SUTURA Nonabsorbable surgical suture U.S.P Black Braided Silk.

Similar documents
MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE

SURGIPROTM II~ SUTURE

Monofilament polypropylene Suture

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your

SUTURE MATERIALS PRINCIPLES OF SUTURE SELECTION PRINCIPLES OF SUTURE SELECTION... 32

Complete Sutures Range

PLAIN GUT PlAIN g UT

SUTURE MATERIALS PRINCIPLES OF SUTURE SELECTION PRINCIPLES OF SUTURE SELECTION... 32

Cost savings without compromise

Objectives. xxx00.#####.ppt 5/10/17 9:42 AM

POLYSORBTM SUTURE PO lysorb SUTURE

นพ.สม ทธ สร อยมาด โรงพยาบาลวช ระภ เก ต

Novosyn Quick Your fast and efficient solution for a better quality of life

Dental Sutures. Japanese quality for best results.

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Hu-Friedy PERMA SHARP SUTURES HIGH PERFORMANCE PRECISE RESULTS

Integra. Capture Screw System SURGICAL TECHNIQUE

CDHB CLINICAL SKILLS UNIT

tevdek ii the specialist green, polyester, braided suture material With special ptfe coating indications needle OVeRVieW ROunD bodied needles

Simple Interrupted Suture (using a tea towel)

Chirurgische materialen

ETHICON Wound Closure Suture Products. ETHICON Wound Closure Suture Products. International Market Development

Manuals are subject to change; the most current version of each manual is always available online. Printed on: November 25, 2015

Simple Interrupted Suture (using a silicon skin pad)

Minimally Invasive Suturing Devices

The Perfect Close. to your surgical procedure. PER F ORM ANC E through innovation

18-8 stainless steel surgical needles. coated, braided synthetic sutures VIAMAC REACT* coated, black braided sutures

The Perfect Close. to your surgical procedure. PER F ORM ANC E through innovation

Techniques of the hand tie and instrument tie

MaxTorque. surgical technique. Cannulated Screw System. Foot & Ankle. OrthoHelix Technology

MonoPlus. THE LONG-TERM OPTION FOR SLOW HEALING Synthetic long-term absorbable monofilament suture made of polydioxanone

Expertise in Surgery.

BioDrive Micro Screw System

Making Skin Closure Fast and Simple.

Minimal Invasive Surgery develops very fast. In all field of surgery users search ways to use this technique for various indications.

Veterinary Sutures & Bottles

Digital Compression Screw

7.0 mm Cannulated Screws

ASAHI Peripheral Guide Wire

MED EUROPE EUROPEAN MEDICAL SUPPLIES s.r.l. Special Dental Sutures

Wound Care & Suture Techniques

Hu-Friedy PERMA SHARP SUTURES HIGH PERFORMANCE PRECISE RESULTS

Australian designed sutures for large animal surgeries 2016 CATALOGUE

SUTURES POCKET GUIDE PRODUCT INFORMATION

Suturing simplified. The first and only reusable, articulating, curved needle driver.

90 SCREWDRIVER Minimally invasive drilling and screw insertion

Strength of sliding knots in multifilament resorbable suture materials

Selection and use of surgical needles

rainbow ReSposable Pulse CO-Oximeter Sensor System Training Please see product s Directions for Use for more information 2012 Masimo Corporation

Laser Glasses

T i t a n i u m I n s t r u m e n t s

SUTURES AND AEOS EPTFE MONOFILAMENT

Guardian Sensor (3) User Guide

HCS 1.5. The countersinkable compression screw.

Lynn Lawrence, MD Cardon Children s Medical Center

WOUND CLOSURE MANUAL

TABLE OF CONTENT. 1. Introduction 1.1. Foreword Treatment objectives Work materials 2.1. Braces and loops

OPERATIVE TECHNIQUE RIVAL REDUCE FRACTURE PLATING SYSTEM. foot & ankle trauma procedures

Surgical Technique 1

Instruments for Removing DePuy Synthes Screws. Screw Removal Set

STILLE Micro Instruments. Solid Performance - Outstanding Precision

Distal Medial Tibia Plate Surgical Technique

INTRODUCTION AND HISTORICAL PERSPECTIVE

Institute of Surgical Research A Module - Surgical Techniques

edge of the section wound, probably from opening of the wound

3.5 mm Cannulated Screw Technique Guide

OPERATIVE TECHNIQUE RIVAL BITE HEADED CANNULATED AND HEADLESS COMPRESSION SCREWS. foot & ankle applications

CATARACT SUTURES* During the last 15 years a great deal has been written on the subject of

Proximal Humerus Plate 3.5 Surgical Technique

Peanut Growth Control Plating System. Surgical Technique

Technique Guide. 7.0 mm Cannulated Screws. Part of the Synthes Cannulated Screw System.

Super Revo. Surgical Technique. Super Revo Shoulder Fixation System. The Ideal Fixation Device For Rotator Cuff Repair. Self-drilling, titanium anchor

anchor surgical needles and other OR related products

Surgical Handpiece. Ti-Max Ti-Max Ti-Max Ti-Max X-SG20L X-SG25L X-SG93L X-SG93. S-Max SG M OM-C0425E

Intracorporeal Knot-Tying and Suturing Techniques in Laparoscopic Surgery: Technical Details

SUTURES AND WOUND CLOSURE TECHNIQUES. An Introductory Guide

W O U N D H E A L I N G

Variable Angle LCP Mesh Plate 2.4/2.7. Part of the Variable Angle LCP Forefoot/Midfoot System 2.4/2.7.

HDR Prostate Contour Templates

Bomei Co., Ltd. 4F., No , Chunrih Road, Taoyuan City, Taoyuan County, Taiwan Tel: / Fax: / Web:

Champion Instrumentation. Shoulder Repair Made Simpler

Slide 1 Basic Suturing Christina Shelley, RN, MSN, FNPC Amanda Shelley, MS, PAC. Slide 2. Slide 3. Objectives BASIC SUTURING MOVIE

Reliability and precision our suture materials NON-ABSORBABLE. Surgical sutures. Convincing down to the smallest detail

ADVANCED TISSUE-MANAGEMENT

SUTURES. 9 Circuit Drive Hendon SA 5014 AUSTRALIA

Cerclage Passer. For minimally invasive application of cerclage cables.

ARTHROSCOPIC ROTATOR CUFF REPAIR SURGICAL TECHNIQUE. The following techniques are described by Vernon J. Cooley, M.D.

Integra. Stainless Headed Compression Screw System SURGICAL TECHNIQUE

Aesculap Surgical Instruments

Arthroscopic Protector Meniscus Suturing Surgical Techniques

The OPUS AutoCuff System for Rotator Cuff Repair

Part of the DePuy Synthes Cannulated Screw System. 3.5 mm Cannulated Screws

Mini Photo Printer User Manual

Principles of Veterinary Suturing

Small Plate and Screw System SURGICAL TECHNIQUE

Integra. surgical Technique. Total Wrist Fusion System. Products for sale in Europe, Middle-East and Africa only

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

Medical Video 2. Endoscopy Equipment. Bronchoscopy. Colonoscopy. Gastroscopy. Key Points Medical Video 2 - Endoscopy:

PARS Achilles Jig System Surgical Technique

Surgical Sutures & Meshes. State of the art

Transcription:

Instructions for use DESCRIPTION: SUTURA Nonabsorbable surgical suture U.S.P Black Braided Silk. Silk suture is a nonabsorbable sterile surgical suture composed of an organic protein called fibroin. This protein is derived from the domesticated species of the family Bombycidae. Silk for braided material is processed to remove the natural waxes and gums. Braided Silk is coated with wax and is available dyed in black with Sulphol Black 1 (Colour Index Number 53185). Silk sutures are available in range of gauge sizes and lengths, non needled or attached to stainless steel needles of varying types, sizes and shapes. The needles are attached permanently to the suture. Entire details of the product range are available in the catalogue. Sutura complies with the requirements of the United States Pharmacopoeia monograph for Nonabsorbable surgical suture and the European Pharmacopeia for Sterile Braided Silk Suture. INDICATIONS: Sutura is indicated for use in general soft tissue approximation and/or ligation in all surgical procedures excluding use in cardiovascular, ophthalmic and neurological procedures. APPLICATIONS: Sutures should be selected and implanted depending on the patient s condition, surgical experience, surgical technique and wound size. PERFORMANCE: Silk suture elicits an initial inflammatory reaction in tissues which is followed by gradual encapsulation of the suture by fibrous connective tissue. While Silk is not absorbed, progressive degradation of the proteinaceous Silk fiber in vivo may result in gradual loss of the entire tensile strength over time. CONTRA INDICATIONS: The use of this suture is contraindicated in patients with known sensitivities or allergies to Silk. Due to gradual loss of tensile strength which may occur over prolonged periods in vivo, silk sutures should not be used where permanent retention of tensile strength is required. Do not expose the pack to chemical disinfectants containing oxidizing agents like Hydrogen Peroxide or other similar chemicals which may affect the product quality. Doc no: IFU/BBS Issue date: 1.6.2011 Rev no: 04 Rev date: 11.4.2016 1

WARNINGS/PRECAUTIONS/INTERACTIONS User should be familiar with surgical procedures and techniques involving non absorbable sutures before employing Silk suture for wound closure as risk of wound dehiscence may vary with the site of application and the suture material used. As with any foreign body, prolonged contact of any suture with salt solutions, such as those found in the urinary or biliary tracts may result in calculus formation. Adequate knot security requires the standard surgical technique of flat and square ties with additional throws as indicated by surgical circumstances and the experience of the surgeon. Acceptable surgical practice should be followed for the management of infected or contaminated wounds. When handling this suture or any other suture, care should be taken to avoid damaging the surface of the material with surgical instruments as this could lead to fracture of the material in use. Avoid crushing or crimping damage due to application of surgical instruments such as forceps or needle holders. Care should be taken to avoid damage while handling surgical needles. Grasp the needle in an area, one third (1/3) to one half (1/2) of the distance from the attachment end to the point. Grasping in the point area could impair the penetration performance and cause fracture of the needle. Grasping at the butt or attachment end could cause bending or breakage. Reshaping the needles may cause them to loose strength and make less resistant to bending and breaking. Users should exercise caution when handling surgical needles to avoid inadvertent needle stick injury. Discard the needles after use in container labeled as SHARPS ADVERSE REACTIONS: Adverse reactions associated with the use of this device include: allergic response in patients known to be sensitive to Silk, initial inflammatory tissue reaction and transient local irritation at the wound site. Like all foreign bodies Silk suture may potentiate an existing infection. STERILITY Sutura sutures are sterilized by ethylene oxide. Do not re sterilize. Do not use if package is opened or damaged. Discard opened unused sutures. STORAGE Recommended storage condition is to store at temperature between 10 C and moisture and direct heat. Do not use after expiry date. 35 C, away from DISPOSAL: Discard used sutures and needles contaminated with blood in the container meant for infectious waste. Unused expired pouches should be incinerated. Doc no: IFU/BBS Issue date: 1.6.2011 Rev no: 04 Rev date: 11.4.2016 2

TECHNIQUE FOR OPENING THE TEAR OPEN PACK: 1. The scrub nurse should hold the sterile pack in left hand with the color coded top facing her. The notch will be located at the top right. 2. Holding the pack with the left hand, tear the foil with the right hand thumb and fore finger at the notch position. Pull out the folder containing the needled suture with sterilized forceps. 3. Tear the folder till the needle is visible. Then with the help of sterilized forceps, withdraw the needled suture. For non needled suture, pull out the entire folder from the pack, with the sterilized forceps, open the folder and retrieve the suture. Doc no: IFU/BBS Issue date: 1.6.2011 Rev no: 04 Rev date: 11.4.2016 3

TECHNIQUE FOR OPENING THE PEEL OPEN PACK 1. Hold the pack in an upright manner and see the peel logo. 2. Hold the protruded portions of the aluminum foils and peel open till the needle fixed on the paper folder is visible. 3. With the help of sterilized forceps pull out the needled suture from the folder by grasping the needle, at one third and one half distance away from the swaged end. Doc no: IFU/BBS Issue date: 1.6.2011 Rev no: 04 Rev date: 11.4.2016 4

SYMBOLS USED ON THE LABELS: Do not re use Batch number Date of manufacture Date of expiry Sterilized by Ethylene Oxide Temperature limitation Do not use if package is damaged or opened Registered CE logo EU REPRESENTATIVE Do not re sterilize Consult instructions for use Avoid direct sunlight Avoid Moisture MANUFACTURER: FUTURA SURGICARE PVT LTD, 86/C 2, 3 rd Main, 2 nd Stage, Yeshwanthpur Industrial Suburb, Bangalore 560022, India. EC REPRESENTATIVE: MT Promedt Consulting GmbH, Altenhofstr. 80, 66386, St Ingbert, Germany, Tele: 0049 6894581020, email: info@mt procons.com Doc no: IFU/BBS Issue date: 1.6.2011 Rev no: 04 Rev date: 11.4.2016 5