Connect - Contact - Control. DC Contactors 600V / 750V / 1000V. F 215e

Similar documents
B 80.en. Single pole cam contactors for DC and AC applications C160, C162 Series. Connect - Contact - Control max. ED: 100% U 14,4V.

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Connect - Contact - Control. Connectors. Short Form Catalogue

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

COMPONENTS. Power contactor Type BMS09.08 / BMS18.08

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

NS..S contactor relays - with spring terminals AC operated

Capacitor Switching Contactors

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Controls Contactors and Contactor Assemblies Special Applications

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Relay interface modules A

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

UBC 200 relay - Voltage monitoring

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

3 - Protection components Circuit-breakers

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Output of three-phase motors at 50 Hz and 400 V

62.22 Copper side view

190S A N D 2 C A16 C TE

Installation and Operational Instructions for ROBA -switch Type 017._00.2

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

RELOG. All-or-nothing Relay

48 Series - Relay interface modules A. Features

Characteristics 5 TeSys k contactors and reversing contactors

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

VARIOCON. Modular Contact Inserts

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Type: DILEM 10 G(24VDC) Article No.:

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

High-Speed DC Circuit-Breaker for Fixed Installation Type UR26, UR36 & UR40

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

3RA13, 3RA14 Contactor Assemblies

2 or 4 pole changeover contact Plug-in/Faston 187

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

3RH1 contactor relays, 4- and 8-pole

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

UB 200 relay - Voltage monitoring

Micro-Contactors LAM ONLINE SHOPPING! Get Ready. Get Schrack. In the office and on the go with the Live Phone App.

CX-Series. Circuit Breaker

Model Number Structure

OMRON MK-I / -S RELAY

CX-Series. Circuit Breaker

UB 001 relay - 1 level load shedding

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

62 Series - Power relays 16 A. Features / /

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Description Basic devices with positive operation contacts

Installation / Monitoring Technique

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

MINI-PS AC/24DC/1.3

Pluggable interface relays CR-P Pcb relays

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Computer-14d - xx - 144a

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

General data. Technical data DIKD 1,5. General. Dimensions

Electronic Circuit Breaker with reset input ESS20-1..

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

The Best Relaytion. Cradle Relay S Rev. B EC-JM ECOC: JM10 1. Aug. 04

38 Series - Relay interface modules A. Features /

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

190S A N D 2 C A16 C TE

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Transcription:

Connect - Contact - Control DC Contactors 600V / 750V / 1000V F 215e

2 Contents Application... 3 Technical Data... 3 Load Ratings... 3 Device Identification... 4 Coil Power Reduction... 5 Fire Rating... 5 Application Data... 5 Single Pole Contactor, Series S162... 6 Single Pole Contactor, Series S195... 7 Multipole Contactor, Series S155 to S157... 8 Auxiliary Contacts... 9 Spare Parts... 9 Page

3 DC Contactors, 600V to 1000V Application These devices are suitable for use in commuter and light rail vehicles. Potential applications include heating, air conditioning and on-board-power conversion. They are sturdily constructed, capable of switching large loads and require only minimal space. The contactors described herein are based on designs with an excellent track record of long-term applications in harsh environments. Technical Data Continuous Thermal Current (I th ) w/o electronic coil power reduction w/ electronic coil power reduction S 155 S 156 S 157 S162 S 195 250 A 250 A ---------- 250 A 250 A 300 A 300 A 250 A ---------- ---------- 2) Number of Main Contacts 2 3 4 1 1 Nominal Load per Contact U nom = 750 V (U = 900 V) max U nom = 1000 V (U = 1300 V) max DC 1 100 kw 100 kw 100 kw 100 kw 50 kw DC 5 18 kw 18 kw 18 kw 18 kw 11 kw DC 1 50 kw 50 kw 50 kw 50 kw 35 kw DC 5 10 kw 10 kw 10 kw 10 kw 7 kw Maximum Load per Contact U nom = 750 V (U = 900 V) max U nom = 1000 V (U = 1300 V) max DC 1 > 500 kw > 500 kw > 500 kw > 500 kw > 280 kw DC 5 > 100 kw > 100 kw > 100 kw > 100 kw > 76 kw DC 1 > 160 kw > 160 kw > 160 kw > 160 kw > 110 kw DC 5 > 50 kw > 50 kw > 50 kw > 50 kw 50 kw Switching Cycles per Hour 1800 3600 6 6 6 Mechanical Life, Cycles > 2 x 10 5 x 10 > 3 x 10 Insulation Tested per VDE 0115, Group D, at 3,9 kv for U nom = 1200 V Creep and arcing distances for contamination category 3 for U nom = 1000 V per VDE 0660, Part 100 Nominal Coil Power (DC) at 125% U and coil at operating temperature nom Pick-up 240W Holding: 40W Holding: 10W (with series resistor) (with electronic power reduction) 18 W 19 W Nominal Coil Voltage (DC) 24 V... 110 V 24 V... 110 V 24 V... 110 V 24 V... 110 V 24 V... 110 V Voltage Range Operating Temperature Range Storage Temperature Range 70 to 125% U nom -25 C to +70 C (-13 F to +158 F) -40 C to +80 C (-40 F to +176 F) Load Capacity Applicable Standards IEC 77; VDE 0115; VDE 0660 Shock Resistance 5 g 5 g 5 g 5 g 5 g Weight ca. 4,5kg (9,9lb) ca. 5,0kg (11lb) ca. 5,5kg (12,2lb) 2,3kg (5,1lb) 2,0kg (4,4lb) Blow-out Method Permanent Magnet Coil Suppressor Loads certified per VDE 0660, part 100 at U nom and U max. Current turn-off is unidirectional only. The load ratings in the above tabulation are for a single switching element only. By placing two contacts in series the load capacity can be increased by a factor of 2. Partition plates (Part No. 0295 822) may have to be inserted between the main switching elements. 3) Varistor 2) 4 pole contactor S157 can optionally be equipped with electronic coil power reduction only. 3) Dependent on the number of auxiliary contacts applied. The placement of two contacts in parallel permits an increase of the continuous thermal current rating (I th ) by a factor of 1,7. Since two neighboring elements will never switch exactly synchronous, the load rating for the single contact must never be exceeded.

4 Device Identification for Series S155 - S157 Series S155, S156, S157 Nominal Voltage N = 1000V (U max = 1200V) DC *) S 1 5 5 - N 2 0 - E - 1 1 0 - G 1 Main Contacts 1st digit: No. of NO contacts 2nd digit: No. of NC contacts Coil Power Reduction E = Electronic S = Series Resistor Coil Voltages 110V (24, 48V, 72V, Special Voltages) Auxiliary Contacts G = S 826 a K = S 826 a20 L = S 800 a M = S 800 a20 (a: Screw Terminal; a20: Quick Disconnect Terminal) No. of Auxiliary Contacts (see page 9) *) For low voltage contactors, series S155 - S157, see listing B80 Device Identification for Series S162 Series Nominal Voltages N = 1000V (U max = 1200V) DC *) Coil Voltage 110V (24, 48V, 72V, Special Voltages) Auxiliary Contacts G = S 826 b K = S 826 b20 M = S 800 b20 N = S 804 b (b: Screw Terminal; b20: Quick Disconnect Terminal) (see page 9) S 1 6 2 - N 1 1 0 - G *) For low voltage contactors, series S 162 see listing B90 Device Identification for Series S195 Series Nominal Voltage AE = 1000V (U max = 1200V) DC *) Auxiliary Contacts 0 = None 2 = One Aux. Contact with Quick Disconnect Terminals 3 = Two Aux. Contacts with Quick Disconnect Terminals Coil Voltage 110V (24, 48V, 72V, Special Voltages) S 1 9 5 - A E - 0-1 1 0 *) For low voltage contactors, series S195 see listing B95

5 Coil Power Reduction Circuit This device can be used with multipole contactors S155 through S157. The power reduction module decreases coil holding power to approximately 10 W. Holding current is independent from the applied control voltage. The contactor will operate reliably between 70% and 125% of the nominal control voltage. The application of the power reduction circuitry alters the drop-out performance of the contactor at decreasing coil voltage U ctl. In standard applications drop-out will occur at U ctl < 60% of U nom. For some applications special solutions will have to be employed. Control inputs will accept external control devices (e.g. overcurrent annunciators, etc.). 1 2 (+) 3 ( ) 4 Plan View Component Side 5 6 Input Function 1 2 Control Input 3 4 5 6 Control Voltage U (observe polarity!) Coil connections factory installed Input terminals 1 through 6 are equipped with WAGO spring-clip type. ctl Fire Rating Series S155 through S162 and S195: Plastic material for coil bobbins, contact carrier and arc chute conform to UL 94 - VO. Application Information Reliability of operation is enhanced if the devices are positioned so that the prime shock axis does not coincide with the direction of the arrows shown. Distance between contactors: 5mm (0,2) ** Distance to current carrying parts: 10mm (0,39) **) dimensions in brackets are given in inch Series S152 through S162 Series S195 P = Rated Load a = 70mm (2,75) P > Rated Load a = 100mm (3,94) a a P = Rated Load a = 20mm (0,79) b = 30mm (1,18) P > Rated Load a = 20mm (0,79) b = 60mm (2,36) a b Mounting Position No special orientation required, preferred orientation with spring downwards. a Mounting Position No special orientation required, upright orientation preferred.

6 Single Pole Contactor, Series S162 Device Outline: 3 1 Mounting Template: 2 Series S162 Contact (Pos. and arc chute (Pos. 2) can be easily replaced if necessary (for part No. see page 9). Keying prevents reverse insertion of the arc chute. Terminal Sizes S 162 Polarity S 162 Main Contact M10 Coil no special requirements Coil M4 Main Contact Observe correct Polarity! Arc Chamber (Pos. 3) For further information see list B80

7 Single Pole Contactor, Series S195 2 1 Series S 195 Mounting Template: Device Outline: View A 3 A Terminal Sizes S195 Polarity S195 Main Contact M8 Coil no special requirements Coil Connector A 6,3 Main Contact Observe correct Polarity! (Pos. 3) To change arc chamber (Pos. remove cover (Pos. 2). For further information see list B95

8 Multipole Contactors, Series S155 - S157 Contacts can be normally open (NO) or normally closed (NC). 3 Device Outline: 2 1 M10, max. 10Nm Width b Series S 155 Device Outline (with electronic coil power reduction): Mounting Template: M8 M5 M10, max. 10Nm Contacts (Pos. and arc chute (Pos. 2) can be easily replaced (for part No. see page 9). Keying prevents reverse insertion of the arc chute. Width b dependent on number of main and aux. contacts used. Series Width b [mm] Width b [mm] with up to 2 aux. contacts with up to 4 aux. contacts S 155 134mm (5,28) 172mm (6,77) S 156 134mm (5,28) 170mm (6,69) S 157 172mm (6,77) 208mm (8,19) Terminal Sizes S155, S156, S157 Polarity S152 - S157 Main Contact M10 Coil no special requirements Coil M4 Main Contact Observe correct polarity! Arc Chute (Pos. 3) For further information see list B90

9 Auxiliary Contacts Series Type Quantity S155 - S157 S 800a xx S 826a xx 4 max. S162 S 826b xx 1 max. S 804b (For mounting of an assembly see table page 7 on list B80) 2) S195 S 870z 2 max. One NO and one NC contact; I th = 10 A 2) One change-over contact; I th = 3 A Contacts S800 and S826 can be supplied with either screw terminals (XX = blank) or connector (XX = 20). For further information see listings D19, D20 and D23. Note: for small current switching at low voltages (24V and below, e.g. computer inputs, etc.) use contacts S826 and S870. Spare Parts Series Contact Part No. Continuous Current [I ] th Arc Chute Part No. S155, S156 S307 CN 1512.0293 677 300A LK 307 DC 1754.0 265 592 S157, S162 S307 GN 1512.0293 666 250A LK 307 DC 1754.0265 592

10 Electrical Components and Systems for Railway and Industrial Applications Connectors Switchgear Switching Elements Control and Signal Devices Systems and Components for Railway Technology Industry-standard connectors Special connectors for communication technology (MIL-connectors) Connectors for railway technology including UIC connectors Special connectors per customer requirements Single and multipole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Special devices per customer requirements Snap-action switches with direct opening action Snap-action switches with self-cleaning contacts Switching elements with high breaking capacity Control and safety switches DC emergency break switches Special switches per customer requirements Master controllers and reversers for railway applications Toggle switches Hand-operated and foot switches for railway applications (Dead Man s Device) Emergency brake handle Power supply plants for passenger coaches Battery chargers for locomotives and restaurant cars High-voltage equipment for single and multi-voltage operation Heaters Projecting performance for passenger coaches Projecting performance for diesel MUs Electrical drives with magnetic drive technology Special devices per customer requirements SCHALTBAU AKTIENGESELLSCHAFT Klausenburger Straße 6 D-81677 München Germany F1573/9602/2.0 Printed in the Federal Republic of Germany by Schaltbau Telephone +49 89 93005-0 FAX +49 89 93005-350 e-mail schaltbau@schaltbau.de We reserve the right to make technical changes without prior notice. Issued June 1999