Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Similar documents
Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight Technologies DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options

Keysight U1882B Measurement Application for Infiniium Oscilloscopes. Data Sheet

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

U1881A and U1882A Power Measurement Application for InfiniiVision and Infiniium Oscilloscopes

Keysight DSOXT3FRA/DSOX4FRA/DSOX6FRA Frequency Response Analyzer (FRA) Option

Agilent U1881A and U1882A Power Measurement Application for Agilent InfiniiVision and Infiniium Oscilloscopes

Keysight Technologies N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes. Data Sheet

Keysight N8836A PAM-4 Measurement Application For Infiniium S-Series, 90000A, V-Series, X-Series, Q-Series, and Z-Series Oscilloscopes

Keysight Technologies Accurate Evaluation of MEMS Piezoelectric Sensors and Actuators Using the E4990A Impedance Analyzer.

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Keysight Technologies Migrating Balanced Measurements from the

Keysight Technologies 7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes. Application Note

Keysight Technologies

Keysight N8803C CAN, LIN, FlexRay, and CAN-FD Protocol Triggering and Decode Software. Data Sheet

Keysight Technologies How to Select the Right Current Probe. Application Note

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

Keysight Technologies Making Current-Voltage Measurement Using SMU

Keysight Technologies

Keysight Technologies, Inc. Overcome PCB Loss and Deliver a Clean Eye to Your DUT Using Multi-tap De-emphasis

Keysight Technologies CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000 and S-Series Oscilloscopes.

Keysight Technologies InfiniiScan Event Identification Software

Keysight Technologies Accurate NBTI Characterization Using Timing-on-the-fly Sampling Mode. Application Note

Keysight Technologies How to Easily Create an Arbitrary Waveform Without Programming. Application Note

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies Network Analyzer Measurements: Filter and Amplifier Examples. Application Note

Keysight Technologies Making Field Effect Transistor Characterization Using SMU

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Keysight Technologies Measuring Low Current Consumption with a Digital Multimeter

Keysight Technologies How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer.

Keysight Technologies Simultaneous Measurements with a Digital Multimeter

Keysight Technologies N2750A/51A/52A InfiniiMode Differential Active Probes. Data Sheet

Keysight HMMC-1002 DC 50 GHz Variable Attenuator

Keysight Measuring High Impedance Sources Using the U8903B Audio Analyzer. Application Note

Keysight Technologies MATLAB Data Analysis Software Packages

Keysight Technologies Alliance for Wireless Power (A4WP) Measurements Using an Oscilloscope (Part 3)

Keysight Technologies N9310A RF Signal Generator

Keysight Technologies N4983A Multiplexer and Demultiplexer. Data Sheet

Introduction. Part 1. Introduction...2

Keysight Technologies Precise Low Resistance Measurements Using the B2961A and 34420A

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

Keysight Technologies Educator s Oscilloscope Training Kit for InfiniiVision X-Series Oscilloscopes. Data Sheet

Keysight Technologies Improving the Test Efficiency of MEMS Capacitive Sensors Using the E4980A Precision LCR Meter.

Keysight Technologies RS-232/UART Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes. Data Sheet

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Keysight Technologies Accurate Capacitance Characterization at the Wafer Level

Introduction. Part 1. Introduction...2

Keysight Technologies HMMC GHz High-Gain Amplifier

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

Keysight Technologies Improving Test Efficiency of MEMS Electrostatic Actuators Using the E4980A Precision LCR Meter.

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

Keysight Technologies USB Preamplifiers

Keysight Technologies Make Better AC RMS Measurements with Your Digital Multimeter. Application Note

Keysight Quickly Generate Power Transients for Testing Automotive Electronics. Application Note

Keysight E5063A ENA Vector Network Analyzer

Keysight E5063A ENA Series Network Analyzer

Keysight Technologies Making Simpler DC Power Measurements with a Digital Multimeter

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

Keysight Technologies N4985A System Amplifiers

7 Hints That Every Engineer Should Know When Making Power Measurements with Oscilloscopes.

Keysight Technologies NFC Device Turn-on and Debug

Keysight Technologies Using a Network and Impedance Analyzer to Evaluate MHz RFID Tags and Readers/Writers

Keysight M940xA PXIe Optical Extenders for Instrumentation. Data Sheet

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight Technologies Using an External Trigger to Generate Pulses with the B2960A

Keysight M9485A PXIe Multiport Vector Network Analyzer

Keysight Technologies How to Read Your Power Supply s Data Sheet. Application Note

Keysight N9310A RF Signal Generator

Keysight Technologies Precise Current Profile Measurements of Bluetooth Low Energy Devices using the CX3300. Application Brief

Keysight Technologies Achieving Accurate E-band Power Measurements with E8486A Waveguide Power Sensors. Application Note

Keysight Technologies Migrating from the 4268A/4288A Capacitance Meter to the E4981A Capacitance Meter. Technical Overview

Keysight Technologies Measuring Group Delay of Frequency Converters with Embedded Local Oscillators. Application Note

Keysight Technologies Direct Power MOSFET Capacitance Measurement at 3000 V

Keysight Redefines 50 GHz Portability. Get a $30k Credit When You Move Up to FieldFox

Keysight N2806A Calibration Pulse Generator The world s fastest differential pulse generator. Data Sheet

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight Technologies MEMS On-wafer Evaluation in Mass Production

Keysight Technologies Secondary Radar Transponder Testing Using the 8990B Peak Power Analyzer. Application Note

Keysight Technologies 85072A 10-GHz Split Cylinder Resonator. Technical Overview

Keysight Technologies Automated Receiver Sensitivity Measurements Using U8903B. Application Note

Keysight Technologies U9391C/F/G Comb Generators. U9391C (10 MHz to 26.5 GHz) U9391F (10 MHz to 50 GHz) U9391G (10 MHz to 67 GHz) Technical Overview

Keysight Technologies High Frequency Probing Solutions for Time and Frequency Domain Applications. Application Note

Keysight Technologies Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Keysight Technologies Overcoming LTE-A RF Test Challenges. Application Note

N2820A/21A High-Sensitivity, High Dynamic Range Current Probes

Keysight Technologies Power of Impedance Analyzer

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight 8762F Coaxial Switch 75 ohm

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Keysight Technologies FFT and Pulsed RF Measurements with 3000T X-Series Oscilloscopes. Application Note

Keysight Technologies, Inc. UWB Antenna Measurements with the 20 GHz E5071C ENA Network Analyzer. Application Note

Keysight Technologies

Keysight Technologies Active Differential Probes U1818A 100 khz to 7 GHz U1818B 100 khz to 12 GHz. Technical Overview

Keysight Technologies Minimum Required Sample Rate for a 1-GHz Bandwidth Oscilloscope

Keysight Technologies Waveguide Power Sensors. Data Sheet

N2750A/51A/52A InfiniiMode Differential Active Probes

Keysight Technologies Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Transcription:

Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options For InfiniiVision 3000, 4000 and 6000 X-Series Oscilloscopes Data Sheet

02 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet Achieve Cost-Effective Analysis of Your Switch Mode and Linear Power Supply Characteristics Today s power supply designers are facing an increasing number of constraints in the development of high-efficiency, low-cost power supplies. Cost-effective solutions used to be the designer s key target. Today, rising energy costs bring power supply efficiency to the forefront. Additionally, other constraints such as design compactness, migration to digital control, tighter voltage tolerances, and regulations for power quality and EMI force the need for quick and thorough power supply testing. Increasing design constraints translate into more time dedicated to power device measurement and analysis for today s power supply designers. The Keysight Technologies, Inc. DSOX3PWR, DSOX4PWR, and DSOX6PWR are power measurement and analysis options that are integrated into InfiniiVision 3000, 4000, and 6000 X-Series scopes. The embedded application provides a quick and easy way of analyzing the reliability, efficiency and performance of your switching and linear power supplies. These power measurement options also come with the user license for the U1881A-003 PC-based power measurement and analysis software that provides even more powerful insight into your power supply measurements. In spite of the increasing analysis capability offered by many oscilloscopes over recent years, it is not uncommon to see designers perform measurements and analysis manually. These measurements typically take a considerable amount of time to capture, analyze and report. Type of analysis Measurement DSOX3PWR DSOX3PWR DSOX4PWR DSOX6PWR on 3000A on 3000T Input measurements Power quality: Real power Apparent power Reactive power Power factor Crest factor (V&I) Phase angle Current harmonics 1 Inrush current Switching device measurements Switching loss 2 Rds(on) Vce(sat) Slew rate (V&I) Modulation analysis 3 Output measurements Output ripple Turn-on time Turn-off time Efficiency 4 Transient response settling time Frequency response measurements Power Supply Rejection Ratio (PSRR) 5 Control loop response (Magnitude and phase plot) 5 Other Auto probe deskew 6 Auto setup 7 Notes: 1. Based on IEC 61000-3-2 standard for class A, B, C, and D products. Tabular or bar chart display user-selectable display formats with automatic pass/fail color-coded indication along with total harmonic distortion (THD). 2. Power and energy losses based on V x I always, or Rds(on) or Vce(sat) during conduction phase only. 3. Duty cycle, pulse width, frequency, period, etc., versus time trend plot. 4. AC-to-DC, DC-to-AC, AC-to-AC, or DC-to-DC user-selectable efficiency measurements. 5. Utilizes scope s built-in waveform generator. WaveGen option not required. 6. Requires U1880A probe deskew fixture. 7. Automatic setups with connections diagrams for all repetitive input measurements. Step-by-step instructions for all single-shot measurements including turn-on/off time, inrush current, and transient response.

03 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet Power Device Analysis The switching loss in a power supply determines its efficiency. You can easily characterize for instantaneous power loss and conduction power loss at the switching device over a designated switching cycle. To determine the efficiency of the power supply it is very important to measure the power loss during dynamic load changes. By measuring the switching loss and conduction loss, you can characterize the instantaneous power dissipation in your switching power supply. Locating peak switching loss helps you analyze the reliability of the power supply. The di/dt and dv/ dt represent the rate at which the current and voltage change at switching. This helps in analysis of reliable operation of the switching mode power supply. Figure 1. By measuring the switching loss and conduction loss, you can characterize the instantaneous power dissipation in a switching power supply. Line Power Analysis Power supply designers need to characterize the line power for power quality, harmonics and conducted emissions under different operating conditions of the power supply. Some of the implicit measurements are real power, apparent power, reactive power, power and crest factor and graphical display of harmonics with respect to standards such as IEC 61000-3-2 (Class A, B, C, D). By using a current probe and power measurement option, conducted power line harmonics can be measured. Also, line power analysis includes the inrush current measurement that shows the peak inrush current value when the power supply is first turned on. Figure 2. Perform the pre-compliance line harmonic testing of your power supply to the IEC 61000 3-2 standards. This analysis presents up to 40 harmonics. Figure 3. The Inrush current analysis measures the peak inrush current of the power supply when the power supply is first turned on.

04 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet Power Quality Analysis The Power Quality analysis shows the quality of the AC input line. Some AC current may flow back into and back out of the load without delivering energy. This current, called reactive or harmonic current, gives rise to an apparent power which is larger than the actual power consumed. Power quality is gauged by these measurements: power factor, apparent power, true power, reactive power, crest factor, and phase angle of the current and voltage of the AC line. Modulation Analysis Modulation analysis allows designers to quickly see the on-time and off-time information of the PWM signal, which is difficult to visualize because the information bandwidth is much lower than the pulse switching frequency. Plotting the embedded variation of on time or off time in the PWM signal over a long period of time can reveal the control loop response of the feedback loop system. This measurement performs data trending on the switching variation of the acquired waveform in the following format. Figure 4. The power measurements option provides a results table with the following power quality measurements: Power Factor, Real Power, Apparent Power, Reactive Power, Crest Factor and Phase Angle. Frequency vs time Period vs time Duty cycle vs time Positive pulse width vs time Negative pulse width vs time Figure 5. Plotting the embedded variation of on time or off time in the PWM signal over a long period of time can reveal the control loop response of the feedback loop system. Output Analysis Output analysis includes characterization of the ripple component (either power line or switching) in output DC voltage. Ripple is the residual AC component that is superimposed on the DC output of a power supply. Line frequency as well as switching frequency can contribute to ripple. This measurement analyzes the output voltage ripple and presents the peak-to-peak value as well as the frequency response of the captured signal. Figure 6. The output analysis includes characterizing the ripple component (either power line or switching) in output DC voltage.

05 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet Turn On/Off Time Analysis This analysis measures the time taken to get to the steady output voltage of the power supply after the input voltage is applied (turn on time) and for the output voltage of the power supply to turn off after the input voltage is removed (turn off time). Figure 7. The turn-on analysis measures the time taken to get to the steady output voltage of the power supply after the input voltage is applied. Transient Response Analysis Power supplies are subject to transient conditions, such as turnon and turn-off transients, as well as sudden changes in output load and line input voltage. These conditions lead to one of the key specifications of the power supplies; load transient response. This analysis measures the load transient response of the DC output, namely the time taken for the DC output to stabilize during a load change. Figure 8. The transient analysis measures the load transient response of the DC output, namely the time taken for the DC output to stabilize during a load change. Efficiency Analysis Efficiency analysis tests the overall efficiency of the power supply by measuring the output power over the input power. This analysis requires a 4- channel oscilloscope because input voltage, input current, output voltage, and output current are measured. Figure 9. Efficiency analysis tests the overall efficiency of the power supply

06 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet PSRR (Power Supply Rejection Ratio) Characterizing PSRR over frequency commonly involves the use of an expensive analyzer equipped with a DC bias port such as Keysight s ENA network analyzers. Modulated power supply Input LDO Output Load The DSOX3PWR/DSOX4PWR/DSOX6PWR option utilizes the InfiniiVision built-in WaveGen BNC output that generates a swept frequency, simplifying the test solution in one box and significantly reducing the cost. The PSRR is defined as the ratio of the input ripple compared to the output ripple over a wide frequency range and is expressed in db. The basic equation for PSRR is WaveGen Figure 10. The PSRR is defined as the ratio of the output ripple compared to the input ripple over a wide frequency range. Ripple input (V in ) PSRR = 20 log Ripple output (V out ) Figure 11 shows an example of a PSRR measurement on a linear power supply using an InfiniiVision X-Series oscilloscope with the power option. In this measurement example, the scope measured a maximum rejection of 96 db. To learn more about PSRR measurements, refer to the application note listed at the end of this document. Figure 11. The PSRR is a measure of how well a circuit rejects ripple coming from the power supply input at various frequencies.

07 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet Control Loop Response (Bode) A power supply is actually an amplifier with a negative feedback control loop as shown in Figure 12. This means that although you may think of a power supply as a DC amplifier, it actually amplifies AC to react to changes in output conditions, such as load changes. Performing a Control Loop Response test requires that you inject an error signal over a band of frequencies into the feedback path of the control loop. The resistive-divider network of R1 and R2 is the feedback path in this diagram. To inject an error signal, a small resistor must be inserted into the feedback loop. The 5-Ω injection resistor shown in this schematic is insignificant in comparison to the series impedance of R1 and R2. So you might consider designing in this low-value injection resistor (Rinj) permanently for test purposes. An injection transformer, such as Picotest s J2101A, is also required so that the AC disturbance signal is isolated and doesn t induce any DC bias. Figure 12. Power supply closed loop feedback network and oscilloscope connections for a Control Loop Response test. The measurement system, in this case an InfiniiVision X-Series oscilloscope with its built-in WaveGen function/awg generator, measures AC voltage levels at the top of the feedback network (Vin) as well as at the regulated DC output (Vout) of the power supply. The scope then computes gain as 20Log(Vout/Vin) at each frequency within the swept band. Also measured at the same time is the phase difference between Vin and Vout. Figure 13 shows the results of a Control Loop Response gain and phase plot using an InfiniiVision X-Series oscilloscope. This test was performed using a swept frequency from 100 Hz up to 20 MHz. At the completion of the swept measurement, the scope automatically measured the phase margin at the 0 db cross-over frequency, and also measured the gain margin at the 0 degree cross-over frequency. To learn more about Control Loop Response measurements, refer to the application note listed at the end of this document. Figure 13. Control Loop Response gain measurement using an InfiniiVision X-Series oscilloscope.

08 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet Probe Deskewing With the U1880A Deskew Fixture Timing delay errors between voltage and current probes may have a significant impact on power measurements as each specific voltage and current probes have different propagation delays. To make accurate power measurements and calculations, it is extremely important to null out the time delay between the voltage and current probes using a procedure known as deskewing. This step is critically important since a small offset in the timing of the voltage and current traces can cause a large error in the instantaneous power reading. By performing probe deskew before making power measurements, you can ensure the most accurate measurement. The Keysight U1880A deskew fixture allows you to quickly deskew your voltage and current probes, enabling accurate and precise measurements of power supply efficiency. The U1880A deskew fixture generates a built-in voltage and current test signal and allows you to probe the same electrical point with a variety of voltage and current probes. With only a single click in one of the power measurements setup, deskewing is automatically performed and the deskew factors are saved in the power measurement application, so the next time when you launch the power measurement application, you can use the saved deskew values or perform the deskewing again. Figure 14. To make accurate power measurements and calculations, it is extremely important to null out the time delay between your voltage and current probes. Figure 15. The Keysight U1880A deskew fixture allows you to quickly deskew your voltage and current probes, enabling accurate and precise measurements of power supply efficiency.

09 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet Ordering Information Product number Description DSOX3PWR DSOX4PWR DSOX6PWR U1880A Power Measurement software integrated into the 3000 X-Series (also includes the U1881A PC-based Power Measurement and Analysis 1 software license) Power Measurement software integrated into the 4000 X-Series (also includes the U1881A PC-based Power Measurement and Analysis software license) Power Measurement software integrated into the 6000 X-Series (also includes the U1881A PC-based Power Measurement and Analysis software license) Deskew fixture for voltage and current probe deskewing 1. To learn more about the U1881A PC-based power measurement application for InfiniiVision oscilloscopes, refer to the U1881A data sheet with Keysight literature number 5989-7835EN. Recommended Probes and Accessories For more information about Keysight s scope probes and accessories, visit www.keysight.com/find/probes. Recommended probes AC/DC current probes (one or more of these Keysight current probes) 1147B 50 MHz, 15 A AC/DC current probe with AutoProbe interface N2893B 100 MHz, 15 A AC/DC current probe with AutoProbe interface N2780B 2 MHz, 500 A AC/DC current probe (requires N2779A power supply) N2781B 2 MHz, 150 A AC/DC current probe (requires N2779A power supply) N2782B 2 MHz, 30 A AC/DC current probe (requires N2779A power supply) N2783B 2 MHz, 30 A AC/DC current probe (requires N2779A power supply) Differential probes N2790A 100 MHz, ± 1.4 kv differential probe N2791A 25 MHz, ± 700 V differential probe N2804A 300 MHz, ± 300 V differential probe N2805A 200 MHz, ± 100 V differential probe N2891A 70 MHz, ± 7 kv differential probe Passive probe (for measuring output noise and PSRR) N2870A 1:1 35 MHz passive probe N2804A 2.5 mm probe tip-to-pcb adapter Related Literature Publication title Switch Mode Power Supply Measurements - Application Note Power Supply Control Loop Response (Bode Plot) Measurements - Application Note Power Supply Rejection Ratio (PSRR) Measurements - Application Note Publication number 5991-1117EN 5992-0593EN 5992-0594EN

10 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet Keysight Oscilloscopes Multiple form factors from 20 MHz to > 90 GHz Industry leading specs Powerful applications

11 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. The business that became Keysight was a founding member of the AXIe consortium. ATCA, AdvancedTCA, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. The business that became Keysight was a founding member of the LXI consortium. www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system.

12 Keysight DSOX3PWR/DSOX4PWR/DSOX6PWR Power Measurement Options - Data Sheet Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument s lifecycle. Our comprehensive service offerings onestop calibration, repair, asset management, technology refresh, consulting, training and more helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System This information is subject to change without notice. Keysight Technologies, 2017 Published in USA, December 2, 2017 5990-8869EN www.keysight.com