Protective Relays Digitrip 3000

Similar documents
Height: inches Width: inches Depth: inches, inches. Listings/Certification UL 1053 ANSI C37-90 IEC 255. General Description

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

Transformer Protection

Overcurrent Elements

POWER SYSTEM ANALYSIS TADP 641 SETTING EXAMPLE FOR OVERCURRENT RELAYS

Multimeter 500CVD21 RTU500 series

www. ElectricalPartManuals. com Basler Electric P. 0. BOX 269 HIGHLAND, ILLINOIS 62249, U.S.A. PHONE FAX

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

Overcurrent Protection / 7SJ45

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

BE1-32R, BE1-32 O/U DIRECTIONAL POWER RELAY

ASHIDA Numerical OC/EF Protection Relay

GE Power Management. Digital Microprocessor-based Non-directional Overcurrent Relays MIC series 1000 Instructions GEK 98840C

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Answers for energy

1 INTRODUCTION ORDER CODE / INFORMATION

POWER SYSTEM ANALYSIS TADP 641 SETTING OF OVERCURRENT RELAYS

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Earth Fault Relay EFSPL-1A/5A

Transformer Fault Categories

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

POWER SYSTEM PRINCIPLES APPLIED IN PROTECTION PRACTICE. Professor Akhtar Kalam Victoria University

U I. Time Overcurrent Relays. Basic equation. More or less approximates thermal fuse. » Allow coordination with fuses 9/24/2018 ECE525.

APPLICATION: The heart of the system is a DSR 100 Digital Static Regulator used in conjunction with standard SCR based rectifier bridges.

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Time-current Coordination

Metering Devices, Protective Relays, Software and Connectivity

NO WARRANTIES OF ANY KIND ARE IMPLIED ON THE INFORMATION CONTAINED IN THIS DOCUMENT.

Bus Protection Fundamentals

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

PD300. Transformer, generator and motor protection Data sheet

Reyrolle Protection Devices. 7PG21 Solkor R/Rf Pilot Wire Current Differential Protection. Answers for energy

Power systems Protection course

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Protection of Electrical Networks. Christophe Prévé

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

www. ElectricalPartManuals. com Generator Differential Relay MD32G Rotating Machine Differential Relay

Stabilized Differential Relay SPAD 346. Product Guide

MULTI FUNCTION OVER CURRENT AND EARTH FAULT RELAY[50/51X3,50/51N]

Protection of a 138/34.5 kv transformer using SEL relay

OVERCURRENT PROTECTION RELAY GRD110

System Protection and Control Subcommittee

RUDOLF Digital power analyzer. Advanced Version

ES-777-MV-P2_A1 03/01/10

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

DIAC Type 66K. DIGITAL OVERCURRENT RELAY Instruction Manual. GE Power Management

PRODUCT TEST MANUAL 2SY110K28 SYNCHRONISM CHECK RELAY

BUS2000 Busbar Differential Protection System

SPAD 346 C Stabilized differential relay

Current Transformer Requirements for VA TECH Reyrolle ACP Relays. PREPARED BY:- A Allen... APPROVED :- B Watson...

Instantaneous Overcurrent Relay

Instructions AVC125-10: Voltage Regulator. Voltage Range. Maximum Continuous Burden. Voltage Range. Nominal Frequency

1960 Research Drive, Suite 100, Troy, Michigan with. REVISION: December 10, 2007 (Supersedes previous versions) Prepared by:

Replacement solution

STATIC EARTH FAULT RELAY

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

SPECIFICATION FOR OVERCURRENT RELAYS

Protection Introduction

Generator Protection M 3420

Power System Protection Manual

Electrical Protection System Design and Operation

NTG MULTIFUNCTON GENERATOR PROTECTION RELAY. NTG-Slide

DISTRIBUTION DEVICE COORDINATION

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

Technical catalogue. Emax Low voltage air circuit-breakers. Hotline:

Over or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors

Power Meter Series PM3200 Functions and characteristics

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Transformer protection IED RET 670

McPherson Voltage Regulators 4501 NW 27 Ave Miami FL

Application and Commissioning Manual for Numerical Over & Under Voltage Protection Relays Type MVT181 CONTENTS PAGE APPLICATION 2-7 INSTALLATION 8-16

Distribution/Substation Transformer

Detecting and Managing Geomagnetically Induced Currents With Relays

Power Processor - Series 700F 10KVA to 150KVA

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control

INSTRUCTION MANUAL FOR TIME OVERCURRENT RELAY BE1-51

D I G I T A L V O L T A G E R E G U L A T O R

Maintenance/Connection/Installation Service life C/O cyclesx1000

SEL-251 Distribution Relay

Digital Multifunction Instrument - Rish Master 3440

Transformer differential protection

Transmission Lines and Feeders Protection Pilot wire differential relays (Device 87L) Distance protection

ARC FLASH PPE GUIDELINES FOR INDUSTRIAL POWER SYSTEMS

Generator Protection GENERATOR CONTROL AND PROTECTION

DPF-MAC Auto power factor controller

INSTRUCTION MANUAL. AQ F3x0 Feeder protection IED

A Tutorial on the Application and Setting of Collector Feeder Overcurrent Relays at Wind Electric Plants

BE1-81O/U DIGITAL FREQUENCY RELAY FEATURES

Protection relays and transformers

Redundant Bus Protection Using High-Impedance Differential Relays

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Protection and control VIP300. Technical manual

Protective Relaying for DER

Transcription:

New Information Technical Data Effective: May 1999 Page 1 Applications Provides reliable 3-phase and ground overcurrent protection for all voltage levels. Primary feeder circuit protection Primary transformer protection Backup to differential protection May be used where instantaneous and/or time overcurrent protection is required Ground element capable of residual, zero sequence or external source connections Protection Functions Phase overcurrent protection per time-current curve Independent ground fault protection per time-current curve Curve shapes: ANSI, IEC, or thermal curves True RMS sensing of each phase and ground current Phase instantaneous OC Ground instantaneous OC Zone selective interlocking (phase and ground) for bus protection Monitored Values Phase currents Ground currents Magnitude and phase of current causing trip Peak demand current for each phase and ground since last reset Communication Interface capability to computer network for data collection, storage and/or printout via the PowerNet system Physical Characteristics User-friendly front panel Program and test mode security access cover Internal circuitry self-testing Optional quick-release drawout case Optional dual source power supply Height: 10.25 inches Width: 6.722 inches Depth: 2.733 inches, 3.948 inches Listings/Certification UL 1053 ANSI C37-90 IEC 255 General Description The Protective Relay is a multifunction, microprocessorbased overcurrent relay designed for both ANSI and IEC applications. It is a panel-mounted, self-contained unit which operates from either ac or dc control power. The DT- is available in an optional quick-release drawout case for panel-flush mounting. For ac control power applications, an optional Dual-Source Power Supply (DSPS) is recommended. The design provides true RMS sensing of each phase and ground current. Only one unit is required for each three-phase circuit. Current monitoring and operator selectable protective functions are integral to each relay. The DT- Relay operates from the 5 ampere secondary output of standard current transformers. Current transformer ratio information is quickly programmed into the unit via settings. This enables the relay to display metered current in primary amperes. The features a userfriendly operations panel to monitor, program, and test the relay. Operating parameters and troubleshooting information are displayed in the two highly visible display windows. In addition, all data and information can be communicated to a host computer equipped with the appropriate software. A Communication Trip and Communication Close control command can also be initiated by a host computer with an authorized access code for remote breaker operation.

Technical Data Page 2 Effective: May 1999 DIP Switches Terminal Block 1 Rear View Communication Connection Terminal Block 2-1 Terminal Block 2-2 Terminal Block 2 Current Transformer Connections The relay has special provisions for connection in a Zone Interlocking Scheme which can be used for bus protection or to improve protection coordination in a tight or close system. Zone interlocking is described in more detail on page 41. Overcurrent Protection The provides complete 3-phase and ground protection with separate elements and settings. The relay can be used with CT ratios from 5/5 to 5000/5. The CT ratio can be set independently for phase and ground allowing the ground element to be connected in either the residual or the separate ground CT configuration, as in Figures 4 and 5. Applications General The microprocessorbased relay provides reliable 3-phase and ground overcurrent protection for all voltage levels. It can be used for any application where instantaneous and/or time overcurrent protection is required. It is most commonly used as primary feeder circuit protection, as in Figure 1. 50 51 50G 51G CB 52 Load Figure 1. Primary Feeder Circuit Protection CB 50 51 50G 51G Figure 2. Transformer Overcurrent Protection The may be connected to the secondary side of a Delta-wye grounded transformer with the ground element connected to a separate CT in the neutral connection of the transformer. With this connection, a lower CT ratio and a pickup setting can be used to provide more sensitive ground fault protection especially for resistance grounded systems (see Figure 3). CB-52 a b c GND A1 B1 C1 G1 A2 B2 C2 50/51 50N/51N G2 Figure 4. Residual Ground Connection CB-52 a b c GND A1 B1 C1 G1 50/51 50G/51G A2 B2 C2 Figure 5. Separate Zero Sequence Ground CT Connection G2 The may be applied as the transformer primary protection or as backup to the differential protection, as in Figure 2. 50G 51G 50 51 Resistor CB Figure 3. Transformer Secondary Protection with Neutral CT Connection

Technical Data Effective: May 1999 Page 3 Selective Curve Types I 4 t (Curve Shape) I 2 t It (Curve Shape) MOD (Curve Shape) IEC-A IEC-B FLAT TIME (Short Delay) TIME VERY (Short Delay) TIME (Short Delay) XTRM (Instantaneous) (Instantaneous) IEC-D IEC-C (Instantaneous) CURRENT Thermal Curves CURRENT CURRENT ANSI Curves IEC Curves Figure 7. Time Overcurrent Curve Shapes The phase and ground overcurrent characteristics are defined by six parameters as in figure 6. 1. Curve shape 2. Overcurrent pickup 3. Time multiplier or dial 4. Short delay pickup 5. Short delay time 6. Instantaneous pickup Phase or Ground Overcurrent Characteristics T I M E ➄ Figure 6 ➀ ➁ ➂ ➃ CURRENT ➅ Phase Curve Shape The includes the thermal, ANSI and IEC family of curves as in Figure 7 which makes it easy to coordinate with any conventional protection scheme. The user can select Moderately Inverse, Very Inverse, Extremely Inverse or Definite Time characteristics. The Thermal curves It, I 2 t, I 4 t and Flat Slopes can also be selected. Phase Time Overcurrent Protection Time overcurrent (overload and fault) protection is defined by the current pickup setting and time multiplier. Phase Short Time Protection Short time (fault) protection responds to short circuit conditions. It is similar to the Phase Time Overcurrent Protection in that current and time settings are offered. It differs, however, in two ways: (1) NONE is a Short Delay Pickup setting which, if selected, will disable the Phase Short Time Protection, and (2) a slope selection is not available for the time line. Instantaneous Protection Instantaneous (short circuit) protection reacts to high level fault currents with no additional time delay. If NONE is selected for the instantaneous setting, the instantaneous trip function is disabled and a true making current release (discriminator) function is provided. If selected, the discriminator is functional for 10 cycles and will trip the breaker instantaneously, if the fault current is above 11 times (I n ). Ground Fault Protection The ground fault protection function is a composite of the Ground: Curve shape Time overcurrent and pickup time settings Short delay current and time settings Instantaneous setting These are similar to the phase overcurrent functions. A NONE setting selection disables that characteristic of the ground fault protection. Sensitive Ground Fault Protection The DT- overcurrent relay is available with an optional sensitive ground fault function. This feature provides a ground time overcurrent pickup range from 0.01 to 0.2 per unit and an instantaneous pickup range from 0.05 to 1.1 per unit. This can be used for ground fault protection where the total ground fault current is limited by a grounding resistor. Zone Selective Interlocking (Phase and Ground) Zone Selective interlocking is a protection function to minimize equipment damage resulting from a phase or a ground fault in an area where long time and/or short time delay is in use. When the Ground Zone Interlocking feature is utilized, an immediate trip is initiated when the fault is in the breaker s zone of protection, regardless of its preset time delay. When the Phase Zone Interlocking feature is utilized, the time overcurrent and short delay phase elements work as follows. The short delay phase element will initiate an immediate trip when the fault is in the breaker s zone of protection, regardless of its preset time delay. For the time overcurrent phase element, the current sensed by the DT- must

Technical Data Page 4 Effective: May 1999 Sample Zone Selective Interlocking System Main Breaker A A Zone 1 Feeder Breaker B B Interlocking Wire Zone 2 Downstream Breaker C C Zone 3 LOAD Figure 8 exceed 300 percent (3 x I n ) for the zone selective interlocking to initiate an immediate trip signal when the fault is in the breaker s zone of protection. Upstream protected breakers are restrained from tripping immediately by an interlocking signal from the downstream relay. This interlocking signal requires only a pair of wires from the downstream breaker to the upstream breaker. It provides standard coordinated tripping when the fault is located outside the zone of protection. In the sample zone interlocking system shown above, circuit breakers A, B and C are equipped with overcurrent relays. Fault Location Zone 3➀ If a fault occurs at a point in Zone 3, the of Downstream Breaker C senses the fault and sends a restraining signal to the upstream of Feeder Breaker B. Having received this signal, the of Feeder Breaker B withholds its trip command. As a result, only Downstream Breaker C is tripped. Fault Location Zone 2➀ If a fault occurs at a point in Zone 2, the of Feeder Breaker B senses the fault and sends a restraining signal to the upstream of Main Breaker A. The of the Downstream Breaker C does not see this fault since it is situated on the downstream side of the fault. As a result, the of Downstream Breaker C does not send a restraining signal to the of Feeder Breaker B. Since it did not receive a restraining signal from the of Downstream Breaker C, the of Feeder Breaker B identifies that the fault is in Zone 2 and immediately trips Feeder Breaker B, regardless of its time setting. Fault Location Zone 1➀ If a fault occurs in Zone 1, no restraining signal is received by the of Main Breaker A. As a result, Main Breaker A is immediately tripped by its overcurrent relay, regardless of its time setting. Drilling Pattern 8.90 6.68 4.45 Figure 9 2.23 2.69.06 RAD 4 Places 2.53 5.38 5.06 4.69 9.38.218 DIA 10 Places ➀ For the phase time overcurrent element, the current sensed by the must exceed 300 percent (3 x I n ) for the zone selective interlocking to initiate an immediate trip signal.

Technical Data Effective: May 1999 Page 5 Layout Dimensions Trip Unit Dimensions (Inches) 3.360 6.720.514 2.733 1.871 3.742 5.125 Time Overcurrent Curve Pickup (xln) Time Multiplier Operational High Load Communications Trip RMS Amperes Reset 4.655.375 Typical Short Delay Pickup (xln) Amp Demand Time I A Phase Ground Instantaneous Pickup (xln) I B I C I G Select Terminal Block 1.484 In=5A (Secondary) or CT (Primary) Settings/Test Time/Trip Cause Program Test View Settings 5.250 10.250 Program Program Select Settings Save Settings 9.310 Raise Test Select Tests Lower Test Test.500 1.052.624 3.021.288 Figure 10 Typical Wiring Diagram Figure 11

Technical Data Page 6 Effective: May 1999 Specifications Current Inputs CTs: 5A Secondary CT Burden: <0.004 ohm @ Rated Current (5A) <0.1VA @ Rated Current (5A) I n : 5A (Secondary) or CT (Primary) Saturation: 30 x I n CT Thermal Rating: 10A Continuous 500A for 1 Second CT (Primary) Settings Available Phase and Ground: 5/10/25/50/75/100/150/200/250/ 300/400/500/600/630/800/1000 1200/1250/1500/1600/2000/2400 2500//3200/4000/5000 Input Voltage➀ Nominal: 48 to 250 Vdc 120 to 240 Vac 50/60 Hz Operating Range: 28 to 280 Vdc 90 to 254 Vac 50/60Hz Power Consumption: 48 125 250 120 240 Vdc Vdc Vdc Vac Vac 10W 17W 18W 18VA 25VA Output Trip Contacts: (Trip OC/Comm., Trip Inst., and Comm. Close) Momentary: Make 30A ac/dc for 0.25 Sec. Break 0.25A @ 250 Vdc Break 5A @ 120/240 Vac Continuous: 5A @ 120/240 Vac 5A @ 30 Vdc Meets ANSI C37.90, Paragraph 6.7 Environment Operating Temperature: -30 to +55 C Operating Humidity: 0 to 95% Relative Humidity (Non-condensing) Storage Temperature: -40 to +70 C Auxiliary Alarm Contacts 5A Continuous @ 120/240 Vac, 30 Vdc 5A Break @ 120/240 Vac, 30 Vdc ➀ Consult factory for 24/48 Vdc input voltage specification ➁ Consult factory for sensitive ground fault specification Tests Dielectric Strength: Current Inputs: Vac for 1 Minute Phase to Phase Seismic Test: Meets requirements for UBC and California Building Code Zone 4. ZPA = 3.5 Standards: ANSI C37.90, 1989 IEC 255 UL 1053 Phase and Ground Time-Current Curves Thermal: It (Moderately Inverse) I 2 t (Very Inverse) I 4 t (Extremely lnverse) FLAT (Definite Tlme) ANSI: (Per ANSI C37.112, 1996) Moderately Inverse Very Inverse Extremely Inverse IEC: (Per IEC 255-3, 1989) IEC-A (Moderately Inverse) IEC-B (Very Inverse) IEC-C (Extremely Inverse) IEC-D (Definite Time) Overcurrent Functions and Pickup Ranges➁ Long Delay or Inverse Time Overcurrent: Phase: Ordering Information Description (0.2 to 2.2) x I n (28 Settings) Ground: (0.1 to 2.0) x I n, None (26 Settings) Short Delay: Phase: (1 to 11) x I n, None (25 Settings) Ground: (0.1 to 11) x I n, None (45 Settings) Drawout Relay Drawout Inner Chassis Drawout Outer Chassis with 120 Vac Dual Source Power Supply with 240 Vac Dual Source Power Supply with 24/48 Vdc Power Supply with 24/48 Vdc Power Supply in Drawout Case with Sensitive Ground Fault Protection Instantaneous: Phase: (1 to 25) x I n, None (30 Settings) Ground: (0.5 to 11) x I n, None (33 Settings) Time Delay Settings Inverse Time Overcurrent Time Multiplier: It, 1 2 t, 1 4 t Curve: 0.2 to 40 (47 Settings) FLAT: 0.2 to 2 (21 Settings) ANSI (all): 0.1 to 5.0 (50 Settings) IEC (all): 0.05 to 1.00 (20 Settings) Short Delay Time: 0.05 to 1.5 sec (22 Settings) Current Monitoring➁ True RMS Sensing: 3-Phase and Ground Display Accuracy: ±1% of Full Scale [ln] from 0.04 x l n to 1 x I n ±2% of Full Scale [l n ] from 1 x l n to 2 x I n Ampere Demand: Average Demand over 5 Minute Sampling Window High Load: 85% of Inverse Time Overcurrent Setting Timing Accuracy Inverse Time Overcurrent Time: ±10% @ >1.5 x Pickup Short Delay Time: ±50 ms Standards: ANSI C37.90 IEC 255 UL 1053 Communications PowerNet Compatible: Built-in INCOM Data Rate is 1200 or 9600 Baud Catalog Number DT DT3001 DT3001-IC DT3001-OC DT3010 DT3020 DT3030 DT3031 DT3200

Technical Data Effective: May 1999 Page 7 Notes

Technical Data Page 8 Effective: May 1999 Copyright Inc., 1999. All Rights Reserved. TD1710TE Printed in U.S.A. / ZTD99011