Printed in Japan E318

Similar documents
Excellent Performance; Ease of Use


Design Your Performance

A COMPACT SYSTEM WITH ADVANCED PERFORMANCE

Discover the new Prestige and experience 3D/4D imaging beyond your imagination.

UGEO H60. Performance in Style. Features

Vivid S5. Cardiovascular ultrasound system. GE Healthcare. Davis Medical

DC-6. Diagnostic Ultrasound System

DC-6 Expert. Diagnostic Ultrasound System

GE Healthcare. Vivid S5. Cardiovascular ultrasound system

S S S2 Operation Manual

Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare

General Imaging Ultrasound in a Whole New Light. Introducing the

GE Healthcare LOGIQ P3. Staying ahead of the curve

Multipurpose Color Ultrasound System IMAGING SYSTEMS

Doppler in Obstetrics: book by K Nicolaides, G Rizzo, K Hecher. Chapter on Doppler ultrasound: principles and practice by Colin Deane

Multi-Access Biplane Lab

Quality Ultrasound Systems

EVIS EUS ENDOSCOPIC ULTRASOUND CENTER EU-ME2 Dedicated ultrasound processor with versatile functionality.

Quick Reference Guide

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

Endoscopic Ultrasonography System

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

Beyond Performance and Value

ENDOSCOPIC ULTRASOUND SYSTEMS

M 5. M5 Hand-carried Diagnostic Ultrasound System. Mindray. A practical, durable ultrasound tool for high-quality imaging where and when you need it.

SONOACE 6000C MT DIGITAL COLOR. Affordable PC-based Digital CFM Ultrasound System. Specifications.

Model: ESE-6 Portable Color Ultrasound System

SPECIFICATIONS for Diagnostic Ultrasound System

Ultrasound System Specifications

M5 Diagnostic Ultrasound System

Ultrasound System Specifications

4 Working With Scan Modes

Point-of-Care Ultrasound in a Whole New Light. Introducing the

Image Optimization: The Sonographer s Responsibility. Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT

Ultimate DR flexibility

KIZLON. Sentinel House,Harvest Crescent, Ancells Business Park, Fleet Hampshire GU51 2UZ, UK Website:

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

Personal Ultrasound The future of ultrasonic scanning is here, today right in your hands. It s portable and affordable giving you the power and

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

Resona 6 Premium Ultrasound System

Ultrasound System Specifications

: PT Philips Indonesia CERTIFICATE OF PRODUCTION SOLE AGENT/ DISTRIBUTOR : NA CERTIFICATE OF DISTRIBUTION (PAK)

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

Q5 VET. Compact, Affordable Color Doppler for VET

OTC18 OVERHEAD TUBE CRANE SYSTEM

The Script of ZST + Presentation. MIS Upstream Marketing Team [ 日期 ]

INNOVATION BY DESIGN. Toshiba A History of Leadership REMOTE CONTROL R/F SYSTEM

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

Photomultiplier Tube

Model: ESE-G50 Color Ultrasound System

Luminos RF Classic. Where value meets performance.

RAD. Experiences Using the RADspeed Pro EDGE Package. 1. Hospital Description. 2. Background of Adoption. Hirohito Tanaka

Ergo TM Imaging System

Maximum Performance, Minimum Space

Chapter 6: TVA MR and Cardiac Function

Introduction to Medical Engineering (Medical Imaging) Ultrasound Imaging. Ho Kyung Kim Pusan National University

Iterative Reconstruction in Image Space. Answers for life.

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

siemens.com/luminos-fusion Luminos Fusion The 2-in-1 system that fits your needs and fits your budget

FMT18 FLOOR MOUNTED SYSTEM

MR Advance Techniques. Flow Phenomena. Class II

Vascular. Development of Trinias Series unity edition Angiography Systems. 1. Introduction. 3. Three Concepts of "unity"

monitoring device ought to find wide clinical application. available, while section three describes the Doppler interface with the B-scan machine.

160-slice CT SCANNER / New Standard for the Future

Ultrasound & Artifacts

Maximizing clinical outcomes

Optimisation of Image Acquisition Bordeaux 16th November J.S. McGhie W.B. Vletter R. Frowijn No disclosures

Philips EasyDiagnost Eleva

Diagnostic Ultrasound System. Operation Note

DIAGNOSTIC SCANNER HS-1600V. Convex/Linear Ultrasonic System

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล

Introduction. Parametric Imaging. The Ultrasound Research Interface: A New Tool for Biomedical Investigations

Ultrasound Imaging Ultr Michael Dadd 2007

Performing ultrasound probe quality assurance assessments: A How-to Guide

C506-E064. Full digital system. Printed in Japan A-NS

Creating a more comfortable place to work.

Breast Ultrasound QA Phantom Recommended by Japan Association of Breast and Thyroid Sonology

Vivid 7 Pro Breakthrough 2008 Release

Key Physics and Doppler Principles

The Middle East Distributor for AMBISEA Technology Corp. Electro-Medical Product Line

ddraura Series Productivity meets versatility

JorVet. Hand-Held Doppler. Operating Manual. Jorgensen Laboratories, Inc. Loveland, Colorado 80538

Control and confidence all around. Philips EP cockpit people focused solutions for heart rhythm care

Ultrasound physical principles in today s technology

Full Digital Ultrasound System UF-870AG

Lesson 12: Doppler Principles. This lesson contains 50 slides plus 26 multiple-choice questions.

Cardiac MR. Dr John Ridgway. Leeds Teaching Hospitals NHS Trust, UK

2014 HTD-E with options

ENDOSCOPIC ULTRASOUND SYSTEMS

Principles of Ultrasound Imaging Image Optimization

Artifacts. Artifacts. Causes. Imaging assumptions. Common terms used to describe US images. Common terms used to describe US images

Introduction to Ultrasound Physics

CONSOLE ADVANCE The He art of Your FDR/ FCR System

OEC Brivo 785 Essential

A DIVISION OF FORENSIC TECHNOLOGY. UCM pia The Universal Comparison Macroscope for Forensic Investigations

Digital imaging à la carte

An Activity in Computed Tomography

Transcription:

Diagnostic Ultrasound System MODEL PROSOUND 6 The specifications, shape and color of this product are subject to change without notice. The standard components and optional items vary depending on the country. Printed in Japan 2012-03 E318 (D)

Revolutionary Performance; Ease of Use Unprecedented performance with a broad range of applications - the compact ProSound 6 is at your service. Our ProSound series has a well-established reputation in hospitals and medical facilities throughout the world. The exceptional performance of the higher-end ProSound systems is available in the ProSound 6, delivering outstanding image quality, versatility and ergonomics. Powerful Incorporation of technologies developed for our higher-end models of the ProSound series. High-definition, high quality imaging for a wide range of applications. Excellent image processing functions: Broadband Harmonics (BbH), Adaptive Image Processing (AIP), Spatial Compound Imaging (SCI). High blood flow definition: eflow A wide variety of analytical software including etracking and TDI Analysis. User Friendly The operation panel's height adjustment mechanism allows for easier operation and enhancement of examination efficiency. Large touch panel screen boosting visibility and easier operation. Optimized switch layout according to frequency of use. Compact Small main body size accomplished by integration of electronic circuits. Mobility, easy handling and portability assured by the light weight and compact size. 2 3

Incredible Imaging Technology Bringing About High Versatility Broadband Harmonics (BbH) Harmonic imaging by Broadband Harmonics technology delivers sensitivity and resolution comparable to those of fundamental imaging. In addition to reducing artifacts caused by side lobes and multiple echoes, imaging performance is enhanced over the entire image. Adaptive Image Processing (AIP) AIP clearly displays differences in tissues. It is able to display outlines of tissues more clearly by selectively emphasizing boundaries. It reduces speckle noise while maintaining the frame rate. Thyroid gland tumor eflow image of the liver, with impressive vessel representation Image uniformity enabling clear visualization of the digestive tract Spatial Compound Imaging (SCI) Spatial Compound Imaging is used to depict sidewall structures of tubular cavities (arteries, veins, plaques, thrombus, etc). It allows the ultrasound beam to be directed in multiple directions, superimposing the different images on top of each other, reducing noise patterns by image comparisons. Consequently, artifacts are eliminated or dramatically reduced. Extended Field of View offers panoramic understanding of the thyroid gland Trapezoidal imaging of a fibroadenoma and its surrounding tissues Gallstone Image Optimizer Image Optimizer allows the brightness of B-mode images to be instantly optimized. Images are displayed under the desired imaging conditions at the touch of a button, freeing the examiner from constant imaging adjustments during examination, resulting in more efficient examinations. High spatial and contrast resolution image of the testis B/W and eflow images of the kidney in one screen with Dual Dynamic Display eflow Spatial resolution is higher than the conventional blood flow display methods, while optimized filtering reduces blooming (a distortion of the image). The system clearly displays information on blood flow, from high speed flow in large vessels to low speed flow in fine peripheral vessels. Kidney Detailed delineation of the elbow joint Freehand 3D image of muscles and its surrounding tissues 4 5

Confident Observations and Measurements For Both Mother and Child Spatio-temporal Image Correlation (STIC) View the fetal heart in 3D from any angle. Or observe it in 2D, from any cross section. STIC collects images of the same time phase from the data of multiple heart beats to construct the heart's volume data. High precision is guaranteed; the ProSound 6 detects fetal heartbeats by analyzing time phase using M-mode waveform or Doppler spectrum pattern. Global understanding of the fetal heart using STIC Dynamic Slow-motion Display (DSD) Observe the fast moving fetal heart, by displaying a real-time image and its slow-motion image together on one screen. For example, while a real-time image of two cardiac cycles is displayed, its slow-motion image can be displayed in half speed, as one cardiac cycle. The fetal heart, valve leaflets, and regurgitation flows and other fast moving objects can be observed easily and in detail. Real-time Slow motion Capture movements of the fast moving fetal heart with DSD Real-time Free Angular M-mode (FAM) For easy and accurate analysis on the M-mode, whether the targeted heart is an adult's or a fetus's. With FAM, up to three cursors can be set at any position, at any angle. The M-mode images can also be reconstructed after the image is frozen, using the Cine Memory function. Detailed imaging of the fetus's face and fingers with Real-time 3D (4D) Multi-planar Reconstruction offering multiple views for further understanding of the uterus Cervical cancer, post-treatment Automated Nuchal Translucency (NT) Measurement M-mode imaging from any angle of the fetal heart, using FAM Automated NT Measurement will automatically detect and measure NT thickness by setting the region of interest (ROI) on fetal neck's mid-sagittal view. This easy, quick and efficient function enhances accurate detection of chromosomal abnormalities such as Down syndrome. Multi-slice Imaging for observation of multiple slices Ovarian cancer Past and present data can easily be displayed on one report screen Quick, easy, accurate analysis with Auto NT Measurement Courtesy of Dr. Marc Althuser, France 6 7

Specialized for Diverse Applications Cardiovascular ProSound 6 offers a full complement of various analyzing software. Dual Dynamic Display (D.D.D.), Free Angular M-mode (FAM), and Doppler Auto Trace make daily examinations more comfortable. Software such as Asynchrony Study, Tissue Doppler Imaging (TDI), Strain, etracking provide more detailed, quantitative evaluation. The ProSound 6 is ready for the fundamentals and more. Protocol Assistant Smooth, confident examinations are available with the Protocol Assistant. Procedures of examinations can be pre-registered in the protocol: Automated IMT Measurement Early prognosis of cardiovascular events such as stroke or myocardial infarction is possible with Automated IMT Measurement. By simply setting the ROI on a long-axis view of the vessel, the max and mean IMTs are calculated. Parts to be examined, with body marks and annotations. Necessary measurements The registered protocols are displayed on the touch panel, enabling the sonographer to check the progress of examination at any time. Mis-recordings of images are avoided by checkmarks on the acquired/recorded sections and warning messages when the exams are being interrupted. etracking (Echo Tracking) Changes in vessel diameter are measured automatically and in real time with the analyzing function using etracking. With the precision of up to 0.01 mm, the tracking gate follows the vessel wall movement caused by pulsation. The ProSound 6 Probe Lineup ProSound 6 offers a wide variety of probes in various frequencies, suitable for a wide range of applications. Clear imaging. Well-considered shapes and sizes. Light weight. These probes are designed not only for stable, accurate and detailed imaging but also usability and comfort for both the sonographer and patient. etracking report screen Abdominal, UST-9123 OB/Gyn, ASU-1010 Endovaginal Gynecological, UST-9124 LV long axis view Tricuspid regurgitation Accurate depiction of IMT and plaque of both near and far walls Cardiac, UST-5299 Cardiac, TEE, UST-5293S-5 Peripheral vascular, Small parts, UST-5413 Intraoperative, UST-579T-7.5 Intraoperative, UST-533 Intraoperative, UST-9133 Stress echo Detailed analysis of velocity and time enables evaluation of the systolic and diastolic functions. Reliable data acquired by the high-accuracy Doppler Auto Trace Note: The compatible probes vary depending on the system version. Some probes require optional unit for connection. 8 9

Simple Design for Enhanced Utility The ergonomic panel design greatly reduces examination time The system is both versatile and easy to use as frequently used functions can be assigned to the controls on the touch panel and operation panel. 10.4-inch Touch Panel This small body has a surprisingly large touch panel,which greatly enhances work efficiency. The switches can even be assigned to suit the department or user,and troublesome procedures can be reduced for faster examinations. Keyboard The keyboard, which can be retracted under the operation panel, is ready for use with a light touch of a finger. The keys automatically illuminate during use, enabling efficient use in dark examination rooms. The User-friendly Horizontal Probe Holder The unique holder for endocavity probes enable two ways of securing; vertically and horizontally. Laying the endocavity probe down horizontally for its usability is another one of our friendly features. Ergonomic design and usability The high-quality LCD monitor can be swiveled horizontally and tilted vertically. The height of the operation panel can be adjusted to suit the position of the user during examination. The compact body (42cm wide) allows the system to fit easily into narrow bedside spaces. The rounded body and quietness of the system make the experience more comfortable for patients. Patient information and image data can be digitally stored in the built-in HDD, USB or external DVD recorders. We are committed to environmental protection. We at Hitachi Aloka Medical actively adopt various measures to facilitate segregation and recycling of waste products in the product design stage. We work hard to eliminate harmful substances. 10 11