High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

Similar documents
Brochure. Automotive Immunity Test System. (ISO7637) Global Office of Lisun Electronics Inc.

Brochure. Colorimeter. (CD Series ) Global Office of Lisun Electronics Inc.

LM Test Report

LM Test Report

LM Test Report

LM Test Report

LM Test Report

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

Photometric Test Report

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

Photometric Test Report

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LM Test. for LED. Cabinet

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

Eternal Shine Technology Co.,Ltd. EST

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

REVOLUTION LIGHTING TECHNOLOGIES INC

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Photometric Test Report

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

LED Lighting Flux and Color Measurement System (LFC)

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

IESNA LM-79: Measurement and Test Report for Green Creative Ltd. Room , New Victory House, Wing Lok Street, Central, HONG KONG

NVLAP LAB CODE:

Application Note (A16)

NVLAP LAB CODE:

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

Photometric Test Report

illumia Plus Temperature Controlled Light Measurement Systems

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

Cat# LED High Bay

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

CTI nm mg. Test Report. Report No.: EED35H l Page 1 of 15. EiKO Global, LLC W 84th St, Shawnee, KS

QPL ID # PLG2YNJ831VZ

LED14.5WPAR30S/FL/827-DIM

LED Tester BTS256-LED

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

RoHS QPL ID # PLC6V1PABNUJS

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

NVLAP LAB CODE:

NVLAP LAB CODE:

NVLAP LAB CODE:

Report No.: HZ c

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

IES LM Report. Technical Requirements Table, V4.0, DLC Premium DesignLights Consortium Product Application Category

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

Cat# 71440A LED Classic Large Wall-Pack

Dimming: PWM/TIME/0-5V/0-10V. RoHS


Cat# 71146A 150W Trunion Mount

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

71352A QPL ID # PLT2P2L2UNWR. RoHS

Transcription:

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure Global Office of Lisun Electronics Inc. http://www.lisungroup.com Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong Tel: 00852-68852050 Fax: 00852-30785638 Email: SalesHK@Lisungroup.com Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: SalesSH@Lisungroup.com Lisun Sales Rep Office (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: Sales@Lisungroup.com Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: Engineering@Lisungroup.com Lead in CFL & LED Test Instruments Rev. 20161124

CONTENT TABLE Name Model Remark Pag e High Precision CCD Spectroradiometer LMS-9000B Option is LMS-9000A -----2 Optical Fiber CFO-1.5M Option is CFO-1.5MY for LMS-9000A two integrating -----3 spheres Optical Path Converter LS512A It works with LMS-9000B -----7 Digital CC and CV DC Power Supply DC3005 Option is DC3010 or DC6005 -----3 Digital Power Meter LS2012 Option is LS2010/LS2008R -----4 AC Power Source LSP-500VAR Option is LSP-500VAS -----5 New Design Integrating Sphere IS-1.5MA Option is IS-1.5MA55C -----6 Small Integrating Sphere IS-0.3M For single LEDs test -----6 Standard Lamp Source SLS-50W 24V/50W to calibrate big integrating sphere -----7 Auxiliary Lamp Test Set RLS-50W To correct lumen due to the self absorption issue -----7 Standard Lamp Source SLS-10W 6V/10W to calibrate for small integrating sphere -----7 19 Inch Cabinet CASE-19IN -----7 Appendix 1: LM-80 LED LED Optical Maintenance Test Report -----8 Appendix 2: LM-79 LED Colorimetric, Photometric and Electrical Test Report -----9 Note the following: If you need to test the single LED or LED Chip, you should choose the items which marked by Blue -Page 1 -

1 High Precision CCD Spectroradiometer LMS-9000 is adopting the world advanced Holographic grating with flat-field correction, precision optical system and the electronic shutter control technology. The test speed can be in milliseconds and the test accuracy is in the laboratory level. It has the lowest value of stray light, LMS-9000B has high repeatability and stability testing. It is fully meet CIE127-1997, IES LM-79-08 and IES LM-80-08. Specifications: Spectral Range Wavelength: 380nm~800nm Spectral Wavelength Accuracy: ±0.5nm(LMS-9000A), ±0.3nm(LMS-9000B), Wavelength Reproducibility: ±0.5nm(LMS-9000A), ±0.1nm(LMS-9000B) Accuracy of Chromaticity Coordinate ( x, y): ±0.003 (LMS-9000A) and ±0.002 (LMS-9000B) Correlated Color Temperature CCT: 1,500K~25,000K(LMS-9000A), 1500K~100,000K(LMS-9000B), CCT Accuracy: ±0.5%(LMS-9000A), ±0.3%(LMS-9000B) Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3) Photometric linear: ±0.5% (LMS-9000A) and ±0.3% (LMS-9000B) Stray light: <0.015%(600nm) and <0.03%(435nm) Time of integration: 0.1ms-20s It can measure the temperature inside and outside of integrating sphere LMS-9000 used the Band pass-filter Wheel Correcting Technique, Spectrometer & Broadband-radiometer & photometer Combined Technique, and modified NIST stray light correction technology, the LMS-9000 spectroradiometer can realize ultra low stray light and super photometry linearity in overall dynamic range. -Page 2 -

2 Optical Fiber CFO-1.5M is 1.5m length optical fiber used to connect the spectroradiometer and integrating sphere. CFO-1.5MY is Y type optical fiber which work with LMS-9000A can connect with two integrating spheres at the same time. 3 Digital CC and CV DC Power Supply The DC Series Power Supplies are with high stability and high accuracy. The voltage and current can be adjustable and simple operation. They are suitable to supply DC Power for the standard lamps. Specifications: Accuracy of Voltage and Current: +/-(0.02 Reading+0.01% Range+1 Digit) Stability of Output Voltage/Current: +/-0.01% Reading/3min Digital control for Constant Current output or Constant Voltage output Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled. Model DC3005 DC3010 DC6005 DC6010 DC12005 U Range 0.0005-30.000V 0.0005-30.000V 0.0005-60.000V 0.0005-60.000V 0.0001-120.00V I Range 0.0005-5.0000A 0.0005-10.000A 0.0005-5.0000A 0.0005-10.000A 0.0005-5.0000A -Page 3 -

4 Digital Power Meter Measure Voltage, Current, Power and Power Factor. Voltage range:10~600v; Current range: 0.005~20A Accuracy: ±(0.4%reading + 0.1%range + 1digit) Communicate with PC by RS-232. It can communicate with LISUN spectroradiometer Model Measure Remark LS2008R AC Parameters: U, I, P, PF LS2010 AC Parameters: U, I, P, PF and harmonic Special Software can show harmonic in Win7 or Win8 LS2012 AC+DC Parameters: : U, I, P, PF DC: 1~600v, DC Current Range: 0.005~20A, out of limit alarming LS2050 AC+DC+Harmonic with high test accuracy Special Software can show harmonic in Win8 or Win8 The LS2010 has a separately software can do harmonic analysis as below -Page 4 -

5 AC Power Source AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU Protection for over hot, thundering voltage and current Total voltage distortion: 0.6%; Voltage stability: 0.1%/30min Load adjust rate: 0.1%; Frequency stability: 0.05%/30min Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz Input Power: 220V and 50/60Hz Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled. Lisun Output Remark Model Power LSP-500VAS 0~150V: 4.2A, 150~300V: 2.1A 500W (LSP-500VAR is pure sine wave AC power source LSP-500VAR with low harmonic and high accuracy) LSP-1KVAS 0~150V: 8.4A, 150~300V: 4.2A 1000W (LSP-1KVAR is pure sine wave AC power source with LSP-1KVAR low harmonic and high accuracy) 6 New Design Integrating Sphere Due to the LED luminaries such as LED street luminaries developed, to do 4π geometry testing, it is hard to be hold in the traditional integrating sphere design. To solve this problem, Lisun design a new kind of sphere. The Lisun new Integrating sphere has the following advantages: The hold base can bear max 20kg, it can test all kinds of luminaires and light source such as E27/E40, all tubes such as T5/T8/T12 and all kinds of luminaries The hold base can be installed in the ceiling or down, it can be adjusted the height The test hold base has four power cables connect to the outside Power Supply and max is 5KW -Page 5 -

Specification: Diameter: 0.3m, 0.5m, 1.0m, 1.5m, 1.75m, 2.0m, 2.5m and 3.0m The painting of integrating spheres is according to CIE Pub.No.84(1989) BaSO4 coating: ρ(λ) 0.96(450nm~800nm) and ρ(λ) 0.92(380nm~450nm) Fine diffuse reflection: Reflectanceρ 0.8 and accuracy of ρ(λ)<1.5% Order Number: Lisun Model 1.0m 1.5m 1.75m 2m Square side opening IS-1.0MA IS-1.5MA IS-1.75MA IS-2.0MA IS-1.0MA33C IS-1.5MA55C IS-1.75MA66 C IS-2.0MA77C Remark: The 55C in IS-1.5MA55C means the side opening is diameter=50cm cycle size 7 Auxiliary Lamp (RLS-50W) Due to the luminaires material has self-absorption, the test flux will be a bit difference than the original flux when test the luminaires in the integrating sphere, according to CIE request, it is necessary use an Auxiliary lamp to do flux self-absorption revise. -Page 6 -

8 Standard Lamp Source OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source Integrating Sphere Size 0.3m/0.5m 1m/1.5m/1.75m 2m/2.5m/3m Standard Lamp Source SLS-10W SLS-50W SLS-100W 9 Optical Path Converter (LS512A) The LS512A work with LMS-9000B can be switch between the two spheres conveniently, but no need to take out the detector cable and optical fiber between the big sphere and small sphere 10 Standard Instrument Cabinet 19Inch (CASE-19IN) Combine all of the test instruments in a 19 inch standard Cabinet, makes the whole systems looks nice and is simple to use -Page 7 -

Appendix 1: LM-80 LED Optical Maintenance Test Report The testing results can be exported Excel files to do detail analyse: The testing results can be exported Excel files to do detail analyse:

Appendix 2: LM-79 LED Colorimetric, Photometric and Electrical Test Report

-Page 1 -