Optical fiber Fabry-Perot interferometer cavity fabricated by femtosecond laser micromachining and fusion splicing for refractive index sensing

Similar documents
Optical RI sensor based on an in-fiber Bragg grating. Fabry-Perot cavity embedded with a micro-channel

Fiber-optic Michelson Interferometer Sensor Fabricated by Femtosecond Lasers

Bidirectional Bend Sensor Employing a Microfiber-Assisted U-Shaped Fabry-Perot Cavity

Thin-Core-Fiber-Based Long-Period Fiber Grating for High-Sensitivity Refractive Index Measurement

NUTC R203. Miniaturized Fiber Inline Fabry-Pérot Interferometer for Chemical Sensing. Tao Wei and Hai Xiao

Microfiber-Based Inline Mach Zehnder Interferometer for Dual-Parameter Measurement

Bent-fiber intermodal interference based dualchannel fiber optic refractometer

High sensitivity SMS fiber structure based refractometer analysis and experiment

Supplementary Figures

Magnetic Field Sensing Based on Magnetic-Fluid-Clad Fiber-Optic Structure With Up-Tapered Joints

Miniature fiber optic pressure and temperature sensors

CHIRPED FIBER BRAGG GRATING (CFBG) BY ETCHING TECHNIQUE FOR SIMULTANEOUS TEMPERATURE AND REFRACTIVE INDEX SENSING

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Cascaded Photonic Crystal Fiber Interferometers for Refractive Index Sensing

Optical fiber refractometry based on multimode interference

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Wavelength and bandwidth-tunable silicon comb filter based on Sagnac loop mirrors with Mach- Zehnder interferometer couplers

Title: Laser marking with graded contrast micro crack inside transparent material using UV ns pulse

SIMULTANEOUS INTERROGATION OF MULTIPLE FIBER BRAGG GRATING SENSORS FOR DYNAMIC STRAIN MEASUREMENTS

Research Article Optical Coupling Structures of Fiber-Optic Mach-Zehnder Interferometers Using CO 2 Laser Irradiation

1. Introduction. Manuscript received Month XX,XX.. Aston Institute of Photonic Technologies, Aston University, Birmingham, UK, B4 7ET 2

Wavelength spacing tenable capability of optical comb filter using Polarization Maintaining Fiber

Recent Developments in Fiber Optic Spectral White-Light Interferometry

Optical Fibre-based Environmental Sensors Utilizing Wireless Smart Grid Platform

Ultra-short distributed Bragg reflector fiber laser for sensing applications

OPTICAL fiber sensors have been utilized in a variety of

Sensitivity enhancement of Faraday effect based heterodyning fiber laser magnetic field sensor by lowering linear birefringence

Investigation on Periodically Surface- Corrugated Long-Period Gratings Inscribed on Photonic Crystal Fibers

Realization of Polarization-Insensitive Optical Polymer Waveguide Devices

Shaping ultrafast laser inscribed optical waveguides using a deformable mirror

Research Article Research on Fused Tapered Photonic Crystal Fiber Sensor Based on the Method of Intermittent Cooling

ADVANCES in NATURAL and APPLIED SCIENCES

Numerical simulation of a gradient-index fibre probe and its properties of light propagation

Verifying an all fused silica miniature optical fiber tip pressure sensor performance with turbine engine field test

Investigation of ultrasmall 1 x N AWG for SOI- Based AWG demodulation integration microsystem

Novel fiber Bragg grating fabrication system for long gratings with independent apodization and with local phase and wavelength control

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

Simultaneous strain and temperature fiber grating laser sensor based on radio-frequency measurement

Microring-resonator-based sensor measuring both the concentration and temperature of a solution

Temperature-Independent Torsion Sensor Based on Figure-of-Eight Fiber Loop Mirror

Modification of the Optical Performance of Fiber Bragg Gratings Using Femtosecond Laser Micromachining

Intensity-modulated and temperature-insensitive fiber Bragg grating vibration sensor

Fabrication of microstructures on photosensitive glass using a femtosecond laser process and chemical etching

Femtosecond fiber laser direct writing of optical waveguide in glasses

Bragg and fiber gratings. Mikko Saarinen

Plane wave excitation by taper array for optical leaky waveguide antenna

Development of a High Sensitivity DFB Fibre Laser Hydrophone Work in Progress at National University of Singapore

Ratiometric Wavelength Monitor Based on Singlemode-Multimode-Singlemode Fiber Structure

New Waveguide Fabrication Techniques for Next-generation PLCs

ONE of the technical problems associated with long-period

RADIO-OVER-FIBER TRANSPORT SYSTEMS BASED ON DFB LD WITH MAIN AND 1 SIDE MODES INJECTION-LOCKED TECHNIQUE

VCSEL-powered and polarization-maintaining fiber-optic grating vector rotation sensor

Channel wavelength selectable singleõdualwavelength erbium-doped fiber ring laser

Multiwavelength Single-Longitudinal-Mode Ytterbium-Doped Fiber Laser. Citation IEEE Photon. Technol. Lett., 2013, v. 25, p.

Highly sensitive silicon microring sensor with sharp asymmetrical resonance

Optical MEMS pressure sensor based on a mesa-diaphragm structure

Analysis of the Tunable Asymmetric Fiber F-P Cavity for Fiber Strain Sensor Edge-Filter Demodulation

Optics Communications

Diffractive optical elements for high gain lasers with arbitrary output beam profiles

High-power All-Fiber components: The missing link for high power fiber lasers

Infrared broadband 50%-50% beam splitters for s- polarized light

Fiber Optic Pressure Sensor using Multimode Interference

Optical nanofiber coupler sensors operating in the cut-off wavelength region

S-band gain-clamped grating-based erbiumdoped fiber amplifier by forward optical feedback technique

Coherent beam transformations using multimode waveguides

Ring cavity tunable fiber laser with external transversely chirped Bragg grating

FIVE-PORT POWER SPLITTER BASED ON PILLAR PHOTONIC CRYSTAL *

Dependence of stimulated Brillouin scattering in pulsed fiber amplifier on signal linewidth, pulse duration, and repetition rate

An Optical Characteristic Testing System for the Infrared Fiber in a Transmission Bandwidth 9-11μm

Single-photon excitation of morphology dependent resonance

Design and Analysis of Resonant Leaky-mode Broadband Reflectors

Non-intrusive refractometer sensor

Design of Vibration Sensor Based on Fiber Bragg Grating

Frequency-estimation-based signal-processing algorithm for white-light optical fiber Fabry Perot interferometers

A tunable and switchable single-longitudinalmode dual-wavelength fiber laser with a simple linear cavity

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

Bragg gratings in multimode optical fibres and their applications

Compact two-mode (de)multiplexer based on symmetric Y-junction and Multimode interference waveguides

Miniature all-silica optical fiber pressure sensor with an ultrathin uniform diaphragm

IN RECENT years, tremendous progress has been made in

A miniature all-optical photoacoustic imaging probe

A direction Detective Asymmetrical Twin-core Fiber Curving Sensor

To generate a broadband light source by using mutually injection-locked Fabry-Perot laser diodes

Optical Communications and Networking 朱祖勍. Sept. 25, 2017

Lecture 6 Fiber Optical Communication Lecture 6, Slide 1

DC Index Shifted Dual Grating Based Superstructure Fiber Bragg Grating as Multichannel FBG and Multiparameter Sensor

Novel All-Fiber Band Pass Filter and Multimode-Single-mode Converter for Interconnection Between Multimode Fiber and Single Mode Fiber Network

1272. Phase-controlled vibrational laser percussion drilling

Immersed transparent microsphere magnifying sub-diffraction-limited objects

A novel tunable diode laser using volume holographic gratings

Structured Fiber Bragg Gratings for Sensing Applications

Photonic Crystal Slot Waveguide Spectrometer for Detection of Methane

CHAPTER 7. Waveguide writing in optimal conditions. 7.1 Introduction

Fabrication and Characterization of Photonic Devices Directly Written in Glass Using Femtosecond Laser Pulses

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

Integrated into Nanowire Waveguides

OPTICAL FIBER-BASED SENSING OF STRAIN AND TEMPERATURE

Electronically tunable fabry-perot interferometers with double liquid crystal layers

Optical signal processing for fiber Bragg grating based wear sensors

Transcription:

Optical fiber Fabry-Perot interferometer cavity fabricated by femtosecond laser micromachining and fusion splicing for refractive index sensing C. R. Liao, T.Y. Hu, and D. N. Wang * The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China * eednwang@polyu.edu.hk Abstract: We demonstrate a fiber in-line Fabry-Perot interferometer cavity sensor for refractive index measurement. The interferometer cavity is formed by drilling a micro-hole at the cleaved fiber end facet, followed by fusion splicing. A micro-channel is inscribed by femtosecond laser micromachining to vertically cross the cavity to allow liquid to flow in. The refractive index sensitivity obtained is ~994 nm/riu (refractive index unit). Such a device is simple in configuration, easy for fabrication and reliable in operation due to extremely low temperature cross sensitivity of ~4.8 10 6 RIU/ C. 2012 Optical Society of America OCIS codes: (320.7090) Ultrafast laser; (060.2370) Fiber optics sensors; (120.0120) Instrumentation, measurement, and metrology. References and links 1. Z. X. Gao, A. Adnet, Z. Zhang, F. G. Sun, and C. P. Grover, Monitoring changes in the refractive index of gases by means of a fiber optic Fabry-Perot interferometer sensor, Sensors Actuat. A-Phys. 118, 117 182 (2005). 2. P. Domachuk, I. C. M. Littler, M. Cronin-Golomb, and B. J. Eggleton, Compact resonant integrated microfluidic refractometer, Appl. Phys. Lett. 88(9), 093513 (2006). 3. T. Wei, Y. Han, Y. Li, H. L. Tsai, and H. Xiao, Temperature-insensitive miniaturized fiber inline Fabry-Perot interferometer for highly sensitive refractive index measurement, Opt. Express 16(8), 5764 5769 (2008). 4. J. Villatoro, V. Finazzi, G. Coviello, and V. Pruneri, Photonic-crystal-fiber-enabled micro-fabry-perot interferometer, Opt. Lett. 34(16), 2441 2443 (2009). 5. J. Ma, J. Ju, L. Jin, W. Jin, and D. Wang, Fiber-tip micro-cavity for temperature and transverse load sensing, Opt. Express 19(13), 12418 12426 (2011). 6. M. S. Ferreira, L. Coelho, K. Schuster, J. Kobelke, J. L. Santos, and O. Frazão, Fabry-Perot cavity based on a diaphragm-free hollow-core silica tube, Opt. Lett. 36(20), 4029 4031 (2011). 7. Z. Ran, Y. J. Rao, J. Zhang, Z. Liu, and B. Xu, A miniature fiber-optic refractive-index sensor based on lasermachined Fabry-Perot interfermmeter tip, J. Lightwave Technol. 27(23), 5426 5429 (2009). 8. H. Y. Choi, G. Mudhana, K. S. Park, U.-C. Paek, and B. H. Lee, Cross-talk free and ultra-compact fiber optic sensor for simultaneous measurement of temperature and refractive index, Opt. Express 18(1), 141 149 (2010). 9. K. Mileńko, D. J. Hu, P. P. Shum, T. Zhang, J. L. Lim, Y. Wang, T. R. Woliński, H. Wei, and W. Tong, Photonic crystal fiber tip interferometer for refractive index sensing, Opt. Lett. 37(8), 1373 1375 (2012). 10. Z. L. Ran, Y. J. Rao, W. J. Liu, X. Liao, and K. S. Chiang, Laser-micromachined Fabry-Perot optical fiber tip sensor for high-resolution temperature-independent measurement of refractive index, Opt. Express 16(3), 2252 2263 (2008). 11. K. M. Davis, K. Miura, N. Sugimoto, and K. Hirao, Writing waveguides in glass with a femtosecond laser, Opt. Lett. 21(21), 1729 1731 (1996). 12. W. J. Chen, S. M. Eaton, H. Zhang, and P. R. Herman, Broadband directional couplers fabricated in bulk glass with high repetition rate femtosecond laser pulses, Opt. Express 16(15), 11470 11480 (2008). 13. Y. Kondo, K. Nouchi, T. Mitsuyu, M. Watanabe, P. G. Kazansky, and K. Hirao, Fabrication of long-period fiber gratings by focus irradiation of infrared femtosecond laser pulses, Opt. Lett. 24(10), 646 648 (1999). 14. S. J. Mihailov, C. W. Smelser, P. Lu, R. B. Walker, D. Grobnic, H. Ding, G. Henderson, and J. Unruh, Fiber Bragg gratings made with a phase mask and 800-nm femtosecond radiation, Opt. Lett. 28(12), 995 997 (2003). 15. S. J. Liu, L. Jin, W. Jin, D. N. Wang, C. R. Liao, and Y. Wang, Structural long period gratings made by drilling micro-holes in photonic crystal fibers with a femtosecond infrared laser, Opt. Express 18(6), 5496 5503 (2010). 16. M. Park, S. Lee, W. Ha, D. K. Kim, W. Shin, I. B. Sohn, and K. Oh, Ultracompact intrinsic micro air-cavity fiber Mach-Zehnder Interferometer, IEEE Photon. Technol. Lett. 21(15), 1027 1029 (2009). (C) 2012 OSA 24 September 2012 / Vol. 20, No. 20 / OPTICS EXPRESS 22813

17. Y. Wang, M. W. Yang, D. N. Wang, S. J. Liu, and P. X. Lu, Fiber in-line Mach-Zehnder interferometer fabricated by femtosecond laser micromachining for refractive index measurement with high sensitivity, J. Opt. Soc. Am. B 27(3), 370 374 (2010). 18. J. Yang, L. Jiang, S. Wang, Q. Chen, B. Li, and H. Xiao, Highly sensitive refractive index optical fiber sensors fabricated by a femtosecond laser, IEEE Photonics J. 3(6), 1189 1197 (2011). 19. H. Y. Fu, K. M. Zhou, P. Saffari, C. B. Mou, L. Zhang, S. L. He, and I. Bennion, Microchanneled chirped fiber Bragg grating formed by femtosecond laser aided chemical etching for refractive index and temperature measurements, IEEE Photon. Technol. Lett. 20(19), 1609 1611 (2008). 20. X. Fang, C. R. Liao, and D. N. Wang, Femtosecond laser fabricated fiber Bragg grating in microfiber for refractive index sensing, Opt. Lett. 35(7), 1007 1009 (2010). 21. V. Bhatia and A. M. Vengsarkar, Optical fiber long-period grating sensors, Opt. Lett. 21(9), 692 694 (1996). 22. J. F. Ding, A. P. Zhang, L. Y. Shao, J. H. Yan, and S. L. He, Fiber-taper seeded long-period grating pair as a highly sensitive refractive index sensor, IEEE Photon. Technol. Lett. 17(6), 1247 1249 (2005). 23. R. Jha, J. Villatoro, G. Badenes, and V. Pruneri, Refractometry based on a photonic crystal fiber interferometer, Opt. Lett. 34(5), 617 619 (2009). 24. Z. B. Tian, S. S. H. Yam, and H. P. Loock, Refractive index sensor based on an abrupt taper Michelson interferometer in a single-mode fiber, Opt. Lett. 33(10), 1105 1107 (2008). 1. Introduction Optical fiber Fabry-Perot interferometer (FPI) cavity has been attractive for many sensor applications owing to its miniature size, in-line structure, linear response, high sensitivity and convenient reflection mode of detection [1 10]. To enable effective refractive index (RI) sensing, the optical fiber FPI should be constructed into a tip device for flexible liquid immersion or built with an open micro-cavity to allow liquid to flow in. In such schemes, the conventional single mode fiber (SMF) needs to be incorporated with in-fiber mirrors [7], or spliced with a section of photonic crystal fiber [8, 9]. However, these fabrication methods are rather complicated or with relatively high cost. In recent years, near-ir femtosecond (fs) laser has been widely used for fabricating photonic devices in transparent materials such as bulk glasses [11, 12] and different types of optical fibers [13 15]. Many micro-cavities have been fabricated in optical fiber by using fs laser micromachining and operated as fiber in-line interferometers, such as FPIs [3, 7, 10] and Mach-Zehnder interferometers (MZIs) [16 18]. However, such fiber in-line interferometers, directly fabricated by fs laser ablation, usually exhibit rather rough cavity surface and poor mechanical strength. In this paper, a fiber in-line FPI cavity fabricated by using fs laser micromachining together with fusion splicing is presented for refractive index (RI) sensing. The FPI cavity is formed by drilling a micro-hole at the end facet of SMF, followed by fusion splicing, and finally inscribing a micro-channel by fs laser micromachining to vertically cross the cavity and allow the RI liquid to flow in. Such a RI sensor is simple in structure, easy for fabrication and reliable in operation. The RI sensitivity obtained is ~994nm/RIU with extremely low temperature cross-sensitivity of ~4.8 10 6 RIU/ C. 2. Operation principle of the system Figure 1 shows the schematic diagram of the FPI sensor system proposed, in which a hollow sphere with vertical opening serves as the FP cavity. The incident light beam along the SMF is reflected by the two surfaces of the sphere respectively and recombined in the fiber core, resulting in an interference pattern at the output. (C) 2012 OSA 24 September 2012 / Vol. 20, No. 20 / OPTICS EXPRESS 22814

Fig. 1. Experimental setup for RI measurement. The inset shows the schematic diagram of the fiber FPI. Assuming that the light intensities of the reflected beams by the two surfaces of the FP cavity are I 1 and I 2, respectively, the interference signal intensity is: 4π nl I = I1 + I 2 + 2 I1I 2 cos( + ϕ0) (1) λ where λ is the wavelength of the incident light, n is the RI of the cavity medium, L is cavity length and ϕ 0 is the initial phase of the interference. At the fringe dip positions, the phase difference of the two reflected light beams satisfies the condition, 4π nl + ϕ0 = (2m + 1) π (2) λ m where m is an integer, λ m is the wavelength of the m th order interference dip. The fringe spacing in the spectrum can then be expressed as, 3. Device fabrication 2 λ Λ= (3) 2nL In the device fabrication, fs laser pulses (λ = 800 nm) of 120 fs at the repetition rate of 1 khz were focused onto the fiber end facet by a 20 objective lens with NA value of 0.5 and working distance of 2.1mm. The pulse energy used in the experiment was ~2 μj. A CCD camera was employed to monitor the fabrication process and record the sample morphology. A section of standard SMF-28 with the core diameter of 8.2 μm and the nominal effective RI of 1.4682 (at 1550 nm) was mounted on a computer controlled three-dimensional translation stage with a 40-nm resolution. The following steps were adopted in the fabrication process as illustrated in Fig. 2. Firstly, fs laser drilled a micro-hole of ~1 μm in diameter at the center of the cleaved fiber end facet, and the fiber tip obtained was then spliced together with another cleaved SMF tip without micro-hole by a fusion splicer (ERICSSON FSU975), with fusing current and fusing duration of 16.3 ma and 2.0 s respectively. The hollow sphere formed had a diameter of ~60 μm. Finally, a micro-channel of ~38 μm in diameter was machined to vertically cross the FP cavity, which allowed the RI liquid to readily flow in or out of the cavity. In the micro-channel fabrication process, laser beam was firstly focused on the top fiber surface at the micro-cavity position, scanned at a speed of 2 μm/s with a scanning distance of 40 μm, in parallel to the fiber core axis. After one scanning cycle, the laser beam was shifted by 10 μm, in perpendicular to the fiber axis until a 40μm 40μm square area was drilled through, to create the top part of the micro-channel. The fiber was then rotated by 180 to allow fabrication of the bottom part of the micro-cavity, following the same procedure as mentioned above. (C) 2012 OSA 24 September 2012 / Vol. 20, No. 20 / OPTICS EXPRESS 22815

Fig. 2. Fiber in line FPI cavity fabrication process. (a) The fs laser creates a micro-hole of ~1 μm in diameter at the center of cleaved fiber end facet. (b) The fiber tip with the micro-hole spliced together with another cleaved SMF tip. (c) FP cavity formed. (d) To fabricate a microchannels to vertically cross the micro-cavity. (e) Microscope image of the fiber in-line FPI cavity without the micro-channel. (f) Microscope image of the fiber in-line FPI cavity with the micro-channel. 4. Experimental results and discussion The RI measurement by the use of fiber in-line FP cavity was carried out at room temperature by immersing the sensor head in the RI liquids. Each time after the measurement, the device was rinsed with Propyl alcohol carefully until the original spectrum was restored and no residual liquid was left. The reflection spectra were monitored in real-time with an optical spectrum analyzer (OSA) with a resolution of 0.01 nm. Figure 3(a) shows the reflection spectra corresponding to the RI values of 1.315, 1.32 and 1.325, respectively, and a red shift of dip wavelength can be clearly observed. The transmission dip wavelength corresponding to different RI values within the range between 1.31 and 1.39 are demonstrated in Fig. 3(b), where a good linear relationship with the linearity of 99.9% is obtained. The RI sensitivity obtained is ~994 nm/riu, which is comparable to that of FPIs reported by other groups [1 3, 7], superior to that of the fiber RI sensors based on fiber Bragg gratings [19, 20], long-period fiber gratings [21] and conventional fiber interferometers [22 24], and much lower than that of the fiber open-cavity MZI, which reaches ~9370 nm/riu [17]. This is due to the fact that for FPI, the sensitivity is inversely proportional to the RI value of the cavity medium, whereas for MZI, it is inversely proportional to the RI difference of the cavity medium and the fiber core, which is much smaller than the RI of the cavity medium itself. The temperature influence on the FPI cavity RI sensor has been investigated by placing the fiber tip in an electrical oven and gradually increasing the temperature from 24 to 100 C. The temperature sensitivity obtained is ~4.8 pm/ C near the wavelength position of 1554 nm, as shown in Fig. 4. Based on the RI sensitivity of ~994 nm/riu, the temperature crosssensitivity of the sensor is ~4.8 10 6 RIU/ C. The temperature sensitivity of the fiber FPI sensor can be deduced from Eq. (2) as d λ m 4 dn dl = ( L + n) (4) dt 2m + 1 dt dt where dn/dt is the thermo-optic coefficient of cavity medium and dl/dt is the thermalexpansion coefficient of fiber material, ~0.55 10 6 / C for SMF-28 fiber. If the cavity medium is air, the thermo-optic coefficient of air is tiny and thus the term (dn/dt)l in the (C) 2012 OSA 24 September 2012 / Vol. 20, No. 20 / OPTICS EXPRESS 22816

above equation is negligible. Thermal-expansion effect plays a leading role in the temperature sensitivity. Fig. 3. (a) The reflection spectrum at RI = 1.315, 1.32 and 1.325, respectively (b) RI response of the sensor. Fig. 4. Temperature response of the sensor By changing the size of initial micro-hole and the fusion splicing parameters, the hollow sphere of different sizes and hence different cavity lengths can be created. Figure 5(a) shows three hollow spheres with different cavity lengths of 30, 65 and 93 μm respectively, corresponding to the initial micro-hole diameter of 1, 1 and 10 μm, the fusion current of 15.3, 16.8 and 17.3 ma, and the fusion duration of 1.5, 2.0, and 2.0 s respectively. The reflection spectra corresponding to different cavity lengths are displayed in Fig. 5(b). It can be found from this figure that, with the increase of cavity length from 30 μm to 93 μm, the fringe spacing around 1550 nm is decreased from 39.3 nm to 12.9 nm. The fringe spacing variation around 1550 nm with the air-cavity length was calculated according to Eq. (3), and the results obtained are shown in Fig. 5(c), where the black line stands for the calculated results and the red squares represent the experimental values obtained in Fig. 5(b). The experimental results agree well with the simulations based on FPI theory. Figure 5(b) shows that the reflection intensity monotonically goes up with the increase of cavity length. This is due to the fact that with a larger radius of the hollow sphere, the two reflection surfaces within the fiber core are nearly in parallel and hence the reflected light intensity can be enhanced. However, the fringe visibility does not change in a monotonic manner when the cavity length is increased as it depends also on surface reflectivity and propagation loss in the cavity. The size of the vertical micro-channel should be properly chosen to facilitate the RI liquid flow in and out of the FPI cavity. The micro-channel size of 20 and 38 μm were tested in the experiment, and the time taken for the liquid to be fully filled in the cavity was 15 minutes and a few seconds, respectively. The dependence of the filling time of the liquid on the size of micro-channel is due to the dependence of air pressure inside the micro-cavity on the size of (C) 2012 OSA 24 September 2012 / Vol. 20, No. 20 / OPTICS EXPRESS 22817

micro-channel. When the sample is immersed into the liquid, the air pressure inside the micro-cavity would prevent the liquid to flow in. If the micro-channel size is small, the air would slowly escape from the cavity and thus the filling time of the liquid is long. When the channel size becomes large, the air can quickly escape from the micro-cavity and a short filling time of the liquid can be achieved. Since the micro-channel is located purely in the cladding area, its size has no essential effects on the interference spectrum. However, a large channel size would reduce the robustness of the device. Fig. 5. (a) Microscope images of the FPI cavity with length of 30, 65 and 93 μm, respectively. (b) Reflection spectra of fiber in-line FPI with different cavity lengths. (c) Simulated fringe spacing as a function of cavity length at the wavelength of 1550 nm. The black line is the calculation result and the red square shows the experimentally obtained value. It should be mentioned that the system actually has two FP cavities. The second FP cavity is formed by the hollow sphere surface and the fiber end immersed in the liquid. Since the reflected light beam from the hollow sphere surface is divergent, and a large curvature of the hollow sphere surface corresponds to a large reflection light divergence, the interference fringe pattern of the second FP cavity is critically dependent on the cavity length. When the cavity length is large, the reflected light beam intensity is very small, which leads to an extremely poor fringe visibility and as a result, the corresponding fringe pattern can hardly be observed. In our experiment, the second cavity length is ~40 mm and the fiber end immersed in the liquid is not cleaved, thus no corresponding fringe can be observed. 5. Conclusion In conclusion, a fiber in-line FPI cavity sensor has been proposed and demonstrated for RI measurement. The change of liquid RI value causes the change of the optical path difference of FPI, which in turn leads to an interference spectrum shift. The RI sensitivity achieved in the experiment is ~994 nm/riu, and the temperature cross-sensitivity is ~4.8 10 6 RIU/ C. Such a device is simple in structure, easy in fabrication and reliable in operation. Acknowledgment This work was supported by the Hong Kong SAR government through a GRF (general research fund) grant PolyU 5298/10E and The Hong Kong Polytechnic University research grant 4-ZZE3. The authors also like to thank Dr. Ying Wang for helpful discussions. #172051 - $15.00 USD (C) 2012 OSA Received 6 Jul 2012; revised 6 Sep 2012; accepted 11 Sep 2012; published 20 Sep 2012 24 September 2012 / Vol. 20, No. 20 / OPTICS EXPRESS 22818