TDS 10. (Euro)DOCSIS cable modem TDS 10 with extension modules. For remote meter monitoring and reading

Similar documents
Smart Metering Modem Solutions BROADBAND

DOCSIS 1.0 Micro CMTS

System Specification. BreezeACCESS TM EZ. January 2008

TELESTE AC AMPLIFIER MODULES

B850 Boiler House Energy Monitor

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz

Monitoring Cable Technologies

Trio Q Data Radios. Licensed UHF Ethernet and Serial Data QR450

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

MATERIAL SPECIFICATIONS FOR WIRELESS LINK

Acterna DSAM Product Family

ACE3 INTELLIGENT BROADBAND AMPLIFIER

Trio Q. Licensed UHF Ethernet and Serial data radio. QB450 Full Duplex

ARP Radio Modem & Router Datasheet

TPNA Trilithic TPNA-1000 Specs Provided by Overview. Testing Features. Triple Play Network Analyzer

B850 Boiler House Energy Monitor

TELESTE AC NODE SPECIFIC MODULES

Smart Energy & Power Quality Solutions. Portable energy measurement devices COMPACT FLEXIBLE PRECISE

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

Trio Q. Licensed UHF Ethernet and Serial data radio. QH450 Hot Standby Full Duplex

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

NV-EC1701U. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

802.16s SOFTWARE PLATFORM

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

DS2500Q Digital TV QAM Analyzer

Side view View from below Rear view

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

NV-EC1701U. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd

DTMA-1800-UMTS-12-AISG

CX380X Advanced Spectrum and Burst QAM Analyzer

Remote Site Monitoring

AC3000 INTELLIGENT BROADBAND AMPLIFIER

CM /100/1000BASE-T

The Use of MESH Technology in Outside Broadcast

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

Data Sheet. Four Port PoE+ Receiver Model NV-ER1804. Application Example: Features:

Model NV-ER1808i TBus Eight Port Receiver Hub FRONT

CATV Product Family MEDIALINE 2000

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

RFID UHF Products 2010

PRODUCT CATALOGUE: March 2018

Smart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)

Model NV-ET1804 TBus Four Port PoE+ Transmitter with Four PoE, PoE+, or High Power PoE Ports

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

10/100 PoE+ NV-ER1808i or. NV-ER1816i

PQube 3 Specifications

NV-ET1801 or NV-ER1808i or. NV-ER1816i

DS2580C Digital TV QAM Analyzer

Communication by power line carrier technology. For medium voltage networks

UMG 509-PRO. Multifunction power analyser with RCM

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Model NV-ER1808i TBus Eight Port Receiver Hub

Radio Frequency Interface Specification SP-RFI-C Notice

BCL 500i bar code reader The new generation with a variety of integrated interfaces

DVB-T/H Portable Test Transmitter

innovative technology to keep you a step ahead Advanced Home Certification Capabilities Simplify Installation and Troubleshooting

MDW-45 Converter RS RS-422/485

TT-208. User s Manual. 300Mps 5.8 GHz. IP Camera Wireless Transmission Kit

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Airmux-400 Broadband Wireless Multiplexer

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

DTMA AISG. Fullband Double Dual Duplex Tower Mounted Amplifier (Masthead Amplifier)

NETWORK ANALYZERS Analyzers

Intermittent Vibration 0.075

Datasheet FibeAir IP-20S

Data Acquisition Modules/ Distributed IO Modules

Q.raxx A slimline RS / EC Universal Measurement System

Model NV-ER1816i TBus Sixteen Port Receiver Hub

LigoDLB MACH 5. 5 GHz high-capacity wireless device COPYRIGHT 2017 LIGOWAVE

DXR 200 migration. 4RF White Paper. Contents. July 2012, issue 1.2.0

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

RFID UHF Products 2011

Security of the entire mesh network can be ensured by the use of the optional AES128 or AES256 encryption.

M-Bus Master MultiPort 250L Installation and User Guide

ISOMETER IRDH575. Approvals

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

Point to Point PTP500

SmartAX MA5633 D-CCAP Head End Device

Connecting two Phoenix Studio Audiocodecs through a point-to-point IP radio link operating in the 5 GHz band

CXE880 FIBRE OPTIC NODE

Week 2 Lecture 1. Introduction to Communication Networks. Review: Analog and digital communications

Point-to-Multipoint Digital Link (MDL) Data Sheet N. Ultra High Spectral Efficiency, Very Low Latency UHF Radio for Mission Critical Applications

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

The coupling torque at 7-16 connectors is Nm! The tightning torque for fi xing the AISG connector must be Nm!

Ultra High Spectral Efficiency, Very Low Latency UHF Radio for Mission Critical Applications. Point-to-Multipoint Digital Link (MDL)

Model NV-EC1701 EoC Ethernet over Coax Transceiver with PoE, PoE+, or High Power PoE

Product Documentation

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

PTP 820S Licensed Microwave Radio

Mission Critical DAS Solution

100 BaseT transmission; Network speeds up to 93 Mbps*; Up to 8,000ft (2,500m)*


Videowave Wireless Video & Telemetry VTX1394SED & VRX1394SED

Model NV-ER1804 TBus Four Port Receiver

Power Meter Series PM3200 Functions and characteristics

QuidoDuplex. Two-state signal over-ethernet transmission set based on I/O module Quido. 12. July 2017 w w w. p a p o u c h. c o m

DS2500Q Digital TV QAM Analyzer

Transcription:

TDS 10 (Euro)DOCSIS cable modem TDS 10 with extension modules For remote meter monitoring and reading Low additional costs Easy installation of units 30 individual meters can be read with one device Monitoring of data transfer 99811859_EN.indd 1 22.03.2012 14:23:24

DOCSIS/EuroDOCSIS cable modem with M-Bus for smart metering The TDS 10 from Kathrein is a DOCSIS/EuroDOCSIS 2.0-compliant cable modem for installation rail mounting. It is designed to transmit data for remote meter reading. The TDS 10 automatically identifi es if the protocol is DOCSIS or EuroDOCSIS allowing easy commissioning without requiring manual intervention. The design has been specially optimised for installation in meter cabinets. The form of the housing and the mounting material fully meet the requirements for installation rail mounting components. The TDS 10 features an M-Bus master and is equipped with three M-Bus clamps which allow connection of up to 30 M-Bus clients (slaves). The clients are fed through the M-Bus; polarity is not to be taken into account when they are connected. The M-Bus is a robust two-wire bus designed for remote reading of the following reader types: - Heat meters - Water meters - Electricity meters - Gas meters The M-Bus can be designed as a tree or star structure. Normal telephone cables or category 5 cables can be used as cabling. Remote meter reading over an existing cable network Ethernet interface (local service interface) Three M-Bus interfaces in compliance with EN 13757, with screw terminals Connection of up to 30 meters Integrated M-Bus master Comprehensive SNMP management support: MIB-II; Ethernet-like MIB, Bridge MIB, Cable Device MIB, Baseline Privacy Interface MIB, RF Interface MIB Automatic switch-over to DOCSIS or EuroDOCSIS Easy installation on installation rails Easy registration onto DOCSIS or EuroDOCSIS CMTS without requiring any special hardware/software settings Integrated 230 VA C power supply with screw terminals (L, N, PE) Internal Web server for confi guration of the Ethernet interface (address: port: 192.168.100.1:81) M-Bus data transport: The headend queries meter data over the TDS 10 on TCP-Port 3007. The cable modem transacts the commands and the corresponding M-Bus protocol to the M-Bus over the serial interface. The received M-Bus data from the addressed meter is then transmitted back to the headend over the Ethernet interface (TCP) without interpretation by the TDS 10. In co-operation with the respective providers, this new modem opens the doors to totally new business models for cable operators. The TDS 10 M-Bus cable modem in use NE 4 M-Bus Power Plant Management HFC-Netz mit EuroDOCSIS CMTS Internet Internet VPN

Technical data Type TDS 10 Order no. 26210221 Receiver (downstream) Modulation 64/256 QAM Symbol rate DOCSIS MSym/s 5.057 (64 QAM)/5.361 (256 QAM) Symbol rate EuroDOCSIS MSym/s 6.952 (64 QAM)/6.952 (256 QAM) Frequency range MHz 90 to 862 Channel bandwidth DOCSIS/EuroDOCSIS MHz 6/8 Input level range dbμv 49 to 79 Input impedance Ω 75 Transmitter (upstream) Modulation TDMA QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM Symbol rate ksym/s 160, 320, 640, 1,280, 2,560 Frequency range MHz 5 to 65 Channel bandwidth khz 200, 400, 800, 1,600, 3,200, 6,400 Output level range dbμv 68 to 118 (TDMA: QPSK), 68 to 115 (TDMA: 16 QAM), 68 to 114 (TDMA: > 16 QAM), 68 to 113 (S-CDMA) Output impedance Ω 75 Network characteristics MAC protocol EuroDOCSIS 2.0/MCNS DOCSIS 2.0 Application protocol UDP, IP, ARP, ICMP, DHCP, TFTP, SNMP, http Management SNMP, MIB-II, Ethernet-like MIB, Bridge MIB, Cable Device MIB, Baseline Privacy Interface MIB, RF Interface MIB Safety Baseline Privacy/Baseline Privacy Plus Data fi ltering 32 Unicast addresses Connections To CATV network F-type socket To service PC RJ 45-10/100 BaseT (half/full duplex, auto-sensing) M-Bus interface V DC Three parallel-connected screw terminal pairs M-Bus idle mode, logical 1 V DC 36 M-Bus active mode, logical 0 V DC 22 Max. number of M-Bus clients, 1.5 ma each 30 Default baud rate (confi gurable via SNMP-OID) Baud 2,400 Max. bus length (JYSTY 2*0.8²) m 100 Voltage supply Supply voltage Screw terminals (L, N, PE) Nominal input voltage V AC 230 Power consumption (30 M-Bus clients connected) W 8.3 General Dimensions (W x H x D) mm 105 x 90 x 60 Operating temperature range C -5 to +50 Weight g Approx. 300 Protection class IP 20 Housing material Flammability rating All data are typical values unless stated otherwise. PC and ABS UL-94 standard

M-Bus Ethernet converter for TDS 10 TDA 10-CS TDA 10-232 26210694 26210700 TDA 10-CS, similar to picture The TDA 10-CS from Kathrein is an interface converter for bidirectional conversion of the M-Bus protocol into CS-Bus protocol and vice-versa. The Kathrein TDA 10-232 is an interface converter for bidirectional conversion of the M-Bus protocol into RS 232 protocol and vice-versa. The TDA 10-232 interface converter types are designed for interface conversion, extend the connection options of the TDS 10 on other interfaces beyond the M-Bus and are constructed for installation rail mounting. Different TDA 10 interface converter types can be connected to an M-Bus so that various interfaces can be operated with a TDS 10. When connecting the interface modules, observe the number of load units (M-Bus clients) that are limited by current drain. A TDS 10 can feed up to 30 load units. Remote meter reading over an existing cable network in conjunction with the TDS 10 Powering over M-Bus connection Easy installation on installation rails Available types: TDA 10-CS: Conversion of M-Bus protocol into CS-Bus protocol with independent data rates TDA 10-232: Conversion of the M-Bus protocol into the RS 232 protocol with independent data rates The interface modules EuroDOCSIS/HFC network M-Bus 230 VAC 99811859_EN.indd 4 CS-Bus RS 232 22.03.2012 14:23:44

Technical data Type TDA 10-CS TDA 10-232 Order no. 26210694 26210700 Connections Interface 1 M-Bus, one screw terminal pair Baud rate (default value = 2400 baud) Baud 2,400... 9,600 Interface 2 CS bus RS 232 interface (ehz) Baud rate (default value = 2,400 or 9,600 baud) Baud 300... 9,600 300... 9,600 Level for idle mode (logical 1 ) ma 17 - Level for active mode (logical 0 ) ma 4 - Max. reception data buffer kbyte 6 6 (3 for Push operation) CS voltage V 14 - Voltage supply Over the M-Bus Over the M-Bus Current drain from the M-Bus (for an M-Bus voltage of 36 V) ma 15 10 Load units on M-Bus 10 7 Number of slaves on interface 2 3 1 General Dimensions (W x H x D) mm 25 x 90 x 60 Operating temperature range C -5 to +50 LED signalling Operational voltage All data are typical values unless stated otherwise. Ethernet interface with an M-Bus interface for Smart Metering TDS 10-Eth The TDS 10-Eth from Kathrein is an Ethernet M-Bus interface with an integrated M-Bus master for installation rail mounting. It is designed to transmit M-Bus data over Ethernet data networks. The design has been specially optimised for installation in installation cabinets. The form of the housing and the mounting material fully meet the requirements for installation rail mounting components. The TDS 10-Eth features an M-Bus master and is equipped with three M-Bus clamps which allow connection of up to 30 M-Bus clients (meters or slaves). The clients are fed through the M-Bus; polarity is not to be taken into account when they are connected. The M-Bus is a robust two-wire bus designed for the transmission of various different measurement values and can be arranged as a tree or star structure. As a two-wire bus normal telephone cable or category 5 cable can be used. M-Bus data transport: The headend queries meter data over the TDS 10-Eth on TCP-Port 3007. The TDS 10-Eth transacts the commands and the corresponding M-Bus protocol to the M-Bus over the serial interface. The received M-Bus data from the addressed meter is then transmitted back to the headend over the Ethernet interface (TCP) without interpretation by the TDS 10-Eth. Remote transmission of M-Bus data over Ethernet data networks Ethernet interface (RJ 45) Three M-Bus interfaces in compliance with EN 13757, with screw terminals Comprehensive SNMP management support: MIB-II; Ethernet-like MIB, Bridge MIB, RS 232-MIB Integrated 230 V AC power supply with screw terminals (L, N, PE) Easy installation on installation rails Internal Web server for confi guration of the Ethernet interface (address: port: 192.168.100.1:81)

The interface modules M-Bus Ethernet CS-Bus RS 232 230 V AC 36 V 24 V -12 V Technical data Type TDS 10-Eth Order no. 26210702 Application protocol UDP, IP, ARP, ICMP, DHCP, TFTP, SNMP, http Management SNMP, MIB-II, Ethernet-like MIB, Bridge MIB, Baseline Privacy Interface MIB Safety Baseline Privacy/Baseline Privacy Plus Data fi ltering 32 Unicast addresses Connections Data network RJ 45-10/100 BaseT (half/full duplex, auto-sensing) M-Bus interface Three parallel-connected screw terminal pairs M-Bus idle mode, logical 1 V DC 36 M-Bus active mode, logical 0 V DC 22 Number of clients supplied (< 1.5 ma per client) 30 Default baud rate (confi gurable via SNMP-OID) Baud 2,400 Max. bus length (JYSTY 2*0,8²) m 100 Voltage supply Supply voltage Screw terminals (L, N, PE) Nominal input voltage V AC 230 Power consumption (30 M-Bus clients connected) W 8.3 General Dimensions (W x H x D) mm 105 x 90 x 60 Operating temperature range C -5 to +50 Weight g 270 Protection class IP 20 Housing material PC and ABS Flammability rating UL-94 standard All data are typical values unless stated otherwise.

DOCSIS/EuroDOCSIS cable modem with four 65 VAC monitoring inputs TDS 10-PWR The TDS 10-PWR from Kathrein is a DOCSIS/EuroDOCSIS 2.0-compliant cable modem for installation rail mounting. It is designed to transmit data during the monitoring of up to four remote-feed power supplies (65 VAC). Voltages are measured cyclically and can be read out. If voltages fall below a user-defined alarm threshold, an alarm will go off. Different correction factors for various curve forms (sine, trapezium, rectangle, etc.) can be entered into the MIB for correct display of voltages. The TDS 10-PWR automatically identifies if the protocol is DOCSIS or EuroDOCSIS allowing easy commissioning without requiring manual intervention. The design has been specially optimised for installation in installation cabinets. The form of the housing and the mounting material fully meet the requirements for installation rail mounting components. Remote reading of four AC voltage values over the existing cable network Ethernet interface (local service interface) Connection of up to four power supply lines using screw terminals (USV) with 65 VAC Easyy registration onto DOCSIS DOCS or EuroDOCSIS CMTS without requiring any special hardware/software settings Integrated 230 VAC power supply with screw terminals (L, N, PE) Easy installation on installation rails LEDs for: Downstream carrier search, modem ready for data traffic, Ethernet connection ok, measurement size alarm Measurement of up to four AC voltage signals (polling, cycle time < 5 seconds) Display of measured values in Kathrein-MIB with integration of SCTE-HMS-MIB for alarm thresholds The measured value is the rectified mean, using the correction factor for a sine wave (default). Many other curve forms with appropriate correction factors are available at a moment s notice. The earthing inputs E and the input PE are connected internally to the unit s secondary ground Comprehensive SNMP management support: MIB-II; Ethernet-like MIB, Bridge MIB, Cable Device MIB, Baseline Privacy Interface MIB, RF Interface MIB Automatic switch-over to DOCSIS or EuroDOCSIS The interface modules EuroDOCSIS/HFC network Monitoring of 5... 90 VAC 230 VAC 99811859_EN.indd 7 22.03.2012 14:24:43

Technical data Type TDS 10-PWR Order no. 26210712 Receiver (downstream) Modulation 64/256 QAM Symbol rate DOCSIS MSym/s 5.056941 (64 QAM)/5.360537 (256 QAM) Symbol rate EuroDOCSIS MSym/s 6.952 (64 QAM)/6.952 (256 QAM) Frequency range MHz 90 to 862 Channel bandwidth DOCSIS/EuroDOCSIS MHz 6/8 Input level range dbμv 49 to 79 Input impedance Ω 75 Transmitter (upstream) Modulation TDMA S-CDMA QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM QPSK, 8 QAM, 16 QAM, 32 QAM, 64 QAM, 128 QAM Symbol rate ksym/s 160, 320, 640, 1,280, 2,560 Frequency range MHz 5 to 65 Channel bandwidth khz 200, 400, 800, 1,600, 3,200, 6,400 Output level range dbμv 68 to 118 (TDMA: QPSK), 68 to 115 (TDMA: 16 QAM), 68 to 114 (TDMA: > 16 QAM), 68 to 113 (S-CDMA) Output impedance Ω 75 Network characteristics MAC protocol Excentis EuroDOCSIS 2.0/MCNS DOCSIS 2.0 Application protocol UDP, IP, ARP, ICMP, DHCP, TFTP, SNMP, http Management SNMP, MIB-II, Ethernet-like MIB, Bridge MIB, Cable Device MIB, Baseline Privacy Interface MIB, RF Interface MIB Safety Baseline Privacy/Baseline Privacy Plus Data fi ltering 32 Unicast addresses Max. number of 65/230 V AC lines to be monitored 4 Connections Ethernet port RJ 45 10/100 BaseT (half/full duplex, auto-sensing) Measurement interface V rms, Sine 5... 65... 90 Number of independent measurement inputs 4 Measurement accuracy %, Sine 4 Lightning arrester kv 1.5 Over-voltage resistance V AC rms 140 To CATV network F-type socket Voltage supply Supply voltage Screw terminals (L, N, PE) Nominal input voltage V AC 230 Power consumption W Typ. 3.5 General Dimensions (W x H x D) mm 105 x 90 x 60 Operating temperature range C -5 to +50 Protection class IP 20 Housing material PC and ABS Flammability rating UL-94 standard 99811859/1/0312/ZWD/Ri Technical data subject to change. Technical data represent typical values. All data are typical values unless stated otherwise. www.kathrein.de E-mail: catv@kathrein.de KATHREIN-Werke KG Phone +49 8031 184-0 Fax +49 8031 184-385 Anton-Kathrein-Straße 1-3 P.O. Box 10 04 44 83004 Rosenheim/GERMANY