CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Similar documents
WIREFREE CHRONOTHERM FEATURES PRODUCT SPECIFICATION SHEET. CM67RF can be used with Automatic Time Setting module (Q6667B1007)

Wireless Room Thermostat Installation and Operation Y6630D1007

CM900. Our innovative Line of Text (LoT ) display makes the thermostat extremely easy to use. The unique design means that your CM900 is: Easy to read

The CM Range. Clearly different

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

Digital Electronic Thermostat With RF

Control solutions Biofloor

User Instructions For TopTronic RS-10

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Wireless multizone receiver RDE-MZ6

B 520 ELECTRONIC AMBIENT TEMPERATURE CONTROLLERS. RTB C2 Eng. COSTER BUS. B RTB C2 Eng MC REV 01

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

Self-learning Room Temperature Controller Receiver

Control module 2 circuits AD290. Installation and Service Manual

V22 Thermostat N515/R00( )

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C.

LK Wireless Room Control Cq

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

Wireless temperature controller E N RFTC-50/G

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

R7426A. MicroniK 200 TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK

EUROSTER 2026/2026TX

Room Temperature Controller

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Fan Coil Actuator FCA 2

AURATON 2020 AURATON 2020 TX RX Plus

TAC 2112 Manual (GB),

Model 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

Analogue temperature controllers

SRC-110 Series Zone Controllers with Modbus RTU

Wireless Pressure Station with Backlight

Application Programs Descriptions

Wireless Color Weather Station

ATOMIC WALL CLOCK with REMOTE TEMPERATURE SENSOR Model CL Instruction Manual

NRT 105: Electronic fan-coil controller, equiflex

WLDS-10 Mk3 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

Intelligent Compact Controller

Operating instructions. Radio weather station

PACSystems* RX3i IC695MDL765

TLC3-BCR-U Series Thermostat

Sentry Digital Timers

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

TC 204 Heating Controller

S-Series Digital Thermostat

LP20RF & DIGISTAT+RF. Installation & User Guide PRINT. Radio frequency controlled room thermostat with dual channel programmer. Part number RF562DR

OPERATING INSTRUCTIONS Digital weekly time switch

Wireless valve actuator for bidirectional EnOcean communication. The SAB05 combines with message server and enocean transmitter.

User s Manual. F2 Calculator. A metering component for thermal energy applications

* _Ver.1* GP8 Radio CPL Radio DRIVER Energy manager

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

R7420B. MicroniK 100 HONEYWELL TEMPERATURE CONTROLLER PRODUCT DATA GENERAL FEATURES

CONTROL MANUAL. Dry-Pic 09PE - 09VE

Room Temperature Controllers. for heating and cooling systems

Electro Controls. Input-Output Modules WattsIndustries.co.uk

200 RTH OFF ON IN OUT ALARM RESET

Intelligent Installation Systems. ABB i-bus KNX Room Thermostat Fan Coil with Display 6138/11-xx-500 Product Manual

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

Room Temperature Controllers. for heating and cooling systems

Thermo Plus Bluetooth-enabled Thermo-Hygro Monitor Model: RAR213HG USER MANUAL

Alpha IP: Room Control Unit Radio with Display

Y9420S Sundial RF ² Pack 3 INSTALLATION INSTRUCTIONS

Radio controllers. Innovation combined with skill and tradition. Intelligent solutions. for all living spaces. Radio-controlled regulation

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

User Manual OFF ON IN OUT ALARM RESET AURATON RTH software ver. F0F

Electromotoric actuators

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Relay (R1) 003. Balancing Valve. Slab Pump (P1) Max. 4 pipe diameters apart. Injection Pump (P2) 150 No 24V only. Power. Off.

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Digimax 210. Programmable Thermostat. User Guide

ELECTRONIC THERMOSTAT: T920

- Wiring Brochure Universal Reset Module 423e

Room Temperature Controllers. for heating and cooling systems

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual

2025 RTH 2025 P 2025 OFF ON IN OUT ALARM RESET

TC LV-Series Temperature Controllers V1.01

Wireless Pressure Station

Installation Guide. ECL Comfort 310, application A Table of Contents

INSTAT 868 Radio Frequency Single-Room Controls

Wireless Control Systems

1 Digital input (24Vac or dry contact) Inputs

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN

0.01kV (0 to ±0.99 kv)

Please enter the identity code of your device here!

Electromotoric actuators for valves

Fuzzy Temperature Controllers E5AF

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Leica Digisystem i-series Safe and fast location of underground utilities

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

Transcription:

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES CM927 can be installed without disrupting your room décor as no wiring connection is required between the room unit and the boiler Attractive, slim, ultra-modern styling makes it ideal for location in any type of home 7-day heating programming A dynamic text display on the LCD that gives enhanced feedback to the user / installer LCD Backlighting to illuminate the display for easier viewing in low light conditions Reliable RF communication utilising 868 MHz band with 1 % duty cycle limit to minimise communication disturbance Every room unit can be bound with several relay boxes (e.g. to control several electric heating panels) Armchair programmed Party feature that temporarily maintains a selectable constant temperature for 1-23 hours, then returns to normal operation. Day Off button follows Sunday s program for 1 to 99 days, allowing selection of a different heating program without having to re-program the thermostat. Holiday button that provides energy savings by reducing to a constant temperature for 1 to 99 days when people are on holiday, returning to normal operation (AUTO or MANUAL) on the day of their return. EEPROM memory holds the user program indefinitely OFF position has an integral frost protection setting at minimum 5 C (installer adjustable) so that pipes in the house will never freeze in winter. Communication compatibility with other product such as HR80, HM80 and HCE80. PRODUCT SPECIFICATION SHEET The CM927 thermostat is designed to provide automatic time and temperature control of heating or cooling systems in villas and apartments. It can be used as part of a system in conjunction with combiboilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone values and electric heating systems (<10A). In combination with other CM927 room units and HC60NG receivers it can be used to control multi-zone applications (up to 4 zones). The radio frequency controlled CM927 system pack consists of a room unit CMT927A and a relay box R6660D (HC60NG). No wiring to the room unit is required. The installer only needs to wire the relay box to the controlled device (e.g. boiler) and mount the room unit in a suitable location where RF communication is reliable. The CM927 uses reliable RF communication technology in the 868MHz band. The CM927 extra large LCD display, dynamic text display and controls layout are identical to the CM907 wired thermostat. The unit is ideal for consumers who want reliable and precise temperature control from a modern looking, simple to program and easy-to-use product. CM927 can be used to control a zoning system with up to 4 zones Maximum system efficiency and extended boiler life due to unique zoning system synchronisation Automatic Summer / Winter time change adjusts the time automatically to daylight saving time. Standard room units and receiver boxes are used for zoning applications algorithm When used with the table top stand the room unit can be positioned anywhere in the room where RF communication is reliable 24...230V 10A resistive, 3A inductive SPDT relay provides compatibility with most domestic central heating systems reducing the need to stock many different models. The HC60NG may be surface or wallbox mounted. Installer Set-Up Mode allows extra functions to be set at the discretion of the installer to match the consumer applications and needs: Optimisation Pump Exercise Upper / Lower Setpoint Limit Adjust Temperature offset Minimum ON time Cycle rate Heat / Cool Operation Proportional Band Width Fail-safe mode for communication loss 1

CONTROLS/DISPLAY LAYOUT Room Unit Layout: 1. Day & Date Display 2. Time Display 3. Dynamic Text Display (DTD) 4. Burner On Indicator 5. Battery Low Indicator 6. Temperature Display 7. Temperature Change Buttons 8. Information Enquiry Button 9. Slider Switch 10. Green OK Button 11. Program Buttons 12. Battery Cover 13. Battery Compartment 14. Holiday Button 15. Party Button 16. Day Off Button 17. Copy Day Button SPECIFICATIONS ELECTRICAL Room unit power supply Battery life Battery replacement Receiver power supply Switch type Output rating Wiring (receiver only) Wire access : 2 x 1.5 V IEC LR6 (AA) Alkaline cells : Minimum 2 years : Program retained in EEPROM : 230V AC +10% - 15%, 50Hz : SPDT potential free : 24-230 V AC, 10 A resistive, 3 A inductive 0.6 p.f. : Cable terminals for mains and relay wiring for max 2.5 mm 2 wire : from the rear (wall box mounting), right and bottom RF RF operation band : ISM (868.0-868.6) MHz, 1% duty cycle RF communication : 30 m in a residential building environment range RF communication technology : short, high rate transmissions to minimise air time and avoid collisions Blocking immunity : Receiver class 2 (ETSI EN300 220-1 version 1.3.1) RF binding method : Factory pre-bound with the room unit. ENVIRONMENTAL & STANDARDS Operating temperature Shipping & storage temperature Humidity IP class : 30 Meeting the following standards : 0 to 40 o C when relay load < 8 A : 0 to 30 o C when relay load > 8 A : -20 to 55 o C : Humidity range 10 to 90% rh, noncondensing : EN60730-1(Nov 2000), EN55014-1(1997), EN55014-2(2000), ETSI EN300 220-3 (2000), ETSI EN301 489-3(2000) TEMPERATURE CONTROL Sensing element : 100K (@ 25 o C ) NTC thermistor Control form : Fuzzy Logic Algorithm Minimum ON time Cycle rate Temperature control accuracy Fail-safe mode 10% of cycle time (min one minute), adjustable to 2 to 5 min (see installer set up) : Selectable by application (see installer set up) : + 0.5 K (nominal) @ 20 o C, 50% load 3K Δ/hour : Off or cycling depending on the CM927 system set-up TIME SETTING/PROGRAMMING Time display : 24 hour or 12 hour AM/PM format Time keeping : Typically better than 10 minutes per year accuracy Program : 7-day with 6 daily time and temperature level changes Time setting resolution Temperature setting range Room Temperature display range : Time of day - 1 minute Program 10 minute steps : Program : 5 to 35 o C in 0.5 o C steps Frost : 5 o C or equal to lower limit (5 o C to 16 o C). Frost protection does not work in cooling mode : From 0 o C to 50 o C 2

INSTALLER SET-UP To enter the installer set-up mode: a) Move the slider switch to the OFF position. b) Press and hold the INFO i button and the two program buttons < > together. c) The unit will display the first parameter of installer parameter group category 1 (from n.1 to n.19). d) Press the TEMP or buttons to change the factory setting. The display will flash indicating that a change has been made. e) Press the green OK button to confirm this change and the display will stop flashing. f) Press the + button to go to the next parameter. g) Press the program button > to go to category 2 in the Installer mode (from n.1 to n.14). h) To exit the installer mode, move the slider switch to the AUTO or MAN positions. Abbreviated Set-Up Description e.g. Cl = Clock Format CM927 CHRONOTHERM Factory Setting or New Choice Press TEMP or to change e.g. 12 = AM/PM Format 24 = 24hr Format Installer Set-up Number (Press + or - to change) e.g. 1 = Clock Format In Installer set-up we can: Brief Description of the Parameter Function. Set-up specific applications parameters Enable special features Configure system timing master for the zoning system Specific Applications Setting What do you need to change? Heating Gas Boilers (<30KW) Cycle/ Hour Minimum ON time (in minutes) Note : All parameters listed below belong to category 2 System Parameters (see Installer Parameters Table) 6 1 No changes required Oil Boiler 3 4 1. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. Air conditioning Thermal Actuator 12 1 Set Cycle/Hour to 12. Zone valve 6 1 No changes required. Heat Pump/ Air conditioner 1. Configure the thermostat to allow switching between heating and cooling modes (set parameter n.4:hc to 1) 2. Set the thermostat accordingly to the required mode of operation (heating or cooling) by pressing the TEMP or buttons together for 5 seconds. Modify the cooling program as required. 3 4 1. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. Fan coil 6 1 No changes required. 3

Special Features Description Setting Optimisation (Variable Start Time) The thermostat will adjust the start time in the morning/afternoon so the desired temperature is reached by the start of the program period. The system will restrict the start time to a max of 2 hours. To enable: Set parameter 8:OP (category 1) to 1. Heating or Cooling Operation Summer/Winter Auto time change Temperature Offset Upper/Lower Temperature Limit This product can be used for heating or cooling applications. If you select cooling mode the control algorithm and factory default program will be modified. You can independently modify the heating and cooling profile. This feature moves time automatically on the last Sunday of March and the last Sunday of October. The feature is factory enabled. If the thermostat is located in a particularly hot/cold location for reliable signal transmission reasons then the measured/displayed temperature can be adjusted by +/- 3 C. This is useful if the homeowner wants the reading to match another appliance temperature display. The normal upper temperature limit of 35 C can be reduced to 21 C to save the homeowner energy. The normal lower limit of 5 C can be increased up to 21 C to protect inhabitants from cold. To enable: Set parameter 4:HC (category 2) to 1. To enable: Set parameter 3:tC (category 1) to 1. Set parameter 12:tO (category 1) to the required offset value. Set parameter 6:uL (category 1) to the desired upper limit. Set parameter 7:LL (category 1) INSTALLER PARAMETER TABLES Parameter Installer Set- Up Number / Abbreviation (Press + or - keys to select) Factory Setting Category 1 Parameters Room Thermostat Settings Optional Setting Display Description Display Description AM-PM / 24hr Display 1:Cl 24 24 hr clock display 12 12 hr AM / PM clock display RESET Time / Temperature Program 2:rP 1 Time / Temperature profile set to factory default Changes to 0 when one of the time/temp profiles are changed 0 1 Time / Temperature are as programmed To restore the factory profile set to 1 Automatic Summer/Winter Time Change 3:tC 1 Automatic Summer/Winter Time Change Enabled 0 Automatic Summer/Winter Time Change Disabled LCD Backlighting 5:bL 1 Backlighting Enabled 0 Backlighting Disabled Upper Temperature Limit Lower Temperature Limit 6:uL 35 35 C Upper Temp. Limit 21 to 34 21 C to 34 C adjustment in 1 C steps 7:LL 5 5 C Lower Temp. Limit 6 to 21 6 C to 21 C adjustment in 1 C steps Optimisation 8:0P 0 Optimisation disabled 1 Optimisation enabled Temperature Offset 12:tO 0 No offset -3 to +3-3 C to +3 C adjustment in 0.1 C steps Proportional Band Width 13:Pb 1.5 1.5 C Proportional Band 1.6 to 3.0 1.6 C to 3.0 C adjustment in 0.1 C steps Reset Parameters to Factory Defaults 19:FS 1 All settings held are the factory defaults. 0 Settings are as modified above Changes to 0 when one of the parameter values are changed 1 To restore the factory profile set to 1 4

Parameter Installer Set- Up Number / Abbreviation (Press + or - keys to select) Factory Setting Optional Setting Category 2 Parameters System Settings (press the > button to access this category) Display Description Display Description Minimum boiler ON Time 1:Ot 1 1 minute minimum ON time 2 to 5 Selection of 2,3,4 or 5 minutes minimum ON time Cycle Rate 2:Cr 6 6 cycles per hour (cph) 3, 9 or12 Selection of 3,9 or 12 cph Heat / Cool Change 4:HC 0 Disabled 1 Enabled Pump Exercise 5:PE 0 Pump Exercise Disabled 1 Pump Exercise Enabled System Synchronisation 6:Sn 0 Standard operation of the Room Unit 1 Room unit configured as Synchroniser Loss of Communication Instruction 7:LC 0 Relay Off 1 Relay 20% on / 80% off The following parameters are for the control of other Wireless products such as Wireless Underfloor Heating controls and Wireless Radiator controls. For more information please contact sales. Room Temperature Sensor Use 8:Su 0 HC60 Control 1,2,3 or 4 1 - HR80/HM80 control with own/remote sensor (no temperature displayed) 2 - Hr80/HM80/HCE80 control with CM Sensor 3 - HC60 control and HR80/HM80/ HCE80 control with own/remote sensor 4 Hr80/HM80/HCE80 control with own/ remote sensor (temperature displayed) HR80 Window-Open Function 9:HO 0 Disabled 1 Enabled HR80 Local Override 10:HL 1 Enabled 0 Disabled Maximum Flow Setpoint 11:uF 55 55 C Maximum Flow Temp. 0 to 99 0 C to 99 C adjustments in 1 C steps Minimum Flow Setpoint 12:LF 15 15 C Minimum Flow Temp. 0 to 50 0 C to 50 C adjustments in 1 C steps Mixing Value Run Time 13:Ar 150 150 seconds 0 to 240 0 to 240 sec. adjustments in 1sec steps DIMENSIONS 5

INSTALLATION The CM927 is a radio frequency device and for the best performance should be installed in an open space. Leave at least 30cm distance from any metal objects including wall boxes and at least 1 metre from any other electrical equipment e.g. radio, TV, PC etc. Do not mount onto metal wall boxes. NOTE: It is recommended that the R6660D relay box is installed before commencing with the room unit installation (refer to the Installation Guide). R6660D Relay box CMT927A Room Unit a b WIRING The R6660D relay box is designed for fixed wiring only and must be installed in accordance with latest l.e.e. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 10 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles). IMPORTANT 1. The installer must be a trained service engineer 2. Disconnect the power supply before beginning installation 6

WIRING NOTE: All wiring must be in accordance with IEE regulations Caution: Observe ambient temperature and current limits (see the receiver box wiring label) ORDERING SPECIFICATION Description Model Logo Literature Availability Spec Sheet CMT927A1015 French & Dutch. CMT927A1023 French CMT927A1031 Spanish Feb 06 CMT927A1049 English (UK) CMT927A1056 Italian. CMT927A1064 HUN / GER / CZ TBC CMS927B1015 French & Dutch. CMS927B1023 French CMS927B1031 Spanish Feb 06 CMS927B1049 English (UK) CMS927B1056 Italian. CMS927B1064 HUN / GER / CZ TBC R6660D1017 French & Dutch. R6660D1025 French R6660D1033 Spanish R6660D1041 English (UK) R6660D1058 Italian. R6660D1009 Eng / Ger Control Systems Limited http://europe.hbc.honeywell.com Newhouse Industrial Estate Motherwell ML1 5SB United Kingdom 7