JD7105A Base Station Analyzer

Similar documents
G7104A Multimaster Base Station Tester

MultiMaster. Base Station Test Tools. Multi Purpose Base Station Tester. Introduction. Feature

JD723A/JD724B/JD726A Cable and Antenna Analyzers

Base Station Analyzer

JD7105B/JD745A Base Station Analyzer

COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS. JD747A RF Analyzer

GC723A / GC724B Cable and Antenna Analyzer

JD785A CellAdvisor Base Station Analyzer

JD746A/JD786A CellAdvisor RF Analyzer

CellAdvisor. JD745A Base Station Analyzer. Spectrum Analyzer (Standard)

JD785A CellAdvisor Base Station Analyzer

Advanced Test Equipment Rentals ATEC (2832)

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

JD745A/JD785A CellAdvisor Base Station Analyzer

CellAdvisor. JD785A Base Station Analyzer. Spectrum Analyzer (standard)

Advanced Test Equipment Rentals ATEC (2832)

PXI. TD-SCDMA Measurement Suite Data Sheet. The most important thing we build is trust. Total Average Power plus Midamble / Data Power

Spectrum Analyzers 2680 Series Features & benefits

TECHNICAL SPECIFICATION FOR RF (TEST &MEASUREMENT) DEVICE

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

Product Brochure. BTS Master MT8222A. A High Performance Handheld Base Station Analyzer

Spectrum Master MS2721B MS2723B MS2724B

Product Brochure. BTS Master MT8222A A High Performance Handheld Base Station Analyzer

Agilent CSA Spectrum Analyzer

DSA800. No.1 RIGOL TECHNOLOGIES, INC.

DSA700 Series Spectrum Analyzer

PXI WiMAX Measurement Suite Data Sheet

Cell Master MT8212A. Cable, Antenna and Base Station Analyzer

World s Most Trusted Family of Handheld RF and Microwave Analyzers

VIAVI CellAdvisor. Data Sheet. JD785A Base Station Analyzer. Spectrum Analyzer (standard)

VIAVI CellAdvisor. Data Sheet. JD786A RF Analyzer. Spectrum Analyzer (Standard)

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

SignalPROFILER E7062B 2 MHz ~ 6 GHz (CA) 9kHz ~ 6 GHz (SA)

IQgig-IF TM Technical Specifications

Cable and Antenna Analyzer. Site Master S331D/S332D. 25 MHz to 4000 MHz. The World s Leading Cable and Antenna System Analyzer.

PXI LTE FDD and LTE TDD Measurement Suites Data Sheet

DSA800 RIGOL TECHNOLOGIES, INC.

IQgig-RF TM Model B Technical Specifications

Specification RIGOL. 6 Specification

3250 Series Spectrum Analyzer

S900 Series SignalPROFILER

Agilent E4406A Vector Signal Analyzer

Handheld Spectrum Analyzers, 3.3 GHz & 8.5 GHz Models 2650A, 2652A, 2658A

PXI UMTS Uplink Measurement Suite Data Sheet

Measurement Guide and Programming Examples

CellAdvisor. JD745B/JD785B Base Station Analyzers

Agilent E6651A Mobile WiMAX Test Set

VIAVI CellAdvisor. Data Sheet. JD788A Signal Analyzer. Spectrum Analyzer (Standard)

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

3GPP2 Signal Analyzer

Agilent N9923A FieldFox RF Vector Network Analyzer 2 MHz to 4/6 GHz. Data Sheet

CellAdvisor. JD788B Signal Analyzer. Spectrum Analyzer (standard)

R3477. Ideal for mobile communication applications including base stations and handsets, from the development stage to production and installation

Agilent CSA Spectrum Analyzer

CellAdvisor. JD748B/JD788B Signal Analyzers

PXI. cdma2000/ev-do Measurement Suite Data Sheet. The most important thing we build is trust. cdma2000 RC1 to RC4 reverse link analysis

DSA800. No.2 RIGOL TECHNOLOGIES, INC. All-Digital IF Technology 9 khz GHz Frequency Range

CellAdvisor. JD748B Signal Analyzer Specifications. Spectrum Analyzer (Standard)

IQxel TM Next Generation Connectivity Test System

Spectrum and signal analyzers for every requirement an overview

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

IQxel-M8 TM Multi-DUT Connectivity Test System

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

R&S CMW100 Communications Manufacturing Test Set Specifications

IQgig-RF TM Technical Specifications

IQxel-M8W TM Multi-DUT Connectivity Test System

Handheld Spectrum Analyzer R&S FSH3

Handheld Spectrum Analyzer R&S FSH3

LitePoint IQxstream-M

Signal Generators for Anritsu RF and Microwave Handheld Instruments

R&S CMW100 Communications Manufacturing Test Set Specifications

Spectrum Analyzer. Distribution in the UK & Ireland

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Multi-function Site Passive Intermodulation Analyzer.

GA GHz. Digital Spectrum Analyzer

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

FREEDOM Communications System Analyzer R8000C DATA SHEET

FREEDOM Communications System Analyzer R8100 DATA SHEET

CellAdvisor. JD788B Signal Analyzer. Spectrum Analyzer (standard)

R&S FSH Handheld Spectrum Analyzer Where mobility counts

Overview. Key Facts. TSP Transmitter. TRANSCOM Cellular Network Measurement

Agilent E7495B Base Station Test Set

Handheld 3.3GHz Spectrum Analyzer

High Performance Handheld Spectrum Analyzer

GA GHz. Digital Spectrum Analyzer

CellAdvisor. JD745B Base Station Analyzer Specifications. Spectrum Analyzer (standard)

Quick Site Testing with the 8800SX

CellAdvisor. JD746B RF Analyzer Specifications. Spectrum Analyzer (standard)

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

FREEDOM Communications System Analyzer R8600 DATA SHEET

Multifunctional Microwave Analyzer

GSM Transmitter Modulation Quality Measurement Option

Product Overview. Main Characteristics. (9KHz~20GHz/26.5GHz/32GHz/44GHz)

Agilent 8902A Measuring Receiver

Willtek. Handheld Spectrum Analyzer

MA24104A. Inline High Power Sensor. True-RMS, 600 MHz to 4 GHz

Chapter 5 Specifications

Overview. Key Facts. SpecMini Handheld Spectrum Analyzer. TRANSCOM Cellular Network Measurement

Transcription:

COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS JD7105A Base Station Analyzer Introduction The JD7105A is a Base Station Analyzer for installation and maintenance of modern wireless communication systems. It combines the functionality of spectrum analysis, interference analysis, cable and antenna analysis, power meter, and modulation analysis, including: CDMA2000/EVDO GSM/GPRS/EDGE WCDMA/HSDPA TD-SCDMA WiMAX The JD7105A has been designed with a wide bandwidth analysis capability, ensuring the compatibility with future wideband technologies such as WiMAX. The JD7105A is the perfect field testing solution that combines portability, due to its lightweight design and battery extended operation, and performance, with its multifunction capability and high resolution display. In addition, the JD7105A provides an Auto-Measurement test capability which dramatically increases user s productivity. The JD7105 is the optimal solution for installation and maintenance of wireless communications systems. Features Multi-function Integration The Base Station Analyzer has integrated all the necessary functions to test and measure modern wireless communication systems. Its combined functionality includes spectrum analysis, interference analysis, cable and antenna analysis, power meter, channel scanner, E1/T1 analysis and modulation analysis for CDMA2000/EVDO, GSM/ GPRS/EDGE, WCDMA/HSDPA and TD-SCDMA.. Easy-to-use User Interface A common interface through its multiple functions provides the same menu structure that is easy to learn and use. It allows a quick configuration set for complicated radio systems, making a single button action to change the instrument configuration. Auto-Measurement and Error Logging The Auto-Measurement function performs configurable test scenarios and store the results to either its internal or external memory under specified measurement conditions and schedule. This function is particularly important for effective tracking, monitoring and isolating intermittent problems. Compact and Lightweight Design The Base Station Analyzer is compact and portable for users to perform outdoor maintenance jobs. The built-in high capacity Li-ion battery allows jobs at remote sites without being restricted by power cords. Easy to upgrade The JD7105A comes with software activated options, allowing easy upgrades, and enabling users to have new options available at their site. This benefit provides the convenience of configuring the Base Station Analyzer for today s needs and an easy upgrade path for future requirements. The JD7105A automatically verifies the latest firmware version and performs remote download & upgrade if necessary when it is connected to the network. The user can also easily perform firmware upgrades using a USB memory. WEBSITE: www.jdsu.com/test

2 The Complete Solution for BTS Maintenance Spectrum Analyzer 100 khz ~ 3 GHz (optional up to 3.7 GHz) TX Analyzer CDMA2000/EV-DO WCDMA/HSDPA GSM/GPRS/EDGE TD-SCDMA WiMAX Antenna/Cable Analyzer 25 MHz ~ 4 GHz Cable Loss DTF VSWR Gain/Loss Interference Analyzer 100 khz ~ 3 GHz (optional up to 3.7 GHz) Channel Scanner Up to 20 channels RF Power Meter Internal External Power Sensors E1/T1 Analyzer Transmission and Receiving 8.4 Color LCD High Resolution LCD Display FREQ/CHAN Sets Frequency and selects standard or custom frequency band AMPLITUDE Sets Scale, Reference Level, Attenuation POWER & LED Power ON/OFF Green LED: Power On status Red LED: External power ESC Cancels the inputs or moves to the previous menu SPEAKER Generates audio, if enabled, for alarms and key selections KNOB & UP/DOWN Moves marker positions or selects items on the table list SOFT KEYS Selects the options displayed in the screen DATA ENTRY KEYS Inputs numeric values TRACE Captures up to 6 traces Assign s saved trace to Trace CHSelects Active trace BW/AVG Sets Average, RBW, and RBW/VBW MARKER Supports six markers for each trace PEAK SEARCH Searches the highest peak of the Trace MEASURE Measures Channel Power, and Occupied Bandwidth SAVE Measurement result can be saved either as graphic files or data files MEASURE SETUP Measurement setup for Channel Power & Occupied Bandwidth LOAD Recalls saved traces to compare them with current or other saved traces SYSTEM Identifies and/or revise system information or upgrade firmware ENTER Finishes an entry, which is either a value or a test parameter MODE Selects Measurement modes - Spectrum Analyzer - Interference Analyzer - Tx Analyzer - Cable and Antenna Analyzer - E1/T1 Analyzer - Channel Scanner - Power Meter

3 Main Functions Spectrum Analyzer The Base Station Analyzer has a general purposed spectrum analyzer which is the most flexible test tool for RF analysis. Beyond this basic spectrum analysis functionality, a built in RF measurement application provides a one button RF measurements including: Channel Power Adjacent Channel Power Spectrum Emission Mask Occupied Bandwidth FM/AM Audio Demodulation Interference Analyzer The Base Station Analyzer has an interference analyzer function which is the most effective way to identify periodic or intermittent RF interference. A spectrogram display allows the user to capture spectrum activity while displaying frequency, power and time information. The signal tracking capability is particularly useful for observing signal strength at a single frequency over time with an audible indication.

4 Transmission Analyzer The modulation measurement suite of the Base Station Analyzer provides not only RF parametric analysis but also modulation parametric analysis of modern wireless communication systems. Built-in wireless standard test procedures allow users to test each of the following items with a single button action. CDMA2000 / EVDO Analyzer CDMA Channel Power CDMA Adjacent Channel Power CDMA Spectrum Emission Mask CDMA Code Domain Power Frequency Error Time Offset Wave Quality Auto PN Search Carrier Feed Through Codogram RCSI (Received Code Signal Indicator) EVDO Analyzer EVDO Channel Power EVDO Adjacent Channel Power EVDO Spectrum Emission Mask EVDO Power vs Time Slot Average Power Pilot Power MAC Power Traffic Power On/Off Ratio Idle Activity EVDO Code Domain Power Frequency Error Time Offset Auto PN Offset Search Rho (Pilot, MAC, Traffic) EVM (Pilot, Mac, Traffic)' Carrier Feed Through Codogram RCSI (Received Code Signal Indicator)

5 WCDMA/HSDPA Analyzer WCDMA Channel Power WCDMA Channel Power WCDMA Occupied BW WCDMA Spurious Emission Mask WCDMA Adjacent Channel Leakage Power Ratio (ACLR) WCDMA Multi-ACLR WCDMA Code Domain Power Frequency Error Error Vector Magnitude (EVM) Peak Code Domain Error (PCDE) Max Inactive Code Power Auto Scramble Search Carrier Feed Through Codogram RCSI (Received Code Signal Indicator) GSM/GPRS/EDGE Analyzer GSM Channel Power GSM Occupied BW GSM Spurious Emission Mask Power vs Time (Frame, Slot) Frequency Error Burst Power Average Burst Power IQ Origin Offset TSC Code BSIC Constellation Phase Error (rms) Phase Error (peak) Modulation Type EVM (rms) (EDGE) EVM (peak) (EDGE) EVM (95th) (EDGE)

6 TD-SCDMA Analyzer TD-SCDMA Channel Power TD-SCDMA Occupied BW TD-SCDMA Spurious Emission Mask TD-SCDMA Adjacent Channel Leakage Power Ration (ACLR) TD-SCDMA Multi-ACLR Power vs Time (Frame, Slot) On/Off Ratio DwPTS Power UpPTS Power Slot PAR DwPTS Code Code Domain Power & Error Frequency Error Time Offset PCDE EVM Peak EVM Constellation Rho RMS EVM Peak EVM PCDE IQ Offset Mobile WiMAX Analyzer Mobile Wimax Channel Power Mobile Wimax Occupied BW Mobile Wimax Spurious Emission Mask Power vs Time Channel Power Preamble Power Interval Power DL/DL Burst Power IQ Origin Offset Time Offset Constellation Frequency Error Relative Constellation Error (RCE) (rms) RCE (peak) EVM (rms) EVM (peak) Segment ID Cell ID Preamble Index Spectral Flatness EVM vs Subcarrier EVM vs Symbol Complementary Cumulative Distribution Function (CCDF)

7 Over The Air Measurements The Base Station Analyzer provides over the air measurements for a quick performance characterization of the base station. This function is especially useful in testing cell sites which are not easily accessible. Channel Scanner The Base Station Analyzer has the function of measuring multiple transmitted signals. The Channel Scanner can measure up to 20 channels in GSM, CDMA, or WCDMA networks. Using existing format-based or custom parameters, the user easily verify improper multi-channel power levels. GSM Channel Scanner The Base Station Analyzer has the function to display channel power and related information up to 128 GSM down link signals. This channel scanner can quickly identifies improper power levels that affect network performance; this can be done either over the air or directly connected to the cell site.

8 Cable and Antenna Analyzer The Base Station Analyzer can perform also the function of an antenna and cable analyzer that measures cable loss, distance to fault (DTF) voltage standing wave ratio (VSWR), Return Loss (RL) and insertion gain / loss. The antenna and cable analysis functionality can characterize active and passive devices such as cables, filters, amplifiers, antennas and multiplexers. In a one port measurement, users can measure feed-line cable loss, DTF location, and Antenna VSWR/RL. And with two ports measurements users can perform gain measurements, insertion loss and isolation; particularly useful for filers, amplifiers, Tower Mounted Amplifiers (TMA), RF path gain, and Antenna isolation. Power Meter The Base Station Analyzer can perform two power testing methodologies: Internal, for standard power measurements without the assistance of external power sensors. External, for high accuracy power measurements with the assistance of external power sensors. The internal power meter with no additional power sensors uses the spectrum analyzer functionality. It is a simple test methodology with reasonable accuracy. On the other hand, external power sensors perform power measurements more accurately. The Base station Analyzer can be equipped with a Terminating Power Sensor or with a Directional Power Sensor (through-line) which has the advantage to minimize service disruption and covers an ultra-wide power range. Power displays in either dbm or Watts. Upper/limit can be set during pass/fail measurements.

9 E1/T1 Analyzer The Base Station Analyzer provides a testing solution for E1/T1 transmission lines. Various test modes are available for the user, including: Mode: Term, Monitor, Bridge, Loop Frame: PCM30, PCM31, Unframed Code: AMI, HDB3, B8ZS TX Pattern: 1-8, 1-16, ALL0, ALL1, 0101, 2E20 Alarm, Error Count and Logging Auto-Measure The Auto-Measure function provides an easily set up for testing, including the programming of measurement schedules such as starting time, duration; intervals and measurement parameters. Based on the user defined conditions, the Base Station Analyzer performs the tests and automatically stores the results.

10 Specifications Standard Frequency accuracy ± 0.05 ppm internal Frequency aging ± 0.5 ppm / year Display 8.4 TFT LCD (800 x 600 mode) Frequency and Time Reference Even second TTL 10 MHz,13 MHz,15 MHz -10 ~ +10 dbm Spectrum Analyzer Input frequency range 100 khz ~ 3 GHz Maximum input level +30 dbm (1 W) Amplitude accuracy ± 1.0 db Resolution bandwidth 10 Hz ~ 3 MHz (1-3 sequence) Video bandwidth 1 Hz ~ 3 MHz (1-3 sequence) Dynamic range > 85 db Input attenuation 0 ~ 55 db (step 5 db) SSB phase noise -95 dbc @ 30 khz offset -105 dbc @100 khz offset DANL Typical -140 dbm@100 Hz RBW with preamp on Frequency Typical Max 10 MHz ~ 1 GHz -140 dbm -142 dbm 1 GHz ~ 2 GHz -138 dbm -140 dbm 2 GHz ~ 3 GHz -138 dbm -138 dbm Measurement range DANL ~ +30 dbm RF in VSWR <1.5 Power Meter 100 khz ~ 3 GHz Display ± 100 dbm (user settable) Measurement range -70 dbm ~ +30 dbm Offset range 0 ~ 60 db Accuracy - 40 dbm Power +30 dbm ± 1.0 db -70 dbm Power < - 40 dbm ± 1.5 db VSWR < 1.5 Maximum power +30 dbm(1 W) without external attenuator Cable and Antenna Analyzer Max input power (RF out) +25 dbm, ± 50 VDC 25 MHz ~ 4 GHz Frequency resolution 100 khz Data points 126, 251, 501, 1001 Measurement speed 1, 1.3, 2.5, 5 s for each data point One port power 0 dbm (nominal) Corrected directivity 40 db (typical) 1 port accuracy ± (0.8 + 20 log (1 + 10 -EP/20 ) ) db (typ.) EP = directivity-measured return loss Immunity to interference On frequency: +5 dbm On channel: +17 dbm VSWR Range 1 ~ 65 Resolution 0.01 Return loss Range Resolution 0 ~ 60 db 0.01 db DTF Vertical range VSWR: 1 ~ 65 Return loss: 0 ~ 60 db Vertical resolution 0.01 Distance 0 ~ 1250 m (4125 ft) Horizontal range 0 to (# of data points-1) x horizontal resolution Horizontal resolution (1.5 x 10 8 ) (Vp)/(delta) x 0.95 Vp: Cable's relative propagation velocity Delta[Hz] = stop freq start freq Cable Loss Range Resolution Gain/Loss Measurement Frequency resolution Output power level Dynamic range Channel Scanner Frequency accuracy Measurement range Channel power accuracy CDMA TX Analyzer 0 ~ 30 db 0.01 db 25 MHz ~ 3 GHz 100 khz -30 dbm or 0 dbm (nominal) -80 ~ +60 db 100 khz ~ 3 GHz ±10 Hz + ref freq/time accuracy -110 ~ +20 dbm ±1.0 db 410 MHz ~ 495 MHz, 805 MHz ~ 940 MHz 1750 MHz ~ 2170 MHz Frequency accuracy ±10 Hz + Ref Freq/Time Accuracy Waveform quality (ρ) ± 0.005 for 0.9 < ρ < 1 Pilot time alignment (Tau) ± 0.5 μs Code domain power ± 0.5 db relative power ± 1.5 db absolute power Pilot power ± 1.0dB Channel power ± 1.0dB

11 Specifications EVDO TX Analyzer Frequency accuracy 410 MHz ~ 495 MHz, 805 MHz ~ 940 MHz 1750 MHz ~ 2170 MHz ±10 Hz + Ref freq/time accuracy Waveform quality (ρ) ±0.005 for 0.9 < ρ < 1 Pilot time alignment (Tau) ± 0.5 μs Code domain power ± 0.5 db relative power ± 1.5 db absolute power Pilot power ± 1.0 db Channel power ± 1.0 db WCDMA/HSDPA TX Analyzer 869 MHz ~ 894 MHz, 1710 MHz ~ 2170 MHz Frequency accuracy ±10 Hz + Ref Freq/Time Accuracy EVM accuracy ± 2.0% for 2% < EVM < 20% Residual EVM 3.0% typical Code domain power ± 0.5 % for code channel power > -27 db 16, 32, 64 DCPH (test mode 1) 16, 32 DCPH (test mode 2, 3) CPICH accuracy ± 1.0 dbm Channel power ± 0.7 db (typical) Occupied bandwidth ± 100 khz Residual ACLR < -58 db @5 MHz, < -60 db @ 10 MHz ACLR accuracy ± 0.7 db GSM / GPRS / EDGE TX Analyzer Frequency accuracy GSMK modulation quality (RMS phase) Residual error (GSMK) 450 MHz ~ 500 MHz, 820 MHz ~ 965 MHz 1750 MHz ~ 1995 MHz ± 10 Hz + ref freq/time accuracy ± 0.5 deg 0.5 deg 8PSK modulation quality EVM ± 1.5% Residual error (8PSK) 2.50% Burst power ± 1.0 db GSM Channel Scanner Frequency accuracy Measurement range Power accuracy TD-SCDMA TX Analyzer 450 MHz ~ 500 MHz, 820 MHz ~ 965 MHz 1705 MHz ~ 1995 MHz ± 10 Hz + Ref Freq/Time Accuracy -110 ~ +20 dbm ± 1.0 db 1880 ~ 1920 MHz, 2010 ~ 2025 MHz Frequency error ± 10 Hz + Ref Freq/Time Accuracy Residual EVM (rms) 2.0% typical for P-CCPCH slot & 1 channel, slot power > -50 dbm Time error (Tau) ± 0.2 µs Supported modulation QPSK/8PSK Spread factor Auto 1, 2, 4, 8, 16 Channel power (RRC) ± 1 db typical for +10 dbm to -40 dbm ± 1.5 db max. Wimax Analyzer Channel power Frequency error Residual EVM (rms) T1 Analyzer Error detect code Alarm detection Receive level 100 MHz ~ 3.7 GHz ± 0.1 db typical for + 20 dbm to -50 dbm (± 1.5 max) ± 40 Hz + Time base error 2.0% typical for +20 dbm to -50 dbm BPV, frame, CRC Red alarm, yellow alarm, AIS alarm +6 ~ -36 db DSX Electrical Interface Connectors RX/TX RJ48C (100 Ω) Output 0 db, -7.5 db and -15 db Line code AMI, B8ZS Impedance 100 Ω or 1000 Ω (bridge) Input Term/bridge/monitor 0 ~ -20 db Transmitter and Receiver Framing D4, ESF Channel formats Full T1 Test pattern 1-8, 1-16, ALL1, ALL0, 0101 3E-24, QRSS, 2E-23, 2E-15 2E-23 inverse, 2E-15 inverse Additional Functions Reference clock Received or internal Event log capability Internal memory or external USB Error insertion 1, 1E-3, 1E-4, 1E-5 Alarm insertion AIS, RAI Error/alarm count Bit RAI, AIS, BPV, BER Loopback modes Self, CSU, NIU, line, network RX level measurement Vp-p, dbdsx E1 Analyzer Electrical Interface Connectors RX/TX RJ48C (120 Ω) Output 0 db, -6 db (ITU-T Rec.G.703) Line code AMI, HDB3 Impedance Term, monitor 120 Ω, bridge > 1000 Ω Input Term/bridge/monitor 0 ~ -20 db

12 Specifications Transmitter and Receiver Framing PCM-30, PCM-30 with CRC PCM-31, PCM-31 with CRC Full T1 Channel formats Test pattern 1-4, 1-8, ALL1, ALL0, 0101 Additional Functions Reference clock Received or internal Event log capability Internal memory or external USB Error insertion 1, 1E-3, 1E-4, 1E-5 Error rate count CRC, frame, code, bit High Accuracy Power Meter (Requires optional directional/terminating Power Sensor) Display range -80 ~ +120 dbm Offset range 0 ~ 60 db Resolution 0.01 db or 0.1x W Directional Power Sensors (optional) JD731A Sensor type Power range Average and peak 300 ~ 3800 MHz Average: 0.15 ~ 150 W (21.76 ~ 51.76 dbm) Peak: 4 ~ 400 W (36.02 ~ 56.02 dbm) Measurement uncertainty ± 4% of reading + 0.05 W 1, 2 Input return loss 2500 MHz, 27 db min >2500 MHz, 25 db Directivity 27 db min Insertion loss <1 GHz, <0.05 db 1 ~ 2 GHz, <0.1 db 2 ~ 3.8 GHz, <0.13 db Connector type N-female on both ends JD733A Sensor type Power range Average and peak 150 ~ 3500 MHz Average: 0.25 ~ 20 W (24 ~ 43 dbm) Peak: 0.25 ~ 20 W (24 ~ 43 dbm) Measurement uncertainty ± 4% of reading + 0.05 W 1, 2 Input return loss 2500 MHz, 27 db min >2500 MHz, 25 db Directivity 27 db min Insertion loss <1 GHz, <0.05 db 1 ~ 2 GHz, <0.1 db 2 ~ 3.5 GHz, <0.13 db Connector type N-female on both ends Terminating Power Sensors (optional) JD732A, JD734A, JD736A 20 MHz ~ 3800 MHz Power range -30 ~ +20 dbm (1 µw ~ 100 mw) Measurement uncertainty ± 7% of reading 1, 2 Connector type N-Male External Reference Clock 10, 13, 15 MHz external reference Input power Connector type Even second Input level Connector type Environmental Condition Operating temperature Storage temperature Calibration cycle Dimension -10 ~ +10 dbm SMA TTL compatible SMA -5 C ~ 50 C (23 F ~ 122 F) -20 C~ 70 C (-4 F ~ 158 F) 1 year Weight 5.6 kg (12.1 lbs) (including battery) Size (W x H x D) 315 x 245 x 95 mm (12.4" x 9.6" x 3.7") General Interface ports Serial 1 Port USB 1.1 1 Port 10 Mbps LAN 1 Port GPS Antenna (SMA) 1 Port Built-in Speaker Battery (Lithium Ion) Nominal voltage Normal capacity Maximum charge voltage Battery running time Power Supply AC input Specifications and product description subject to change without notice 1 Specification is provided at a temperature 25 C + 10 C 2 CW condition 10.8 V 6840 ma 12.6 V 1.5 hours at full charge 100 ~ 240 V, 2.5 A, 50 ~ 60 Hz Sensor type Average (JD723A) Peak (JD734A) Average and Peak (JD736A)

Ordering Information Mainframe JD7105A Options Base Station Analyzer incl. Spectrum Analyzer and Power Meter JD7105A001 Frequency Extension up to 3.7 GHz JD7105A002 E1 Analyzer (Requires adapters G710050317, 50318 or 50319) JD7105A003 Gain/Loss Measurement (requires option 007) JD7105A004 GPS Receiver and Antenna JD7105A005 T1 Analyzer (requires adapters G710050317, 50318 or 50319) JD7105A006 Channel Scanner JD7105A007 Cable and Antenna Analyzer (recommend calibration kits JD72450509 or 50510) JD7105A008 Interference Analyzer (recommended antennas G700050351~5 and/or G700050361~3) JD7105A009 GSM Channel Scanner JD7105A010 CDMA2000 OTA (requires options JD7105A004 and JD7105A020) JD7105A011 WCDMA OTA (requires options JD7105A004 and JD7105A030) JD7105A012 GSM/GPRS/EDGE OTA (requires options JD7105A004, JD7105A040, and 041) JD7105A013 TD-SCDMA OTA (requires options JD7105A004 and JD7105A047) JD7105A020 CDMA Analyzer JD7105A021 EVDO Analyzer (requires option JD7105A020) JD7105A030 WCDMA Analyzer JD7105A031 HSDPA Analyzer (requires optionjd7105a 030) JD7105A040 GSM/GPRS Analyzer (recommended option JD7105A009) JD7105A041 EDGE Analyzer (requires option JD7105A040) JD7105A045 Mobile WiMAX analyzer (7MHz, 8.75MHz, 10MHz) JD7105A047 TD-SCDMA Analyzer (1) Required for interference and OTA measurement (option 008 and 010, 011, 012, 013) (2) Required for E1/T1 Analyzer (option 002 or 005) Standard Accessories Soft Carrying Case AC-DC Adapter Cross LAN Cable (1.5 m) 1GB USB Memory Lithium-ion battery Stylus Pen User s manual and application software CD 2 years warranty Optional Accessories JD72450509 Calibration kit 40 db, 4 GHz, 50 Ω, N(m) Type JD72450510 Calibration kit 40dB, 4 GHz, 50 Ω DIN(m) Type G700050351 400 ~ 450 MHz Omni RF Antenna 1 G700050352 450 ~ 500 MHz Omni RF Antenna 1 G700050353 806 ~ 894 MHz Omni RF Antenna 1 G700050354 870 ~ 960 MHz Omni RF Antenna 1 G700050355 1710 ~ 2170 MHz Omni RF Antenna 1 G700050361 806 ~ 866 MHz Yaggi RF Antenna 1 G700050362 824 ~ 894 MHz Yaggi RF Antenna 1 G700050363 1750 ~ 2390 MHz Yaggi RF Antenna 1 G710050317 RJ45 to Y Bantam Cable 2 G710050318 RJ45 to Y BNC Cable 2 G710050319 RJ45 to 4 Alligator Clips 2 G710050581 Attenuator 40 db, 100 W, DC to 4 GHz (unidirectional) G700050571 Adapter N(m) to DIN(f), DC to 4 GHz, 50 Ω G700050572 Adapter DIN(m) to DIN(m), DC to 4 GHz, 50 Ω G700050573 Adapter N(m) to SMA(f), DC to 18 GHz, 50 Ω G700050574 Adapter N(m) to BNC(f), DC to 1.5 GHz, 50 Ω G710550342 Hard Case G710550362 User's Printed Manual GC71056000 Warranty Extension of 1 year for Asia, North America GC71056001 Warranty Extension of 1 year for Latin America, EMEA 1 Needs for Interference and OTA Measurement ( Option JD7105A008 and JD7105A010,011,012,013) 2 Needs for E1/T1 Analyzer ( Option JD7105A002 or JD7105A005) High Accuracy Power Sensors JD731A JD733A JD732A JD734A JD736A Directional Power Sensor (300 ~ 3800 MHz, Average Power 0.15 ~ 150 W, Peak Power 4 ~ 400 W) Directional Power Sensor (150 ~ 3500 MHz Average/ Peak 0.25 ~ 20 W) Terminating Average Power Sensor (20 ~ 3800 MHz, -30 ~ +20 dbm) Terminating Peak Power Sensor (20 ~ 3800 MHz, -30 ~ +20 dbm) Terminating Dual Mode (Average/Peak) Power Sensor (20 ~ 3800 MHz, -30 ~ +20 dbm) Test & Measurement Regional Sales NORTH AMERICA TEL: +1 866 228 3762 FAX: +1 301 353 9216 LATIN AMERICA TEL: +1 954 688-5660 FAX: +1 954 3454668 ASIA PACIFIC TEL: +852 2892 0990 FAX: +852 2892 0770 EMEA TEL: +49 7121 86 2222 FAX: +49 7121 86 1222 www.jdsu.com/test Product specifications and descriptions in this document subject to change without notice. 2009 JDS Uniphase Corporation 30149230 007 1009 JD7105ABS.DS.CPO.TM.AE