Model A Milliohm Resistance Tester Operators Manual

Similar documents
Harris IRT Enterprises, Inc. Digital Resistance Tester Model A

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Model Hz to 10MHz Precision Phasemeter. Operating Manual

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

Model 7000 Low Noise Differential Preamplifier

2006 MFJ ENTERPRISES, INC.

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

LAUREL ELECTRONICS, INC.

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

MFJ ENTERPRISES, INC.

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

T25-35SA Subaudible Tone Decoder

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Detcon Model FP Transmitter Test Fixture Operators Instruction Manual June 17, 2008 * Document 3389 * Revision 1.1

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

Line-to-line RMS Volts, 3 phases 4 digits (XXX.X) Volts

OHIO SEMITRONICS, INC. DIGITAL AC POWER MONITOR OSI SPECIFICATIONS

B MTS Systems Corp., Model Function Generator

DC Resistance Meters 2840 Series

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

Uni-Mux XQL Multi-Channel Data Acquisition Module

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

DM8010 tm. Hardware Reference Manual. Document Revision B3 May 16, 2018

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

Process Calibrator. TechChek 820

Ocean Controls KT-5221 Modbus IO Module

41P Portable Calibrator User Manual

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

PI-150 Broadband Power Indicator

INSTRUCTION MANUAL LKG

BROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

MFJ ENTERPRISES, INC.

TOSHIBA International Corp

HUMIDITY/TEMP. CONTROLLER/MONITOR

SDI SPECTRADYNAMICS, INC GHZ RUBIDIUM FREQUENCY SYNTHESIZER OPERATING MANUAL

T L Audio CRIMSON SERIES. User Manual EQ-3011 EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Automated Thermocouple & RTD Calibrator

Model 1737 Dual Range DC Power Supply

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PH METER OPERATION MANUAL. Model : PH-208

Multiple Instrument Station Module

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

PI-10 Broadband Power Indicator

True RMS Bench Multimeter 5492B

INSTRUCTIONS PS2500 POWER SUPPLY

DR3535 DR3535-O. Hardware Reference Manual. Document Revision A7 May 16, 2018 MICROKINETICS CORPORATION

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Programmable K-Factor Scaler B and Programming Software Kit B

AD-8100 & AD-8200 Servo Amplifiers

3100LA Broadband Power Amplifier

Thruline RF Directional Wattmeters

A 500 Broadband Power Amplifier

Operator Manual 1.4 FRACSIM MINI

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

OVEN INDUSTRIES, INC. Model 5C7-362

Agilent E3633A and E3634A DC Power Supplies

45EMD Portable Calibrator User Manual

HQ-31 HQ-15 USER S GUIDE SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER

Microprocessor Control Board Set Up Procedures (OR PLC)

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

EN SERIES NEMA CASED DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

Trillium US Inc. E500 Dual Channel Temperature Monitor User s Manual Rev A / November 2015

Opus 21 s80 Integrated Amplifier Owner's Manual

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

Operating Instruction Manual ELECTRONIC MUSIC AMPLIFICATION SYSTEM. Model KD-1. Toa Electric Co., Ltd. KOBE, JAPAN

R-X SERIES. Decade Resistor

MODEL 25D MANUAL PRODUCT OVERVIEW:

TRANSDUCER IN-LINE AMPLIFIER

DCS-E 1kW Series & DCS-E 1.2kW Series DC Power Supplies

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

Blue Point Engineering

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

TRANSDUCER IN-LINE AMPLIFIER

Hardware Guide. Control Made Simple. Model 401A Signal Generator

INSTRUCTION MANUAL. March 11, 2003, Revision 3

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

The wireless alternative to expensive cabling...

441 DUAL CHANNEL 15 BAND 2/3 OCTAVE GRAPHIC EQUALIZER 451 SINGLE CHANNEL 31 BAND 1/3 OCTAVE GRAPHIC EQUALIZER

Model 34A. 3Hz to 2MHz 2-Channel Butterworth/Bessel HP, LP, BP, BR Plug-In Filter Card for Model 3905/3916 Chassis.

Instruction Manual RCI-100-XXX. Remote Control Signal Interface

CMP-300 Composite Mixer/ Distribution Amplifier

Isolated Variable AC Line Supply Instruction Manual

Transcription:

Model 5060-05A Milliohm Resistance Tester Operators Manual (C) 2003 HARRIS IRT ENTERPRISES, INC. ALL RIGHTS RESERVED

Harris IRT Enterprises, Inc. Digital Milliohm Resistance Tester - Model 5060-05A Equipment Configuration Specifications & Dimensions Theory of Operation Operation of Unit Calibration Procedure Options RS-232 Configuration BCD Configuration Temperature Compensation Procedure Trouble Shooting Hints Return Policy Warranty Assembly Drawings 2 3 4 5 7 8 9 10 11 14 15 15 16 05/27/03 1

EQUIPMENT CONFIGURATION: Resistance Tester Model 5060-05A, serial number, is equipped with the following options as indicated. Temperature Compensation at for RS-232 Computer Interface Binary Coded Decimal Computer Interface Remote Range Select Sample and Hold Safety Relay 230 VAC Service Diode Polarity Test Foot Switch Buzzer Other 05/27/03 2

SPECIFICATIONS ACCURACY (% FULL SCALE) RANGES DISPLAY READING RATE TERMINALS POWER REQUIREMENTS TEST CONNECTIONS CONNECTORS LIMIT ALARM TERMINALS +-0.0 (Includes +/- 1 digit) at 25 o C +-0.00 per o C from 0 to 70 o C 0 to 1.999, 19.99, 199.9, 1.999K, 19.99K Milliohms 3 1/2 digit LED 4 readings per second (minimum) Max. Full-scale voltage is 2.0 Volts and less than 1Amp. Current 117 VAC +/- 10 %, 50-60 Hz, 5 Watts. 2 amp Slo-Blo fuse (230 VAC optional) 4 wire Kelvin required Rear panel MS-style circular connector and front panel banana jacks Dry contacts rated at 5A. At 117 VAC DIMENSIONS 05/27/03 3

THEORY of OPERATION: The Harris IRT Enterprises Model 5060-05A Milliohm Resistance Tester is a digital millohmmeter that includes a precision constant current source which drives a known current through an unknown resistance. It features four readings per second and a temperature compensated voltage reference serving both the DVM and the constant current source. This results in a stable calibration reference. A digital voltmeter measures the potential across the resistance and presents a digital display of the resistance in Ohms. CMOS circuit construction includes a dual limit comparator which compares the measured resistance with upper and lower tolerance values entered on front panel thumbwheels. Red and green front panel lights indicate whether or not the resistance is within tolerance. An output relay permits the resistance tester to be converted to a rejection device. For "fail-safe" operation the contacts are normally open. The contacts close if the part is within tolerance. BLOCK DIAGRAM: 05/27/03 4

OPERATION of UNIT FRONT PANEL VIEW: 1) Green light indicates that the part under test is within tolerance. 2) Front panel banana jacks allows a 4-wire Kelvin connection to be made. 3) Select LOW limit. Red light located above LOW limit thumbwheel switches indicates that the part under test is below tolerance. 4) Select HIGH limit. Red light located above HIGH limit thumbwheel switches indicates that the partunder test is above tolerance. 5) Range select knob. Rotate to correct range. Resistance of the part under test appears on the LED display. A flashing "0000" display indicates that the RANGE SELECTOR (5) is set lower than the resistance being measured. REAR PANEL VIEW: 6) Power cord. Connect to 117 VAC 50-60 Hz. Optional 230 VAC operation available. 7) Fuse holder. Use a 2 Amp Slo-Blo Fuse. 8) Temperature compensation switch.1 Center position is OFF. 9) Temperature compensation jack for Harris IRT Enterprises, Inc. temperature probe (TC Probe) 2. 10) LM340 KC-5 regulator transistor. 11) 6-pin female MS-style circular connector. 3 12) 25-pin female DB-style connector, for use with RS-232 or BCD. 4 1 Optional equipment. 2 Optional equipment. Order MA1061 for replacement TC probe. 3 Mating connector for rear panel connection is available from Harris IRT Enterprises, part # 97. 4 Optional equipment 05/27/03 5

TEST CONNECTIONS: NOTE: For greatest accuracy each voltage and current lead must connect separately to the component under test. I + V + FRONT PANEL BANANA JACKS UNKNOWN RESISTANCE I - V - B F E A C D I + v + v - I - UNKNOWN RESISTANCE REAR PANEL CIRCULAR CONNECTOR N. O. RELAY CLOSED FOR GOOD PART 05/27/03 6

5060-05A CALIBRATION PROCEDURE REQUIRED EQUIPMENT: A. A digital voltmeter / milliammeter with a 4 ½ digit resolution is required. A Fluke Model 8050A is suitable. B. A set of five standard resistances, one for each range to be calibrated. A precision of at least 0.02% is necessary to calibrate this instrument to specifications. Harris IRT Enterprises, Inc. can supply a 0.02% resistance set, Model 2005, with standard resistances and switchable Kelvin connections. Recommended standard resistance: 1.9990 Milliohms 19.990 Milliohms 199.90 Milliohms 1999.0 Milliohms 19990 Milliohms 4 Wire Short or "Zero" NOTE: The resistances must be just below the full-scale value of each range. C. A set of test leads for a four wire Kelvin connection between the resistance standards and the resistance tester. 1) Place meter on the 2Km range. Connect a "Zero" standard (4-wire short) to the meter. 2) Adjust the potentiometer labeled "ZERO" on the 5012-05A Main PCB Assembly until the display on the meter reads all zeros (0000). (See drawing on page 16 for location of potentiometer.) Disconnect the "Zero" standard. 3) Connect a 20 standard to the meter. Select the 20K range on the meter. Adjust the FSpotentiometer on the 3692041 assembly until the display reads the certified value of the 20 standard. Disconnect the 20 standard. 4) Connect a 2 standard to the meter. Select the 2K range on the meter. Adjust the 200 potentiometer on the 3692041 assembly until the display reads the certified value of the 2 standard. Disconnect the 2 standard. 5) Connect a 199.9m standard to the meter. Select the 200 range on the meter. Adjust the 20 potentiometer on the 3692041 assembly until the display reads the certified value of the 199.9m standard. Disconnect the 199.9m standard. 6) Connect a 19.99m standard to the meter. Select the 20 range on the meter. Adjust the 2 potentiometer on the 3692041 assembly until the display reads the certified value of the 19.99m standard. Disconnect the 19.99m standard. 7) Connect a 1.99m standard to the meter. Select the 2 range on the meter. Adjust the potentiometer located on the 3697116 assembly (1 Amp Option) until the display reads the certified value of the 1.99m standard. Disconnect the 1.99m standard. Model 5060-05A calibration procedure is completed. 05/27/03 7

OPTIONS : TEMPERATURE COMPENSATION ( TC ): Temperature changes of a few degrees in a product can have significant effects on the product's resistance.therefore, the need for temperature compensation may arise when the temperature of the part being tested changes over a period of time. The benefits of temperature compensation include the saving of time, energy, and money by eliminating theneed to refer to coefficient tables as the ambient plant temperature varies during the day. Before now, such compensation was available only in expensive and delicate laboratory-grade instruments. Harris IRT has now made it available in rugged resistance testers designed for use in production. With temperature compensation, a probe sends ambient temperature data to the instrument. This temperatureinformation is used to modify the constant current that is being passed through the part under test. The resistance then registered is the resistance the item under test would have at the specified temperature. The compensation option can be calibrated for the measurement of either of two measurement coefficients or it can be operated without any compensation. The accuracy of the compensation is within 0.2% of the actual resistance between 0 and 50 C. RS-232 COMPUTER INTERFACE ( RS232 ): A three wire link between the resistance tester and a computer can be made through the RS-232 port. This is a standard null-modem connection with an adjustable baud rate (50-19,200) and word length of 8 bit. This permits the reading shown on the front panel display to be sent to the computer at the set baud rate every time the instrument is sent a character by the computer. This interface is useful for the statistical analysis of production, predictive control, and data logging. It is compatible with any computer having an RS-232 port and any terminal program. Factory settings: 9600 Baud, No stop bit, 8 bit word, No parity, (9600,N,8,1) BINARY CODED DECIMAL ( BCD ): The BCD output allows the resistance tester to transmit readings to a Programmable Logic Controller (PLC). The BCD option generates a 1, 2, 4, and 8 bit for each of the 5 characters in the resistance reading. An output strobe is also provided to allow synchronization of the resistance tester with the PLC. The BCD output is a TTL logic level of 0 to 5 VDC and a maximum output current of 24 ma. REMOTE RANGE SELECT ( RR ): The remote range select option is typically used in on-line testing when various resistances must be tested.this option allows a PLC or other controller on the production line to set the range of the resistance tester. This option is usually used in conjunction with the BCD or RS-232 options. SAMPLE and HOLD ( SH ): This option permits the measurement of a component's resistance `on-the-fly' even though the contact timewith the component is very brief (a few milliseconds). It is possible to hold a resistance reading for digital processing and display. 100 % testing is possible under such conditions. SAFETY RELAY ( RY ): When a resistance tester is used in conjunction with high pot or surge tests, an internal safety relay can beprovided to lock-out the resistance tester circuitry during other testing. This will protect the resistance tester from possible high-voltage or high-current damage. 05/27/03 8

RS-232 SERIAL INTERFACE OPTION The Harris IRT Serial Interface Option provides a simple method for gathering resistance measurement data from any Harris IRT Resistance Tester. This option is frequently used to implement continuous data logging for SPC and ISO9000 programs or to permit complete computer control of an automated production testing station. FUNCTIONAL DESCRIPTION: The RS-232 serial option connects to the Binary Coded Decimal (BCD) output from the Analog to Digital Converter, and to each of the five available digit strobe lines. Each time an LED display digit is updated, the BCD data is captured and stored in the serial option memory location for that digit. A transmission of the last five characters, most significant digit first, is sent whenever a data request is received. No decimal point or other delimiter character is sent with the five numerical digits. In the factory default configuration, any character received at the setup baud rate and protocol, will serve to request a five digit data report. If a carriage return, or semicolon is used for the request character, most spreadsheets can directly import the reported data, using the request character as a delimiter. Optionally an external normally open switch can be used to request a data report. See the assembly drawing below for the switch terminal locations. Any good computer terminal program can be used to collect and store the collected data. Make certain that the serial port being used is configured for 'no control', as there is no x-on/x-off or hardware control of the data provided with this option. This mode can be selected in Window by changing the Comm Port Properties in System Setup. BAUD RATE SETTINGS: Four pre-programmed standard baud rates are available from the Serial Interface Option. The factory default protocol setting is 9600,N,8,1. There are no longer any options available for a 7-bit word protocol. The other Baud rates can be selected by using the jumpers available on the serial option board. See the assembly drawing below for jumper locations. Baud Rate Jumpers: (select one jumper only) No Jumper 9600 baud (default) J1 300 baud J2 1200 baud J3 19.2K baud J4 57.6K baud The RS-232 Serial Interface Option now contains a microprocessor based communications port. Because of this feature, it is possible to request non-standard data reports, RS-485 network configuration and many other custom features. If the standard product does not fill your needs, please inquire with Engineering about custom software that may already be available. 05/27/03 9

BCD OUTPUT and REMOTE RANGE SELECT CONFIGURATION: The BCD and Remote Range Select options are supplied with a FEMALE DB-25 style connector located on the rear panel with the following connections. Pin Number Data Explanation 1 1 MSD 2 2 3 1 4 2 2nd 5 4 Digit 6 8 7 1 8 2 3rd 9 4 Digit 10 8 11 1 12 2 4th 13 4 Digit 14 8 15 1 LSD 16 2 17 4 18 8 19 Range #5 Highest Range (Default) 20 Range #4 21 Range #3 22 Range #2 23 Range #1 Lowest Range 24 Data Ready 25 Common Pins 1 through 18 are TTL-buffered BCD data output from a 74LS244 buffer. Data common is available at Pin 25. Pins 19 through 23 are range selector pins. Ranges are selected by connecting these pins one at a time to common (Pin 25). If no range is selected, the unit will default to the highest range (20K). Data is valid only while the Data Ready pulse on Pin 24 is high. This pulse has a 10% duty cycle. Data taken at any other time may be invalid because digits are strobed sequentially. 05/27/03 10

TEMPERATURE COMPENSATION PROCEDURE PRE-CALIBRATION PROCEDURE: Plug the Temperature Compensation Probe into the stereo jack located on the rear panel. Using a Voltmeter, measure the voltage between the green and gray wires on the stereo jack located on the rear panel. The measured reading should be approximately 2.73 Volts +10 mv per C. For example, the room temperature is 25 C. The voltage reading should be about 2.98 Volts. If the voltage reading is more than +-20 mv from the calculated reading or the reading is 12 V, then the TC probe is defective. Replacement TC probes can be ordered from Harris IRT Enterprises, Inc. as part # MA1061. Note: TC probes are not interchangeable without re-calibration. PREPARING THE WATER BATHS: Three water baths will be needed for proper calibration: One bath at the SPECIFIED temperature, a HOT bath at +20 C from the specified temperature and a COLD bath at -20 C from the specified temperature. For example purposes, the specified temperature is 25 C. Using a Celsius thermometer prepare one bath for 25 C, a HOT bath at 45 C and a COLD bath (using ice cubes if necessary) at 5 C. It is important that enough water is used in each bath so that room temperature will not effect the temperatures of the baths before the calibration is complete. Also make sure that the specified bath is EXACTLY what the temperature should be. Temperature Compensation PC Board 1 2 3 LF356 1K 1K 200 2.0K LM336-5V 3.01K 15K 1K 2K 2.2K 1M 3EA. 1M 05/27/03 11

CALIBRATION PROCEDURE: 1) Plug the temperature compensation probe and the resistance standard into the rear of the resistance tester. 2) Set the resistance tester to the 2Km range. Make sure the temperature compensation switch located on the rear panel is in the OFF (center) position. 3) Place the TC probe and the resistance standard into the specified temperature bath. Stir the TC probe and the resistance standard a few times until the readings stabilize. After the display stabilizes (usually a few minutes) record the reading. Step #3 Reading 4) Switch the temperature compensation switch to the Cu/A1 (right) position. 5) Adjust POT #3 until the display reads the same as the recorded reading in Step #3. Switch the temperature compensation switch to the Alloy (left) position. Adjust POT #3 until the display reads the same as the recorded reading in Step #3. Make sure no change occurs when switching through all three positions of the temperature compensation switch. Return the temperature compensation switch to the Cu/A1 position before proceeding. 6) Place the TC probe and the resistance standard into the HOT bath. Stir the TC probe and the resistance standard a few times until the display stabilizes (usually a few minutes), adjust POT #1 until the display reads the same as the recorded reading in Step #3. 7) Place the TC probe and the resistance standard into the specified temperature bath. After a few minutes, place the TC probe and the resistance standard into the COLD bath. Stir the TC probe and the resistance standard a few times until the display stabilizes. Record the reading. Step #7 Reading 8) Subtract the reading from Step #7 from the recorded reading in Step #3. Divide the ANSWER by 2. Add this result to the original reading in Step #7, and record the result. Step #3 reading Step #7 reading Answer/2 = + Step #7 + Answer = Step #8 result 9) Adjust POT #1 until the display reads the same as the recorded result in Step #8. 10) Switch the temperature compensation switch to the OFF position. Record the displayed reading. Step #10 Reading 05/27/03 12

11) Subtract the reading from Step #10 from the recorded reading in Step #3. Divide the ANSWER by 2. Add this result to the original reading in Step # 10, and record the result. Step #3 reading Answer / 2 = Step # 10 reading Answer = = Step # 10 + Step #11 result 12) Switch the temperature compensation switch to the Alloy position and adjust POT #2 until the display reads the same as the recorded result in Step #11. 13) Turn the temperature compensation switch to the OFF position. The temperature compensation procedure is completed. 05/27/03 13

TROUBLE-SHOOTING HINTS SYMPTOM: The Resistance Testers display flashes 0000 no matter what resistance is being measured. POSSIBLE SOLUTIONS: The Resistance Tester is in over-range mode, select a higher range. The ICL7135 CPI A/D converter could be burned-out. This IC is socketed and can easily be replaced by the user 1. SYMPTOM: The Resistance Tester displays changing numbers or garbage readings. POSSIBLE SOLUTIONS: Check to make sure a load is connected to the Resistance Tester via the back panel circular connector or front panel banana plugs. Check to make sure you have a true 4-wire Kelvin connection. SYMPTOM: Readings appear to be incorrect. POSSIBLE SOLUTIONS: Check to see that the Temperature Compensation probe is plugged in all the way and that the Temperature Compensation switch is in the correct position. Check to see if the Resistance Tester is due for calibration. A calibration should be performed once a year. One or more of the MAX400 (or alternate OP177) op-amps could be burned-out. These IC s are socketed and can easily be replaced by the user 1. Check to make sure you have a true 4 wire Kelvin connection. NOTE: Resistance changes as temperature changes. If the ambient temperature varies during the day so will the resistance of the part under test. This could make it appear that the Resistance Tester is not working properly. You may require the use of Temperature Compensation. For Technical assistance call Harris IRT Enterprises, Inc. Phone (740) 881-5508 Fax (740) 881-4630 1 Opening the meter to replace any IC s could void the manufacturers warranty. 05/27/03 14

RETURN POLICY NOTE: Before returning a Resistance Tester for repair or calibration you must first call and receive an RMA#. Any package received without an RMA# may be delayed in the service department. Please write the RMA# on the package and packing slip. To return a Resistance Tester for repair after you receive an RMA# ship to: MANUFACTURER'S WARRANTY Harris IRT Enterprises, Inc. Resistance Tester Service Department 3276 Home Road Powell, Ohio 43065 Phone: (740) 881-5508 Fax: (740) 881-4630 Equipment shall meet all engineering performance data and design requirements described in the specifications. Within a period of one year from the date of shipment, if the equipment should fail to function due to a defect in parts or workmanship, Harris IRT Enterprises, Inc, at its option, will replace or repair the equipment at its facility in Powell, Ohio. NOTE: Removing the calibration seal and performing unauthorized repairs will void the calibration and could void the manufacturers warranty. Please call Harris IRT Enterprises before performing any repairs. 05/27/03 15

MODEL 5060-05A MAIN PCB ASSEMBLY DRAWING 104 Zero Adjust ZERO HI LO V 20K 502 10X GAIN 10X Gain 20K 20K DP 1 2 3 C 100K 10 MAX400.033 MAX400.033 7EA. 10 msd lsd C 2K 200 20 2 1 2 4 8 1 2 4 8 100K 4EA. 22K 4EA. 22K 200K 4.7K 200K 82pf 100K 2.2K 4049 75491 7447 74C85 74C85 4050 2.2K HI LO I 0.1 2.2K 2N2219 2N2219 2N2219 2N2219 10 47K 47K 47K 47K CA100UF 20V 22K.01 3EA..01 10 LM336Z 5.0 16DIPSOCKET 4066 4042 4066 4050 ICL7135 22K 22K 2.2K 10 1N4148 8.2K 4EA. 22K 4ea. 1N4148 100K 22K.1 1.0 1.0.22 0.1 10 2EA. 100K 47 1/2W NE558.01 4013 4011 4013 4011 2.2K 2EA. 2.2K 100K 22K.01.01 2EA. 2.2K 8.2K 8.2K 4013 200K 20K 20K 2K 2K 200 200 20K 20 1K 10UF 35V 680 LF356 LF356.01.01 LM3999Z 30.1K 1M 1M 2.2K 2200UF 35V 1K 2K 1MEG 200K 20K 2K 2N2905 10UF 35V 7912 10UF 35V 7812 4EA. 1N4005 1K 1M 2EA. 1M 3.01K 4.99K 2200UF 35V FS R 2K 200 20 2 100 2W 0.1 0.1 Ac Ct Ac This drawing copyright 1995 by Harris Instrument Corp. This drawing contains information which is the proprietary property of Harris Instrument Corp. Copies may not be made or the contents disclosed beyond the expressed authorization of Harris Instrument Corp. and this print shall be returned upon request. MAIN BOARD 11-19-95 A A 9 2 0 4 1 05/27/03 16

MODEL 5060-05A RS-232 ASSEMBLY DRAWING MODEL 5060-05A TEMPERATURE COMPENSATION ASSEMBLY DRAWING 1K 1K 1K 2K LM336-5V 2.2K LF356 1M 3EA. 1M 2.0K 200 TOP ON PURPLE OFF 15K BLUE/WHT ON BLUE PURPLE BLUE BLUE/ WHT BLUE RED 3.01K BLACK GREEN GREY GREY VIEW N/C GREEN GREY This drawing copyright 1995 by Harris Instrument Corp. This drawing contains information which is the proprietary property of Harris Instrument Corp. Copies may not be made or the contents disclosed beyond the expressed authorization of Harris Instrument Corp. and this print shall be returned upon request. TEMP. COMP BOARD A81004N 9-11-95 05/27/03 17

MODEL 5060-05A CHOPPER STABILIZED PRE-AMP ASSEMBLY DRAWING 05/27/03 18