Exclusive Technology Feature

Similar documents
ECE514 Power Electronics Converter Topologies. Part 2 [100 pts] Design of an RDC snubber for flyback converter

AP8010. AiT Semiconductor Inc. APPLICATION

AN TEA1836XT GreenChip SMPS control IC. Document information

In addition to the power circuit a commercial power supply will require:

Getting the Most From Your Portable DC/DC Converter: How To Maximize Output Current For Buck And Boost Circuits

High-Efficiency Forward Transformer Reset Scheme Utilizes Integrated DC-DC Switcher IC Function

MP6004 Primary-Side Regulated Flyback/Buck 80V DCDC Converter

Wide Input Voltage Boost Controller

SRM TM A Synchronous Rectifier Module. Figure 1 Figure 2

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Simulation Comparison of Resonant Reset Forward Converter with Auxiliary Winding Reset Forward Converter

Conventional Single-Switch Forward Converter Design

A7221A DC-DC CONVERTER/BUCK (STEP-DOWN) 600KHz, 16V, 2A SYNCHRONOUS STEP-DOWN CONVERTER

U6115S&D. Features. Description. Package Information. Applications. Pin Configuration

Presentation Content Review of Active Clamp and Reset Technique in Single-Ended Forward Converters Design Material/Tools Design procedure and concern

Keywords: No-opto flyback, synchronous flyback converter, peak current mode controller

Modeling The Effects of Leakage Inductance On Flyback Converters (Part 2): The Average Model

EE155/255 F16 Midterm

LM5034 High Voltage Dual Interleaved Current Mode Controller with Active Clamp

Dimming Universal High Brightness LED Driver

Doing More with Buck Regulator ICs

Application of E-Fuse in a DC/DC converter. No Smoke, No Fire

AN Analog Power USA Applications Department

Incorporating Active-Clamp Technology to Maximize Efficiency in Flyback and Forward Designs

MAXREFDES121# Isolated 24V to 3.3V 33W Power Supply

DESCRIPTION FEATURES APPLICATIONS TYPICAL APPLICATION. 500KHz, 18V, 2A Synchronous Step-Down Converter

MP6902 Fast Turn-off Intelligent Controller

Constant-Frequency Soft-Switching Converters. Soft-switching converters with constant switching frequency

Monolithic Power Switcher for Off-line SMPS. Features

Universal and Dimmable LED Driver

Development of SMPS for Medium Voltage Electrical Drives

CHAPTER 3. SINGLE-STAGE PFC TOPOLOGY GENERALIZATION AND VARIATIONS

Testing and Stabilizing Feedback Loops in Today s Power Supplies

Analyzing The Effect Of Voltage Drops On The DC Transfer Function Of The Buck Converter

Differential-Mode Emissions

I. Erickson Problem 6.4 A DCM Two Transistor Flyback Converter

Chapter 6: Converter circuits

4.5V to 32V Input High Current LED Driver IC For Buck or Buck-Boost Topology CN5816. Features: SHDN COMP OVP CSP CSN

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

Vishay Siliconix AN724 Designing A High-Frequency, Self-Resonant Reset Forward DC/DC For Telecom Using Si9118/9 PWM/PSM Controller.

MODERN switching power converters require many features

UNISONIC TECHNOLOGIES CO., LTD UC1108 Preliminary CMOS IC

New lossless clamp for single ended converters

Designers Series XII. Switching Power Magazine. Copyright 2005

Single Switch Forward Converter

Under the Hood of Flyback SMPS Designs

LD /01/2013. Boost Controller for LED Backlight. General Description. Features. Applications. Typical Application REV: 00

CHAPTER IV DESIGN AND ANALYSIS OF VARIOUS PWM TECHNIQUES FOR BUCK BOOST CONVERTER

Design Consideration with AP3041

Chapter 3 HARD SWITCHED PUSH-PULL TOPOLOGY

ACE726C. 500KHz, 18V, 2A Synchronous Step-Down Converter. Description. Features. Application

Electronics. RC Filter, DC Supply, and 555

Improvements of LLC Resonant Converter

Comparing the UC3842, UCC3802, and UCC3809 Primary Side PWM Controllers. Table 1. Feature comparison of the three controllers.

INTEGRATED CIRCUITS. AN120 An overview of switched-mode power supplies Dec

Single Stage Offline LED Driver

PS7516. Description. Features. Applications. Pin Assignments. Functional Pin Description

Preliminary. Synchronous Buck PWM DC-DC Controller FP6329/A. Features. Description. Applications. Ordering Information.

Flyback Converter for High Voltage Capacitor Charging

CONTENTS. Chapter 1. Introduction to Power Conversion 1. Basso_FM.qxd 11/20/07 8:39 PM Page v. Foreword xiii Preface xv Nomenclature

1.5MHz, 800mA Synchronous Step-Down Regulator

AND8161/D. Implementing a DC/DC Single Ended Forward Converter with the NCP1216A APPLICATION NOTE

N386X APPLICATION INFORMATION

LM5067 reverse current surge restart issue

AN-6203 Applying SG6203 to Control a Synchronous Rectifier of a Flyback Power Supply

Features. Applications. 1.2MHz Boost Converter with OVP in Thin SOT-23-6

High Performance ZVS Buck Regulator Removes Barriers To Increased Power Throughput In Wide Input Range Point-Of-Load Applications

Application Note AN-1018

INTEGRATED CIRCUITS. AN1221 Switched-mode drives for DC motors. Author: Lester J. Hadley, Jr.

Dr.Arkan A.Hussein Power Electronics Fourth Class. Commutation of Thyristor-Based Circuits Part-I

A simple and compact high-voltage switch mode power supply for streak cameras

VCC. UVLO internal bias & Vref. Vref OK. PWM Comparator. + + Ramp from Oscillator GND

DUAL STEPPER MOTOR DRIVER

A7115. AiT Semiconductor Inc. APPLICATION ORDERING INFORMATION TYPICAL APPLICATION

NCP1216AFORWGEVB. Implementing a DC/DC Single ended Forward Converter with the NCP1216A Evaluation Board User's Manual EVAL BOARD USER S MANUAL

AN-9719 Applying Fairchild Power Switch (FPS ) FSL1x7 to Low- Power Supplies

EUP V/12V Synchronous Buck PWM Controller DESCRIPTION FEATURES APPLICATIONS. Typical Application Circuit. 1

EECS 473 Advanced Embedded Systems

Transformers for Offline Flyback Converters

DESCRIPTION FEATURES PROTECTION FEATURES APPLICATIONS. RS2320 High Accurate Non-Isolated Buck LED Driver

SP6003 Synchronous Rectifier Driver

1.5MHz, 2A Synchronous Step-Down Regulator

LM5021 AC-DC Current Mode PWM Controller

HT2801S. Description. Features. Application. Typical Application Circuitry. High Accuracy CV/ CC Primary Sensing Regulation Controller IC

D8020. Universal High Integration Led Driver Description. Features. Typical Applications

MAXREFDES116# ISOLATED 24V TO 5V 40W POWER SUPPLY

Application Note AN- 1117

RT V DC-DC Boost Converter. Features. General Description. Applications. Ordering Information. Marking Information

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

FSFR-XS Series Fairchild Power Switch (FPS ) for Half-Bridge Resonant Converters

IN A CONTINUING effort to decrease power consumption

Lecture 19 - Single-phase square-wave inverter

Title. Description. Date 16 th August, Revision 1.1 RD W Telecoms DC/DC PSU Input : 37Vdc to 60Vdc Output : 32V/10A

A7108. AiT Semiconductor Inc. APPLICATION ORDERING INFORMATION TYPICAL APPLICATION

DC/DC Converters for High Conversion Ratio Applications

Assuming continuous conduction, the circuit has two topologies switch closed, and switch open. These are shown in Figures 2a and 2b. L i C.

A More-Efficient Half-Bridge LLC Resonant Converter: Four Methods For Controlling The MOSFET

RAD HARD 36V, 2A, 2.0MHz STEP-DOWN SWITCHING REGULATOR CONTROLLER

PARALLELING of converter power stages is a wellknown

Dual 1.5MHz, 1A Synchronous Step-Down Regulator

Transcription:

ISSUE: February 2011 Primary-Side Current Monitoring Won t Stop Overcurrents In DCM-Operated Flybacks by John Bottrill, Senior Applications Engineer, and Lisa Dinwoodie, Applications Engineer, Power Management, Texas Instruments, Dallas, Texas Many designers assume that the use of the primary-side pulse-by-pulse current monitoring and control in a flyback power converter is sufficient to limit the secondary-side current to slightly more than the maximum load requirement. A review of this technique demonstrates that this is not the case and that the current out of a flyback converter can easily result in higher than expected currents, if using this method. In turn, this can result in damage to the components in the power converter. To explain why this is the case and why improved fault protection is needed, we ll begin by reviewing operation of the flyback converter and discuss the factors that leave the flyback converter vulnerable to an overcurrent event when operating in discontinuous mode. We ll then note the lesser impact of this problem on flybacks operating in the continuous mode. The focus here is on the discontinuous-mode (DCM) topology because it is the more popular topology, but also because this overcurrent problem is potentially more severe in DCM operation. Flyback Operation Fig. 1 shows a simplified circuit for the flyback converter that can be used to explain its operation. Fig. 1. Typical flyback topology power components. To understand this discussion, it is important to recognize that the magnetic component of the flyback converter is not a transformer, but a coupled inductor. Energy is stored when the primary side switch, Q1, is on and this energy is released to the secondary side when Q1 is turned off. The current through Q1 at the point in time when Q1 turns off is equal to the initial current through the diode D1, once the turns ratio of the flyback inductor is taken into consideration. The switching frequency (Fsw) and the maximum power out of the converter define the energy that the flyback inductor must process during each cycle of time (T) where T = 1 Fsw. In the design of a discontinuous-mode flyback converter, the maximum on time (Ton) of the primary switch must be less than the conduction time of the rectifying diode. If the reverse is true, the ringing of the primary 2010 How2Power. All rights reserved. Page 1 of 6

side during light load and low-input voltage conditions could drive the drain of Q1 below ground. As this is not the subject of this article, we will not dwell on it here. Examining the circuit requirements under minimum input voltage and maximum load leads to the design of the converter. We will assume that the duty cycle (Ton/T) of Q1 has a 45 percent maximum on time and a 50 percent maximum conduction time for the diode (D1). The energy transferred during each cycle is the total input dc current (Idc) over a cycle T, multiplied by the input voltage. In a lossless system, this would be the same as the energy out of the converter. Let s assume for this discussion that we have a lossless system. We start with the following equation for charge: Q = Idc in T where Q is the charge in Coulombs. The energy in and out of the converter on a single cycle is defined as: Energy = Q Vin = Vout Iout dc T When the main switch turns on, the current in the primary winding increases at a linear rate of di/dt. This is a function of the input voltage and the primary-side magnetizing inductance. When looked at on a scope, this forms a triangle. The area under that triangle must sum to Q. di / dt = Vin Lmag The integral of this triangle of current over the time Ton equals Q. Q 2 = 0.5 ( Vin / Lmag) Ton, which is the standard equation for the area of a triangle where the peak of the triangle is Ipeak = ( Vin / Lmag) Ton = ( di / dt) Ton. The energy being transferred to the secondary on each pulse is a function of the peak current and the magnetizing inductance 2 E =. 5 Ipeak Lmag Since we know the input voltage (V IN ), the frequency Fsw (which gives us T), the duty cycle (Ton) and the power which gives us Idc and allowing for losses (in this case it is zero as we have defined it as a lossless system), it is relatively easy to calculate the maximum Lmag that will work for the primary side. We know that when Q1 turns off, the energy stored in the inductor will cause the voltage on the anode of D1 and the drain of Q1 to increase. The voltage on D1 will increase until D1 is forward biased and the current out of N2 will equal Ipeak ( N1 N 2) = Ipeak out since the same number of ampere-turns are needed as they represent the stored flux in the magnetic material. Now using the same equations, it is easy to identify the secondary inductance (Lmag-s). The typical circuit is shown in Fig. 1 and the associated waveforms are presented in Fig. 2. The waveforms shown in Fig. 2 have been normalized for inputs and outputs, and the effects of leakage inductances are being ignored. Losses in the FET Q1 and the diode D1 are ignored. The top waveform is the voltage on the drain of Q1. The middle waveform is a composite of the current in the primary winding (black) and the secondary winding (red). The bottom trace is the voltage on the anode of D1. 2011 How2Power. All rights reserved. Page 2 of 6

Fig. 2. Idealized voltage and current waveforms for a discontinuous-mode flyback converter. As can be seen in the discontinuous mode, the current on the output falls to zero in each cycle. The peak current on the primary is sensed across the resistor, RIsense. This voltage level is compared to a control level and triggers the turn off of the FET. The control level is a function of the output voltage and the voltage feedback loop. The overcurrent threshold limit is a function of internal set points in the controller. This overcurrent limit by design of the converter is user-defined to trigger if the input current peak gets to a level that is between 20 and 50 percent above the maximum current for the worst-case load condition. This allows the converter to handle transients without damaging the devices. This threshold tolerance depends on the IC, but the lowest trip point must be sufficiently above maximum worst-case operation to allow for transients. For demonstration purposes, we will assume that there has been a sudden and permanent low impedance applied across the output so that the output voltage drops immediately to some arbitrary value, say 20 percent of nominal (see Fig. 3). Additionally, we will assume that the control loop responds instantly. 2011 How2Power. All rights reserved. Page 3 of 6

Fig. 3. Output voltage drops to 20 percent of initial value. The result is that the di/dt of the output side of the coupled inductor decreases because the voltage across the secondary winding has decreased. The voltage on the output has dropped (immediately after Q1 turns off on the first pulse of Fig. 3) so the control loop is now demanding more current. The main switch of the converter on subsequent pulses stays on until the primary current reaches the over current limit and shuts off the switch. The current out of the inductor is significantly higher now than during normal operation, but the di/dt on the secondary is much lower also because the output voltage has dropped. Because the di/dt is so much lower, there is residual energy in the inductor when the converter main switch turns back on. And because there is residual current in the inductor when the main switch turns back on at the beginning of the next cycle, the primary-side current starts with an offset and reaches the overcurrent trip peak much faster. This results in reduced on time of the main switch and increased conduction time for the diode at higher currents. This does not mean there is more energy being transferred, only more current. Fig. 3 shows the impact of the change in both the input and output voltage waveforms and current under these conditions. As shown in Fig. 3, when the output voltage drops, the voltage on the anode of D1 drops as does the reflected voltage on the drain of Q1. Because the voltage across the winding drops, this changes the slope of the current out of that winding. This slope change results in the current through the secondary not going to zero before the initiation of the next power pulse. When the next power pulse starts the current in the coupled inductor, primary side starts at a level above zero (point A of Fig. 3). 2011 How2Power. All rights reserved. Page 4 of 6

When taken to the extreme limit with the output voltage dropping to zero, the down slope becomes flat and the on time of the main switch approaches zero. This means the current out of the diode will reflect the primary side overcurrent limit reflected to the secondary and at a near-continuous level. If the peak current limit is 50 percent higher than the nominal maximum output current maximum trip point and the output voltage approaches zero volts, it is possible to get a rough estimate of the output current as a percentage of the Imax. In operation with a 50 percent conduction time for the diode, the peak current is a factor of four times the peak dc output current. When the overcurrent trip point is reached, the peak will be 50 percent higher, resulting in six times the nominal maximum dc output current. By the same token, the primary-side input current has decreased because of the shorter on time of Q1. If the circuit has leading-edge blanking, which prevents the controller from seeing the initial current spike, this current level can be much, much higher. If the converter has not been designed for this continuous current level, it likely will be destroyed by running for an extended time with this output current. A similar outcome is likely for the continuous-mode flyback converter, although the output current will not increase by a factor of six. More than likely it will hit a factor of two or three because the initial output slope is shallow and does not go to zero normally. Again, under these conditions, leading-edge blanking will impact the current level in a negative manner. To prevent this type of failure from destroying the converter (and for other reasons), the power to the control IC is usually off an auxiliary winding on the flyback converter. If the output voltage drops for more than a few hundred milliseconds, the converter is shut down and must attempt to go through a soft start, usually with a significant delay before restart. Recent IC developments recognize this potential catastrophic failure for the discontinuous topology. These devices prevent the main switch from turning on again as long as there is current in the output winding of the transformer. Test data from an evaluation model (EVM) with this type of controller is shown in Fig. 4, illustrating the output current of the unit. Fig. 4. Short circuit test data. 2011 How2Power. All rights reserved. Page 5 of 6

The pulses of current are a result of the intermittent operation where safety features inside the IC allow it to operate in the fault condition for a short period, then shut everything down for a predetermined time. The image (Fig. 4 again) shows a converter with a normal 2.1-A output operating into a shorted output. The output current goes to 4.7 A average for the duration of the operating pulse. The output short circuit current can be defined as: I sec_ sc = (( Np / Ns) Ipeak) 2 Conclusion Operating a flyback converter without the added protection like that provided by the latest-generation of controllers leaves the converter vulnerable to major damage in the event of a short circuit on the output. That is, unless additional circuits are added around the controller IC to prevent such damage. In the future, power converters using these controller ICs will be even better equipped to handle short-circuit conditions as the latest-generation controllers continue being developed to prevent this problem from occurring. About the Author John Bottrill is a senior applications engineer at Texas Instruments in Manchester, NH. John supports customers and evaluates new ICs before release. In doing so, he has produced more than 20 technical papers and has two patents to his credit. He received his B. Sc. in Electrical Engineering from Queen s University at Kingston, Ontario, Canada. You can reach John at ti_johnbottrill@list.ti.com. Lisa Dinwoodie is an applications engineer at Texas Instruments where she supports customers, evaluates new ICs before release, and designs evaluation modules for customer use. Lisa has more than 16 years in the power supply design industry. She received her B.Sc. in Electrical Engineering from Northeastern University in Boston, Massachusetts. You can reach Lisa at ti_lisadinwoodie@list.ti.com. For further reading on flyback converter design, see the How2Power Design Guide, search the Topology category and select Flyback as the subcategory. 2011 How2Power. All rights reserved. Page 6 of 6