Grounding Effect on Common Mode Interference of Coal Mine Inverter

Similar documents
Determination of EMI of PWM fed Three Phase Induction Motor. Ankur Srivastava

Modeling of Conduction EMI Noise and Technology for Noise Reduction

Mr. DILIP J. Final Year Mtech Student Dept of EEE The Oxford College of Engineering, Bangalore

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

SIMULATION of EMC PERFORMANCE of GRID CONNECTED PV INVERTERS

Simulation and Comparision of Back To Back System using Bidirectional Isolated DC-DC Converter with Active Energy Storage

CHAPTER 4 MEASUREMENT OF NOISE SOURCE IMPEDANCE

MVDC Grounding and Common Mode Current Control

Methods for Reducing Emissions from Switching Power Circuits. A. McDowell, C. Zhu and T. Hubing

Power Electronics. Exercise: Circuit Feedback

Mitigation of Common mode Noise for PFC Boost Converter by Balancing Technique

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

ELECTROMAGNETIC interference (EMI) filters have

Common Mode Voltage Reduction in a Three Level Neutral Point Clamped Inverter Using Modified SVPWM

OUTLINE. Introduction. Introduction. Conducted Electromagnetic Interference in Smart Grids. Introduction. Introduction

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

Improving Passive Filter Compensation Performance With Active Techniques

Measurement and reduction of EMI radiated by a PWM inverter-fed AC motor drive system

External Drive Hardware

Research Paper ELECTROMAGNETIC INTERFERENCE REDUCTION IN CUK CONVERTER USING MODIFIED PWM TECHNIQUES

About the High-Frequency Interferences produced in Systems including PWM and AC Motors

Filter Considerations for the IBC

Design of EMI Filters for DC-DC converter

Differential-Mode Emissions

Research on Parallel Interleaved Inverters with Discontinuous Space-Vector Modulation *

Electromagnetic interference at the mains ports of an equipment

Parallel Resonance Effect on Conducted Cm Current in Ac/Dc Power Supply

QPI-AN1 GENERAL APPLICATION NOTE QPI FAMILY BUS SUPPLY QPI CONVERTER

Frequency Domain Prediction of Conducted EMI in Power Converters with. front-end Three-phase Diode-bridge

Employing Reliable Protection Methods for Automotive Electronics

Design & Implementation of a practical EMI filter for high frequencyhigh power dc-dc converter according to MIL-STD-461E

CHAPTER 2 EQUIVALENT CIRCUIT MODELING OF CONDUCTED EMI BASED ON NOISE SOURCES AND IMPEDANCES

Conventional Paper-II-2011 Part-1A

CHAPTER 1 INTRODUCTION

EMI Filters Demystified. By William R. Bill Limburg February 21, 2018 Phoenix Chapter, IEEE EMC Society

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Bearing Currents and Shaft Voltage Reduction in Dual-Inverter-Fed Open-End Winding Induction Motor With CMV PWM Methods Employing PID

Part Five. High-Power ac Drives

Bearing Currents and Shaft Voltage Reduction in Dual-Inverter-Fed Open-End Winding Induction Motor With CMV PWM Methods Employing PID

IN-CIRCUIT RF IMPEDANCE MEASUREMENT FOR EMI FILTER DESIGN IN SWITCHED MODE POWER SUPPLIES

Electromagnetic Compatibility

A Novel Passive Filter to Reduce PWM Inverters Adverse Effects in Electrical Machine System

Load Compensation at a Reduced DC Link Voltage by Using DSTATCOM with Non-Stiff Source

Design and Simulation of Passive Filter

REDUCED COMMON MODE NOISE AND LOWER ORDER HARMONIC IN PUSH PULL CONVERTER BY ACTIVE FILTER

THE HYBRID active/passive electromagnetic interference

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz

Indirect Current Control of LCL Based Shunt Active Power Filter

Mixed Mode EMI Noise Level Measurement in SMPS

Resonant Power Conversion

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Electromagnetic Compatibility of Power Converters

Transformer-less PWM High Power Medium Voltage Variable Speed Drive

PARASITIC CAPACITANCE CANCELLATION OF INTE- GRATED CM FILTER USING BI-DIRECTIONAL COU- PLING GROUND TECHNIQUE

SINGLE-STAGE HIGH-POWER-FACTOR SELF-OSCILLATING ELECTRONIC BALLAST FOR FLUORESCENT LAMPS WITH SOFT START

Systematic Power Line EMI Filter Design for SMPS

Mitigation of voltage sag by using AC-AC PWM converter Shalini Bajpai Jabalpur Engineering College, M.P., India

A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems

A Novel Measurement System for the Common-Mode- and Differential-Mode-Conducted Electromagnetic Interference

An Integrated Inverter Output Passive Sinewave Filter for Eliminating Both Common and Differential Mode PWM Motor Drive Problems

Space Vector Modulation Techniques for Common mode Voltage Elimination in the Threelevel Voltage Source Inverter

2. Current interruption transients

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

Principles for Controlling Harmonics

EMI Noise Prediction for Electronic Ballasts

Modeling and Simulation of STATCOM

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

CHAPTER-3 MEASUREMENT OF COMMON MODE VOLTAGE IN 2- LEVEL INVERTER FED INDUCTION MOTOR DRIVE

An Interleaved Flyback Inverter for Residential Photovoltaic Applications

Design of a Hybrid Active Filter for Harmonics Suppression in Industrial Facilities

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

Harmonic Filtering in Variable Speed Drives

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

Common and Differential Mode EMI Filters for Power Electronics

Grounding System Theory and Practice

Active damping of output LC filter resonance for vector controlled VSI- fed AC motor drive

Module 2 : Current and Voltage Transformers. Lecture 8 : Introduction to VT. Objectives. 8.1 Voltage Transformers 8.1.1Role of Tuning Reactor

Design and Simulation of New Efficient Bridgeless AC- DC CUK Rectifier for PFC Application

Chapter 1 Introduction

EMI Model of an AC/AC Power Converter

Designing buck chopper converter by sliding mode technique

DRIVEN ASYNCHRONOUS MOTORS

Study on Electromagnetic Interference of High-Speed Railway EMU

A SOLUTION TO BALANCE THE VOLTAGE OF DC-LINK CAPACITOR USING BOOST CONVERTER IN DIODE CLAMPED MULTILEVEL INVERTER

Application Note AN- 1094

Application of Random PWM Technique for Reducing EMI

CHAPTER 2 LITERATURE REVIEW

PC Krause and Associates, Inc.

Design of SVPWM Based Inverter for Mitigation of Harmonics in Power System

MINING EARTH LEAKAGE PROTECTION WITH VARIABLE SPEED DRIVES

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

The unified power quality conditioner: the integration of series and shunt-active filters

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Research on Technology of Electromagnetic Protection for the Generator Control System

Practical Testing Techniques For Modern Control Loops

CS101. Conducted Susceptibility CS101. CS101 Maximum Current. CS101 Limits. Basis For CS101 Limits. Comparison To MIL-STD Vdc or Less

Prediction of Conducted EMI in Power Converters Using Numerical Methods

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 11 Issue 1 NOVEMBER 2014.

Efficient HF Modeling and Model Parameterization of Induction Machines for Time and Frequency Domain Simulations

Computerized Conducted EMI Filter Design System Using LabVIEW and Its Application

Transcription:

202 International Conference on Computer Technology and Science (ICCTS202) IPCSIT vol. 47 (202) (202) IACSIT Press, Singapore Grounding Effect on Common Mode Interference of Coal Mine Inverter SUN Ji-ping, CHENG Qiang, 2, +, WANG Bao-bao and JIA Xu-fen State Key Lab of Coal Resources and Safety Mining, China University of Mining and Technology (Beijing), Beijing 0008 2 Department of Computer Science, Nanyang Normal University, Nanyang 4706, China Abstract. This paper put forward a new model to analyze the grounding effect on common mode interference of underground PWM inverter. Taking into account the grounding method,the author establishs a common mode equivalent circuit of underground inverter. After Comparison of calculation results by Matlab software simulation it can be conclude that ungrounded neutral of transformer could redue common mode current in PWM system, but not very effective, the most efficient way is to increase grounding impedance of inverter and motor. Keywords: Converter, Common mode current, Grounding impedance, PWM inverter, Coal mine. Introduction Neutral grounding method refers to neutral point grounding operation of star-connected generator and transformer in power system. Neutral grounding methods of power system can be divided into five modes:not grounded, grounded by resistance, grounded by reactance, grounded by coil and direct grounding. Neutral grounding used in China electric power system currently is: 220kV system directly grounding: 0kV system directly grounding; 5kV system grounded by coil; 0kV system not grounded,grounded by coil, grounded by resistance or reactance; 80/220V system directly grounding.while neutral grounding methods of power supply system adopted by China coal mine could be three: directly grounding, not grounded and grounded by arc suppression coil. According to "Coal Mine Safety Regulations" section 44 provides: "No neutral grounding of underground distribution transformer, neutral grounding transformer or generator is prohibited power supply directly to the underground."[] Therefore, power supply system of underground coal mine does not use neutral grounding method. From a grounding point of view, different neutral grounding method does not affect low frequency system, but for inverter system, these grounding method have different impacts on conducted interference, these issues will be discussed in this paper. 2. Frequency Converter Conducted Emi Propagation Path Figure shows EMI propagation path of PWM inverter system. PWM drive system generally include AC / DC rectifier and DC / AC inverter. Since both circuits contain non-linear device, in general there exist two EMI source in system: rectifier and inverter bridge interference source. input Adding a linear impedance stabilization network (LISN) has two purposes: First, provide power supply and a stable impedance of 50Ω for equipment under test (EUT); secondly, blocking power interference on the device under test,and the LISN can also be replaced by feed through capacitors. From view points of power and load, there are two major interference paths [2]: one is common mode and differential mode interference on LISN side; the other + Corresponding author. Tel.: +86-856825. E-mail address: chess2@26.com,chess2@sina.com

is common mode and differential mode interference on motor side, direction of interference propagation path shows as arrows in Figure. Fig. : PWM inverter system EMI propagation paths Motor drive systems often chose different grounding methods based on various requirements, such as compliance with safety standards, transient over-voltage limit to the ground, or interruption of program requirements etc.. Except for these, the impact of grounding configuration is aslo an important aspect of EMC performance.as mentioned above, noise voltage source and current source is subject to the impact of rectifier and inverter configuration. The following section focuses on general and idealized way of grounding configuration. Actually grounding method does not significantly change the interference source characteristics. Nevertheless, through changing high-frequency current flowing path ground configuration can indeed affect EMC performance.. Different Grounding Configurations As shown in Figure 2, the impedance between AC power neutral point and ground is denoted as Z NG. In addition, the impedance between inverter chassis and ground is noted as Z FG, and electrical resistance between motor frame and ground is defined as Z MG. Select a different impedance means a different grounding method. Fig. 2: Grounding method diagram In general switching function of inverter can be defined as s i (i = a, b, c, u, v, w), then the voltage between DC-link midpoint (point O in Figure 2) and rectifiers can be expressed as voa = ( sa ) V vob = ( sb) V voc = ( sc ) V Considering the symmetry of three-phase power, v ON can be expressed by () v + v + v v + v + v i sl + i sl + i sl s + s + s v 2 Here the first term means voltage on boost inductors with common mode current. The second is due to rectifier transistors switching on and off. ag bg cg Oa Ob Oc a a b b c c a b c ON = + = + ( ) V (2) dc

The inverter part of PWM converter can be expressed by the same method, v no can be represented as iuslu + ivslv + iwslw su + sv + sw v no = + ( ) Vdc () 2 So we can get a simplified high-frequency equivalent circuit of PWM inverter as shown in Figure, where Z NG represents impedance between AC power neutral point and ground, Z OG represents impedance between DC bus and ground, L u represents motor winding inductance, Z MG represents impedance between motor and ground. Fig. : Equivalent circuit of PWM inverter system It is discussed in [] all the grounding possibilities of low and medium voltage drive system. According to Z NG the grounding configurations can be divided into four methods: solidly grounding, low resistance grounding, high resistance grounding and ungrounded system. Due to its simplistic structure, solidly grounding method is commonly used. Ungrounded system does not become a standard on account of its relative uncertain capacitance between power lines and ground. Thus reference [4] suggested that the correct implementation of high resistance grounding system should be an industry regulation. In addition we have another grounding option of inserting a damping resistor Z MG between motor frame and ground [5]. Generally most motor chassis grounded solidly,grounding methods typically affects CM current flowing into ground. A simplified common-mode equivalent circuit shown in Figure 4 is to be discussed. Usually, it is necessary for measurement to insert LISN between power supply and equipment under test (EUT). In accordance with measurement standard requirements, LISN require solidly grounding. Consequently high-frequency EMI produced by EUT could be bypassed by LISN, thus Z NG has little effect on noise propagation path.so only Z FG and Z MG can play an important role on noise propagation paths. 4. Molding Results Fig. 4: Common mode equivalent circuit with ground parameters

80 80 60 60 40 40 Magnitude (dbμa) 20 0-20 -40 Magnitude (dbμa) 20 0-20 -40-60 -60-80 -80-00 0 0 4 0 5 0 6 0 7 Frequency (Hz) -00 0 0 4 0 5 0 6 0 7 Frequency (Hz) (a) Z NG,Z FG and Z MG all gounded or all equal to 200Ω (b) Either of Z NG, Z FG and Z MG equal to 200Ω Fig. 5: Common-mode current in different grounding system As can be seen in Figure 5(a), grounding impedance (cyan lines) can indeed reduce common mode current, the difference is nearly 20dB at high frequency range. We can see in Figure 5(b), Z NG (green lines) has the most obvious effect, Z FG (red lines) has relatively worse results, while Z NG (blue lines) reduce the worst. When Z NG, Z FG and Z MG are all connected with damping resistor, the system have minimal commonmode currents. Therefore, the ungrounded neutral point of transformer secondary coil, which is equivalent to Z NG =200Ω,is beneficial for reducing common mode interference in PWM system, but not very effective, the most efficient way is to increase impedance of Z FG and Z MG. Nevertheless, motor frame must be grounded sloidly due to safety reasons. Recent years some scholars proposed installing a damping resistance in converter frame, and the frame must be grounded. Attention must be paid to avoid connecting resistance between chassis and ground, because this connection will increase risk of body electric shock, which is strictly prohibited by National mandatory safety standards. 5. Conclusion This paper put forward a new model to analyze the grounding effect on conducted EMI of a typical PWM motor drive. Based on a real object of industrial products, proposed extracting method of parasitic parameters on propagation path, established common mode EMI circuit model, proposed approximation method of high-frequency interference model to ensure the accuracy of high frequency prediction, and made quantitative experiment of conducted interference at power side and load side of PWM drive motors. The research ideas and practical calculation methods could be reference for prediction of conducted EMI system. In case motor frame is grounded solidly, common-mode current can flow through motor windings to motor frame, and then effectively into ground plane. Add a damping resistance in Z MG is a useful method of inhibiting motor-side high-frequency current [6]. Even the PWM rectifier is replaced by a diode rectifier, adding resistance in Z FG is also very effective, the noise generated by voltage source vrec can be mainly attenuated by Z FG. While the balance of Z MG and Z FG value should be considered, because the choice of a large Z FG will reduce the frequency impact of capacitor C Y in inverter. 6. Acknowledgements This work is supported by the National Natural Science Foundation of China under Grant No. 5067409. The authors would very much like to thank colleagues of State Key Lab of Coal Resources and Safety Mining. 7. References [] Meng Jin,Ma Weiming etc. High Frequency Model of Conducted EMI for PWM Variable-speed Drive Systems. Proceedings of the CSEE, 2008, 5,p. 4 4. [2] Skibinski G,Kerkman R,Schlegel D. EMI Emissions of Modern PWM AC Drives.IEEE Industry Applications Magazine,999, 5(6):47 8.

[] H. Akagi and T. Doumoto. An approach to eliminating high-frequency shaft voltage and leakage current from an inverter-driven motor, IEEE Trans. Ind. Applicat., vol. 40, no. 4, 2004,7, p. 62 69. [4] Meng Jin,Ma Weiming. Power converter EMI analysis including IGBT nonlinear switching transient model.ieee Trans.on Industrial Electronics, 2006, 54(5):577 58. [5] H. Akagi, T. Doumoto. A passive EMI Filter for Preventing High-Frequency Leakage Current from Flowing through the Grounded Inverter Heat Sink of an Adjustable-Speed Motor Drive System. IEEE Transactions on Industry Applications, Vol. 4, No 5, 2005, 9, p. 25 22. [6] H. Akagi and S. Tamura, A passive EMI filter for eliminating both bearing current and ground leakage current from an inverter-driven motor, IEEE Trans. Power Electron., vol. 2, no. 5, 2006,9, p. 459 469.