 A (per channel) Maximum carry current...1 A (per channel) Simultaneous channels at maximum current...up to 4 Maximum switching power...10 W (per channel) 4 ni.com SCXI-1193 Specifications

Note National Instruments recommends against switching active RF signals. As a relay actuates, the channel is momentarily unterminated. Some RF sources can be damaged by reflections if their outputs are not properly terminated. Consult your RF source documentation for more information. DC path resistance Initial... <1.0 Ω End of life... 2.0 Ω Path resistance is a combination of relay contact resistance and trace resistance. Contact resistance typically remains low for the life of a relay. At the end of relay life, the contact resistance rises rapidly above 1.0 Ω. Maximum RF carry power... 10 W up to 500 MHz (per channel) Module Load Derating Insertion loss results in power dissipation and heat buildup within the module. Use the graphs in Figure 5 to determine the maximum power dissipated in each active channel. Total RF power dissipation limit... 7 W (valid over the entire ambient operating temperature range) Example 1: Single Multiplexer 1 channel carrying a 10 W signal at 500 MHz From Figure 5C, the dissipated RF power for the signal is 4.2 W. Example 2: Quad Multiplexer 2 channels carrying 5 W signals at 100 MHz, and 2 channels carrying 10 W signals at 150 MHz From Figure 5A, the dissipated RF power for each 5 W, 100 MHz signal is 0.75 W. From Figure 5B, the dissipated RF power for each 10 W, 150 MHz signal is 1.9 W. The total RF power dissipation for all four channels is: 2 (0.75 W) + 2 (1.9 W) = 5.3 W SCXI-1193 Specifications National Instruments 5

Figure 5. Maximum RF Power Dissipation per Channel 5 A. f 100 MHz Dissipated RF Power (W) 4 3 2 1 16x1 0 0 1 2 3 4 5 6 7 8 9 10 Input RF Power (W) 5 B. 100 MHz < f 200 MHz Dissipated RF Power (W) 4 3 2 1 16x1 0 0 1 2 3 4 5 6 7 8 9 10 Input RF Power (W) 5 C. 200 MHz < f 500 MHz Dissipated RF Power (W) 4 3 2 1 16x1 0 0 1 2 3 4 5 6 7 8 9 10 Input RF Power (W) 6 ni.com SCXI-1193 Specifications

Dynamic Characteristics Maximum scan rate... 100 channels/s Expected relay life Mechanical... 50,000,000 cycles Electrical... 300,000 cycles (30 V, 0.3 A, DC resistive) Trigger Characteristics Input trigger Sources... SCXI trigger lines 0 to 7, Front panel, Rear connector Minimum pulse width... 150 ns Front panel input voltage Minimum... -0.5 V V L maximum... +0.7 V V H minimum... +2.0 V Nominal... +3.3 V Maximum... +5.5 V Output trigger Destinations... SCXI trigger lines 0 to 7, Front panel, Rear connector Pulse width... Programmable (1 μs to 62 μs) Front panel nominal voltage... 3.3 V TTL, 8 ma Physical Characteristics Relay type... Electromechanical, latching Relay contact material... Silver palladium and gold I/O connectors... 36 MCX jacks Trigger connectors... 2 SMB jacks SCXI DC power requirement +5 VDC... 50 ma +18.5 VDC to +25 VDC... 170 ma -18.5 VDC to -25 VDC... 170 ma SCXI-1193 Specifications National Instruments 7

Dimensions (W H D)...3.0 17.3 19.8 cm (1.2 6.8 7.8 in.) Weight...960 g (2 lb 2 oz) Environment Operating temperature...0 C to 50 C Storage temperature...-20 C to 70 C Relative humidity...5% to 85% noncondensing Pollution Degree...2 Approved at altitudes up to 2,000 m. Indoor use only. Accessories Visit ni.com for more information about the following accessories. Table 2. RG-316 Cabling Available for the SCXI-1193 Connectors Length Part Number MCX-MCX 0.3 m 188374-0R3 1.0 m 188374-01 MCX-BNC 0.3 m 188375-0R3 1.0 m 188375-01 MCX-SMB 0.3 m 188376-0R3 1.0 m 188376-01 MCX-SMA 0.3 m 188377-0R3 1.0 m 188377-01 50 Ω MCX terminator (1 GHz maximum) 778831-01 8 ni.com SCXI-1193 Specifications

Figure 6. SCXI-1193 Power-On State CH0 CH1 CH2 CH3 COM0 CH4 CH5 CH6 CH7 KA0 KA1 KA2 KA3 KA4 KA5 KA6 KA7 KB0 KB1 KB2 KB3 KB4 KB5 KB6 KB7 KC0 KC1 KD0 KD1 KC2 KC3 KD2 KD3 KC4 KC5 KD4 KD5 KC6 KC7 KB8 KB9 KB10 KB11 KB12 KB13 KB14 KB15 KA8 KA9 KA10 KA11 KA12 KA13 KA14 KA15 CH8 CH9 CH10 CH11 COM1 CH12 CH13 CH14 CH15 SCXI-1193 Specifications National Instruments 9

Figure 7. SCXI-1193 Power-On State (continued) CH16 CH17 CH18 CH19 COM2 CH20 CH21 CH22 CH23 KA16 KA17 KA18 KA19 KA20 KA21 KA22 KA23 KB16 KB17 KB18 KB19 KB20 KB21 KB22 KB23 KC8 KC9 KD6 KD7 KC10 KC11 KD9 KD8 KC12 KC13 KD10 KD11 KC14 KC15 KB24 KB25 KB26 KB27 KB28 KB29 KB30 KB31 KA24 KA25 KA26 KA27 KA28 KA29 KA30 KA31 CH24 CH25 CH26 CH27 COM3 CH28 CH29 CH30 CH31 10 ni.com SCXI-1193 Specifications

Compliance and Certifications Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1 CAN/CSA C22.2 No. 61010-1 Note For UL and other safety certifications, refer to the product label or to the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity EN 55011 (CISPR 11): Group 1, Class A emissions FCC 47 CFR Part 15B: Class A emissions ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note For EMC declarations and certifications, refer to the Online Product Certification section. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: Low-Voltage Directive (safety)... 2014/35/EU Electromagnetic Compatibility Directive (EMC)... 2014/30/EU SCXI-1193 Specifications National Instruments 11

Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste and Electronic Equipment, visit ni.com/environment/ weee. RoHS National Instruments (RoHS) National Instruments RoHS ni.com/ environment/rohs_china (For information about China RoHS compliance, go to ni.com/environment/rohs_china.) Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. 2003 2016 National Instruments. All rights reserved. 373460E-01 Sep16