Solid Sample Holder Accessory

Similar documents
Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine

Film Holder Accessories

Automated Double Aperture Accessory

Installation Guide Philips MP80/90 Installation Kit for Penlon Anesthesia Machine

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

Cut-True 16M Manual Paper Cutter

POP PLUS / SPIDER SET-UP INSTRUCTIONS

Installation Guide Installation Kit for Mounting Philips MP20/30/40/50/60/70 on GE Healthcare Aisys Carestation

Installation Instructions

Assembly Instructions Please keep for future reference Inspire 40

Installation Guide Philips MP40/50/60/70 Installation Kit for Penlon Anesthesia Machine

Tradewinds Amplify Display System Instructions

How to Operate Hurricane Shutters

Maintenance Information

Orbital Truss Kiosk 02

DELUXE UNIVERSAL HEARTH GATE

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

Please read these instructions before use and keep for future reference

ASSEMBLY INSTRUCTIONS FOR SL500A AND SL500AL

Hinge Door + Side Panel

SINCE 1922 P UBLICATION N O

AIR MASTER SYSTEMS INSTALLATION GUIDE TABLE OF CONTENTS

Removing and Replacing the Y-truck

Steele TV Stand Stock # BH

Hinge Door + One Inline Panel

Kontax Stirling Engines KS90T instructions

Kontax Stirling Engines KS90R instructions

Maintenance & Parts list for:

Exponents Bench Cushion

SETUP INSTRUCTIONS If you would like to tell us about your experience with your setup instructions please us at

18600 Angular Momentum

Joiner Kit For Models N388, C450, E402B, E411T, E415H, E440T, E442B, E521T and E522B

Installation Guide. Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

FAIRFAX ROUGHING-IN K-12151T=673. UNIT: mm K-12153T K-12156T K-12151T=610 K-12157T K-12161T T01-A -1- INSTALLATION INSTRUCTIONS

Wooden Frame Type Instruction Manual

Aluminum Frame Type Instruction Manual

600mm COMPOUND MITRE SAW ASSEMBLY INSTRUCTIONS. MODEL NO: MBS600D Part No: GC05/12

CHEMINSTRUMENTS LABORATORY DRAWDOWN COATER LC-100 OPERATING INSTRUCTION

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

MS25 OPERATION MANUAL

mila-wall (Series100) General Operating Instructions page 1 of 15

F594-PLS Platform Beam Scale. Installation/Operation Manual 05.03

Malibu - 3 Drawer 2 Door Robe

WHEN DISASSEMBLING ALUMINUM EXTRUSION, TIGHTEN ALL SETSCREWS AND LOCKS TO PREVENT LOSS DURING SHIPPING

RPMSP Series Installation Guide

Dynamic Nanospray Probe (NSI-1) Installation Guide

REC Series Rack Installation Guide

TECHNICAL INFORMATION GoldPanther Forensic Light Source Kit (Patent Pending) Cat. Nos. FAL2000, FAL

M14 MODULAR CHASSIS SYSTEM (MOD 1) INSTRUCTION MANUAL. West Springfield, MA Phone: (866) FAX: (413)

STOP. V00029AC Rev. 04 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID TOOL LIST. NET-ACCESS S-Type Network Cabinets

Setup. The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on series tables.

CleanBench Laboratory Tables

OWNER S MANUAL. Safety. Please read this owner s manual before use and keep it at hand for reference. Warranty

Formulate Accent Ladder 10

M14 MODULAR CHASSIS SYSTEM (MOD 1) INSTRUCTION MANUAL. West Springfield, MA Phone: (866) FAX: (413)

GCX Mounting Assembly Installation Guide. Drager Narcomed GS Anesthesia Machines with Philips MP60/70 IntelliVue Patient Monitor Kit

Kai Installation Instructions

PACLEASE Hybrid Sacagawea VK-1222 Display Instructions / PAGE 1 - General Layout

Installation Guide. Cabinet Surface Mount for Single Display

MACHINTO FLOATING DOUBLE VANITY SINK ASSEMBLY INSTRUCTIONS. 1. Storage. 1. Keep marble top in its crate until installation.

Nuclear Associates

INSTALLATION MANUAL FRONT. See pages 2 and 3 of this manual for configuration options. Level of Difficulty. Product Photo (center section only)

Sable Frame CineGrey 3D

Constable Oak Extension Dining Table

Vanity Installation Instructions

Laminate Cabinet Installation Instructions

TM12 ASSEMBLY INSTRUCTIONS

RAINBOW TABLE FOOTBALL GAME

Bunk Pod Front Entry Assembly Instructions

1) Place the reactor stand on a sturdy bench with the bottom plate facing toward the front.

INSTALLATION GUIDE FOR METAL LABORATORY CASEWORK

This manual will aid in the assembly of the FireBall V90 and FireBall X90. The assembly of both machines will be identical, unless specified.

Elara NanoEdge Fixed Frame Screen User Guide

MODEL SK61732 COMPRESSOR SERVICE KIT

GMR 1 PROFESSIONAL. ÁU~²Ýœ ÈULM¼« Àπ ß Õ ŸË Õ Èß π Petunjuk-Petunjuk untuk Penggunaan HıÎng dõn s dùng Instructions d emploi. Operating Instructions

Code Product Qty 1 Top Vertex 3 2 Hot End Housing 1 3 Bottom Vertex 3 4 Print Platform Lock 3 5 End Stop Holder 3 6 Filament Feeder Motor Bracket 1 7

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

American Morse Equipment

For assembly see instructions in carton

Due to possible damage in shipping, the vertical stop assembly has been removed from this machine.

3D PRINTER. Pack 11. Anything you can imagine, you can make! 3D technology is now available for you at home! BUILD YOUR OWN

GENERAL OPERATIONAL PRECAUTIONS PRECAUTIONS ON USING CUT-OFF MACHINE

Aeon CineGrey 3D Series

HUTTON FLOATING SINGLE EXTRA WIDE VANIT Y A SSEMBLY INSTRUCTIONS

Vinyl Cutter Instruction Manual

Component Assemblies. A Note on Handling Optics

INVENT3D Printer Kit Disassembly Instructions

Installation Instructions

Build the. Steam Locomotive. Pack 06

How to Assemble Your Solar Light & Accessories

CABINETRY Assembly Instructions

Sabre Series 2 Inspired Design Precision Engineering

A Metal Polishing Jig. By Norm Berls

LED Thin Frame Fixed Frame Screen User Guide

compile system INSTALLATION GUIDE Updated January 2019

Stainless Steel Bench Stand

CM340B STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING SERVER CABINET FROM SKID

Mounting a BalanceBox 400 to a brick wall

IMPORTANT!!! ASSEMBLY ASSEMBLY INSTRUCTIONS. (Internal Dimensions)

Product must be installed as shown using the screws and brackets provided. Use of incorrect hardware could result in damage to the product.

Transcription:

Installation category I Pollution degree 2 Equipment class III Introduction The Solid Sample Holder for the Agilent Cary Eclipse is an accessory that enables you to perform fluorescence measurements on solid samples. It consists of a vertical sample mounting slide supported by optical rails attached to the accessory baseplate. Three optional kits are available for mounting specific types of solid sample. They are: Edge mounting kit Powder holder and single crystal holding kit Cuvette holder kit Figure 1. The Solid Sample Holder accessory. a) The slide d) Optional cuvette holder b) The accessory base e) Optional edge mounter c) Clamps used for attaching samples f) Optional powder holder

Unpacking notes Your accessory is packed in foam-lined cardboard boxes. Check that you have received all of the components listed in the packing list included with the shipment. Installation If you ordered the Solid Sample Holder without any of the additional (optional) mounting kits, follow the standard installation procedure. If you ordered one of the optional kits, follow the installation procedure that corresponds to your kit on the following pages. Standard installation 1 Attach the slide to the accessory base (see Figure 1). To do this: a Completely remove the lower half of the clamping mechanism by taking out the screw that holds the two parts together (see Figure 2 (ii)). Figure 2 showing the screw (ii) separating the lower half of the clamping mechanism (i), and the groove (iii) where one optical rail fits. b Slide the lower half of the clamp under the two optical rails on the accessory base. Orient it so that the cut-out edge is facing the angular adjustment locking screw (see Figure 3 (iii)). (iv) Locating holes (ii) Optical rail (iii) Angular adjustment locking screw (vi) Fastening lever Figure 3 showing (i) how to position the lower half of the clamp (outlined in white) under the optical rails (ii) on the accessory base. Locating holes (iv) and fastening lever (vi) are also labeled. 2

c Re-attach the upper half of the clamp mechanism to the lower half by placing the locating pin into the hole in the center of the lower piece, and inserting and tightening the screw that you removed in step (a). The face if the slide should point towards the label (see Figure 3 on the base of the accessory. 2 Use the rods, clamps and screws contained in the remaining small box, in combination with the tapped holes in the slide face, to mount your sample. 3 You can now place your assembled accessory and sample into the sample compartment. To do this: a Ensure that the Eclipse sample chamber is empty. b Ensure that the Solid Sample Holder baseplate fastening lever (see Figure 3 (vi)) is in the open position (that is, pointing towards the white scale marks). c d Align the two locating holes on the base of the accessory (see Figure 3 (iv)) with the locating pins on the floor at the rear of the sample compartment. Move the fastening lever from left to right to lock the accessory into position. Edge mounting kit installation If you ordered the optional Edge mounting kit, follow the installation procedure below. 1 Follow step 1 of the standard installation procedure. 2 Remove the standard slide by loosening the two screws at the top of the slide holder and sliding the face all the way across. 3 Slide the edge mounting slide face onto the top of the slide holder. The edge mounting pieces attached to the slide should be facing the label (see Figure 3 on the accessory base, and the white grading marks should be at the top. For larger samples, unscrew the two bottom edge mounting pieces using the supplied hexagonal ball screwdriver and remove the top edge mounting piece by unscrewing the thumb screw. Replace these with the supplied large edge mounting pieces. (The piece with the two small guiding pins is the one that is positioned in the center of the slide face. The pins allow it to slot into the tracks.) 4 Slot your sample into the V created by the bottom two edge mounting pieces. Then loosen the screw that holds the central edge mounting piece in place and slide this piece down to secure the sample. 5 Follow step 3 of the standard installation procedure. 3

Powder holder and single crystal holding kit installation If you ordered the optional powder holder and single crystal holding kit, follow the appropriate installation procedure below. To install the single crystal holder: 1 Follow step 1 of the standard installation procedure. 2 Attach the crystal holder (see Figure 4) to the slide face using the two screws provided. The three-holed side should form a shelf. Place your crystal into the hole that most securely holds your crystal. Figure 4. The single crystal holder. 3 Follow step 3 of the standard installation procedure. To install the powder holder: 1 Follow step 1 of the standard installation procedure. 2 Attach the rectangular plate with a semi-circle cut out of it to the face of the slide. Do this using the four screws and the hexagonal ball screwdriver. Ensure the flat side of the plate is facing away from the slide. 3 Position the powder receptacle (see Figure 5 (iii)) with the small silver rod pointing upwards. 4 Using gloves or lens tissue, carefully place a silica disk (see Figure 5 (ii)) into the powder holder receptacle. Beware of contaminating the disk with fingerprints. NOTE The kit comes with a spare silica disk and a spare powder holder receptacle. 5 Put some sample into the powder receptacle, ensuring a thin layer is covering the silica. 6 Place the powder receptacle into the larger powder holder shell (see Figure 5 (iv)). To do this: a b c Grasp the small silver rod of the powder receptacle between the thumb and forefinger. Lift the powder receptacle, keeping it horizontal at all times to avoid spilling the powder. Place the receptacle into the center of the shell cavity. 4

7 Ensuring that the protruding black metal column (see Figure 5 (v)) is on the inside, (in order to securely press the sample up against the silica disk), screw the lid (see Figure 5 (i)) of the powder holder onto the shell. (i) Powder holder (v) Metal column that presses powder against silica disk (ii) Silica disk (iii) Powder receptacle (vi) Rim (iv) Powder holder shell Figure 5. Exploded view of the powder holder. The sample sits between the silica disk (ii) and the column of the lid (v). 8 Take the assembled powder holder and slide the rim (see Figure 5 (vi)) into the semi-circle groove on the accessory slide face created in step 2. 9 Follow step 3 of the standard installation procedure. NOTE When disassembling the powder holder, ensure that the silica disk is facing down when you unscrew the lid, to prevent spillage of powder. Cuvette holder kit installation If you ordered the optional Cuvette holder kit, follow the installation procedure below. 1 Follow step 1 of the standard installation procedure. 2 Attach the cell holder to the slide by aligning the two holes on the cell holder with the two holes at the bottom of the slide and using the hexagonal ball screwdriver to screw in two screws. Ensure that the open side of the cell holder is facing outwards. 3 Insert the cuvette containing the sample. 4 Follow step 5 of the standard installation procedure. 5

Operation The solid sample holder accessory provides both rotational and translational adjustment of the sample. The angle of incidence of the excitation may be varied from 20 35. This is the angle between the exciting light and a line perpendicular to the surface of the sample mounting slide (refer to Figures 6 and 7). The angle of incidence is indicated by the position of the corner of the stage relative to the graduated markings on the accessory baseplate (Figure 6). The markings are at intervals of one degree. The largest mark indicates an angle of incidence of 30. Figure 6: a) Angular adjustment locking screw. b) Corner of stage. Markings indicate the angle of incidence of the exciting light on the sample mounting slide. Figure 7. Angle of incidence of excitation. a) Normal b) Angle of incidence c) Excitation d) Slide To alter the angle of incidence: 1 Loosen the angular adjustment thumbscrew (large thumbscrew). 2 Rotate the stage to the desired orientation. 3 Lock the stage into position by rotating the thumbscrew until finger-tight. It is recommended that you use the Kinetics application to perform this procedure. Alternatively, you can use the Advanced Reads application. To optimize measurement of a particular sample with the solid sample holder accessory, it is recommended that you initially monitor both the fluorescence intensity and the signal intensity at the excitation wavelength. Rotate the accessory stage (Figure 6(b)) to alter the angle of incidence of the exciting light. Samples of varying depth may be moved to the focal position by loosening the thumbscrew that tightens the clamps around the optical rails, and sliding the entire mount forward or backward as required. This ensures the exciting light interacts with the sample directly in front of the emission window thus enhancing the collection of emission. 6

The contribution to the total signal from scattered exciting light is inherently greater when measuring opaque solids as compared to clear (non-scattering) liquids measured at the traditional right angle orientation. For this reason, it is highly recommended that excitation and emission filters be used. This can be achieved using the Cary Eclipse software by setting both the Excitation filter and Emission filter selections on the Options tab of Setup to AUTO. If required, further reduction of scattered excitation could be achieved by placing appropriate cut-off and/or bandpass filters in the filter holders provided in the instrument sample chamber. Specifications Weight Packed Unpacked 3.4 kg (7.4 lbs) 1.5 kg (3.35 lbs) Dimensions (W x D x H) Packed Unpacked 290 x 250 x 250 mm (11.42 x 9.84 x 9.84 inches) 190 x 190 x 200 mm (7.48 x 7.48 x 7.87 inches) Maintenance and cleaning All cleaning should be done with a soft cloth. If necessary, this cloth can be dampened with water or a mild detergent to clean black painted surfaces. Do not use organic solvents or abrasive cleaning agents. 7

This page is intentionally left blank. This information is subject to change without notice. *8510183400* *8510183400* 8510183400 Part Number: 8510183400 Edition 04/12 Issue 3 Agilent Technologies, Inc. 2000, 2011 and 2012 Agilent Technologies 679 Springvale Road Mulgrave, VIC 3170 8