Miniature SOP6-pin type with high capacity of A load current HE SOP Form A High Capacity (AQV G S). 6..7.8..8 6 mm inch FEATURES. High capacity in a miniature SOP package Continuous load current: Max. A Load voltage: V and 8V. Greatly improved specifications allow you to use this in place of mercury and mechanical relays. TYPICAL APPLICATIONS Security equipment Fire-preventing system Measuring instruments RoHS compliant TYPES AC/DC dual use Note: For space reasons, the two initial letters of the part number AQ and the packing style indicator X or Z are not marked on the device. * Indicate the peak AC and DC values. RATING Output rating* Load voltage Load current Package Tube packing style Part No. Surface-mount terminal Picked from the //-pin side Tape and reel packing style Picked from the //6-pin side V. A X Z SOP6-pin 8 V. A X Z. Absolute maximum ratings (Ambient temperature: C 77 F) Item Symbol Type of connection Tube tube contains: 7 pcs. batch contains:, pcs. Packing quantity Remarks Tape and reel LED forward current IF ma LED reverse voltage VR V Peak forward current IFP A f = Hz, Duty factor =.% Power dissipation Pin 7 mw, pcs. Load voltage (peak AC) VL V 8 V A. A. A Output Continuous load current IL B. A.7 A A connection: Peak AC, DC B, C connection: DC C 6. A. A Peak load current Ipeak 6 A A ms ( shot), VL = DC at A connection Power dissipation Pout mw Total power dissipation PT mw I/O isolation voltage Viso, Vrms Ambient temperature Operating Topr to +8 C to +8 F (Non-icing at low temperatures) Storage Tstg to + C to + F ASCTBE 7-T
HE SOP Form A High Capacity (AQV G S). Electrical (Ambient temperature: C 77 F) Output Transfer Item LED operate current LED turn off current LED dropout voltage Minimum Symbol Type of connection IFon IFoff Condition.6 ma. ma ma. ma. ma. ma VF. V (. V at IF = ma). V IL = ma IL = ma IF = ma. Ω.9 Ω A connection Ron A IF = ma, IL = Max..7 Ω. Ω Within s. Ω. Ω B connection On resistance Ron B IF = ma, IL = Max.. Ω. Ω Within s. Ω. Ω C connection Ron C IF = ma, IL = Max.. Ω. Ω Within s Off state leakage current ILeak μa IF = ma, VL = Max. Turn on time* Turn off time* Ton Toff. ms. ms IF = ma, IL = ma ms VL = V.8 ms. ms IF = ma, IL = ma. ms VL = V.8 pf f = MHz I/O capacitance Ciso. pf VB = V Initial I/O isolation resistance Minimum Riso, MΩ V DC Max. operating frequency. cps cps *Turn on/turn off time IF = ma, duty = % IL = Max., VL = Max. 9% Output % Ton Toff. Recommended operating conditions (Ambient temperature: C 77 F) Please use under recommended operating conditions to obtain expected. Item Symbol Min. Max. Unit LED current IF ma Load voltage (Peak AC) VL V Continuous load current (A connection) IL. A Load voltage (Peak AC) VL 6 V Continuous load current (A connection) IL. A These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation technical representative. ASCTBE 7-T
HE SOP Form A High Capacity (AQV G S) REFERENCE DATA.-() Load current vs. ambient temperature Sample: Allowable ambient temperature: to +8 C to +8 F 8.-() Load current vs. ambient temperature Sample: Allowable ambient temperature: to +8 C to +8 F. On resistance vs. ambient temperature Measured portion: between terminals and 6; LED current: ma; Load voltage: Max. (DC) Continuous load current: Max. (DC) Load current, A 6 C connection B connection A connection Load current, A C connection B connection A connection On resistance, Ω.8.6.. - - 6 8 8 - - 6 8 8 - - 6 8 8. Turn on time vs. ambient temperature LED current: ma; Load voltage: V (DC); Continuous load current: ma (DC). Turn off time vs. ambient temperature LED current: ma; Load voltage: V (DC); Continuous load current: ma (DC).. LED operate current vs. ambient temperature Load voltage: V (DC); Continuous load current: ma (DC) Turn on time, ms - - 6 8 8 Turn off time, ms.... - - 6 8 8 LED operate current, ma - - 6 8 8 6. LED turn off current vs. ambient temperature Load voltage: V (DC); Continuous load current: ma (DC) 7. LED dropout voltage vs. ambient temperature LED current: to ma 8. Current vs. voltage of output at MOS portion Measured portion: between terminals and 6; Ambient temperature: C 77 F LED turn off current, ma - - 6 8 8 LED dropout voltage, V..... - - 6 8 8 ma ma ma ma ma -.6 -. Current, A -... - Voltage, V - - -.6 ASCTBE 7-T
HE SOP Form A High Capacity (AQV G S) 9. Off state leakage current vs. load voltage Measured portion: between terminals and 6; Ambient temperature: C 77 F -. Turn on time vs. LED forward current Measured portion: between terminals and 6; Load voltage: V (DC); Continuous load current: ma (DC); Ambient temperature: C 77 F. Turn off time vs. LED forward current Measured portion: between terminals and 6; Load voltage: V (DC); Continuous load current: ma (DC); Ambient temperature: C 77 F. Leakage current, A -6-9 - 6 7 8 Load voltage, V Turn on time, ms LED forward current, ma Turn off time, ms.... LED forward current, ma. Output capacitance vs. applied voltage Measured portion: between terminals and 6; Frequency: MHz; Ambient temperature: C 77 F. Max. operating frequency vs. load voltage and load current LED current: ma Ambient temperature: C 77 F Output capacitance, pf 6 Max. operating frequency, cps duty=% Applied voltage, V Load voltage, V Load current, A ASCTBE 7-T