MHz FUNCTION GENERATOR INSTRUCTION MANUAL

Similar documents
EC Declaration of Conformity

TG MHz Function Generator Service Manual

TG MHz DDS Function Generator INSTRUCTION MANUAL

TG550 AIM & THURLBY THANDAR INSTRUMENTS. 5MHz function generator with sweep

W DC ELECTRONIC LOAD INSTRUCTION MANUAL

CIRCUIT-TEST ELECTRONICS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

8120 FUNCTION GENERATOR Operation Manual

8110 FUNCTION GENERATOR. Safety Instruction. Safety Symbols

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

User s Manual Current Probe. IM E 2nd Edition IM E

DM-45 Digital Multimeter

BENNING. CM7 Electrical Tester. Service Information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Model 4007DDS. 7 MHz Sweep Function Generator

USER'S MANUAL DMR-6700

5MHz FUNCTION GENERATOR

5MHz FUNCTION GENERATOR

INSTRUCTION MANUAL MODEL 4010A. 2 MHz FUNCTION GENERATOR MANUAL DE INSTRUCCIONES MODELO 4010A. 2MHz GENERADOR DE FUNCIONES

Digital Clamp Meter Model: &

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

MODEL W Power Amplifier

Arbitrary/Function Waveform Generators 4075B Series

COM-POWER OPERATION MANUAL ACS W

Model : OPERATING MANUAL Table of Contents (1)

Appendix A: Specifications

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

GF 467F FUNCTION GENERATOR. PROTECTED RS232 + (USB OR LAN)* LabVIEW 0,01 Hz to 5 MHz CMos. Specifications. Other specifications

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

KMD-S04 Multímetro de bolsillo

LH240 LH1040 LH2040 LH2015

INSTRUCTION MANUAL FUNCTION GENERATOR FG-274 B

CBA 400M MHZ to 400 MHZ

LH630 LH635 LH1035. Operating Instructions Mode d emploi Bedienungsanleitung Istruzioni per il funzionamento Instrucciones de Funcionamiento

Appendix A: Specifications

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

Model MHz Arbitrary Waveform / Function Generator

AMM-1022 Digital Multimeter USER`S MANUAL

User s Manual Current Probe IM E. 8th Edition

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

Agilent 1146A AC/DC Oscilloscope Current Probe

Power supply CP-D 24/4.2 Primary switch mode power supply

TT-SI 9001 / TT-SI MHz Active Differential Probes

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

V1.3. TBLC08 50mH AC-LISN TBLC08

Keysight N2790A Differential Voltage Probe. User Guide

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

SAFETY PRECAUTIONS: Before use, read the following safety precautions

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

MODEL 3810/2 Line Impedance Stabilization Network

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

THURLBY THANDAR INSTRUMENTS. TGA1240 SERIES 40MHz ARBITRARY WAVEFORM GENERATORS INSTRUCTION MANUAL

79/26 Series III Multimeter

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

DDS Function Generator

9 Specifications. Specifications NOMINAL CHARACTERISTICS

HAWK5000 Operators Manual

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Model and

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Tablet Oscilloscope Safety Information

Chapter 6 Specifications

TT-SI MHz Active Differential Probe

AC/DC CLAMP METER USER S MANUAL

Digital Function Generator

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

FUNCTION GENERATOR OPERATION MANUAL

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

T L Audio CRIMSON SERIES. User Manual EQ-3011 EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

User s Guide. 400A AC/DC Clamp Meter. Model MA220

1. BP4620 SPECIFICATIONS

DIGIT & POINTER MULTIMETER

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

TT-SI MHz DIFFERENTIAL PROBE

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

1157A 2.5 GHz Active Probe

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

1156A 1.5 GHz Active Probe

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

TA MHz oscilloscope probe TA MHz oscilloscope probe

Model Hz to 10MHz Precision Phasemeter. Operating Manual

1147A 50 MHz Current Probe

TT-SI MHz Active Differential Probe

N2790A Differential Voltage Probe

INSTRUCTION MANUAL. Model 4012A. 5 MHz SWEEP FUNCTION GENERATOR. with DIGITAL DISPLAY

Transcription:

72-6859 20MHz FUNCTION GENERATOR INSTRUCTION MANUAL

Table of Contents Introduction 2 Specification 2 EMC 5 Safety 4 Installation 5 Operation 7 Maintenance 8 www.tenma.com 1

Introduction This instrument is a 20MHz function generator with waveforms of sine, square, triangle, ramp, pulse and DC from a variable amplitude 50Ω output. A TTL output is also provided. The frequency range is 0.2Hz to 20MHz selected by an eight decade range multiplier and calibrated vernier. The sweep input can be used to give a >20:1 frequency change within a selected range. The generator output level is 20Vpk-pk maximum from a 50Ω source. The level is set via switched attenuators plus vernier with a total range of 66dB. DC offset is vernier adjustable over a ±10V range with 0V defined by a centre detent. A switchable symmetry control with a 6:1 range permits ramp and pulse waveforms to be produced. Specification FREQUENCY Frequency Range: Vernier Range: Vernier Accuracy: 0.2Hz to 20MHz in 8 overlapping decade ranges with fine adjustment by a vernier. >10:1 on each range. Typically ± 5% of full scale. SWEEP MODE (EXTERNAL) Sweep Range: Typically >20:1. Input Impedance: 82 kω Input Sensitivity: Typically 0 to 2V for 10:1 sweep. Maximum Allowable Input Voltage: ± 10V Maximum Slew Rate of sweep voltage: 0.1V/us OPERATING MODES (Specifications apply for the top decade of each frequency range and output 10V peak-to-peak into 50Ω termination). Sine Distortion: Amplitude Flatness: Triangle Linearity: Squarewave Rise and Fall Times: DC Range: Symmetry Symmetry Range: Typically 2% on 200, 2k and 20k ranges. ± 0.2dB to 200kHz; ± 2dB to 20MHz. Typically 99% on khz ranges. <22ns ±10V from 50Ω Typically variable from 1:6 to 6:1 up to 500kHz. 2 www.tenma.com

OUTPUTS 50Ω TTL GENERAL Three switch-selectable ranges with 26dB vernier control within each attenuator range. 0dB Range: 1V to 20V peak-to peak from 50Ω (0.5V to 10V into 50Ω). 20dB Range: 100mV to 2V peak-to-peak (50mV to 1V into 50Ω) 40dB Range: 10mV to 0.2V peak-to-peak (5mV to 0.1V into 50Ω) DC Offset Control Range: ±10V from 50Ω. DC offset plus signal peak limited to ±10V (± 5V into 50Ω). DC offset plus waveform attenuated proportionally in 20dB and 40dB position. Capable of driving 4 standard TTL loads. Power: Operating Range: Storage Range: 230V or 115V nominal 50/60Hz, adjustable internally; operating range ±14% of nominal; 30VA max. Installation Category II. + 5ºC to +40ºC, 20% to 80% RH. 40ºC to +70ºC Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2. Electrical Safety: Complies with IEC 1010-1 EMC: Size: Weight: Complies with EN50081-1 and EN50082-1 220(W) x 82(H) x 230(D) mm, (10.3 x 3.4 x 9.2 ) excluding feet. 1.5 kg (3.3lb). www.tenma.com 3

Safety This instrument is Safety Class I according to IEC classification and has been designed to meet the requirements of IEC 1010-1 (Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use). It is an Installation Category II instrument intended for operation from a normal single phase supply. This instrument has been tested in accordance with IEC 1010-1 and has been supplied in a safe condition. This instruction manual contains some information and warnings which have to be followed by the user to ensure safe operation and to retain the instrument in a safe condition. This instrument has been designed for indoor use in a Pollution Degree 2 environment in the temperature range 5 C to 40 C, 20% - 80% RH (non-condensing). It may occasionally be subjected to temperatures between +5 C and 10 C without degradation of its safety. Do not operate while condensation is present. Use of this instrument in a manner not specified by these instructions may impair the safety protection provided. Do not operate the instrument outside its rated supply voltages or environmental range. WARNING! THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous. Intentional interruption is prohibited. The protective action must not be negated by the use of an extension cord without a protective conductor. When the instrument is connected to its supply, terminals may be live and opening the covers or removal of parts (except those to which access can be gained by hand) is likely to expose live parts. The apparatus shall be disconnected from all voltage sources before it is opened for any adjustment, replacement, maintenance or repair. Any adjustment, maintenance and repair of the opened instrument under voltage shall be avoided as far as possible and, if inevitable, shall be carried out only by a skilled person who is aware of the hazard involved. If the instrument is clearly defective, has been subject to mechanical damage, excessive moisture or chemical corrosion the safety protection may be impaired and the apparatus should be withdrawn from use and returned for checking and repair. Make sure that only fuses with the required rated current and of the specified type are used for replacement. The use of makeshift fuses and the short-circuiting of fuse holders is prohibited. Do not wet the instrument when cleaning it. The following symbols are used on the instrument and in this manual:- Caution -refer to the accompanying documentation, incorrect operation may damage the instrument. terminal connected to chassis ground. mains supply OFF. l mains supply ON. alternating current. 4 www.tenma.com

Emissions Immunity Cautions This function generator has been designed to meet the requirements of the European EMC Directive 89/336/EEC. Compliance was demonstrated by meeting the test limits of the following standards: EN50081-1 (1992) Generic emission standard for residential commercial and light industry. Test methods and limits used were: a) EN55022 Conducted, Class B b) EN55022 Radiated, Class B EN50082-1 (1992) Generic immunity standard for residential, commercial and light industry. Test methods and limits used were: a) EN60801-2 (1993) Electrostatic Discharge, 8 kv air discharge. b) IEC801-3 (1984) RF Field, 3 V/m. c) IEC801-4 (1988) Fast Transient, 1 kv peak (AC line), 0.5kV peak (signal lines). To ensure continued compliance with the EMC directive the following precautions should be observed: a) connect the generator to other equipment using only high quality, double-screened cables. b) after opening the case for any reason ensure that all signal and ground connections are remade correctly before replacing the covers. Always ensure all case screws are correctly refitted and tightened. c) In the event of part replacement becoming necessary, only use components of an identical type, see the Service Manual. EMC www.tenma.com 5

Installation Mains Operating Voltage The operating voltage of the instrument is shown on the rear panel. Should it be necessary to change the operating voltage from 230V to 115V or vice-versa, proceed as follows: 1. Disconnect the instrument from all voltage sources. 2. Remove the 4 screws which hold the upper and lower case halves together and lift off the case upper. 3. Change the transformer connections following the diagrams below. 230V Operation - Primaries in series 115V Operation - Primaries in parallel Mains Lead 4. Reassemble in the reverse order. 5. To comply with safety standard requirements the operating voltage marked on the rear panel must be changed to clearly show the new voltage setting. WARNING! THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous. Intentional interruption is prohibited. 6 www.tenma.com

Operation Power The ON/OFF switch is on the rear panel of the instrument. Frequency Selection Symmetry Frequency range is selected by an eight position multiplier switch with fine adjustment by calibrated vernier. A slide switch selects the symmetry control which varies the duty cycle 1:6 to 6:1 to produce sawtooth and variable pulse-width waveforms. Note: The symmetry of the Aux Output does not vary when Sine or Triangle are selected because the Aux Output is generated by a zero crossing comparator. Function Selection The output waveform shape is selected by a four position switch to give sine, square, triangle and DC. A DC level only is useful as it permits input threshold testing of a circuit without having to connect up an external supply. Main Output DC Offset Aux Output The amplitude of the 50Ω MAIN output is controlled by the 3-position ATTENUATOR switches and AMPLITUDE control. Maximum output is 20 volts peak-to-peak from 50Ω and 10 volts peakto-peak when terminated with a 50Ω load. The AMPLITUDE control has greater than 26dB range and used in conjunction with the ATTENTUATORS a range of 0dB to 66dB can be achieved. This provides a range of 20V peakto-peak down to 10mV peak-to-peak, or 10V peak-to-peak down to 5mV peak-to-peak into 50Ω. Greater attenuation can be achieved by using standard 50Ω BNC attenuators. To maintain waveform integrity only 50Ω cable should be used and the receiving end should be terminated with a 50Ω load. The 50Ω MAIN output will withstand a short circuit for a period of 2 minutes at maximum output and greater periods at lower output levels. Do not apply external voltages to this output. The DC OFFSET control has a range of ±10 volts from 50Ω in all output modes; the control has a centre detent for 0 volts. DC offset plus signal peak is limited to ± 10V (± 5V into 50Ω). DC offset plus waveform is attenuated proportionally in the 20dB and 40dB positions. The AUX output provides a fixed TTL pulse output at the same frequency and phase as the 50Ω MAIN output and is capable of driving 4 standard TTL loads. Sweep Input The generator frequency can be swept, DC programmed or modulated by a suitable control voltage applied to the SWEEP IN socket. The instrument sums the SWEEP IN voltage with the internal control voltage derived from the FREQUENCY vernier to determine the operating frequency. A positive voltage increases the frequency; for frequency control with positive-going DC inputs the vernier should therefore be set to the lower frequency limit of the range to be swept. For example, a 0V to +2V signal will sweep the generator 1 decade up from range minimum, set by the vernier, to range maximum. www.tenma.com 7

Similarly, a negative voltage decreases the frequency and for negative-going DC inputs the vernier should be set to the upper frequency limit of the range to be swept. For example, a 0V to 2V signal will sweep the generator 1 decade down from range maximum, set by the vernier, to range minimum. To use a sweep signal which is symmetrical about ground, the vernier should be set to give a frequency at approximately the centre of the band to be swept. Do not apply external voltages exceeding ±10V. Cleaning Mains Fuse Maintenance For service repair and calibration please contact your local Tenma distributor or go to www.tenma.com If the instrument requires cleaning use a cloth that is only lightly dampened with water or a mild detergent. WARNING! TO AVOID ELECTRIC SHOCK, OR DAMAGE TO THE INSTRUMENT, NEVER ALLOW WATER TO GET INSIDE THE CASE. TO AVOID DAMAGE TO THE CASE NEVER CLEAN WITH SOLVENTS. The transformer primary is protected by an integral thermal fuse which is not user replaceable. Should a fault develop which causes the thermal fuse to blow, the generator must be returned to the manufacturer or agent for service. 8 www.tenma.com

TEST EQUIPMENT 405 Pioneer Blvd. Springboro, Ohio 45066 Book Part No. 48591-0730 Issue 1