Product documentation

Similar documents
Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

1 Safety instructions. 2 Device components. 3 Function. KNX Heating actuator 6gang RMD 230 V. Order-No. :

instabus EIB product documentation

Electrical devices may only be mounted and connected by electrically skilled persons.

Instruction manual. art Installation manual

Operating instruction

Operating Instructions. Combination sensor

Rev Product Manual ABB i-bus KNX. Heating actuator 1gang with 6164/11 U-500. Power and productivity for a better world TM

KNX Powerline PL 110. KNX Association

KNX LineCoupler 650 (Art. # 5233) Compact KNX Line Coupler TP/TP

Compact KNX Line Coupler TP/TP User manual

Operating Instructions. EnOcean radio wall transmitter

KNX Room temperature controller

Operating instructions Flat-Type Wall-Mounted Radio Control

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Installer manual inputs/outputs interface for led KNX

Operating Instructions Wind Sensor with Heating Heating Transformer Rain Sensor

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Electrical devices may only be mounted and connected by electrically skilled persons.

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

PHOENIX CONTACT - 03/2007

Electrical devices may only be mounted and connected by electrically skilled persons.

Thorsten Reibel, Training & Qualification Global Application and Solution Team

Product documentation

OUTPUT 5/24 VDC PWM/PT 2 CHANNEL. 1 Description. GFK-2761 May 2012

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

Instabus Radio Control Converter Installation Instructions

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

KNX manual 1-channel flush-mounted switch actuator SU 1

Fan Coil Actuator FCA 2

TA-Slider 160 KNX Protocol Implementation

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ABB i-bus KNX Meter Interface Module, MDRC ZS/S 1.1. Product Manual. Intelligent Installations Systems ABB

EIB/KNX Switch Actuators. User manual

ABB i-bus. KNX Weather Station WS/S Product Manual

Technical Manual MDT LED-Indicator

Functions module / Gateways Application Description Product Page KNX-GW-DMX-xxx DMX Gateway. KNX-GW-DMX Product Group 1

KNX TH65-AP. Thermo-Hygrometer. Installation and Adjustment. Item number 70184

K-BUS Switch Actuator

For controlling 4 independent shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop.

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

ACK. Menue. Channel 1 Alarm Channel 2 Ch 2. Outputs. Filter constant. Output: Current limit 0.11 A ± 10 % Int. voltage drop 2.5 V at max.

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

Radio remote control.

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

VARIO RTD 2. Function. I/O Extension Module With Two Analog Input Channels for the Connection of Temperature Shunts (RTD) User Manual

MU110-16R(K) Digital output module 16 channel. User guide

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

16-Channel Yearly Time Switch TR 648 S DCF

User Manual 3X300 DIMMER MODULE DM03B02KNX

Level Switch NRS 2-50 NRS Original Installation Instructions English

TA-Slider 160 KNX R24 Protocol Implementation

SWARCO TRAFFIC SYSTEMS GMBH. IG946 User Manual IG946_BE_10

KNX/EIB Product documentation

Fieldbus Independent I/O Modules Counter Modules , (/xxx-xxx) Manual

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

Universal Radio Cord Dimmer Order No.: Function

Meteodata 140 S weather station

MU110-8R(K) Digital output module 8 channel. User guide

IB IL TEMP 2 UTH. Function. INTERBUS Inline Terminal With Two Analog Input Channels for Measuring Temperature. Data Sheet 5722B

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Wireless valve actuator for bidirectional EnOcean communication. The SAB05 combines with message server and enocean transmitter.

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Radio Management. Radio Management Controller. Manual. Art.-no.: FMC 1000 GB J:

Air Quality Sensor KNX AQS

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

Brief description. Type overview

Control solutions Biofloor

CU-DIN DIM 6-CH 0 10V KNX

MK110-8D.4R. Digital I/O-Module 12 channel 8 DI, 4 DO. User guide

Operating Manual MU2000K

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

Application Description 81EU01-E/R3210. Input Module for. Analog Signals 5-fold, 0/ ma. Input, Output, Signal Conditioning.

Application Description

bks-3/ciu Extract from our online catalogue: Current to:

MODEL 8080PR3 Released on 11th Mar 2013

The AT4222 module is equipped with four inputs for PT100/PT1000 resistance temperature measurement.

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

Answering frequently asked Questions (Firmware V.107)

AG FB-CAN. Absolute encoder viva CAN. Product Manual E-V0204.doc

Electronic Circuit Breaker BASIC FIX

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

ABB i-bus KNX DALI Light Controller DLR/S M Product Manual

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Manual. Radio Control Central Unit

KNX weather station basic V2

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

MINI-PS AC/24DC/1.3

Transcription:

Product documentation Area/line coupler ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-2 04 kundencenter@jung.de www.jung.de Service Center Kupferstr. 17-19 44532 Lünen Germany Issue: 11.02.2013 60170321

Product documentation Contents 1 Product definition... 3 1.1 Product catalogue... 3 1.2 Function... 3 2 Installation, electrical connection and operation... 4 2.1 Safety instructions... 4 2.2 Device components... 5 2.3 Fitting and electrical connection... 7 3 Technical data... 9 4 Software description... 10 4.1 Software specification... 10 4.2 Application basics... 11 4.3 Software "Coupler/repeater 900F01"... 16 4.3.1 Scope of functions... 16 4.3.2 Parameters... 17 4.4 Software "Coupler/repeater 901011" (only ETS4)... 20 4.4.1 Scope of functions... 20 4.4.2 Parameters... 21 4.5 General notes... 27 5 Appendix... 28 5.1 Index... 28 Page 2 of 29

Product definition 1 Product definition 1.1 Product catalogue Product name: Area/line coupler Use: Design: Art.. System device RMD (rail-mounted device) 2142 REG 1.2 Function The backbone/line coupler interconnects two KNX lines into a logical function area ensuring at the same the electrical separation between these lines. Each bus line of a KNX installation can thus be operated electrically independently from other bus lines. The exact function of the device is determined by the selected parameterization and by the physical address. The device can be used as an backbone coupler, line coupler or line repeater for implementing line segments in existing new KNX installations. Used as a line coupler (LC) (physical address: X.X.0): Connection of a subordinate line (line) to a higher-order line (main line) optionally with and without filter function for group communication. The coupler is logically assigned to the subordinate line by way of its physical address. The coupler is supplied with power from the higher-level line (main line). Used as a backbone coupler (BC) (physical address: X.0.0) Connection of a subordinate line (main line) to a higher-order line (backbone bus) optionally with and without filter function for group communication. The coupler is logically assigned to the subordinate line by way of its physical address. The coupler is supplied with power from the higher-level line (backbone bus). Used as a line repeater (LR) (physical address: X.X.X): By using a line repeater, a line (64 devices max.) can be expanded by a further line segment (further 64 devices). With a maximum of 3 line repeaters in parallel per line, the highest maximum number of 256 devices in a line (including LRs) can then be realized. The line repeater has no filter tables so that all group telegrams will always be transmitted unfiltered. Each line (backbone bus, main line, line) or each line segment requires a separate power supply. There is a specific application program (coupler/repeater 901011) with extended functions for the ETS4 (from version 4.1). This supports the full address range (groups 0-31) for the filter function and includes additional parameters. Page 3 of 29

2 Installation, electrical connection and operation Installation, electrical connection and operation 2.1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. The applicable accident prevention regulations must be observed. Failure to observe the instructions may cause damage to the device and result in fire and other hazards. Page 4 of 29

Installation, electrical connection and operation 2.2 Device components 8 7 2 3 4 6 5 Figure 1: Device components (1) LED "RUN" (green): signals the ready-for-operation state of the backbone / line coupler. permanently OFF: device OFF, no power on higher-order line permanently ON: device ON, power on both lines flashing: device ON, no power on subordinate line (2) LED "HL" (yellow): receiving data on higher-order line (3) LED "UL" (yellow): receiving data on subordinate line (4) LED "DIAG" (red): telegram transmission in group communication (groups 0-13). Signalling is parameter-dependent. permanently OFF: Application coupler/repeater 900F01 The parameters "Group telegrams main line -> Line" and "Group telegrams line -> Main line" are parameterized to "block" or "filter". Application coupler/repeater 901011 The parameters "Group telegrams groups 0-13" for telegrams "Main line -> Line" and "Line -> Main line" are parameterized to "block" or "filter". In these cases, group telegrams of the groups 0-13 are filtered or blocked completely according to the filter table loaded depending on the parameterization. permanently ON: Application coupler/repeater 900F01 The parameters "Group telegrams main line -> Line" or "Group telegrams line -> Main line" are parameterized to "transmit unfiltered" or the device works as a line repeater. Application coupler/repeater 901011 The parameters "Group telegrams groups 0-13 for telegrams "Main line -> Line or Line -> Main line" are parameterized to "transmit unfiltered" or the device works as a line repeater. In these cases, group telegrams of the groups 0-13 (or all group addresses for parameterization as repeater) are always forwarded. (5) Bus connection terminal for subordinate line (UL) (6) Bus connection terminal for higher-order line (HL) (7) Programming LED (red) (8) Programming button Page 5 of 29

Installation, electrical connection and operation i The parameters "Group telegrams groups 14-31 for telegrams Main line -> Line" or "Line -> Main line" of the application coupler/repeater 901011 have no influence on the LED "DIAG". After complete start-up of the KNX installation, it is recommended to set the telegram transmission parameter to "Filter" and to load filter tables. Page 6 of 29

2.3 Fitting and electrical connection Installation, electrical connection and operation Fitting the device Observe the temperature range and ensure sufficient cooling, if necessary. o Mount device on DIN rail according to EN 60715 with the terminals facing downwards. i A KNX data rail is not required. Connecting the device (9) (10) Figure 2: Connection diagram (9) Connection higher-order line (10) Connection subordinate line o Connect the higher-order line to the left connection terminal HL (9). i This terminal supplies power to the device electronics. So that it is possible to report a bus voltage failure of the subordinate via the higher-order line. o Connect the subordinate line to the right connection terminal UL (10). i Do not lever out the connecting terminals from below during the dismantling of the device. Risk of shorting the bus voltage which is not available during the short-circuit. Assign physical address o Press the programming button (8). The programming LED (7) lights up and goes out on taking over of the physical address. Page 7 of 29

Installation, electrical connection and operation Hardware information - After switch-on or after applying the bus voltage from the higher-order line, an LED test is started. During this test, all LEDs are switched on briefly and then off again beginning with the uppermost LED ("RUN"). After this test, the device is ready for operation and the LEDs indicate the device status. - The filter tables are stored in a non-volatile memory (flash). This means that the stored addresses are not lost after a bus voltage failure and that no internal backup battery is required. Page 8 of 29

Technical data 3 Technical data Mark of approval Protection class KNX Rated voltage KNX Current consumption Current consumption Connection mode KNX KNX/EIB III DC 21... 32 V SELV approx. 8 ma (Subordinate line) approx. 6 ma Standard terminal Ambient conditions Storage/transport temperature -25... +70 C Ambient temperature -5... +45 C Housing Fitting width 36 mm / 2 modules Page 9 of 29

Software specification 4 Software description 4.1 Software specification ETS search paths: Configuration: System components / Line coupler / Area/line coupler S-mode standard Applications:. Short description Name Version from mask version 1 Line/backbone coupler Coupler/repeater 900F01 0.1 912 2 Line/backbone coupler (only for ETS4 version 4.1 and onwards) Coupler/repeater 901011 1.1 912 Using the application programs The differences in the range of functions and the parameterization of the application programs "Coupler/Repeater 900F01" and "Coupler/Repeater 901011" (only for ETS4) are listed below. These differences should be noted when using and particularly when interchanging the applications among each other. Application coupler/repeater 900F01 - The filter function (filter table) supports the groups 0-13. The groups >13 can be blocked or forwarded separately by a parameter. - Physically addressed telegrams are always transmitted depending on the target and coupler address. The behaviour cannot be changed. - Telegram repetitions in case of transmission errors for group telegrams and physically addressed telegrams must be activated (max. 3 repetitions) or deactivated separately. A separate setting for broadcast telegrams is not possible. Broadcast telegrams in case of transmission errors are handled like group telegrams. - Telegram confirmations on a line for group telegrams and physically addressed telegrams ("always" or "only when forwarding") only mutually adjustable. Application coupler/repeater 901011 (from ETS4.1) - The filter function (filter table) supports the full address range (groups 0-31). The groups 0-13 and 14-31 are to be parameterized separately. - Physically addressed telegrams can optionally be transmitted unfiltered, blocked or filtered depending on the target and coupler address. The behaviour for each transmission direction can be adjusted separately. - Telegram repetitions in case of transmission errors for group telegrams, physically addressed telegrams and broadcast telegrams must be activated (max. 3 repetitions) or deactivated separately. - Telegram confirmations on a line for group telegrams and physically addressed telegrams ("always" or "only when forwarding") separately adjustable. For physically addressed telegrams the telegram confirmation on one line (main line or line) can additionally be parameterized to "always reject (NACK)!". In this parameter setting physical access (parameterization/commissioning) from this line to the coupler and the other line is no longer possible (protection function). i If the diagnostic function "Device info" is applied by the ETS2/ETS3 on a device that was previously commissioned with the ETS4 specific application coupler/repeater 901011 " (from ETS 4.1), then the data read out is invalid and does not correspond to the current parameterization of the device. The correct data is only read out via the diagnostic function "Device info" of the ETS4. Page 10 of 29

Application basics 4.2 Application basics The device can be used as a backbone or a line coupler or alternatively as a line repeater. The type of function depends on the assignment of the physical address and on the parameterization of the device (parameter "Function as"). Device working as a backbone / line coupler The backbone/line coupler interconnects two KNX lines into a logical function area ensuring at the same the electrical separation between these lines. Each bus line of a KNX installation can thus be operated electrically independently from other bus lines. With a coupler a distinction is made as to whether it forwards telegrams with the addressing via physical addresses (e.g. telegrams that are transmitted from the ETS to a device during a commissioning as in the case of an application download) or group telegrams (communication by means of group addresses during ongoing operation of a KNX installation, e.g. light switching). To forward physically addressed telegrams it is important that the coupler knows its own physical address and thus its 'line affiliation' is defined. The coupler compares the destination address of a received telegram with its own line address and transmits or does not transmit the telegram depending on the sending direction. This behaviour of the coupler is preset in the "coupler/repeater 900F01" application and cannot be changed. The behaviour is parameterizable in the specific ETS4 application "Coupler/Repeater 901011". With regard to the group communication the behaviour of the coupler can be configured depending on the sending direction. Thus, it either forwards all group telegrams or blocks them. During ongoing operation of a system, a filter table can be loaded into the coupler particularly to reduce the bus load on the lines. In the course of this, the coupler only forwards the group telegrams whose group address is entered in the filter table. The main groups "14" to "31" in the application coupler/repeater 900F01 are an exception to this. All addresses belonging to these main groups longer fit in the filter table due to the limited address size of the ETS2 and ETS3 on the basis of older types of couplers. These addresses can be blocked or forwarded separately by the parameter "Main group 14/15". The main groups 16-31 are also supported in the configuration as from ETS4. In this case, telegrams of the upper main groups (14-31) in the application program Coupler/Repeater 900F01 are blocked or forwarded by the parameter main group 14/15". It is only possible for the upper main groups to also be entered in the filter table and optionally filtered when the ETS4 specific application program "coupler/repeater 901011" is used. The filter table is generated by the ETS and programmed into the coupler during a download of the "application" or partial download of the "Group addresses". The coupler always forwards broadcast telegrams (e.g. ETS Management telegrams - check whether devices are in the programming mode etc.). Commissioning During commissioning of a project with backbone / line couplers, the following sequence of operations should be observed: - Project design of the KNX installation (physical addresses, group addresses, parameters) - At first, the physical addresses of the couplers and their application programs must be programmed and then the physical addresses of the other KNX devices. Thereafter, the applications can be loaded into the KNX devices (actuators, sensors, etc.). For testing of a KNX installation, especially in the modification phase before project design completion, it is recommended to set the parameters "Group telegrams main line -> line" and "Group telegrams line -> main line" of all backbone / line couplers at first to "Transmit all". This means that any programmed filter tables are not yet taken into account in the testing phase. Page 11 of 29

Application basics - The filter tables can then be generated on completion of project design and commissioning (in the ETS2 under menu item: Commissioning/Project design generating filter tables / ETS3 generates them automatically). - Finally, the filter tables should be programmed into the couplers. The filter tables are loaded automatically when the complete application is downloaded or also during partial programming of the "group addresses". Topology The backbone / line coupler transmits telegrams between a subordinate line and a higher-order line (line coupler: line - main line, backbone coupler: main line - backbone bus). In the project design phase, the function of the device is defined by the physical address as follows: - Backbone coupler (BC) A.0.0 (1 A 15) - Line coupler (LC) A.L.0 (1 A 15, 1 L 15) Each line has a power supply (PS) of its own and is electrically isolated from the bus. With line couplers, up to 15 lines can be grouped into an area. With backbone couplers (BC), up to 15 areas can be interconnected. From a logical point of view, backbone / line couplers are assigned to the pertaining subordinate line. The hierarchy of line and backbone couplers in a KNX system is thus as follows (figure 3). Page 12 of 29

Application basics Backbone bus PS 1 CH 1 BC 1.0.0 BC 2.0.0 Main line 1 Main line 2 PS 2 CH 2 PS 4 CH 4 LC 1.1.0 LC 2.1.0 DEV 1.1.1 DEV 2.1.1 PS 3 CH 3 DEV 1.1.2 PS 5 CH 5 DEV 2.1.2 DEV 1.1.64 DEV 2.1.64 BK = Backbone coupler LC = Line coupler CH = Choke DEV = Bus device PS = Power supply Figure 3: The hierarchy of line and backbone couplers in a KNX system i The coupler logics is supplied with electric power from the higher-order line. Function as an repeater The line repeater interconnects a KNX line with a line segment to form a logical functional area ensuring at the same the electrical separation between these partial areas. By using a line repeater, a line (64 devices max.) can be expanded by a further line segment (further 64 devices). With a maximum of 3 line repeaters in parallel per line, the highest maximum number of 256 devices in a line (including LRs) can then be realized. The line segments can be operated electrically independently of one another. A line repeater either transmits telegrams using addressing by means of physical addresses (e. g. during start-up) or group telegrams (e.g. communication via group addresses during regular operation of a KNX installation). The line repeater has no filter tables so that all group telegrams will always be transmitted unfiltered. To forward physically addressed telegrams it is important that the coupler knows its own physical address and thus its 'line affiliation' is defined. The coupler compares the destination address of a received telegram with its own line address and transmits or does not transmit the Page 13 of 29

Application basics telegram depending on the sending direction. This behaviour of the coupler is part of its fixed program and cannot be changed. A line repeater always forwards broadcast telegrams. Connecting several line repeaters in series is not permitted. Commissioning During commissioning of a project with line repeaters, the following sequence of operations should be observed: - Project design of the KNX installation (physical addresses, group addresses, parameters) - As a first step, program the physical addresses of the backbone / line couplers, if any. - Then, program the physical addresses of the line repeaters and their application programs. - Transfer the application programs of the couplers. - As a last step, program the physical addresses of the other KNX devices. Thereafter, the applications can be loaded into the KNX devices (actuators, sensors, etc.). The line repeater can be programmed from the higher-order and also from the subordinate line. Topology To connect more than 64 devices to a line, line repeater (LR) can be used to create 4 line segments max. each of which can accommodate up to further 64 devices. Each line or each line segment has a power supply (PS) of its own and is electrically isolated from the other line segments. The line repeater transmits telegrams between the different line segments without filtering the group communication. In the project design phase, the function of the device is defined by the physical address (A.L.D) as follows: - 0 A 15-0 L 15-1 D 255 Line repeaters must be connected in parallel since a telegram is routed due to the routing counter via 6 couplers max. (LR-LC-BC-BC-LC-LR). The hierarchy of a line with 4 line segments max. is thus as follows (figure 4). Page 14 of 29

Application basics Mainline PS 1 CH 1 LC 1.1.0 Line 1 (Line segment 1) DEV 1.1.1 PS 2 CH 2 DEV 1.1.63 Line segment 2 Line segment 3 Line segment 4 LR 1.1.64 LR 1.1.128 LR 1.1.192 DEV 1.1.65 DEV 1.1.129 DEV 1.1.193 PS 3 CH 3 DEV 1.1.127 PS 4 CH 4 DEV 1.1.191 PS 5 CH 5 DEV 1.1.255 LC = Line coupler LR = Line repeater CH = Choke DEV = Bus device PS = Power supply Figure 4: The hierarchy of a line with 4 line segments max. i The repeater logic is supplied with electric power from the higher-order line. Page 15 of 29

Software "Coupler/repeater 900F01" Scope of functions 4.3 Software "Coupler/repeater 900F01" 4.3.1 Scope of functions The device can be parameterized as a coupler or as an repeater. Function as coupler: - Depending on the physical address, use as line or area coupler - Reduced bus load due to filter function (filter table) if used as a coupler - Forwarding of group telegrams (Line -> Main Line, Main Line -> Line) parameterizable - Telegram repetitions in case of transmission errors presettable - Telegram confirmation parameterizable Function as an repeater: - Expansion of a line into a maximum of 4 line segments with up to 64 devices per segment - Telegram repetitions in case of transmission errors presettable Page 16 of 29

Software "Coupler/repeater 900F01" Parameters 4.3.2 Parameters Description Values Comment h Configuration Function as Area / Line coupler Repeater This parameter defines the functions of the device. In addition, it is important to assign a correct physical address corresponding to the functions of the device. (cf. functional description). h Selection (for configuration as "Backbone / line coupler") Group telegrams main line -> line block transmit unfiltered filter Defines whether group telegrams from the higher-order line (main line) are transmitted to the subordinate line (line). All group telegrams will be blocked. group telegram can pass the coupler. All group telegrams will be transmitted. The filter table will be disregarded. In accordance with the filter table generated and programmed in the ETS, group telegrams are either transmitted or blocked selectively. This parameter influences the behaviour of the red diagnosis LED. As soon as this parameter is set to "transmit unfiltered", the LED is lit up. Group telegrams line -> main line block transmit unfiltered filter Defines whether group telegrams are transmitted from the subordinate line (line) to the higher-order line (main line). All group telegrams will be blocked. group telegram can pass the coupler. All group telegrams will be transmitted. The filter table will be disregarded. In accordance with the filter table generated and programmed in the ETS, group telegrams are either transmitted or blocked selectively. This parameter influences the behaviour of the red diagnosis LED. As soon as this parameter is set to "transmit unfiltered", the LED is lit up. group telegrams on higher-order line A group telegram transmitted by the coupler is checked for transmission errors. signal on the higher-order line (HL). Page 17 of 29

physical addressing on higher-order line group telegrams on subordinate line physical addressing on subordinate line Main group 14/15 block transmit all Software "Coupler/repeater 900F01" Parameters A telegram with physical addressing transmitted by the coupler is checked for transmission errors. This parameter determines whether the telegram is to be repeated on reception of a BUSY or a NACK confirm signal or in the absence of the ACK confirm signal on the higherorder line (HL). A group telegram transmitted by the coupler is checked for transmission errors. signal on the subordinate line (SL). A telegram with physical addressing transmitted by the coupler is checked for transmission errors. signal on the subordinate line (SL). All addresses belonging to the main groups 14 and 15 no longer fit into the filter table due to the limited address size of the ETS2 and ETS3 and the older types of couplers. Such addresses can be blocked or forwarded separately by this parameter. The main groups 16-31 are also supported in the configuration as from ETS4. In this case, telegrams of the upper main groups (14-31) are blocked or forwarded by this parameter. All group telegrams with the main group 14 to 31 are blocked. All group telegrams with the main group 14 to 31 are forwarded. This parameter has no influence the behaviour of the red diagnosis LED. Telegram confirmation on main line always only if transmitted This parameter defines the cases in which the device confirms the telegrams received on the main line / backbone bus. The coupler always confirms on the higher-order line every telegram received. The coupler confirms on the higherorder line only the telegrams transmitted to the subordinate line. Page 18 of 29

Telegram confirmation on line always only if transmitted Software "Coupler/repeater 900F01" Parameters This parameter defines the cases in which the device confirms the telegrams received on the subordinate line. The coupler always confirms on the higher-order line every telegram received. The coupler confirms on the higherorder line only the telegrams transmitted to the subordinate line. h Selection (for configuration as "Repeater") group telegrams on higher-order line A group telegram transmitted by the coupler is checked for transmission errors. signal on the higher-order line (HL). physical addressing on subordinate line group telegrams on subordinate segment physical addressing on subordinate segment A telegram with physical addressing transmitted by the coupler is checked for transmission errors. signal on the higher-order line (HL). A group telegram transmitted by the coupler is checked for transmission errors. signal on the subordinate segment (UL). A telegram with physical addressing transmitted by the coupler is checked for transmission errors. signal on the subordinate segment (UL). Page 19 of 29

4.4 Software "Coupler/repeater 901011" (only ETS4) 4.4.1 Scope of functions The device can be parameterized as a coupler or as an repeater. Software "Coupler/repeater 901011" (only ETS4) Scope of functions Function as coupler: - Depending on the physical address, use as line or backbone coupler - Reduced bus load due to filter function (filter table) if used as a coupler - Support of the full address range (groups 0-31) for filter function - Forwarding of group telegrams (Line -> Main Line, Main Line -> Line) parameterizable - Forwarding of physically addressed telegrams (Line -> Main Line, Main Line -> Line) parameterizable - Telegram repetitions in case of transmission errors for group, broadcast and physically addressed telegrams presettable separately - Telegram confirmation for group and physically addressed telegrams separately parameterizable Function as an repeater: - Expansion of a line into a maximum of 4 line segments with up to 64 devices per segment - Telegram repetitions in case of transmission errors for group, broadcast and physically addressed telegrams presettable separately Page 20 of 29

Software "Coupler/repeater 901011" (only ETS4) Parameters 4.4.2 Parameters Description Values Comment h Configuration Function as Backbone / Line coupler Repeater This parameter defines the functions of the device. In addition, it is important to assign a correct physical address corresponding to the functions of the device. (cf. functional description). h Selection (for configuration as "Backbone / line coupler") Telegrams Main line -> line group telegrams groups 0-13 Defines whether group telegrams of the groups 0-13 from the higher-order line (main line) are transmitted to the subordinate line (line). transmit unfiltered All group telegrams of the groups 0-13 are transmitted. The filter table will be disregarded. block All group telegrams of the groups 0-13 are blocked. group telegram of the groups 0-13 can pass the coupler. filter In accordance with the filter table generated and programmed in the ETS, group telegrams of the groups 0-13 are either transmitted or blocked selectively. This parameter influences the behaviour of the red diagnosis LED. As soon as this parameter is set to "transmit unfiltered", the LED is lit up. Telegrams Main line -> line group telegrams groups 14-31 Defines whether group telegrams of the groups 14-31 from the higher-order line (main line) are transmitted to the subordinate line (line). transmit unfiltered All group telegrams of the groups 14-31 are forwarded. The filter table will be disregarded. block All group telegrams of the groups 14-31 are blocked. group telegram of the groups 14-31 can pass the coupler. filter In accordance with the filter table generated and programmed in the ETS, group telegrams of the groups 14-31 are either transmitted or blocked selectively. This parameter does not influence the behaviour of the red diagnosis LED. Telegrams Main Line -> Line physically addressed telegrams Defines whether physically addressed telegrams from the higher-order line (main line) are transmitted to the subordinate line (line). Page 21 of 29

Software "Coupler/repeater 901011" (only ETS4) Parameters transmit unfiltered block filter (depending on target & coupler address) All physically addressed telegrams are transmitted. All physically addressed telegrams are blocked. physically addressed telegram can pass the coupler. Only physically addressed telegrams are transmitted whose target address matches the line address of the coupler. All other physically addressed telegrams are blocked. Telegrams Line -> Main line group telegrams groups 0-13 Telegrams Line -> Main line group telegrams groups 14-31 Defines whether group telegrams of the groups 0-13 from the subordinate line (line) are transmitted to the the higherorder line (main line). transmit unfiltered All group telegrams of the groups 0-13 are transmitted. The filter table will be disregarded. block All group telegrams of the groups 0-13 are blocked. group telegram of the groups 0-13 can pass the coupler. filter In accordance with the filter table generated and programmed in the ETS, group telegrams of the groups 0-13 are either transmitted or blocked selectively. This parameter influences the behaviour of the red diagnosis LED. As soon as this parameter is set to "transmit unfiltered", the LED is lit up. Defines whether group telegrams of the groups 14-31 from the higher-order line (main line) are transmitted to the subordinate line (line). transmit unfiltered All group telegrams of the groups 14-31 are forwarded. The filter table will be disregarded. block All group telegrams of the groups 14-31 are blocked. group telegram of the groups 14-31 can pass the coupler. filter In accordance with the filter table generated and programmed in the ETS, group telegrams of the groups 14-31 are either transmitted or blocked selectively. This parameter does not influence the behaviour of the red diagnosis LED. Telegrams Line -> Main Line physically addressed telegrams transmit unfiltered Defines whether physically addressed telegrams from the subordinate line (line) are transmitted to the higher-order line (main line). All physically addressed telegrams are transmitted. Page 22 of 29

Software "Coupler/repeater 901011" (only ETS4) Parameters group telegrams on higher-order line broadcast telegrams on higher-order line physically addressed telegrams on higherorder line group telegrams on subordinate line broadcast telegrams on subordinate line physically addressed block filter (depending on target & coupler address) All physically addressed telegrams are blocked. physically addressed telegram can pass the coupler. Only physically addressed telegrams are transmitted whose target address does not match the line address of the coupler. Physically addressed telegrams whose target address match the coupler addres are blocked. A group telegram transmitted by the coupler is checked for transmission errors. signal on the higher-order line (HL). A broadcast telegram transmitted by the coupler is checked for transmission errors. signal on the higher-order line (HL). A telegram with physical addressing transmitted by the coupler is checked for transmission errors. signal on the higher-order line (HL). A group telegram transmitted by the coupler is checked for transmission errors. signal on the subordinate line (SL). A broadcast telegram transmitted by the coupler is checked for transmission errors. signal on the subordinate line (SL). A telegram with physical addressing transmitted by the coupler is checked for transmission errors. Page 23 of 29

Software "Coupler/repeater 901011" (only ETS4) Parameters telegrams on subordinate line Telegram confirmation on main line Group telegrams Telegram confirmation on main line physically addressed telegrams Telegram confirmation on line Group telegrams Telegram confirmation on line physically addressed telegrams always only if transmitted always only if transmitted always reject (NACK)! always only if transmitted always only if transmitted signal on the subordinate line (SL). It is possible to define when the device confirms the group telegrams received on the higher-order main line / backbone bus. The coupler always confirms on the higher-order line every group telegram received. The coupler confirms on the higherorder line only those group telegrams transmitted to the subordinate line. It is possible to define when the device confirms the physically addressed telegrams received on the higher-order main line / backbone bus. The coupler always confirms on the higher-order line every physically addressed telegram received. The coupler confirms on the higherorder line only the physically addressed telegrams transmitted to the subordinate line. The coupler rejects on the higher-order line all physically addressed telegrams received and sends a NACK-Confirm. physically addressed telegram can pass the coupler. The coupler cannot be physically addressed from the higherorder line (no download possible). te: This setting cannot be parameterized on both lines. It is possible to define when the device confirms the group telegrams received on the subordinate line. The coupler always confirms on the subordinate line every group telegram received. The coupler confirms on the subordinate line only the group telegrams transmitted to the higher-order line. It is possible to define when the device confirms the physically addressed telegrams received on the subordinate line. The coupler always confirms on the subordinate line every physically addressed telegram received. The coupler confirms on the subordinate line only the physically addressed Page 24 of 29

Software "Coupler/repeater 901011" (only ETS4) Parameters always reject (NACK)! h Selection (for configuration as "Repeater") group telegrams on higher-order line broadcast telegrams on higher-order line physically addressed telegrams on higherorder line group telegrams on subordinate line broadcast telegrams on subordinate line physically addressed telegrams on subordinate line telegrams transmitted to the higherorder line. The coupler rejects on the subordinate line all physically addressed telegrams received and sends a NACK-Confirm. physically addressed telegram can pass the coupler. The coupler cannot be physically addressed from the subordinate line (no download possible). te: This setting cannot be parameterized on both lines. A group telegram transmitted by the coupler is checked for transmission errors. signal on the higher-order line (HL). A broadcast telegram transmitted by the coupler is checked for transmission errors. signal on the higher-order line (HL). A telegram with physical addressing transmitted by the coupler is checked for transmission errors. signal on the higher-order line (HL). A group telegram transmitted by the coupler is checked for transmission errors. signal on the subordinate line (SL). A broadcast telegram transmitted by the coupler is checked for transmission errors. signal on the subordinate line (SL). A telegram with physical addressing transmitted by the coupler is checked for transmission errors. Page 25 of 29

Software "Coupler/repeater 901011" (only ETS4) Parameters signal on the subordinate line (SL). Page 26 of 29

General notes 4.5 General notes General remarks - Deactivating the telegram repetition (repetition on reception of a BUSY or a NACK confirm signal or signal) of the device reduces the bus load but also reduces the transmission security. - The device can be programmed via the higher-order line or subordinate line (phys. address, filter tables, etc.). In addition, commissioning is possible from each line of the KNX installation. It should be noted that the higher-order line (HL) must be connected to bus voltage in order to program. Using old application programs and devices - It is possible to program the device described in this documentation with the product applications of the old 4 TE wide device ("Coupler 900501" / "Repeater 900701"). This might be necessary, for instance, when replacing an old coupler by a 2 TE wide coupler. In this case, the manufacturer-neutral dummy product database "LK_DUMMY.VD1" in the product management must first be imported in the ETS2 before commissioning the new coupler. Afterwards, the new device can be programmed with the physical address and old or existing filter table as well as with the existing parameters. An import of the dummy product database is not necessary in the ETS3. - Furthermore, the device described in this documentation can be programmed with the product applications of the older 2 TE wide device ("Coupler 900A01" / "Repeater 900B01"). tes: The parameters " transmission errors on main line" and "Repetitions in case of transmission errors on line" in the applications "Coupler 900501" or "Repeater 900701" can be set to the values "none", "1", "2" or "3". In the new device (2 TE wide) this results in the following reaction: Settings "none" and "1": no telegram repetition, Settings "2" or "3": 3 telegram repetitions. The parameters for the filter table check in the old application "Coupler 900501" show no reaction in the new coupler. The ETS possibly displays a message on function problems if old devices are programmed with the application Coupler/Repeater 900F01. This message can be ignored taking into account the above characteristics. The application program Coupler/Repeater 901011 can only be used as from ETS version 4.1 and it is not possible to program the older 2 TE and 4 TE wide devices with this application. Behaviour after bus voltage failure Higher-order line: The device is not functional. All LEDs are off. Subordinate line: Functioning of the device on the higher-order line is not affected. Telegrams are evaluated, programming is possible, all LEDs are functional. Behaviour after bus voltage return After an initialization phase of ca. 1 s including the LED test, the device is ready to operate. Page 27 of 29

Appendix 5 Appendix 5.1 Index A application programs..... 10 B backbone / line coupler..... 11 bus voltage failure..... 27 bus voltage return..... 27 E ETS search paths..... 10 R repeater..... 13 Page 28 of 29

Appendix ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-2 04 kundencenter@jung.de www.jung.de Service Center Kupferstr. 17-19 44532 Lünen Germany Page 29 of 29