SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

Similar documents
American Electrical Institute

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Wisconsin Contractors Institute Continuing Education

Article 250 Grounding & Bonding

CONTINUING EDUC ATION

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

2014 NEC Changes Part 1

Licensed Electricians Practical Assessment (LEP)

EPG. by Chris C. Kleronomos

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Licensed Electricians Practical Assessment (LEP)

Grounding and Bonding of Service Equipment

The Importance of the Neutral-Grounding Resistor. Presented by: Jeff Glenney, P.Eng. and Don Selkirk, E.I.T.

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

SECTION PANELBOARDS

RADIO AND TELEVISION SATELLITE EQUIPMENT

SECTION CABLE TRAYS

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Preface...x Chapter 1 Electrical Fundamentals

Grounding and Bonding

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Ground Fault Location. Turbo Sleuth. Instruction Manual

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

NEC 2014 Code Changes

Electrical Wiring: Commercial, Seventh Canadian Edition

Article 225: Outside Branch Circuits And Feeders

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

ECET 211 Electric Machines & Controls Lecture 3-1 (Part 1 of 2) Motor Transformers and Distribution Systems

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate.

Field Instruction. Induced voltages can occur in overhead lines, underground cables, or in switchyards.

Education & Training

6B.6 Substation Grounding

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

B. Manufacturers: Square-D, G.E. or Westinghosue.

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

FAQ ON EARTHING STANDARDS 16/08/2018

Status Date Prepared Reviewed Endorsed Approved

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

2017 NEC TABLE OF CONTENTS

Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition

Continued from Part 1 Rules 1 25.

Reference Number PDS 07 (RIC Standard: EP SP)

Grounding for Power Quality

GROUND TESTERS For all of your Ground Testing needs...

Safety Issues Caused by High Earth Resistance and Identifying Them Using Instruments

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

Thank you for your interest in the Electrical Technician program. Following is the application process:

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

PRACTICAL PROBLEMS WITH SUBSTATION EARTHING

Arc Flash Analysis Training

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

ET 40 - Electrician Theory Examination Marking Schedule

TABLE OF CONTENT

Boat Dock Exposure Voltage Mitigation

This section applies to the requirements for the performance of power system studies by both the Design Engineer and the Contractor.

FINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes

First Draft Language

Grounding Recommendations for On Site Power Systems

Electrical Measurement Safety. Sponsored By:

Need for grounding Codes and Standards for grounding Wind Turbine Generator grounding design Foundation + Horizontal Electrode grounding design

Reference Number PDS 04 (RIC Standard: EP SP)

ELECTRICAL EQUIPMENT. Inspection. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

6. Internal lightning protection

SECTION 5 TRANSFORMERS

VI 3 - i TABLE OF CONTENTS

Department of Labor and Industry Electrical Licensing

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

7. INSPECTION AND TEST PROCEDURES

University of Central Florida Main Campus. Electric. Service and Meter Installations Requirements. Issued January 26 th, 2017.

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

2394 EXAM PAPER. 1. State THREE circumstances that would require a periodic inspection and test to be carried out on an installation

Agenda. Earthing of Telecom Installations using Single Point Earthing. Reference Documents. How many earths? Earthing Issue...

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT OFFICE

ELPT 1429 RESIDENTIAL WIRING

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only*

A DUMMIES GUIDE TO GROUND FAULT PROTECTION

PROVINCE.OF BRITISH COLUMBIA. ORDER OF THE LIEUTENANfelOVERNOR IN COUNCIL

Earthing, HV Switching and Associated Operational Equipment. Approval: Chief Operating Officer

CHAPTER 29 ELECTRICIAN S MATE (EM) NAVPERS G CH-70

Tower Grounding Training For Telecommunications Networks

GENERAL INSPECTION AND MAINTENANCE PROCEDURE FOR FIXED HF ANTENNA SYSTEMS

high RESISTANCE GROUNDING SYSTEM the power to protect www. ElectricalPartManuals. com Instruction Manual C-102

Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services

TN, TT & IT Earthing Arrangements

Stake-less earth / ground testing

Section 3. Test Procedures

PME specialises in developing, implementing and maintaining solutions to the Mining industry.

HV Substation Earthing Design for Mines

Grounding Systems and Their Implementation By: Charles Atkinson Canadian Broadcasting Corporation Toronto, Canada

INTELLIMETER REGISTER

Transcription:

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: 16.10 Document Number: KUCSH0039 Rev: 4 16.10.1 INTRODUCTION 16.10.1.1 The intent of this standard is to ensure that continuity and resistance tests of grounding systems are conducted on a specific schedule in accordance with specified methods and procedures. 16.10.2 DEFINITIONS 16.10.2.1 Electrical grounding - connected to or in contact with earth, or connected to some extended conductive body that serves in place of earth, to provide a path for leakage and / or fault currents to prevent an objectionable potential above ground on non-current carrying metal parts. 16.10.2.2 Grounding Systems - typically include the following: o Equipment grounding conductors - the conductors used to connect the metal frames or enclosures of electrical equipment to the grounding electrode conductor. o Grounding electrode conductors - the conductors connecting the grounding electrode to the equipment grounding conductor. o Grounding electrodes - usually driven rods connected to each other by suitable means, buried metal, or other effective methods located at the source, to provide a low resistance earth connection. 16.10.3 REQUIREMENTS 16.10.3.1 EFFECTIVE GROUNDING - The path from circuits, equipment, structures, and conduit or enclosures to ground shall be permanent and continuous, have ample carrying capacity to safely conduct the currents liable to be imposed on it, and have impedance sufficiently low to limit the potential rise above ground and to cause the operation of overcurrent devices to isolate the circuit. o Grounding grids and driven rod electrodes shall have a resistance to ground not to exceed 25 ohms. Where the resistance is above 25 ohms, two or more electrodes connected in parallel shall be used. o The resistance of a motor frame to grounded building steel shall not exceed one (1) ohm. o Electrical equipment shall be grounded in accordance with all applicable federal and state regulations, National Electric Code Page 1 of 9 Kennecott Utah Copper. The standards on the KUC Intranet website are considered the standard in effect and supersede all other revisions.

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: 16.10 Document Number: KUCSH0039 Rev: 4 and National Electrical Safety Code requirements. 16.10.3.2 POWER LINES - All structures, hardware, shield wires, and polemounted transformers shall be grounded. 16.10.3.3 SUBSTATIONS - All exposed metal parts of switches, structures, transformers, fences, gates, buildings, switchboards, breakers, meters, relays, lightning arresters, and communication equipment shall be grounded. o All substations shall have a ground grid to which all equipment is bonded. Resistance of grid to earth shall not exceed 25 ohms. 16.10.3.4 FIXED EQUIPMENT Equipment that is fastened in place or connected by permanent wiring methods. Exposed non-currentcarrying metal parts of fixed electrical equipment including motors, generators, frames, and rails of electrically operated cranes, electrically driven machinery, etc. shall be grounded. 16.10.3.5 PORTABLE EQUIPMENT Equipment that is fed with portable cords or cables intended to be moved from one place to another. The non-current-carrying metal parts of portable and / or plugconnected equipment shall be grounded. o Portable electric-powered equipment such as conveyors, electric shovels, drills, etc. with associated portable substations, and switchgear shall be connected to a safety ground system. Trailing cables powering such equipment will have adequately sized ground conductors with continuously monitored ground continuity check equipment. o Portable tools and appliances protected by UL approved system of double insulation, or its equivalent, need not be grounded. Where such an approved system is used, the equipment shall be distinctively marked. o Extension cords used with portable electric tools and appliances shall be of three-wire type and shall be maintained in good condition. 16.10.3.6 TEMPORARY WIRING - All temporary wiring shall be effectively grounded in accordance with the National Electrical Code. 16.10.3.7 TESTING Operators / craftsmen shall conduct the following tests. (See attached procedure and recordkeeping forms) Page 2 of 9 Kennecott Utah Copper. The standards on the KUC Intranet website are considered the standard in effect and supersede all other revisions.

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: 16.10 Document Number: KUCSH0039 Rev: 4 o Equipment grounding conductors - continuity and resistance must be tested immediately after installation, repair, or modification, and annually if conductors are subjected to vibration, flexing, or corrosive environments. o Grounding electrode conductors - continuity and resistance must be tested immediately after installation, repair, or modification, and annually if conductors are subjected to vibration, flexing, or corrosive environments. o Grounding electrodes - resistance must be tested immediately after installation, repair, modification, and annually thereafter. 16.10.3.8 Conductors in fixed installations, such as rigid conduit, armored cable, raceways, cable trays, etc. that are not subjected to vibration, flexing, or corrosive environments may be examined annually by visual observation to check for damage in lieu of the annual resistance test. 16.10.3.9 Grounding conductors in trailing cables, power cables, and cords that supply power to tools and portable or mobile equipment must be tested. (See Exhibit 16.1.1 Portable Equipment) This requirement does not apply to double insulated tools or circuits protected by ground-fault-circuit interrupters (GFCI). 16.10.3.10 Testing of equipment grounding conductors and grounding electrode conductors is not required if a fail-safe ground wire monitor is used to continuously monitor the grounding circuit and which would cause the circuit protective devices to operate when the grounding conductor continuity is broken. 16.10.4 RECORDKEEPING 16.10.4.1 A record of the most recent continuity and resistance test or visual examination conducted must be kept and made available for internal and regulatory inspections. The records shall: o Identify the equipment and location tested o Identify the person conducting the tests o Identify the date of the test o Record meter reading to the nearest 0.1 ohm o Identify action taken to address readings over one (1) ohm o Record a re-test reading upon completion of repairs 16.10.4.2 Recordkeeping forms are provided as attachments to this standard. Page 3 of 9 Kennecott Utah Copper. The standards on the KUC Intranet website are considered the standard in effect and supersede all other revisions.

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: 16.10 Document Number: KUCSH0039 Rev: 4 REFERENCES: National Electric Code (NEC) National Electrical Safety Code MSHA 30 CFR Part 56 & 57.12028 Rio Tinto Safety Standard C2 Electrical Safety Rio Tinto Electrical Standards Guideline Document REVISION HISTORY: MOC# Description of Change Prepared By Date 12584 Scheduled review and update including adding a procedure for continuity and resistance testing recommended by the C2 Standards Committee. Also, updated format and Document number added. KUC Safety and Health Standards Committee 6/10 Page 4 of 9 Kennecott Utah Copper. The standards on the KUC Intranet website are considered the standard in effect and supersede all other revisions.

Exhibit 16.10.1 Procedure for Testing Continuity and Resistance of Grounding Systems Continuity and resistance of grounding systems shall be tested immediately after installation, repair, or modification; and annually thereafter. A record of the resistance measured during the most recent test shall be made available for inspection and records shall be kept on file in accordance with the KUC records retention policy. Fixed Plant Equipment Annual Inspection (A) Equipment Needed a. Digital or analog volt-ohmmeter b. Spool of copper wire of appropriate length with alligator clamps or equivalent suitable connectors at each end (B) Zero Meter Through Wire Roll a. Attach one end of wire to meter b. Attach opposite end of wire to other meter probe c. Measure resistance of wire d. Adjust meter reading to 0 or record reading to deduct from overall resistance readings (C) Visually Inspect Grounding System and Repair as Needed a. Check for obvious signs of corrosion b. Check for broken conduit or flex c. If external grounds are present, inspect for damage (D) Record Meter Reading at Motor a. Attach one end of wire roll to grounded building steel ensuring good contact b. String out sufficient wire to reach motor and attach to meter probe c. Place other meter probe on motor housing ensuring good contact d. Record meter reading to the nearest 0.1 ohm (deduct wire roll resistance if meter not zeroed ) e. If resistance is higher than one (1) ohm, identify and correct deficiency (E) Clamp on Ground meter a. A ground resistance tester may be used in lieu of the above method to measure the resistance of the grounding system Repair or Modification (A) Measure the Resistance of the equipment grounding conductor when disconnected a. Use method A-D above but connect one probe of meter directly to the grounding conductor instead of the motor case b. After the motor is connected and before energizing measure resistance of grounding system using A E above (Annual Inspection) (B) Whenever grounding connections are visible or exposed during routine maintenance or troubleshooting, the grounding connections must be visually inspected. Page 5 of 9 Kennecott Utah Copper. The standards on the KUC Intranet website are considered the standard in effect and supersede all other revisions.

Portable Equipment - If not connected to a ground monitoring system (A) Equipment Needed a. Digital or analog volt-ohmmeter b. Spool of copper wire of appropriate length with alligator clamps or equivalent connector at each end (B) Zero Meter Through Wire Roll a. Attach one end of wire to meter b. Attach opposite end of wire to other meter probe c. Adjust meter reading to 0 or record reading to deduct from overall resistance readings (C) Visually Inspect Grounding System a. Check for obvious signs of corrosion b. Inspect feeder cable and connections for damage (D) Record Meter Reading at Motor a. Attach one end of wire to the MCC ground feeding the power cable, ensuring good contact b. String out sufficient wire to reach motor and attach to meter probe c. Place other meter probe on motor housing ensuring good contact d. Record meter reading to the nearest 0.1 ohm (deduct wire roll resistance if meter not zeroed ) e. If resistance is higher than one ohm, identify and correct deficiency Grounding Electrode Conductor The continuity and resistance of the equipment grounding conductors shall be measured by an inductive device or resistance reading between the frame of the motor and grounded building steel with a resistance of less than one (1) ohm Grounding Electrode The resistance of the grounding electrode or grounding electrode conductor to the earth shall be measured either by reference to an established earth-grounded electrode or inductive device (clamp on ground meter) with a resistance of less than 25 ohms Building Steel to Grounding Electrode Conductor The conductors between the building steel and the ground grid shall be visually inspected and the resistance determined by either an inductive device or a resistance meter between the building steel and the grounding electrode. Exposed steel to grid conductors should be visually examined for the condition of bonds and wiring, and of these, a representative number should be measured. Inspection or Repair When electrical equipment such as switchboards, panelboards, control panels, meter socket enclosures and motor control centers cabinet are accessed for inspection or repair, a visual inspection of the equipment grounding conductors shall be conducted. Page 6 of 9 Kennecott Utah Copper. The standards on the KUC Intranet website are considered the standard in effect and supersede all other revisions.

Exhibit 16.10.2 (Designate Plant for Identification) CONTINUITY AND RESISTANCE GROUND SYSTEM LOG MODIFICATIONS AND / OR REPAIRS DATE ELECTRICIAN (S): SUPERVISOR: MODIFICATIONS LOCATION: REASON: DESCRIPTION: TEST READINGS: REPAIRS LOCATION: REASON: DESCRIPTION: TEST READINGS: NEW INSTALLATION LOCATION: REASON: DESCRIPTION: TEST READINGS: COMMENTS: Distribution: Maintenance Superintendent Plant Records Page 7 of 9 Kennecott Utah Copper. The standards on the KUC Intranet website are considered the standard in effect and supersede all other revisions.

Exhibit 16.10.3 EQUIPMENT GROUNDING CONTINUITY AND RESISTANCE ANNUAL TESTING PROGRAM PLANT: EQUIPMENT NUMBER LOCATION/DESCRIPTION MOTOR FRAME TO BUILDING STEEL (OHMS TO 1 DECIMAL) PERSON PERFORMING TESTS DATE COMMENTS Distribution: Maintenance Superintendent Plant Records Page 8 of 9 Kennecott Utah Copper. The standards on the KUC Intranet website are considered the standard in effect and supersede all other revisions.

Exhibit 16.10.4 ANNUAL GROUNDING SYSTEM INSPECTION RECORD USING VISUAL OR CONTINUITY / RESISTANCE READING METHODS PLANT: DESCRIPTION/ LOCATION METHOD: VISUAL OR OHM READING PERSON PERFORMING TESTS DATE COMMENTS Distribution: Maintenance Superintendent Plant Records Page 9 of 9 Kennecott Utah Copper. The standards on the KUC Intranet website are considered the standard in effect and supersede all other revisions.