Insulation Test System

Similar documents
Insulation Test System

Combination Wave Test System

Telecom Test System. Lightning Tests

Low Frequency Measuring System

EMC PARTNER. DO-160 & MIL-STD-461G TEST SYSTEM Indirect Lightning Testing

Avionics Test System. Lightning Tests

MILITARY & AEROSPACE TESTING

Electricity Meter Test System

Low Frequency Measuring System

ESD Test System. Immunity Tests

ESD MODULAR HANDHELD TESTER Electrostatic Discharge Testing

Technical Specification

MIL Standard 461 G. final release December 11 th, EMC PARTNER - Largest range of impulse test equipment up to 100kV and 100kA

Technical Specification

Advanced Test Equipment Rentals ATEC (2832)

Surge Generator for MIL-STD 1275

Schlöder GmbH - EMC Test and Measurement Systems Model #

Immunity Testing for the CE Mark

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

Advanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.

Introduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.

Conducted Immunity Testing

7P Series - Surge Protection Device (SPD) Features 7P P P

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters

Intra-system EMI hardening for increased machine reliability. Ray Brett.

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

XY-Capacitor Surge Test (IEC )

Technical Requirements for Resistibility of Telecommunications Equipment to. Overvoltage and Overcurrent

2620 Modular Measurement and Control System

CAR - TEST - SYSTEM 14

INTERNATIONAL STANDARD

MEDIUM & HIGH VOLTAGE

Voltage Transient Emission Test

CS114 + CS115 + CS116

Regulatory authority use EMC PARTNER's HAR1000 to enforce Harmonic and Flicker CE requirements in Germany

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

PMT/UMT(275) Power Gap Description and Use Application Note

Transient Protection

SIOV metal oxide varistors

Avionics Indirect Lightning

Understanding Design, Installation, and Testing Methods That Promote Substation IED Resiliency for High-Altitude Electromagnetic Pulse Events

Overcurrent Protection / 7SJ45

Lightning Surge Simulator LSS-F03 series

satech SynchroStar GPS 200 Series

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1402 HIGH VOLTAGE ENGINEERING UNIT I

LS200 TEST DATA IEC61000 SERIES

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

KOLLMORGEN. Motion Technologies Group. EMC Installation and Application Guidelines for BDS4/5 Goldline Series MB4000H Issue 3

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

50W Constant Current (700mA) Dimming LED Driver

The Role of the Grounding System in Electronics Lightning Protection

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

OCS 500N6F SERIES SIMULATOR FOR FAST AND SLOW DAMPED OSCILLATORY WAVES AND RINGWAVE

DC/DC power module 3.3V / 4.5A / 14.8W

Electromagnetic and Radio Frequency Interference (EMI/RFI) Considerations For Nuclear Power Plant Upgrades

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Safety through Competence. Short Form Catalogue. Measuring Testing Controlling World Class Hardware and Software

High Votage Module AC/DC/Impulse Test System

GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

DC/DC power module 1.8 V / 5A / 9W

ST-250MAK-05E. Switching Power Supply SPECIFICATION

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER

Holiday Detector mod. 184/45KV

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

2520 Pulsed Laser Diode Test System

TC-600PD2. Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION. Revision: 1.0

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

CVVOZE Power Laboratories (CVVOZEPowerLab)

704-15K36P RTCA DO-160G COMPLIANT PRODUCT HIGH POWER AIRCRAFT/ VEHICLE DC BUS VOLTAGE SUPPRESSOR DESCRIPTION 704 PACKAGE FEATURES APPLICATIONS

1. General Instructions 2 2. Safety 2 3. Lamp Starting Test Instrument LSTI 5 3

Fast transient burst simulator

USER MANUAL XLB-2500 Short Arc Xenon Lamp Ballast

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

METRAClip87 and 88 Clamp Multimeters

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

SPECIFICATION. SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

Type CP-S, CP-C & CP-A Switch mode

Low Profile. 3 Year Warranty

OLU131P701N1A PSOV131701A(N) PSOV131701B(N) PSOV131701D(N) (for SAMSUNG) PSOV131701E(N) (for SAMSUNG) SOLUM CO., LTD

TRAX Transformer and Substation Test System

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

FlexRay Communications System. Physical Layer Common mode Choke EMC Evaluation Specification. Version 2.1

Tektronix: Products > AWG 2040 Arbitrary Waveform Generator

EMC Test report for LED Panel Light Models , , , , ,

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

Harmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests

DC/DC power module 5V / 3A / 15W

Output Voltage Range ma ma 700 ma 176~305 Vac 160~357 Vdc 250W 93% 0.98 EBD-255S105DV

Transcription:

Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications................. 5 Accessories and Options................. 9 Software....................... 10 Component Tests: Insulation Test System 1

Brief Overview of Phenomena General Insulation plays a great role in electro-technology, as well as electric power generation, power distribution and loads. Insulation can be stressed by a number of factors. Slowly increasing over voltages can be generated by transmission line switching, turning off heavy loads, switching of capacitive or inductive currents or by lightning strikes on power lines. The disturbance time is in the order of ms. Fast increasing over voltages are generated by switching actions related to failures and lightning in power lines and switch yards. Disturbance times are in the order of µs. Also, lightning in the vicinity of transmission power lines can induce over voltages. Very fast increasing over voltages are generated by switching or failures in gas insulated stations or substations (GIS). The very fast switching occurs as a result of high field levels before breakdown occurs in the gas (ns). Despite the fast switching phenomena, gas insulation has many advantages over conventional methods. The main advantage is that voltage withstand capability does not change with time, whereas oil/paper or solid insulators degrade with time or can even be destroyed by partial discharges. Insulation tests are to ensure that there is no breakdown or repeated flash over. Several test methods can be employed. A.C., D.C. and peak impulse are alternative test methods. It is sufficient that the equipment passes any one of the three. Impulse tests have the advantage of reduced power dissipation in the components and protection devices can be left in circuit. EMC Partner voltage Insulation Test Systems are applied to ensure the safe operation of transformers, cables, switches and a multitude of other products. The 1.2/50 µs voltage wave is used for impulse insulation tests. Impulse testing is performed on components and assemblies either during production or post installation as part of a routine maintenance regime. Accurate monitoring and assessment of the impulse wave shape is an essential part of the test as voltage breakdown is indicated by a change in the waveshape. 1.2/50us voltage impulse Impulse transients can be generated by external events such as lightning or internal events like switching. The result is a voltage impulse with low energy content that appears between windings in transformers, between power lines or across physical gaps between conductors and cases etc. A normalised voltage impulse of 1.2/50us is defined in the standards IEC 60060-1 and IEC61180-1. 1.2/50us voltage & 8/20us current impulses Surge events can be generated by lightning phenomena, switching transients or the activation of protection devices in the power distribution system. A surge itself is influenced by the propogation path taken so that impulses from the same event may have different forms depending upon where a measurement is taken. Combination Wave Generators (CWG) simulate a surge event in power lines close to or within buildings they are energy rich and should breakdown occur, an impulse current will be available that is an additional stress. 2 Component Tests: Insulation Test System

Applicable Standards International Electrotechnical Committee (IEC) IEC 61000-4-5 Ed2 (2005) Electromagnetic compatibility (EMC) Part 4-5: Testing and measurement techniques - Surge immunity test IEC 61180-1 Ed1 (1992) High-voltage test techniques for low voltage equipment Part 1: Definitions, test and procedure requirements IEC 60060-1 Ed2 (1989) High-voltage test techniques. Part 1: General definitions and test requirements IEC60335 IEC 61730-2 Ed1 (2004) Photovoltaic (PV) module safety qualification Part 2: Requirements for testing IEC 60664-1 Ed2 (2007) Insulation coordination for equipment within low-voltage systems Part 1: Principles, requirements and tests IEC 60065 Ed7.1 (2005) Audio, video and similar electronic apparatus Safety requirements IEC 61010-1 Ed2 (2002) Safety Requirements for Electrical Equipment for Measurement, Control and Development use. Part 1 - General Requirements Test System Overview Test System Features The Insulation Test System has many unique and outstanding features: - Insulation test 40Ω - Insulation test 500Ω - Insulation test 0.5Joule - Combination Wave Tests - Voltages from 250V up to 96kV - Integrated personal safety - Integrated measurement - Voltage ramp features - Electronic polarity change - Semiconductor switches - Compact designs - High degree of automation without software - 2 year warranty Component Tests: Insulation Test System 3

User Benefits The technical excellence and many unique features of EMC PARTNERS Insulation testers translate directly into benefits for the user. - Range of voltage / impedance combinations to meet multiple Applications - Standard control unit, reduces user training - Measurement system delivers information about insulation breakdown - Integration into existing test facilities saves engineering costs. - Pass / Fail indication for individual samples, speeds up production - High degree of automation, reduces operator workload - Save operator time with the automated test routines and test report facility. - Unparalleled reliability and system up-time Generators A range of generators are available to cover dielectric withstand tests up to 144kV. The generators all employ a patented EMC PARTNER voltage module that enables the same topology to be used for a generator capable of 6kV or 144kV. The same control unit and software is common across the whole range. For all generators, the most significant test parameters can be programmed as fixed values on the instrument front panel or using one of the EMC PARTNER software packages. - MIG0603 Impulse voltage tester 1.2/50µs voltage range 0.5kV up to 6kV. Series resistor 40ohm - MIG1203 [Ideal for testing photovoltaic equipment] Impulse voltage tester 1.2/50µs voltage range 1kV up to 12kV. Series resistor 40ohm - MIG1803 Impulse voltage tester 1.2/50µs voltage range 1kV up to 18kV. Series resistor 40ohm Photovoltaic modules - MIG1803-12 Impulse voltage tester 1.2/50µs voltage range 1kV up to 18kV. Series resistor 500ohm. Combination wave 0.25kV up to 18kV. Virtual impedance 12ohm - MIG2403 Impulse voltage tester 1.2/50µs voltage range 2kV up to 24kV. Series resistor 40ohm - MIG3603C Impulse voltage tester 1.2/50µs voltage range 2kV up to 36kV. Series resistor 500ohm. Impulse voltage tester 1.2/50µs voltage range 0.25kV up to 6kV. Series resistor 500ohm. Impulse voltage tester 1.2/50µs voltage range 2kV up to 36kV. Source impedance 12ohm. Combination wave 0.25kV up to 6kV. 0.125kA up to 3kA. Virtual impedance 2ohm - MIG4803 Impulse voltage tester 1.2/50µs voltage range 2kV up to 48kV. Source impedance 50ohm. Combination wave 0.25kV up to 6kV. 0.125kA up to 3kA. Virtual impedance 2ohm - MIG14403 [where flexibility meets accuracy] Insulation tester 1.2/50µs with two source impedances: 48 Ohm and 500 Ohm. 48 Ohm output: v = 1.2/50µs up to 144kV, i max 3000A, waveform approx. 8/20µs. 500 Ohm output: v = 1.2/50µs up to 144kV, i max 288A. Generators with lower voltage, extendable up to 144kV with 24kV HV stages (STAGE2403) are also available. 4 Component Tests: Insulation Test System

Generator Specifications MIG0603 0.25 up to 6kV 10µF 40 Ω 200 Joule MIG0603 MIG1203 0.5 up to 12kV 5µF 40 Ω 420 Joule MIG1803 MIG1203 0.75 up to 18kV 3.33µF 40 Ω 630 Joule MIG1803-12 MIG1803 0.2 up to 18kV 1.67µF 12Ω, 500Ω 280 Joule MIG1803-12 Component Tests: Insulation Test System 5

Impulse Current 8/20µs 0.2 up to 18kV 1.67µF 12Ω 280 Joule Pulse front time 8 µs Pulse duration 20 µs MIG2403 1 up to 24kV 2.5µF 40 Ω 840 Joule MIG2403 MIG3603C 2 up to 36kV 1.67µF 1110 Joule 12 Ω Short circuit waveshape 8/20 µs MIG3603C Combination Wave 1.2/50µs (8/20µs) 0.25 up to 6kV 10µF 2 Ω 180 Joule Short circuit waveshape 8/20 µs 0.25 up to 6kV / 2 up to 36kV 500 Ω Short circuit waveshape 8/20 µs 6 Component Tests: Insulation Test System

MIG4803 2 up to 48kV 10µF 50 Ω Combination Wave 1.2/50µs (8/20µs) 0.25 up to 6kV 10µF 2 Ω 180 Joule Short circuit waveshape 8/20 µs MIG4803 0.25 up to 6kV 10µF 50 Ω 180 Joule MIG14403 System 24kV stages starting from 72kV (MIG7203) up to 144kV 2.2uF 48 Ω and 500 Ω 650 Joule MIG14403 4 up to 144kV 4 digit plus comma 375 nf 48 Ω and 500 Ω 3900 Joule positive, negative alternating up to 2 stages (48kV) MIG14403 MIG7203 (72kV), MIG9603 (96kV) and MIG12003 (120kV) are upgradable with STAGE2403 up to 144kV STAGE2403 Component Tests: Insulation Test System 7

Insulation Testing Insulation Testing TEMA TEST MANAGER customized solution DSO Option control TEK DSO MIG0603 MIG1203 MIG1803 MIG1803-12 MIG2403 MIG3603C MIG4803 MIG14403 CN-MIG24 TC-MIG24 EUT Insulation Testing Applications TEMA TEST MANAGER customized solution DSO Option control TEK DSO MIG1203 MIGOPTION STEP MIG2403 MIGOPTION UIC EUT Power AC & DC NW-IEC60065-1 NW-IEC60065-1A CN-MIG18AMP MIG-COMAT36 EUT 8 Component Tests: Insulation Test System

Accessories and Options TC-MIG24 A test cabinet for EUT with maximum dimensions 12 X 15 x 28cm. Can be used together with MIG 1206, MIG1809 and MIG2412. TC-MIG24 is linked to the MIG 1206, MIG1809 and MIG2412 safety circuit. Opening the test cabinet disables test voltages. Safety circuit status is indicated by red and green lamps in the test cabinet. TC-MIG24 CN-MIG-24 Accessory to MIG1206SPD insulation circuit ONLY. Two test pistols with integrated red and green warning lamps. CN-MIG-24 CN-MIG4803 Connection box with 2 connection cables to EUT. Cable length 1.5m one red, one yellow, equipped with alligator clips at the EUT side. Personal safety at user own risk. NW-IEC60065-1 up to 10kV in accordance with IEC / EN 60065. Impulse capacitance 1nF. Requires MIG1203 and MIG OPTION STEP. NW-IEC60065-1A NW-IEC60065-1 up to 10kV in accordance with IEC / EN 60065 >/= Ed.7: without 4 Mohm parallel resistor. Impulse capacitance 1nF. Requires MIG1203 and MIG OP- TION STEP. MIG OPTION UIC to MIG2403 Extends MIG2403 with a coupling network to superimpose the 1.2/50µs impulse to train power supplies: 3000Vd.c.; 1500Vd.c., 1500Va.c. 50Hz, 1000Va.c. 16 2/3Hz in accordance with UIC 550. COVER BOX SMALL or LARGE Cover box for customized connection of generators with high voltage output on top. SMALL: Dimension 24 x 8 x 8cm. LARGE: Dimension 30 x 23 x 8cm. COVER BOX SMALL COVER BOX LARGE MIG OPTION STEP OPTION STEP to MIG1203. Must be ordered together with NW-IEC60065-1 or NW- IEC60065-1A. STAGE2403 Extends the generators MIG7203, MIG9603 or MIG12003 up to 144kV. MIG14403 requires 6 stages. Extension of; MIG7303 max. 3 stages, MIG9603 max. 2 stages, MIG12003 max. 1 stage. Generator extention must be made at EMCP. STAGE2403 Component Tests: Insulation Test System 9

Software For remote control of Insulation Testers, an OPTICAL LINK and one of the following software packages is needed: - GENECS-MIG: This is a relatively simple program that reproduces generator front panel functions on a PC. In addition to remote programming and control of the generators, test report information is available to word processing or other evaluation programs such as EXCEL. - TEMA Software: Comfortable control of EMC PARTNER generators from a PC. Enables up to four generator types to be included in the same test sequence. Generates an enhanced test report. GENECS MIG TEMA software 10 Component Tests: Insulation Test System

EMC PARTNER s Product Range The Largest Range of Impulse Test Equipment up to 100kA and 100kV. Immunity Testers Immunity Tests Transient Test System can be used to performs all EMC tests on electronic equipment. ESD, EFT, surge, AC dips, AC magnetic field, surge magnetic field, common mode, damped oscillatory and DC dips tests are available as stand-alone or combined test instruments. A large range of accessories for different applications is available: three phase couplers up to 690V/100A, telecom and data line couplers, verification sets, magnetic field coils. Immunity test systems fulfills IEC and EN 61000-4-2, -4, -5, -8, -9, -11, -12, -16, -18, -29. TRA3000 and ESD3000 ideal for CE testing Lightning Easily extended to meet other applications Lightning Tests A range of test equipment and accessories for aircraft, military and telecom applications. Complete solutions including all hardware and software to meet the requirements of RTCA / EUROCAE DO160 / ED14 for indirect lighting on aircraft systems, MIL-STD-461 tests CS106, CS115, CS116, for military vehicles, ITU-T.K44 basic and enhanced tests for impulse, power contact and power induction, FCC part 68 for telecom equipment testing. Testers www.emc-partner.com MIG2000-6 a flexible solution for military and avionic applications Component Tests Modular impulse generators (MIG) for transient component testing on: varistors, gas discharge tubes (GDT), surge protective devices (SPD), X Y capacitors, circuit breakers, watt-hour meters, protection relays, insulation material, suppressor diodes, connectors, chokes, fuses, resistors, emc-gaskets, cables, etc. Manual or fully automated solutions are available up to 100kA (8/20us) and 144kV (1.2/50us). MIG1212CAP an automatic 8 bank capacitor test system www.emc-partner.com Emission Measurement Emission Measurements One unit performs all measurements on the power supplies of electronic equipment and products for the CE-Mark. HAR1000 uses a novel techniques to deliver clean power source for the EUT in a compact and lightweight form. The system includes all hardware and software including line impedance networks, control and evaluation software. A basic 1-phase system can be easily extended to 3-phase by adding 2 further phases. HARCS Immunity software further expands the system by addidng interharmonic tests, voltage variation and ripple on DC tests. Complies with IEC / EN 61000-3-2, -3 IEC / EN 61000-4-13, -14, HAR1000-3P and HARCS software a complete test system System Automation System Automation As addition to the basic generators, a range of accessories are available to enhance capability. Test cabinets, test pistols, adapters and software, simplify interfacing with the EUT. www.emc-partner.com PS3 programmable source is an EMC hardened supply for frequencies form 16.7Hz to 400Hz. Frequency variation tests can be made using the PS3-SOFT-EXT. Complies with IEC / EN 61000-4-28 PS3 - programmable source ideal for EMC applications Component Tests: Insulation Test System 11 www.emc-partner.com

For further information please do not hesitate to contact EMC PARTNER s representative in your region. You will find a complete list of our representatives and a lot of other useful information on our website: www.emc-partner.com The Headquarters in Switzerland EMC PARTNER AG Baselstrasse 160 CH - 4242 Laufen Switzerland Phone: +41 61 775 20 30 Fax: +41 61 775 20 59 Email: sales@emc-partner.ch Web-Site: www.emc-partner.com Your local representative 12 Component Tests: Insulation Test System Version 3. June 2010. Subject to change without notice.