RLC Software User s Manual

Similar documents
Smart Measurement Solutions. Bode 100. User Manual

Bode 100. User Manual

Ansoft Designer Tutorial ECE 584 October, 2004

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

Figure Main frame of IMNLab.

Core Technology Group Application Note 1 AN-1

USING THE VENABLE WINDOWS SOFTWARE VERSION 4

Study of Inductive and Capacitive Reactance and RLC Resonance

Lab #5 Steady State Power Analysis

AC Circuits INTRODUCTION DISCUSSION OF PRINCIPLES. Resistance in an AC Circuit

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

USING THE VENABLE WINDOWS SOFTWARE VERSION 5.5

Figure AC circuit to be analyzed.

An Introductory Guide to Circuit Simulation using NI Multisim 12

LAB 8: Activity P52: LRC Circuit

A Walk Through the MSA Software Vector Network Analyzer Reflection Mode 12/12/09

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

Equivalent Circuit Determination of Quartz Crystals

EE2210 Laboratory Project 1 Fall 2013 Function Generator and Oscilloscope

Impedance Transformation with Transmission Lines

Lab E5: Filters and Complex Impedance

MicroLab 500-series Getting Started

EK307 Active Filters and Steady State Frequency Response

Resonant Frequency of the LRC Circuit (Power Output, Voltage Sensor)

Experiment 8: An AC Circuit

Activity P52: LRC Circuit (Voltage Sensor)

AC System Monitoring Device

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 10. Electronic Circuits

Measure Low Value Impedance Current Shunt Impedance

Using the V5.x Integrator

Experiment Guide: RC/RLC Filters and LabVIEW

INTRODUCTION TO AC FILTERS AND RESONANCE

SAMPLE: EXPERIMENT 2 Series RLC Circuit / Bode Plot

RigExpert AA-170 Antenna Analyzer (0.1 to 170 MHz) User s manual

Core Technology Group Application Note 6 AN-6

AC Measurements with the Agilent 54622D Oscilloscope

Engineering 3821 Fall Pspice TUTORIAL 1. Prepared by: J. Tobin (Class of 2005) B. Jeyasurya E. Gill

Class #7: Experiment L & C Circuits: Filters and Energy Revisited

EXPERIMENT NUMBER 10 TRANSIENT ANALYSIS USING PSPICE

Use of the LTI Viewer and MUX Block in Simulink

Lab 10 - INTRODUCTION TO AC FILTERS AND RESONANCE

IVCAD VNA Base Load Pull with Active/Hybrid Tuning. Getting Started v3.5

A Walk Through the MSA Software Vector Network Analyzer Transmission Mode 12/18/09


Experiment P45: LRC Circuit (Power Amplifier, Voltage Sensor)

Chapter 12: Electronic Circuit Simulation and Layout Software

RLC Frequency Response

Lab 2: Linear and Nonlinear Circuit Elements and Networks

Getting Started with Qucs

Introduction to PSpice

Quick Start Guide for the PULSE PROFILING APPLICATION

DC and AC Circuits. Objective. Theory. 1. Direct Current (DC) R-C Circuit

3. Apparatus/ Materials 1) Computer 2) Vernier board circuit

v(t) = V p sin(2π ft +φ) = V p cos(2π ft +φ + π 2 )

PXIe Contents CALIBRATION PROCEDURE

1. Hand Calculations (in a manner suitable for submission) For the circuit in Fig. 1 with f = 7.2 khz and a source vin () t 1.

Experiment 2: Transients and Oscillations in RLC Circuits

Series and Parallel Resonant Circuits

Frequency Response Analyzers for Stability Analysis and Power Electronics Performance Testing

EECS40 RLC Lab guide

Lab 1: Basic RL and RC DC Circuits

ECE 201 LAB 6 INTRODUCTION TO SPICE/PSPICE

Experiment 2: Electronic Enhancement of S/N and Boxcar Filtering

( ). (9.3) 9. EXPERIMENT E9: THE RLC CIRCUIT OBJECTIVES

ECE 231 Laboratory Exercise 6 Frequency / Time Response of RL and RC Circuits

Experiment Number 2. Revised: Summer 2013 PLECS RC, RL, and RLC Simulations

MultiSim and Analog Discovery 2 Manual

Exercise 1: Series RLC Circuits

Lab 3: AC Low pass filters (version 1.3)

ET1210: Module 5 Inductance and Resonance

Microwave Circuit Design: Lab 5

EK307 Passive Filters and Steady State Frequency Response

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Fig. 1. NI Elvis System

Manual CBT current preamplifier PA1 and CBT Reader software Version 1.5

PHYS 3322 Modern Laboratory Methods I AC R, RC, and RL Circuits

Solving Simple AC Circuits Using Circuit Impedance Calculation

SIMULATIONS OF LCC RESONANT CIRCUIT POWER ELECTRONICS COLORADO STATE UNIVERSITY. Modified in Spring 2006

Exponential Waveforms

CHAPTER 14. Introduction to Frequency Selective Circuits

Appendix 3 - Using A Spreadsheet for Data Analysis

Lab 3: RC Circuits. Construct circuit 2 in EveryCircuit. Set values for the capacitor and resistor to match those in figure 2 and set the frequency to

M. Conner Name: AP Physics C: RC Circuits Lab

Experiment 2 Determining the Capacitive Reactance of a Capacitor in an AC Circuit

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

LT Spice Getting Started Very Quickly. First Get the Latest Software!

LAB EXERCISE 3 FET Amplifier Design and Linear Analysis

NI Elvis Virtual Instrumentation And Prototyping Board

Resonance. Resonance curve.

Lab 9 Frequency Domain

Laboratory 1: Motion in One Dimension

Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Objectives:

PSM Soft. Features and Functions January PC Software Guide. Getting connected and Communication

Handbook. Antenna Rotator Controller

Crystal Characterisation with the TrewMac TE3001 Analyser

PHYSICS - CLUTCH CH 29: ALTERNATING CURRENT.

Lab #2 First Order RC Circuits Week of 27 January 2015

EXPERIMENT 8: LRC CIRCUITS

Instruction Manual. Model USB Wattmeter

The Series RLC Circuit and Resonance

Transcription:

RLC Software User s Manual Venable Instruments 4201 S. Congress, Suite 201 Austin, TX 78745 512-837-2888 www.venable.biz

Introduction The RLC software allows you to measure the frequency response of RLC circuits using one of the Venable Instruments frequency response analyzers (FRA). You can calibrate your RLC box, run measurements through a range of frequencies, build a theoretical model based on the empirical data, and generate reports. The RLC software is controlled mainly through the RLC Control Panel, which has four components: Setup, Measurement, Model, and Report. Installation 1. Insert the NI-488.2 driver CD from National Instruments and install the driver for your GPIB-USB interface. 2. To test the interface, plug your GPIB-USB to an USB port on your computer (leave the GPIB connector unplugged). 3. In order to check that the driver was installed properly, launch the Getting Started Wizard application from the National Instruments/NI-488.2 program group. Click on Verify your hardware and software installation. The application should report that the NI-488.2 troubleshooting wizard was successfully completed. Hit OK and then exit the application. 4. Plug the GPIB connector to the back of your Venable analyzer. 5. Insert the RLC installation CD and install the software. Please read the following section on how to activate the RLC application. Software Activation The RLC software is protected against illegal copying and use. In order to run, first it must be activated. There are three ways to activate your RLC software: If you have an Internet connection, you may use the "Electronic Registration" button to validate your serial number. This is the fastest and easiest method. If you don't have an Internet connection but you have e-mail access, you can send your site code along with your name, company name, address, phone number, and Venable frequency response analyzer serial number (on the back of the instrument) to authorize@venable.biz. Your site code is shown when you select "Show site code" from the "License" menu. Otherwise, you can call Venable Instruments with your site code.

Setup Tab The Setup tab consists of two sections: hardware, and default plot. In the hardware section, there are four parameters to define: Analyzer: currently the supported FRAs are the Venable models 350, 3120, 3215, and 3225. GPIB interface: if there are more than one GPIB interfaces connected to the computer, this field identifies the interface that is used with the current FRA. GPIB address: the address of the FRA. Reference resistor: this is the value, in Ohms, of the resistor used inside the RLC box to measure current. The Venable RLC boxes use 100 Ohm reference resistors. Figure 1. Setup window In the default plot section you can choose the type of plot that will be used whenever you create a new document. Possible options are Impedance plot and Nyquist plot. If the Automatically use the default type option is checked, you won t be prompted for a plot type every time that you create a new one. Measurement Tab Before measurements can be taken, the system must be calibrated. The purpose of the calibration process is to quantify the parasitic components that are present

in the RLC box. With an estimation of the values of these parasitic elements, the actual measurements of RLC circuits can be corrected to improve accuracy. The parasitic components are usually modeled as two elements: one in series (of inductive nature), and one in parallel (of capacitive nature). Figure 2. Parasitic model The calibration process consists of two steps: an open-circuit sweep, and a closed-circuit sweep. Once the calibration process starts, the RLC software will prompt you to first open and then close the circuit in order to take the respective measurements. Open Circuit Sweep When the circuit is open, the impedance of the parallel parasitic element can be calculated (the impedance of the series element is so much smaller that its effect is negligible in the calculation). Figure 3. Open circuit model

Closed Circuit Sweep After the open-circuit sweep is complete, a closed-circuit sweep is run. In this case, the parallel element can be removed from the equation, and the impedance of the series element can be calculated. Figure 4. Closed circuit model After the open-circuit and closed-circuit sweeps are complete, you can save the calibration data for future use. That way, it is not necessary to re-calibrate before every session of measurements. 1.E+05 90 1.E+04 Open_imp 70 1.E+03 50 Impedance [Ohm] 1.E+02 1.E+01 1.E+00 1.E-01 Closed_phase Open_phase 30 10-10 -30-50 Phase [ ] 1.E-02-70 Closed_imp 1.E-03-90 1.E+03 1.E+04 1.E+05 1.E+06 1.E+07 Frequency [Hz] Figure 5. Example of open and closed circuit impedance and phase plots Once the calibration is done, the system is ready to measure RLC circuits. After sweeping through the frequency range, the software will automatically correct the raw data and create another plot with the tag w/o parasitics. This plot is the result of subtracting the series and parallel parasitic elements from the raw data.

1.E+01 90 Imp with parasitics 70 Imp w/o parasitics 50 Impedance [Ohm] 1.E+00 Phase with parasitics Phase w/o parasitics 30 10-10 -30 Phase [ ] -50-70 1.E-01-90 1.E+03 1.E+04 1.E+05 1.E+06 1.E+07 Frequency [Hz] Figure 6. Uncorrected and corrected plots The parameters related to measurements are in the FRA Settings section: Single point or sweep: a single point measurement is done at a specified frequency. A sweep is a series of measurements taken throughout a range of frequencies, from the start frequency to the stop frequency, and with a resolution of 10 steps per decade. Start and stop frequencies: they define the first and last points in the sweep. In the case of a single point setup, only the start frequency is relevant. Integration time: specifies the length of time over which each sample is taken. There are four possible settings: 10 s, 2.5 s, 0.33 s, and 0.05 s. A slower setting will take longer to run but will produce more precise results. A/C and D/C voltages: they specify the injection voltages. Input coupling: specifies whether the input coupling is A/C or D/C. Limit maximum phase change between data points: without this option, the software will always take 10 data points per frequency decade, regardless of the results. A possible problem arises when a sweep involves a resonant point, where the impedance changes abruptly from one frequency to the next. In this case, you can use this feature to mitigate the problem. If, for example, you set the maximum phase change at 20, the software will adapt its frequency interval so that no two points will be more than 20 apart in phase.

Figure 7. The Measurement tab Modeling Tab The modeling tab is used to create a theoretical model out of the circuit that was measured. You can choose the component type and the data set to model. The available component types are different combinations of a resistor, a capacitor, and an inductor, arranged in parallel or in series. After selecting the component type and data set, the calculated theoretical values for R, L, and C are displayed on the window. You can also override the values of R, L, and C by typing different values in the respective controls. You can create a plot that will represent the theoretical RLC circuit based on the values shown. If you wish to create a model with more than three components, you could create multiple models and combine them in series or in parallel using the math functions. The theoretical values of the circuit components are calculated by attempting to fit the model to the measured data. In the case of components in series, the maximum or minimum values of susceptance (for capacitive or inductive circuits, respectively) are used to calculate the capacitance or inductance. In the case of components in parallel, the maximum or minimum values of reactance (for inductive or capacitive circuits, respectively) are used. In order to more accurately calculate the theoretical model, it is better to sweep through a wide frequency range.

Figure 8. The modeling tab 1.E+02 90 70 50 Impedance [Ohm] 1.E+01 30 10-10 -30 Phase [ ] -50-70 1.E+00-90 1.E+02 1.E+03 1.E+04 1.E+05 1.E+06 Frequency [Hz] Imp_sw eep Imp_model Phase_sw eep Phase_model Figure 9. Example of a measured RC circuit and its derived model

Reporting Tab The RLC application can generate reports in PDF format. The reports include a chart with uncorrected and corrected data, modeling information, and optionally a chart with the open and closed circuit calibration data, and a text version of all the plots in tabular format. Figure 10. Reporting tab Working with Documents, Views, and Data Sets The RLC application can contain multiple documents. A document is a collection of one or more data sets (plots). The data contained in a document is shown to you through a view window. There are four different types of views: Impedance: impedance magnitude and phase versus frequency. Gain: gain magnitude and phase versus frequency. Nyquist: resistance versus reactance. Text: impedance magnitude and phase versus frequency. When the application starts, it creates an empty document and shows an impedance view for that document. You can create new documents and open and save existing documents.

Manipulating Data Set Properties A data set is a collection of data points obtained by running a sweep through a range of frequencies. A document can contain multiple data sets. To select a data set, simply click any part of the curve with the mouse pointer, or use the up and down keys to cycle through the collection of data sets. The properties of a data set can be viewed and edited by selecting Data Set Properties from the View menu. The Data Set Properties dialog shows the current data set number, name, type, and description. You can specify whether the data set should be visible, and whether the description should be shown on the screen. The colors are also editable. The voltage node, current node, and scale factor determine how the impedance is calculated, according to the formula shown on the dialog. For acquired data, the voltage node is by default channel #2, the current node is channel #1, and the scale factor is the negative of the reference resistor (defined in the Setup tab). Figure 11. Data set properties Manipulating Graph Properties The properties related to a graph (view) can be edited by selecting the Graph Properties from the View menu.

Figure 12. Graph settings This window allows you to select the plot type, change the grid color, select whether the graph title and legend are shown, and define the scaling parameters. Working with Slide Bars Slide bars are useful for tracking and displaying data values at a specific frequency, represented by a vertical line, and a description box. To create a slide bar, select Add Slide Bar from the View menu. More than one slide bar may be opened at one time, either from the same or different data sets. Add Slide Bar is not available in a text display window. The bar can be dragged using the mouse pointer (except in Nyquist plots, where only the Left or Right keys may be used), and the box will show the data at the selected frequency. The frequency can also be typed in, and the line will move to that frequency. The information shown on the slide bar window is frequency, impedance magnitude and phase, and calculated values for R and L or C for the equivalent RL or RC circuit. The Equivalent Circuit button determines whether the equivalent circuit is series or parallel. Figure 13. Slidebar example

You can use the left or right keys to move the slide bar between data points taken by the analyzer. The shift+left or shift+right key combinations find the 0 degree, +/-90 degree, or the +/-180 degree phase points if they exist. The ctrl+left or ctrl+right key combinations find the 0 db crossing point if it exists. Math Operations The RLC application can apply math functions to one or two data sets. To do this, select the Math Menu item from the Actions menu. Figure 14. Math menu The possible operations are: add, subtract, multiply, divide, add in parallel, subtract in parallel, invert, negate, and create transfer function. The create transfer function operation divides two plots and shows the result in a new gain/phase view. Table 1. Math functions Operation Name Function Application Add Z = Z 1 + Z 2 Cascading filters Subtract Z = Z 1 - Z 2 Removing series parasitic Multiply Z = Z 1 x Z 2 Combining gain stages Divide Z = Z 1 / Z 2 Add in parallel Z = (Z 1 x Z 2 ) / (Z 1 + Z 2 ) Combining filters Subtract in parallel Z = (Z 1 x Z 2 ) / (Z 1 - Z 2 ) Removing parallel parasitic Invert Y = 1 / Z 1 Impedance to admittance Negate Z = -Z 1 180 phase shift Create transfer function Z = Z 1 / (Z 1 + Z 2 ) Filter attenuation

Appendix - The RLC Box The Venable FRA models 350, 3120, 3215, and 3225 have custom RLC boxes that plug directly into the analyzer in order to minimize parasitics. The following is a schematic of the circuit used in the Venable RLC boxes. Figure 15. RLC Box Schematic