Product data sheet Palas Fidas 200 E

Similar documents
REAL-TIME DUST MONITOR FOR INDOOR AIR QUA- LITY MEASUREMENTS AND WORKPLACE EXPOSURE ASSESSMENTS FIDAS

ENGINE EXHAUST PARTICLE SIZER SPECTROMETER MODEL 3090

DATACAR ADVANCED MULTILANE TRAFFIC MONITORING SYSTEM

Product Specification HD-S208 V

FW100 Dust Measurement Device

RISONIC modular Ultrasonic transit time flow measurement in penstocks and open channels

Dräger X-zone 5500 with Advanced 3D Communications

Z+F IMAGER 5006i. IMAGER 5006EX the world s only explosion proof 3D laser scanner.

ENGINE EXHAUST PARTICLE SIZER SPECTROMETER MODEL 3090

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

Combi sensor C B1. A: Wind wheel. west, east, south C: Dawn sensor D: Rain sensor. Ref.-No. with DCF77 receiver WS 10 KSDCF (No KNX device)

Submersible pressure sensor For water and wastewater Model LW-1

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

BioInstrumentation Laboratory

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

Mod. 2 p. 1. Prof. Dr. Christoph Kleinn Institut für Waldinventur und Waldwachstum Arbeitsbereich Fernerkundung und Waldinventur

mass flowmeter for compressed air

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

This is how PI Does Measuring - Part I

Bulk Flow Meter LB 442 CONTACTLESS MEASUREMENT

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

INTRODUCTION Laser Particle Sensor Module PM2007

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

Millikelvin Thermometers MKT 10 MKT 50

COMPACT Diode Laser System (Water-Cooled)

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

Sapphire FP. Fiber Pigtailed Lasers from Deep Blue to Orange FEATURES

POWER CUBE SA/80 series

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

Hygro-ThermoTransmitter-compact xxx

THICKNESS CHECK NON-CONTACT THICKNESS MEASUREMENT OF FLAT PRODUCTS

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

UP-D74XRD. DICOM Digital Imager.

Foreign Particulate Matter testing using the Morphologi G3

Transient high sensitive soot measurement. AVL Micro Soot Sensor. Manfred Linke

Laser 3 Plus - Process Oxygen

TruHeat HF Series 1000 / 3000 / When it comes to process heat, don t compromise.

Submersible pressure sensor For oils and fuels Model LF-1

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

NanoMet Nanoparticle Diameter Example Report

CAMAG TLC VISUALIZER 2

Optical Sensor Systems from Carl Zeiss CORONA PLUS. Tuned by Carl Zeiss. The next generation in the compact class

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Laser Particle Sensor Module PM2105

In-Line Moisture Measurement

Wind Transmitter First Class Advanced Classified according to IEC ( )

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Preliminary Specification

Study of DBD electrostatic precipitator under different high voltage waveforms

SodiumStar 20/2 High Power cw Tunable Guide Star Laser

QAQC LAB 589 Rappahannnock Drive White Stone Va TEL (866)

Residual Oil Aerosol Measurements on Refrigerators and Liquefiers

USTER TESTER 5-S800. The yarn inspection system. Technical Data

Online data sheet GM35 IN-SITU GAS ANALYZERS

Think of LASER as a tool

SOLARONIX. Solixon A-1525-V

COFFEE LABORATORY WHITE STONE VA Tel (804)

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

Wind Transmitter First Class

ARUBA AS-100 WIRELESS SENSOR

High speed OBD sensor response and time resolution measurements. Antti Rostedt, Ossi Vuorinen, Kauko Janka, Jaakko Yli-Ojanperä and Jorma Keskinen

CONSTRUCTION PRODUCT TECHNICAL CARD

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

Fine Dust Sensors Frequently Asked Questions FAQ

UV-RADIATION PYROMETER SPM U16W

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

RPG-HATPRO-G5 series High-precision microwave radiometers for continuous atmospheric profi ling

Features. Applications. Optional Features

DIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Laser Particle Sensor Module PM3015

EverBlu. Wireless fixed data collection system

WATERFLUX 3070 Technical Datasheet

Achieving 100,000 : 1 contrast measurement

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

Optimized for perfection.

B850 Boiler House Energy Monitor

Ultraclean Flow Measurement!

Coriolis Mass Flow Meters. Advanced flow measurement made easy.

RISONIC modular Ultrasonic transit time flow measurement in penstocks and open channels

MaxxFlow HTC. Product Information. Flow Measurement for Dry Bulk Solids

Laser Particle Sensor Module PM2105

Microwave Radiometry Laboratory Experiment

Atlantic. series. Industrial High Power Picosecond DPSS Lasers

Wireless Transceivers for Fuel Level Sensors RUd-DF-232 RUd-DF-485. Instruction Manual Version # 2.1 VTAS IM

RISONIC modular Ultrasonic transit time flow measurement in penstocks and open channels

LST100 Ultrasonic level transmitter for upstream oil and gas

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Leading in Desktop SEM Imaging and Analysis

DEUTROFLUX. Accessories for Magnetic Particle Inspection. Field Strength Gauge DEUTROMETER II. In Actual Size

Operating Instructions. MaxxFlow HTC Measurement of Bulk Solids for High Flow Rates

OPUS20 Multiple Functions with Internal Sensors

SWT 200 Wide-Belt Sanding Machines

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Using Microwave Sensors to Measure Moisture Levels in Mozzarella Cheese

MaxxFlow HTC Flow measurement for dry bulk solids

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

Transcription:

Product data sheet Palas Fidas 200 E Applications Regulatory environmental monitoring in measuring networks Ambient air measurement campaigns Long-term studies Emission source classification Distribution studies (e.g. fires, volcanoes) Indoor air quality studies

Benefits High flexibility for installation due to separation of sensor unit and control unit Continuous and simultaneous real-time measurement of multiple PM values Additional information on particle number concentration and particle size distribution Adjustable time resolution starting at 1 minute Light source: LED with high stability and long lifetime Long service life Low maintenance External check of calibration on site possible Intuitive and easy to operate Reliable function, very high data availability (> 99 %) 2 pumps in parallel operation for additional operational safety due to redundancy Permanent monitoring of status, among others online monitoring of calibration Remote monitoring, maintenance and control easily possible Cloud zone via Palas server for worldwide data retrieval No radioactive material No consumables

Description The Fidas 200 E is a fine dust monitoring and ambient air measurement system for ambient air monitoring of fine dust for regulatory purposes. This version is like the Fidas 200 - designed for indoor installation at temperature-controlled sites and is typically incorporated in measurement cabinets or stations. The Fidas 200 E enables the continuous and simultaneous measurement of PM1, PM2.5, PM4, PM10, TSP (PMtot), as well as the particle number concentration and the particle size distribution in a size range of 180 nm to 18 µm (further non-certified size ranges possible upon request). The Fidas 200 E is based on the Fidas 200, which including the variant Fidas 200 S is currently the only optical ambient air measuring system for online and simultaneous PM2.5- and PM10-measurements at single particles (counting measuring method), which is type-approved according to the Standards VDI 4202-1, VDI 4203-3, EN 12341 (PM10), EN 14907 (PM2,5) and the EN Equivalence Guide GDE and certified according to the Standards EN 15267-1 and -2. The Fidas 200 E differs from the Fidas 200 in that the complete sensor unit is removed from the control unit and is placed in an external housing. The connection between the sensor unit and the control unit is carried out via respective connecting lines/-tubes (standard length 3 m, different lengths upon request). The external sensor unit itself is connected downstream to the sampling system (outlet of IADS) as usual. By separating the sensor unit from the control unit and the related possible separation between the installation site of the control unit and installation site of the sampling, the degree of freedom for the installation of the measuring system in a measuring station is increased significantly, especially in case of already given infrastructures (e.g. existing roof penetrations from former installations). The sensor unit can also easily be re-installed in the control unit, so that at any time the measuring system Fidas 200 E can be transferred back to the measuring system Fidas 200. The official declaration of suitability and the incorporation of the Fidas 200 E into the existing certification of the Fidas 200 respectively Fidas 200 S according to Standard series EN 15267 has been recommended to the certification body by the responsible working group FG "Prüfberichte" and is expected in Spring 2016 (Status: mid December 2015). The Fidas 200 E uses the recognized measurement technology of optical light scattering of single particles and is equipped with an LED light source with high intensity (dpmin = 180 nm), highly stable output and long lifetime. The calibration of the system can be checked and adjusted, if necessary, easily and quickly also under field conditions on site at any time with the help of a monodisperse test powder. The Fidas 200 E operates with a volume flow of approx. 0.3 m3/h and is equipped with a Sigma 2 sampling head as per Standard VDI 2119-4, which enables representative measurements even under strong wind conditions. The sampling system includes a drying system (intelligent aerosol drying system IADS) that prevents measurement inaccuracies caused by condensation effects resulting from high humidity. In addition, a weather station provides reliable results for ambient air temperature, atmospheric pressure, and relative humidity, by request additionally also for wind velocity, wind direction and precipitation. It is also equipped with a filter holder for the insertion of a plane filter (47 or 50 mm in diameter). This enables a subsequent chemical analysis of the composition of the aerosol, for example. The Fidas 200 E offers various possibilities for communication and allows both complete remote control and remote maintenance of the systems and also online data access via

www.palas.de/user. The evaluation software PDAnalyze Fidas allows additionally for versatile data evaluations (e.g. extensive statistics and averaging calculations) and offers data export possibilities. Design and function The actual aerosol sensor is an optical aerosol spectrometer that determines the particle size using Lorenz Mie scattered light analysis of single particles. The single particles move through an optically differentiated measurement volume that is homogeneously illuminated with white light. Each particle generates a scattered light impulse that is detected at an angle of 85 to 95 degrees. The particle number is measured based on the number of scattered light impulses. The level of the scattered light impulse is a measure of the particle size diameter The lower detection limit for immission measurement was able to be reduced to 180 nm through improved optics, higher light density using a new white LED as the light source, and improved signal analysis (logarithmic analog digital converter). This enables greatly improved detection, especially of smaller particles, which are mainly found at high concentrations near roadsides (see Fig. 1). Fig. 1: Higher sensitivity with the Fidas fine dust measurement system for the 0.18 18 µm particle size range The better the classification accuracy and the resolution capacity, the more accurate the definition of the particle size distribution. resolution. The patented T-stop provides a precisely defined optical measurement volume and enables particle measurement without border-zone errors, resulting in a precise size measurement. The new digitized electronic signal analysis system enables the rapid identification and correction of coincidence, as necessary. Fig. 2: Comparison of the algorithms for conversion of the particle size distribution by PM values In order to convert the measured values into a mass or mass fraction, the high-resolution particle size distribution in each value is multiplied by a correlation factor that reflects the different sources (e.g. combustion aerosols, tire wear, pollen) of the environmental aerosol (see Fig. 2). A mass fraction is obtained by additionally applying the separation curve (see DIN EN 481) to the determined particle size distribution. Exact matches with gravimetric results cannot be guaranteed in every case due to the different principle of measurement (equivalent method), but as a matter of principle a very good correlation with the standard reference method (see Fig. 3) could be demonstrated among others during the type approval testing and can be reviewed in the type approval test report of the Fidas 200 S respectively Fidas 200 under www.qal1.de. Using a white light source enables a precise and unambiguous calibration curve to be obtained, resulting in an extremely high size

Multiple separation curves can be used simultaneously for the same size distribution, which enables the simultaneous output of PM10, PM2.5, PM1 (and others). Fig. 3: PM10 reference equivalence function of the Fidas 200 S in comparison with a reference small-filter device during the course of suitability testing from the "Report on supplementary testing of the Fidas 200 S respectively Fidas 200 measuring system manufactured by PALAS GmbH for the components suspended particulate matter PM10 and PM2.5, TÜV report no.: 936/21227195/A".

Specifications Interfaces Measurement range (size) Size channels Measuring principle Measurement range (number CN) Time resolution USB, Ethernet, RS232/485, Wi-Fi 0.18-100 µm (3 measuring ranges) 64 (32/decade) Optical light-scattering 0-20000 particles/cm³ 1 s - 24 h, 15 min in type approved operation Volume flow 4.8 l/min 0.3 m³ /h Data acquisition Power consumption Digital, 20 MHz processor, 256 raw data channels Approx. 200 W User interface Touchscreen, 800 480 Pixel, 7 Power supply Housing 115-230 V, 50-60 Hz Table housing, optionally with mounting brackets for rackmounting (control unit) Dimensions 450 320 180,5 mm (H B T), 19 Weight Operating system Data logger storage Software Aerosol conditioning Measurement range (mass) Sampling head Ambient conditions 9.3 kg (control unit only) Windows embedded 4 GB PDAnalyze Fidas Thermal with IADS 0-10000 µg/m³ Sigma-2-10 +50 C