Multivariate Regression Algorithm for ID Pit Sizing

Similar documents
Electromagnetic Eddy Current Sensors for Evaluation of Sea-Cure and 2205 Duplex Condenser Tubing

Developments in Electromagnetic Inspection Methods II

ADVANCED COMBINATION PROBE FOR TESTING FERRITIC SEA-CURE CONDENSER TUBING

2.5D Finite Element Simulation Eddy Current Heat Exchanger Tube Inspection using FEMM

DATA ANALYSIS ALGORITHMS FOR FLAW SIZING BASED ON EDDY CURRENT ROTATING PROBE EXAMINATION OF STEAM GENERATOR TUBES

D DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction

Developments in Electromagnetic Inspection Methods I

Simulation Model for SG Eddy Current SG Inspection

IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES USING REMOTE FIELD EDDY CURRENT

Eddy Current Signal Analysis Techniques for Assessing Degradation of Support Plate Structures in Nuclear Steam Generators

COMPUTER MODELING OF EDDY CURRENT TRANSMIT-RECEIVE PROBES FOR. S.P. Sullivan, V.S. Cecco, L.S. Obrutsky, D. Humphrey, S.P. Smith and K.A.

Modelling III ABSTRACT

Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures

High-Precision Internal Diameter Measurements Using Eddy Current Arrays

EDDY CURRENT INSPECTION MODELLING OF THE ELBOW OF A STEAM GENERATOR TUBE WITH THE FINITE ELEMENT SOFTWARE «FLUX»

Steam Generator Tubing Inspection

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

Eddy-Current Signal Interpretation Using Fuzzy Logic Artificial Intelligence Technique

Testing Critical Medical Tubing Using High Frequency Eddy Current Coils

Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT)

Multiple Frequency Eddy Current Technique

R&D of Multi-Frequency ECT Algorithms for FBR SG Tubes

EDDY CURRENT TECHNOLOGY FOR HEAT EXCHANGER AND STEAM GENERATOR TUBE INSPECTION

Effect of fatigue crack orientation on the sensitivity of eddy current inspection in martensitic stainless steels

AUTOMATED EDDY CURRENT DETECTION OF FLAWS IN SHOT-PEENED

A Method for Quantitative Analysis of Transient Eddy Current Testing

FLAW DETECTION USING ENCIRCLING COIL EDDY CURRENT SYSTEMS

BALANCE FIELD ELECTROMAGNETIC TECHNIQUE INSPECTION REPORT OF THE 8_INCH_1260_FITTING (HA-2/1200 BLOCK) TESTEX, INC. TESTED: JANUARY 9, 2019

Optimized Semi-Flexible Matrix Array Probes for Large Rotor Shafts and DGS Sizing Diagram Simulation Tool

EDDY CURRENT MEASUREMENT OF REMOTE TUBE POSITIONS IN CANDU REACTORS S.T. Craig, T.W. Krause, B.V. Luloff and J.J. Schankula Atomic Energy of Canada

DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER

INFLUENCE OF SIGNAL-TO-NOISE RATIO ON EDDY CURRENT SIGNALS OF CRACKS IN STEAM GENERATOR TUBES

Improvements to the Two-Thickness Method for Deriving Acoustic Properties of Materials

Target Temperature Effect on Eddy-Current Displacement Sensing

A Numerical Study of Depth of Penetration of Eddy Currents

Homework Assignment (20 points): MORPHOMETRICS (Bivariate and Multivariate Analyses)

DEVELOPMENT OF VERY LOW FREQUENCY SELF-NULLING PROBE FOR INSPECTION OF THICK LAYERED ALUMINUM STRUCTURES

Dynamic thresholding for automated analysis of bobbin probe eddy current data

MULTI-PARAMETER ANALYSIS IN EDDY CURRENT INSPECTION OF

Corrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing

EXTREME LOW FREQUENCY MAGNETIC IMAGING METHOD FOR DETECTION OF. Katsumi INOUE 2)

Instruction Manual Veritest

Magnetic Eddy Current (MEC) Inspection Technique

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE

BGA Solder Balls Formation by Induction Heating

EDDY CURRENT EXAM SIMULATION USING COUPLED FINITE ELEMENT/ VOLUME INTEGRAL OR FINITE ELEMENT/BOUNDARY ELEMENT METHOD

Signal Processing in an Eddy Current Non-Destructive Testing System

Amplitudes Variation of GPR Rebar Reflection Due to the Influence of Concrete Aggregate Scattering

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

Eddy Current Modelling for Fasteners Inspection in Aeronautic

Feasibility of Detection of Leaking Fuel Rods Using Side Coupled Guided Waves

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING

COVERING THICKNESS AND DIAMETER MEASUREMENT OF REINFORCING

DEFECT SIZING IN PIPE USING AN ULTRASONIC GUIDED WAVE FOCUSING TECHNIQUE

Developments in Ultrasonic Guided Wave Inspection

150Hz to 1MHz magnetic field coupling to a typical shielded cable above a ground plane configuration

WAVELET TRANSFORM BASED METHOD FOR EDDY CURRENT TESTING OF CLADDING TUBES

DETECTION OF SUB LAYER FATIGUE CRACKS UNDER AIRFRAME RIVETS

Application Information

EDDYCON C FOR AIRCRAFTS TESTING. CE MARKING

Induction heating of internal

Aries Center probe CSP socket Cycling test

Depth of Penetration Effects in Eddy Current Testing

2014 EDDY CURRENT BENCHMARK

AA&S Conference 2018 Eddy Current Array for Aircraft

Magnetic induction with Cobra3

EDDY CURRENT TESTING

Hybrid of Eddy Current Probe Based on Permanent Magnet and GMR Sensor

Dual Core Differential Pulsed Eddy Current Probe to Detect the Wall Thickness Variation in an Insulated Stainless Steel Pipe

FEM SIMULATION FOR DESIGN AND EVALUATION OF AN EDDY CURRENT MICROSENSOR

TIME-GATINGOF PULSED EDDY CURRENT SIGNALS FOR DEFECT CHARACTERIZATION AND DISCRIMINATION IN AIRCRAFT LAP-JOINTS

Ultrasonic Examination Of Tube To Tube Sheet Weld Joints In High Pressure Heat Exchanger For The Urea Process

Magnetic induction with Cobra3

Enhancement of the POD of Flaws in the Bulk of Highly Attenuating Structural Materials by Using SAFT Processed Ultrasonic Inspection Data

tas&m, INC., 107 Research Drive, Hampton, VA 23666

MultiScan MS 5800 Series

Improved Eddy Current Sensor for Hot Wire Inspection

AUTOMATED ANALYSIS OF EDDY CURRENT SIGNALS IN STEAM GENERATOR TUBE INSPECTION

Aries Kapton CSP socket Cycling test

ESA400 Electrochemical Signal Analyzer

warwick.ac.uk/lib-publications

DIAGNOSTIC OF CORROSION DEFECTS IN STEAM GENERATOR TUBES USING ADVANCED SIGNAL PROCESSING FROM EDDY CURRENT TESTING

Figure 4.1 Vector representation of magnetic field.

Automatic hardness testing devices

EDDYCON C AIRCRAFT SET OF EDDY CURRENT FLAW DETECTOR FOR AIRCRAFTS TESTING. CE MARKING

Design and Demonstration of a Passive, Broadband Equalizer for an SLED Chris Brinton, Matthew Wharton, and Allen Katz

Electron Spin Resonance v2.0

Application of SLOFEC and Laser Technology for Testing of Buried Pipes

MASSACHUSETTS INSTITUTE OF TECHNOLOGY HAYSTACK OBSERVATORY WESTFORD, MASSACHUSETTS

Long Range Ultrasonic Testing - Case Studies

Exp. #2-6 : Measurement of the Characteristics of,, and Circuits by Using an Oscilloscope

A Novel Forging Hammerhead Displacement Detection System Based on Eddy Current Sensor

DEFECT CHARACTERIZATION IN THICK COMPOSITES BY ULTRASOUND. David K. Hsu and Ali Minachi Center for NDE Iowa State University Ames, IA 50011

EC Test of welded Tubes. Edition 3 January 2003

RECENT ADVANCES AND IMPLEMENTATIONS OF FLEXIBLE EDDY. RJ. Filkins, J.P. Fulton, T.e. Patton, and J.D. Young

SIMPLIFIED COIL DESIGN (Part I) GE Ham News, Jan-Feb 1960 By B. H. Baidridge, W2OIQ

Non-destructive Inspection Technique for Assuring the High-end Quality of Our Pipe and Tube

EDDY CURRENT INSPECTION FOR DEEP CRACK DETECTION AROUND FASTENER HOLES IN AIRPLANE MULTI-LAYERED STRUCTURES

Surface-consistent phase corrections by stack-power maximization Peter Cary* and Nirupama Nagarajappa, Arcis Seismic Solutions, TGS

Transcription:

IV Conferencia Panamericana de END Buenos Aires Octubre 2007 Abstract Multivariate Regression Algorithm for ID Pit Sizing Kenji Krzywosz EPRI NDE Center 1300 West WT Harris Blvd. Charlotte, NC 28262 USA This paper presents status of an EPRI program to enhance and improve the reliability of ID pit sizing for balance-of plant heat exchangers, such as condensers and component cooling water heat exchangers found in a nuclear power plant. More traditional approaches to ID pit sizing involve the use of frequency-specific amplitude or phase angle analysis techniques. The multivariate regression algorithm for ID pit depth sizing incorporates simultaneous input parameters of frequency, amplitude, and phase angle. Summarized results of nondestructive evaluation (NDE) involving enhanced pit sizing from inside diameter (ID) of condenser tubing made of Type 304 stainless steel are presented. The latest analysis approach relied on both phase angle and amplitude information from multiple operating frequencies to better depth size ID-initiating pits. A total of 11 pits were selected for destructive analyses and a comparison made of the multivariate regression analysis results with the traditional univariate phase angle analysis results. The comparative results showed that the multivariate regression analysis produced better overall pit depth sizing results than the univariate phase angle-based sizing results. The selected pit samples for destructive sectioning showed a wide range of ground truth pit depth information, thus representing a good range of data set for validation. The statistically compared ground truth versus NDE estimates showed smaller overall mean regression error for depth sizing based on the multivariate regression analysis in comparison to the univariate phase angle analysis. Background The NDE method of multi-channel eddy current (EC) testing is an array of signals of up to 4 separate frequencies. An area of concern in Balance-of-Plant (BOP) heat exchanger tube NDE is ID pitting caused, for example, by microbiological organisms. The detection problem is to locate and discriminate the raw ID pit signal that is in the noisy EC tube signal trace. The sizing problem includes the measurement of the ID pit depth from the signal. The eddy current signal used in NDE is a complex impedance signal based on the applied induction bobbin coils. The signal is multi-channel in that it can be acquired at up to four separate frequencies. Each frequency has a different skin depth penetration, as predicted by Maxwell s Equations, and can provide different material property changes, including flaw conditions.

The complex signal for each frequency can be processed in Cartesian coordinate system of real (x) and imaginary (y) components, or complex Polar coordinate system. Typically, the signal of interest is displayed as a combination of the 2D Polar or Lissajous pattern and the X and Y strip charts. The signal of interest from which flaw depth estimates are made is the sharp transition line which is defined by the signal phase angle. This transition line is highlighted as thick lines in Figure 1. Figure 1 An ID Pit Signal Displayed as Complex Lissajous Pattern and by X and Y Strip Chart Components The feature extraction process will involve signal measurements from polar or Cartesian coordinates of the normalized signals. In signal normalization, a calibration target is scaled and rotated to an angle of 40 degrees from the 9:00 O clock position in the polar plane. This normalization is applied to all calibration signals. The traditional method of estimating ID Pit depth uses phase angle or amplitude, which represents a univariate depth estimation algorithm. The current EPRI project (1) involves a multivariate method and uses amplitude, phase, and XY Ratio (ratio of peak-to-peak resistance / inductance normalized to value > 1.0), all measured as a function of eddy current frequency. In Figure 1, a real field pit is shown in terms of phase angle and amplitude at 800 khz. IV Conferencia Panamericana de END Buenos Aires Octubre 2007 2

Multivariate Flaw Depth Regression Approach The multivariate flaw depth regression approach is to build a mapping function, F(x), that maps normalized features into ID pit depth, where x represents vector features and F() represents a linear or nonlinear function. For linear functions, F() is a 2 nd or 4 th order polynomial function in features. For the nonlinear functions, F() is a layered set of sigmoid functions trained with a multilayer perceptron. Only the linear F() mapping will be discussed in this paper. The approach for this ID pit depth sizing project was two-fold. The first was to construct multivariate depth regression functions for simulated but known size rounded and elongated ID pits in 0.75 and 1.0 diameter tubes, and compare the depth estimates with the univariate estimation method. This also allowed the fine-tuning of the regression functions by assessing the effect of pit morphology. The second approach was to use, directly or through an additional transformation, the rounded or elongated regression models to estimate the pit depth in the real field samples. Calibration Data Sets Tubing data for each calibration pit type were acquired four times by rotating the calibration tube at four different view angles of 3, 6, 9 and 12 O clock positions for both rounded and elongated pits with pit depths of 25, 50, 75 and 100 percent thru-wall depth. Data were acquired at eight different frequencies from low of 100 khz to high of 1MHz from both 0.75 OD and 1.0 OD tubing - only the 1.0 OD data will be used and discussed in this paper. Acquired data were displayed as an interactive 3D plot for this ID pit depth evaluation. The general display of the four elongated pit depths is shown in Figure 2. IV Conferencia Panamericana de END Buenos Aires Octubre 2007 3

Figure 2 3D Plots of Four Elongated Pit Depths Figure 2 showed the population of four different elongated pit depths in different colors. For each colored depth population, they represent raw data of three different size elongated pits at four different rotational positions at eight different operating frequencies. Basically, the compiled four elongated pit depth data are displayed in terms of operating frequencies, signal amplitudes, and phase angles. Raw individual data are shown as small crosses and the feature means and standard deviations are drawn as large crosses. Figure 3 displays the numerical results of a 4 th order polynomial multivariate regression algorithm that maps the feature vectors to elongated pit depth. Displayed in the regression analysis window are the mapping function and the bias and variance of the regressed depths compared to true calibration pit depths. As shown, the mean error for elongated pit depth estimation was around 6 percent. IV Conferencia Panamericana de END Buenos Aires Octubre 2007 4

Figure 3 Multivariate Regression Analysis based on the 4 th Order Polynomial Function Figure 4 shows the regression results from a 2 nd order univariate model using only phase angles from the elongated pits. For this univariate phase angle analysis, the frequencies were combined, whereas in the real field application, the phase angle-based pit depth estimation is conducted, for example, at a selected operating frequency of 600 khz. IV Conferencia Panamericana de END Buenos Aires Octubre 2007 5

Figure 4 Univariate Regression Analysis based on the 2 nd Order Phase Angle Function Based on the increased mean regression error of 17 percent, the multivariate method was shown to be superior to the univariate analysis method. The favorable results based on the elongated calibration pits were found to be equally applicable in evaluating the field pits. Evaluation of Field Data Sets Pit morphology (rounded vs. elongated) is a critical factor in the regression analysis. Building a higher order linear or a nonlinear multivariate regression function using combined rounded and elongated pits resulted in a larger mean error. This indicated that the sizing models for the two pit types are indeed different. The regression model selection based on either rounded or elongated pits is currently under development by considering the XY ratio function. For evaluating the field pits, an assumption was made that they were more elongated than rounded pits. The elongated calibrated pits presented ideal shapes and the field pits were modeled as an extension of the ideal pit shapes. Thus, to evaluate the field data, an algorithm that transformed the ideal elongated pit model, named as the Transformed Elongated Regression (TER) model, was developed and applied to the actual field pits. The TER is a first-order transformation of the depth estimate from the ideal elongated model. To develop this IV Conferencia Panamericana de END Buenos Aires Octubre 2007 6

transformation model, ten of the 12 field pit results were used. Figure 5 shows cross sections from several of the sectioned field pits showing the elongated nature of the field pits. Figure 5 Cross Sectional Views Showing Elongated Nature of Field Pits Evaluation Results A total of 12 pits were selected for destructive analyses and a comparison made of the TER analysis results with the traditional phase angle-based analysis results from the 600 khz data. Figures 6 and 7 provided NDE estimates to destructive estimates based on the two analysis methods. The comparative results clearly showed that the TER produced better overall pit depth sizing results than the univariate phase angle-based sizing results. The data samples showed a wide range of true depth, thus presenting a good data set for validation. The field analysis results confirmed the earlier results shown with the elongated calibration pits where multivariate regression resulted in smaller overall mean regression error for depth sizing in comparison to the univariate phase angle analysis. IV Conferencia Panamericana de END Buenos Aires Octubre 2007 7

Estimated Depth in % THRU-WALL 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Ground Truth IN % THRU-WALL Y =.773X+15.59 # Observed =11 Corr Coef =92.4% Y Mean =71.6% X Mean =72.5% Mean Error =-.9% Slope Error =-2.2% Std Y Error =8.1% RMSE =9.1% Ground Truth vs.estimated Best Fit Linear Line Figure 6 Transformed Elongated Regression Model Analysis Results Estimated Depth in % THRU-WALL 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Ground Truth IN % THRU-WALL Y =.097X+84.36 # Observed =11 Corr Coef =22.8% Y Mean =91.4% X Mean =72.5% Mean Error =18.8% Slope Error =-22.3% Std Y Error =10.4% RMSE =29.5% Ground Truth vs.estimated Best Fit Linear Line Figure 7 Univariate Phase Angle-Based Analysis Results IV Conferencia Panamericana de END Buenos Aires Octubre 2007 8

Summary The following observations are made based on the work done to date. Multivariate regression analysis was superior to traditional phase angle-based analysis Destructive sectioning of field pits confirmed the presence of more elongated pits with tunneled and cavernous pit morphology The multivariate regression analysis based on elongated pits represented more accurate pit depth sizing of actual field pits It should be noted that the developed analysis algorithm is damage- and eddy current dataspecific and as such similar but new algorithm need to be developed if any of the following parameters change. Different damage mechanism Different bobbin coil types, for example, use of low- or high-frequency probe versus intermediate-frequency probe Different fill-factor probes, for example, use of 80% versus 85% Finally, the developed regression-based algorithm needs to be further validated by comparing with actual field pits to ensure accuracy and applicability. Also, increasing the database and adding pit complexity will lead to model refinements and more robust pit depth estimation algorithms. Reference 1 K. Krzywosz, Nondestructive Evaluation: Enhnaced ID Pit Sizing of Heat Exchangers, EPRI Report, 1013454, November 2006. IV Conferencia Panamericana de END Buenos Aires Octubre 2007 9