It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P TRMS series. Isolation Amplifiers.

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

5 years! Modular Housings. VariTrans P Warranty

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

5 years! Modular Housings. IsoAmp PWR A Warranty

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

VariTrans P V. Safe and Sound.

IsoAmp 3000/4000. The Advantages The dynamic range extends into the negative, allowing for strictly linear transmission

IsoAmp 11000/ The Universal Isolation Amplifier.

IsoAmp 11000/ Universal isolation amplifiers for ±20 mv to ±10 V or ±20 ma input signals.

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Coupling Relays and Converters

Loop-Powered Isolators for Standard Signals

Maconic Shunt Resistors

GAMMA 20 DIGITAL MULTIMETER

The Art of Measuring. Interface Technology Product Overview. ProLine

User and Safety Manual ProLine P224xx P1

Temperature Transmitter itemp RTD DIN rail TMT 127

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Type CP-S, CP-C & CP-A Switch mode

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

METRAClip87 and 88 Clamp Multimeters

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Analog signal converters CC range

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Temperature Transmitters - DIN Rail Mounted

Technical Information Barrier RB223

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

CONTA-ELECTRONICS. Converter Units

Switching power supplies CP range, Linear power supplies CP-L range. Content

IB IL AI 2/SF. Function. INTERBUS Inline Terminal With Two Analog Input Channels. Data Sheet 5564A

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Signal converters Index

Analog signal converters CC-E I/I

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

High Performance Current Transducer ITL 900-T = A

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MINI-PS AC/24DC/1.3

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature Transmitters - Head Mounted

AC/DC current clamps (1/2) E N series

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SINEAX TI 807 Passive DC signal isolator

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

For non-electrical quantities

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

GAMMA 12 DIGITAL MULTIMETER

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Transducer for Measurement Bridges SCM90, SIGS15

Temperature transmitter itemp RTD DIN rail TMT 127

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Analog Digital Multimeter with Insulation Resistance Measurement

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

High precision measurement system for current and voltage IHC-A/B-RM01/03

METRAClip85 and 86 Clamp Multimeters

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

SINEAX U 553 Transducer for AC Voltage

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

MINI-PS AC/2X15DC/1

Custom "Compact" range with display CD20 Custom Part number

CP-E range Benefits and advantages

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

Power supply CP-D 24/4.2 Primary switch mode power supply

DS10000ULFS-10V/10kA

CP-T range Product group picture

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Product Guide. Transducers

Programmable AC Current Transducer MT418

Solid-state Timer H3DE

Electronic relays. Monitoring. Monitoring

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

48 Series - Relay interface modules A. Features

Power supply CP-E 24/2.5

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Power supply CP-E 24/20.0

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

Transcription:

Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings VariTrans P 41000 D1 TRMS VariTrans P 41000 TRMS AC/DC High-Voltage Transmitters With True RMS, AC Input 60 mv~ to 10 V~ Universal AC/DC high-voltage transmitter for sinusoidal and non-sinusoidal AC input signals in the range from 60 mv to 10 V. True RMS value as standard-signal output for further processing in controllers or data acquisition systems. Calibrated selection of input and output., Product Line Devices AC input Output TRMS value Working voltage Test voltage Order no. VariTrans P 41000 TRMS Input and output switchable 60 mv... 10 V AC 1 to 16 ranges (low/high end of range 10) 0... 20 ma, 4... 20 ma, and/or 0... 10 V, 1 to 16 ranges 2.2 kv AC/DC 10 kv AC P 41000 D1 TRMS-nnnn VariTrans P 41100 TRMS Input and output with fixed settings 60 mv... 10 V AC 0... 20 ma, 4... 20 ma, or 0 10 V 3.6 kv AC/DC 15 kv AC P 41100 D1 TRMS-nnnn Specific Test Report included in shipment Power supply 20... 253 V AC/DC 6

, Specifications Input Data Input P 41000 D1 TRMS-nnnn 60 mv... 10 V AC; 1 to 16 customer-specific ranges, calibrated selection P 41100 D1 TRMS-nnnn 60 mv... 10 V AC; range fixed Rated frequency Frequency range Input resistance Input capacitance 50/60 Hz 40 1000 Hz (frequency 40 Hz on request) approx. 100 kohms Approx. 1 nf Overload Range 0.5 V limited by suppressor diode 6.8 V, permitted continuous current = 50 ma Range >0.5 V... 10 V limited by suppressor diode 68 V, permitted continuous current = 5 ma Output Data Output P 41000 D1 TRMS-nnnn 0 20 ma, 4... 20 ma and/or 0 10 V, switchable P 41100 D1 TRMS-nnnn 0 20 ma, 4... 20 ma or 0 10 V, fixed settings Displacement Up to 100 % as default Load With output current 12 V (600 ohms at 20 ma) With output voltage 10 ma (1000 ohms at 10 V) Residual ripple <10 mvrms Transmission Behavior Gain error Response T90 <0.3 % full scale Gain error for sinusoidal input signals (crest factor 2) in the frequency range 45 65 Hz <150 msec rising <300 msec falling Influential factors Frequency 40 1000 Hz <1 % meas. val. (typ. 0.5 %) (additional error) Crest factor 1 3 <0.5 % meas. val. (non-sinusoidal signals) Crest factor >3 5 <1 % meas. val. 7

VariTrans P 41000 D1 TRMS Specifications (continued) Common mode rejection ratio Temperature influence Input ranges 0.5 V CMRR Appr. 150 db (DC/AC: 50 Hz) T-CMRR Appr. 105 db (1000 V, tr = 1 μs) Other input ranges CMRR DC: approx. 150 db AC 50 HZ, approx. 120 db CMRR: Common-Mode Rejection Ratio = Differential voltage gain : Common-mode voltage gain T-CMRR: Transient Common-Mode Rejection = Differential DC gain : Common-mode transient peak value gain <50 ppm/k full scale Reference temperature for TC specifications = 23 C, average TC is specified Power Supply Power supply 20... 253 V AC/DC, AC 48... 62 Hz, approx. 2 VA; DC approx. 1.2 W Isolation Galvanic isolation 3-port isolation between input, output, and power supply Test voltage Calibrated switching 10 kv AC input against output and power supply Working voltage (basic insulation) to EN 61010-1 Rated isolation voltage to EN 50124-1 All models Calibrated switching Calibrated switching 15 kv AC input against output and power supply 4 kv AC output against power supply Up to 2200 V AC/DC across input, output, and power supply (fast transients: 13.5 kv) Up to 3600 V AC/DC across input, output, and power supply (fast transients: 20 kv) Up to 2200 V AC/DC across input, output, and power supply Up to 3600 V AC/DC across input, output, and power supply 8

Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Specifications (continued) Protection against electric shock Calibrated switching Safe Isolation to EN 61140 by reinforced insulation according to EN 61010-1. Working voltages with overvoltage category III and pollution degree 2: - Up to 1100 V AC/DC across input, output, and power supply - Up to 300 V AC/DC across output and power supply Safe Isolation to EN 61140 by reinforced insulation according to EN 61010-1. Working voltages with overvoltage category III and pollution degree 2: - Up to 1800 V AC/DC across input, output, and power supply - Up to 300 V AC/DC across output and power supply For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. Standards and Approvals EMC Product family standard EN 61326 Emitted interference Class B Immunity to interference Industry Slight deviations are possible while there is interference Other Data Ambient temperature Operation 10... +70 C Operation with restricted data (on request) 40... +85 C Transport and storage 40... +85 C Design Modular housing Housing width D1: 22.5 mm With screw terminals See dimension drawings for further measurements Ingress protection IP 40 enclosure, IP 20 terminals Fastening With snap-on mounting for 35 mm top-hat rail according to EN 60715 Weight Approx. 180 g 9

VariTrans P 41000 D1 TRMS, Application Example AC current measurement via shunt resistor 3600 V AC VariTrans P 41000 D1 TRMS 0... 150 mv AC 4... 20 ma DC Control M 20... 253 V AC/DC, Block Diagram C 1 nf Vin 1 nf Z* TRMS DC output V/I Z 13 V * Z Input 6.8 V 500 mv 68 V >500 mv Power supply 20... 253 V AC/DC 10

Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings, Dimension Drawings and Terminal Assignments 22.5 118.0 90.0 Snap-on mounting for 35 mm top hat rail EN 50 022 Please note: All dimensions in mm. Terminal Assignments: 5 Input AC voltage 60 mv... 10 V AC 7 Input 0 11 AC/DC power supply 12 AC/DC power supply 13 DC output current/voltage + 14 DC output voltage + 15 DC output voltage 16 DC output voltage M 3.5 connecting screws with self-releasing terminal housing conductor cross-section max. 1 x 4 mm solid or 1 x 2.5 mm stranded with sleeve, min. 1 x 0.5 mm solid or stranded with sleeve For switchable devices and voltage output, place jumper across terminals 13 and 14 11