REVAMP2600 Instruction manual

Similar documents
REVAMP2250 Instruction manual

REVAMP2250 Instruction manual

REVAMP4100 Instruction manual

REVAMP4120T Instruction manual

PM7400MKII. Instruction manual

MA120 - MA240 Instruction manual

MANUAL. Champ - 4. Professional quad power amplifier

MANUAL. Champ - One. Audiophile Stereo Power Amplifier

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

IMPORTANT SAFETY INSTRUCTIONS

PREZONE1 Instruction manual

IMPORTANT SAFETY INSTRUCTIONS

User Manual. ia480x Power amplifier

AMIS250P 250w Power Amplifier. Operating Manual. AMIS250P, 250 Watt Power Amplifier

MA30 - MA60 Instruction manual

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

MANUAL PA8250

Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Dual Channel Power Amplifier D2 D3 D4 D5. User Manual & Installation Guide

EPA104/254. User Manual.

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

EPA152/252/502. User Manual.

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

Professional Power Amplifier HORIZON SERIES USER MANUAL. Content

Professional Power Amplifier

IMPORTANT SAFETY INSTRUCTIONS

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

OWNER S MANUAL CPS 1 / CPS 2 CONTRACTOR PRECISION SERIES

WX-1 & WX-3 OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier. WX-1 and WX-3.indd :23:16

H A 6 6 CHANNEL STEREO HEADPHONE AMPLIFIER INSTALLATION AND OPERATION MANUAL

M-300 Mono power amplifier User s guide

Amplifier Series BASIC. Installation & Operations Manual

MANUAL MA200

DCM w Power Amplifier

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

DIGITAL CROSSOVERS AND DSP PROCESSORS

User Manual. MA 240 Mixing amplifier

Boulder W Class A Stereo Power Amplifier

User Manual. MA 21 Two zone mixing amplifier

A 4000 A Owner s Manual HPA HPA A4000 A5000 PROFESSIONAL POWER AMPLIFIER POWER CHANNEL 2 CHANNEL 1 PROFESSIONAL POWER AMPLIFIER POWER CHANNEL 2

USER MANUAL APG DYNAMIC PROCESSORS MATRIX ARRAY SYSTEMS 4000SP 6000SP 9000SP

American Audio. User Instructions. American Audio 4295 Charter Strret Los Angeles Ca Revised 5/01

OWNER S MANUAL CPS 3 / CPS 4 CONTRACTOR PRECISION SERIES

A32. f u l l y b a l a n c e d p o w e r a m p l i f i e r. user guide

MA6480A. Energy-Efficient, Multi-Function 240-Watt Mixing Amplifier with Dual 70/100 V and 4 Ohms Outputs. Features

GUITAR POWER AMPLIFIER U S E R ' S M A N U A L

FEATURES: Affordable, reliable power perfect for DRM Series Passive Loudspeakers, installations, and production audio systems

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

CABINET POWERED MIXING CONSOLE

TOA 900 SERIES POWER AMPLIFIER P-924A

2BSST POWER AMPLIFIER OWNER S MANUAL

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D

E4-130, E4-250 power amplifier. user manual

FreeSpace IZA 250-LZ / 190-HZ TECHNICAL DATA SHEET. integrated zone amplifier. Key Features. Product Overview. Product Information.

User Manual. imix 63 Stereo mixing preamplifier

The ART SLA-2 Studio Linear Amplifier

PROFESSIONAL SMPS STEREO AMPLIFIERS USER GUIDE

PowerMatch PM8500 / 8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

TSA 4-700, TSA 1400, TSA 2200, TSA 4000, TSA 4-300, TSA power amplifier. user manual

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

DPA-1200 ORDERCODE D4180 DPA-2400 ORDERCODE D4181 DPA-3400 ORDERCODE D4182

Integrated mixer amplifier PA-60/120/240

D3400 digital power amplifier. user manual

DX 48 DX 24 DX 12 D X - S e r i e s

User's Manual PS 2/2A LTO R. Version 1.1 Septemper 2005 English

AV30MX-2 Operation Manual

3400 Watt Stereo Power Amplifier

System Power Amplifier (SPA)

POWERED MIXER DIGITAL ECHO EFFECT ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO VOL REPEAT MPM CHANNEL POWERED MIXER OWNER S MANUAL

PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT. PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone. User Manual & Installation Guide

MODEL 3 MONO AMPLIFIER OWNER S MANUAL

FreeSpace IZA 2120-LZ Integrated Zone Amplifier

PLANNING YOUR SYSTEM

EQ-AMP60 60W Mixer Amplifier

3.Avoid spilling liquids or allowing materials to enter the cabinet

E-400 power amplifier. user manual

NE SERIES. ne Models ne800 ne1600 ne2400

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

************* OWNER'S MANUAL STAX1250/2 STAX1800/2 STAX2200/2 STAX1200/4 STAX1600/4 STAX2300/4 STAX2000/1D STAX4000/1D STAX5500/1D

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

AX6220Z/AX6240Z. Energy-Efficient, DSP-Powered and Ethernet/USB-Controlled 1000/900-Watt 70/100 V High-Impedance Power Amplifier.

Primare A33.2 Amplifier User Guide

UA ª 35T II Utility Amplifier OPERATING INSTRUCTIONS

MANUAL MA247 MA247MR

USER MANUAL MG-TA1000 POWER AMPLIFIER

AMC SERIES 30W/60W/120W/250W MIXER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

T-link8. SPLITTER/MIXER T-link8. T-link8

Stereo / Mono. Audio Power Amplifier - 60 W. Introduction. Applications

IP Series DUAL POWER AMPLIFIERS

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

E-800 power amplifier. user manual

E-800 power amplifier. user manual

Professional Stereo Amplifiers

HC SERIES POWER AMPLIFIERS

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

a u d i o p h i l e p r e a m p l i f i e r user guide

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

Q44/Q66 PROFESSIONAL AMPLIFIER OWNER S MANUAL

DigiMod 3000PFC DigiMod 3000PFCsu

Dodecahedron Speaker Set

Transcription:

REVAMP2600 Instruction manual

REVAMP2600 Instruction manual 3 REVAMP2600 MANUAL

4 PROFESSIONAL POWER AMPLIFIER Safety first! Caution! This professional device needs to be installed by qualified personnel only. Please check the carton box for any kind of damage on reception of the goods. In case of a damaged carton, please contact your dealer before opening the carton.!!!! Danger!!!! Exposure to high sound levels may cause a permanent hearing loss. Individuals vary considerably to sound pressure level induced hearing loss but nearly everyone will lose some hearing if exposed to high sound pressure levels for a sufficient amount of time. Therefore it is recommended that all persons exposed to equipment capable of producing high sound pressure levels, such as this amplifier, be protected by hearing protection while installing or operating this unit. Read all documentation before operating your equipment. Keep all documentation for future reference. Save the carton and packing material even if the equipment has arrived in good condition. Should you ever need to ship the unit, use only the original factory packing. Do not spill water or other liquids into or on the unit. Make sure power outlets conform to the power requirements listed on the back of the unit. Do not use the unit if the electrical power cord is frayed or broken. Always operate the unit with the AC ground wire connected to the electrical system ground.

REVAMP2600 Instruction manual 5 Set level controls on amplifiers all the way down during powerup to prevent speaker damage if there are high signal levels at the inputs. Do not connect the inputs / outputs of amplifiers or consoles to any other voltage source, such as a battery, mains source, or power supply, regardless of whether the amplifier or console is turned on or off. Power down & disconnect units from mains voltage before making connections. Do not use the unit near stoves, heat registers, radiators, or other heat producing devices. Do not operate equipment on a surface or in an environment which may distort the normal flow of air around the unit. If the unit is used in an extremely dusty or smoky environment, the unit should be periodically blown free of dust. Do not remove the cover. Removing the cover will expose you to potentially dangerous volt ages. Do not drive the inputs with a signal level higher than that required to drive equipment to full output. Do not run the output of any amplifier back into another input. In case of mal-function this device should be serviced by qualified service personnel only. This unit has NOT been designed for use in mobile applications, such as: mobile discobars, mobile PA systems, Live bands, audio rental systems, CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER-SERVICEABLE PARTS INSIDE SERVICING ONLY FOR QUALIFIED PERSONNEL

6 PROFESSIONAL POWER AMPLIFIER Features 2 rack units high Class H amplifier topology 2 channel amplifier Dynamic output power: 2x840W @ 4Ω Sine wave power per channel: 2x600W @ 4Ω(500 msec) High thermal efficiency Highest possible damping factor Analog power supply with toroidal power transformer Active variable speed cooling fan Low power consumption Integrated Analog Devices digital signal processor (DSP) with easy one button operation: simply push the button to select an operating mode, making this amplifier the ideal multi purpose tool for your applications LF filter for increased stability when using 100 volt transformers on the output, allowing you to use 100 volt speakers as top speakers combined with a standard low impedance subwoofer for example Integrated APC limiter/compressor Intelligent thermal power limiting circuit: limits the output power to a safe limit whenever a thermal overload occurs Balanced XLR and euroblock inputs Unbalanced inputs on RCA with pass through

REVAMP2600 Instruction manual 7 Input level attenuators on all inputs 4-pole Speakon speaker output connectors Euroblock speaker output connectors Extended speaker and amp protection circuits: DC protect, over current protect, over temperature protect, input overload Individual channel mute buttons and versatile LED status indicators This unit has NOT been designed for use in mobile applications, such as: mobile discobars, mobile PA systems, Live bands, audio rental systems, Removable rack-ears Note: the integrated APC limiter will automatically limit the incoming audio signal to avoid overloads. This feature can not be defeated and acts as a lifesaver for your valuable speakers.

8 PROFESSIONAL POWER AMPLIFIER Connections 1 3 4 5 6 2 7 11 13 10 12 8 9 14 1. Channel 2 overload led: when this led lights up, you are overloading the input. Lower the input signal immediately to prevent the amplifier from shutting down. 2. Channel 1 overload led: when this led lights up, you are overloading the input. Lower the input signal immediately to prevent the amplifier from shutting down. 3. Channel 2 input gain setting. Adjust the input gain to the output level of your source. Make sure to avoid the clip led lighting up at the strongest input peak level. 4. Channel 1 input gain setting. Adjust the input gain to the output level of your source. Make sure to avoid the clip led lighting up at the strongest input peak level. 5. DSP selector switch with led indicators: push the button to scroll between the various pre-programmed DSP settings. There are 6 possible DSP settings and 2 available combinations. The settings will be memorized and recalled when the unit is

REVAMP2600 Instruction manual 9 powered up. Full details of the available settings can be found below. 6. Channel 2 speaker output on 2 pole euroblock connector. 7. Channel 1 speaker output on 2 pole euroblock connector. 8. Channel 2 speaker output on speakon connector. Pin 1+ = speaker 2 +, pin 1- = speaker 2 -. 9. Channel 1 and 2 stereo speaker output on speakon connector. Pin 1+ = speaker 1 +, pin 1- = speaker 1 -; Pin 2+ = speaker 2+, pin 2- = speaker 2-. 10. Channel 2 unbalanced input and link cinch connector: connect the line level input signal for channel 2 here. Line level is 0 dbv. Input and link connector are internally connected 1 on 1. 11. Channel 1 unbalanced input and link cinch connector: connect the line level input signal for channel 1 here. Line level is 0 dbv. Input and link connector are internally connected 1 on 1. This connector is also used when DSP mode CH1 SUB CH2 TOP is selected. 12. Channel 2 balanced input on 3 pole euroblock connector. 13. Channel 1 balanced input on 3 pole euroblock connector. This connector is used in bridge mode or when DSP mode CH1 SUB CH2 TOP is selected. 14. Mains inlet: connect the mains power cord here.

10 PROFESSIONAL POWER AMPLIFIER Operation 5 1 2 3 4 6 1 1. Removable rack ears for 19 rack mounting. 2. Power switch: after switching on the power, the power led will light up after approx 1 second. The limit-muted leds will light up for a few seconds to avoid excessive power on pop noise. 3. Power led 4. Channel 1 status led bar and mute switch: when the mute switch is pressed, the orange LIMIT MUTED led will light up. This led will also light up when the internal limiter is activated to avoid the amplifier from being overloaded by high input signals. The CLIP OVERLOAD led indicates that the power amplifier is clipping: reduce the input signal at once whenever this occurs!!! The green SIGNAL - -40dB led will light up when an input signal is present. The red INPUT OVERLOAD indicates that the input is being overloaded. Reduce the incoming signal at once!!! This led will blink when temperature protect is active: in this case the amplifier will automatically reduce the output power to avoid further overheating.

REVAMP2600 Instruction manual 11 5. Channel 2 status led bar and mute switch: when the mute switch is pressed, the orange LIMIT MUTED led will light up. This led will also light up when the internal limiter is activated to avoid the amplifier from being overloaded by high input signals. The CLIP OVERLOAD led indicates that the power amplifier is clipping: reduce the input signal at once whenever this occurs!!! The green SIGNAL - -40dB led will light up when an input signal is present. The red INPUT OVERLOAD indicates that the input is being overloaded. Reduce the incoming signal at once!!! This led will blink when temperature protect is active: in this case the amplifier will automatically reduce the output power to avoid further overheating. 6. DSP setting led display: the leds show which of the DSP settings or combinations have been activated. DSP features and audio signal routing There are 10 possible DSP settings. The settings will be memorized and recalled when the unit is powered up. 3 of these settings are meant for low impedance use, the other ones are for 100 volt use or a combination of low impedance and 100 volt.

12 PROFESSIONAL POWER AMPLIFIER A. LOW impedance applications 1. NORMAL STEREO (no led): default setting for normal stereo operation. 2. CH1 SUB + CH2 TOP (led 1): frequencies below 100 Hz are sent to the sub channel (CH1). Frequencies above 100 Hz are sent to the top channel (CH2). Filter slope is fixed: 12 db/oct or second order Butterworth characteristic. Audio signal from input 1 is used. 3. CH 1 linked CH 2 (led 4): Both output channels will amplify the signal from the CH1 input. B. 100V applications 4. CH1 TRAFO + CH2 full range (led 2): channel 1 is optimized for transformer loads, channel 2 is optimized for low impedance applications. 5. CH1 SUB + CH2 TRAFO TOP (led 1 + led 3): frequencies below 100 Hz are sent to the sub channel (CH1). Frequencies above 100 Hz are sent to the top channel (CH2). Filter slope is fixed: 12 db/oct or second order Butterworth characteristic. Channel 2 is optimized for transformer loads. Channel 1 input is sent to output 1, channel 2 input to channel 2. 6. CH1 TRAFO + CH2 TRAFO (led 2 + led 3): both channels are optimized for transformer loads. 7. CH1 TRAFO linked CH2 full range (led 2 + led 4): channel 1 is optimized for transformer loads, channel 2 is optimized for low

REVAMP2600 Instruction manual 13 impedance applications. The input signal from channel 1 is used for both channels. 8. CH1 full range linked CH2 TRAFO (led 3 + led 4): channel 1 is optimized for low impedance full range loads, channel 2 is optimized for low transformer loads (100 volt applications). The input signal from channel 1 is used for both channels. 9. CH1 TRAFO linked CH2 TRAFO (led 2 + led 3 + led 4): channel 1 and 2 are optimized for transformer loads. The input signal from channel 1 is used for both channels. 10. CH1 SUB linked CH2 TRAFO TOP (led 1 + led 3 + led 4): frequencies below 100 Hz are sent to the sub channel (CH1). Frequencies above 100 Hz are sent to the top channel (CH2). Filter slope is fixed: 12 db/oct or second order Butterworth characteristic. The input signal from channel 1 is used for both channels.

14 PROFESSIONAL POWER AMPLIFIER!!! IMPORTANT!!! This amplifier relies on convectional and active cooling. In normal situations, overheating will not occur. The unit can be built in a 19 inch rack system, but it is forbidden to block the ventilation holes provided. Therefore, it is absolutely necessary to allow at least one free rack space or 44 mm above and beneath the amplifier. Make sure the ambient temperature is between 0 and 40 C. Operating the unit beyond its normal limits will result in excessive internal temperature. Power amplifiers are hard workers, and their behaviour is similar to human beings. In extreme conditions, human beings are not able to perform efficiently. This also applies to amplifiers. It is generally a bad idea to mount multiple heat generating units such as amplifiers in the same rack. If necessary, use an additional forced ventilation system in your mounting rack. The mains fuse is located inside the unit. When the fuse is broken, replace it with a fuse of the same current and voltage rating: 10 AT/250V. For qualified personnel only! This unit has NOT been designed for use in mobile applications, such as: mobile discobars and DJ setups, mobile PA systems, Live bands, audio rental systems, Use it in fixed installations only.

REVAMP2600 Instruction manual 15 Technical specifications Dynamic output power Sine wave power per channel Minimum output load impedance CH1 and CH2 Input connections Input sensitivity Input impedance S/N ratio THD ch. 1/2 Frequency response 840 W @ 4 Ω 600 W @ 4 Ω (500 msec) 4 Ω 2 x balanced euroblock, 2 x balanced XLR, 4 x unbalanced cinch with pass through 0 dbv / 1V 22 kω > 98 db A weighted < 0.05% @ 100 W / 4 Ω /1 khz A weighted 10 24 khz + 0 / -3 db Built-in DSP yes Protection circuits over current, over temperature, DC offset, AC and DC over- and undervoltage Channel separation > 67 db @ 1 khz Damping factor > 60 all channels APC sytem Power amp topology Power supply Cooling Max power consumption internal compressor and clip limiter class H toroidal transformer forced 1840W Operating temperature range 0 to 40 C Mains operating voltage 230VAC/50-60Hz Dimensions Net weight Gross weight 483 x 88 x 332 mm (including rack ears) 12.1 kg 14.7 kg

16 PROFESSIONAL POWER AMPLIFIER

REVAMP2600 Instruction manual 17

18 PROFESSIONAL POWER AMPLIFIER

developed by Audioprof nv Industriepark Brechtsebaan 8 bus 1 2900 Schoten - Belgium Company names, product names and trademarks are property of their respective owners. Apart-Audio specifications are subject to change without notice.