Mass Flow and Density Transmitter

Similar documents
Mass and Volume Flow Transmitter

Micro Motion Model RFT9739

Micro Motion Model RFT9739 Flow and Density Transmitter

Series 1000 and 2000 Transmitters with MVD TM Technology

New! Micro Motion CNG050 Compressed Natural Gas Mass Flowmeter with MVD Technology. Product Data Sheet PS EU February 2001

Mass Flow and Density Transmitter with FOUNDATION fieldbus

Model RFT9709 Transmitter Instruction Manual

Micro Motion Series 1000 and 2000 Transmitters

Micro Motion Model 2400S Transmitters with MVD Technology

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Micro Motion Series 1000 and 2000 Transmitters

Micro Motion LF-Series Low Flow Sensor and Transmitter

Sarasota CM200 Sarasota HME900 Density Converter Electronics

PAD - Heavy Duty Differential Pressure Trasmitter

Micro Motion LF-Series Low Flow Flowmeter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

ATEX Installation Drawings and Instructions

Coriolis Massflowmeter

Micro Motion Series 1000 and Series 2000 Transmitters with MVD Technology

Micro Motion Model 1500 Transmitter with the Filling and Dosing Application

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

I/A Series Mass Flow and Density Meters Model CFT50 Digital Coriolis Mass Flow Transmitter with HART Communication Protocol

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Rosemount 148 Temperature Transmitter

Coriolis Massflowmeter

Kotron Sentinel Model 804 RF Level Transmitter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Kotron Sentinel Model 804 RF Level Transmitter

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009.

SMART TEMPERATURE TRANSMITTERS. smar

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

Process display RIA 261

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

IP26 Series Current to Pneumatic Converter

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

STT 3000 Smart Temperature Transmitter

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Electro-Magnetic Flowmeters COPA-XE

TIY Programmable, Isolated Thermocouple Transmitter combines

TMU. Coriolis Mass Flow Meter. for liquids and gas

Two-Wire Programmable Transmitter for:

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Magnetostrictive Level Transmitter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Rosemount 148 Temperature Transmitter

Magnetic Flowmeter Systems

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Rosemount 148 Temperature Transmitter

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

SATRON VB Pressure Transmitter

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount 148 Temperature Transmitter

Positioner with HART Communication Type 3780

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

ED701 General Industry Pressure Transmitter

Smart Pressure Transmitter

PRetrans Table of contents

Fisher 646 Electro-Pneumatic Transducers

Coriolis Mass Flow Meter Model TM

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Accutech FL10. Wireless float level field unit

B850 Boiler House Energy Monitor

Kotron Model 82 CE RF Level Transmitter

Applications: Power generation, Cogeneration, Stationary power Large engines

Magnetostrictive Level Transmitter

Fisher 646 Electro Pneumatic Transducer

B850 Boiler House Energy Monitor

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev NA July 2004.

Coriolis Massflowmeter

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Alphaline Temperature Transmitters

DigitalFlow XMT868i. Panametrics Liquid Flow Ultrasonic Transmitter. GE Measurement & Control. Applications. Features

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

0 2 1 â Ó. itemp HART TMT182. Technical Information

Installation guide 971 SmartRadar LTi

FDY PC-Programmable Frequency-to-DC Transmitter with Display

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

Installation guide 877 FDI Field Display & Interface

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

Micro Motion Fork Viscosity Meters

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

General Specifications

Rosemount 3101, 3102, and 3105

Series Smart Pressure Transmitter

Rosemount 702 Discrete Input Transmitter

Transcription:

RFT9739 Product Data Sheet PS-00257-EU October 1999 Mass Flow and Density Transmitter

RFT9739 transmitter The RFT9739 transmitter works with Micro Motion sensors to provide precision fluid measurement in a wide variety of fluid applications. The RFT9739 has modular, microprocessor-based electronics, incorporating ASIC digital technology with a choice of digital communication protocols. Combined with a Micro Motion sensor, the RFT9739 provides accurate mass flow, density, temperature, and volumetric measurements of process fluids. With a pressure transmitter properly installed in the flow loop, the transmitter also indicates pressure. The RFT9739 simultaneously transmits four output signals. Two independently configured analog outputs can each indicate flow rate, density, temperature, or pressure. A frequency/pulse output indicates flow rate or total. A control output indicates flow direction, a fault, or flowmeter zero in progress. The RFT9739 is available in field-mount and rackmount versions. The field-mount transmitter is housed in a IP65 (NEMA 4X) explosion-proof enclosure that provides easy access to the electronics module, and allows the transmitter and sensor to be installed in the same hazardous area. The rack-mount transmitter's compact housing is ideal for control room installations. The RFT9739 features user-selected Bell 202 or RS-485 serial standard for HART or Modbus communication protocols. For configuration in the field, use Micro Motion ProLink software, Fisher-Rosemount ä AMS software, or a Rosemount Model 275 HART Communicator. An integral liquid crystal display (LCD) is standard on the rack-mount model, optional with the field-mount version. Use the display to set communication parameters, read process variables, reset flow totalizers, and view diagnostic messages. Choose from a wide range of sensors to suit your application. The RFT9739 is compatible with Micro Motion ELITE sensors, the most accurate Coriolis meters available today. Or choose Micro Motion F-Series sensors, standard or high-pressure Model D sensors, Model DT hightemperature sensors, or Model DL sanitary sensors. Model RFT9739 transmitters support PlantWeb ä field-based architecture, a scalable way to use open and interoperable devices and systems to build process solutions of the future. 2 RFT9739 Transmitter

RFT9739 performance specifications Sensor model Flow accuracy* ELITE liquid ± 0,10% ± [(zero stability/flow rate) x 100]% of rate ± 0,50% ± [(zero stability/flow rate) x 100]% of rate F-Series liquid ± 0,20% ± [(zero stability/flow rate) x 100]% of rate ± 0,70% ± [(zero stability/flow rate) x 100]% of rate D (except DH38), DL and DT liquid ± 0,15% ± [(zero stability/flow rate) x 100]% of rate ± 0,65% ± [(zero stability/flow rate) x 100]% of rate DH38 liquid ± 0,15% ± [(zero stability/flow rate) x 100]% of rate ± 0,50% ± [(zero stability/flow rate) x 100]% of rate Sensor model Flow repeatability* ELITE liquid ± 0,05% ± [½(zero stability/flow rate) x 100]% of rate ± 0,25% ± [(zero stability/flow rate) x 100]% of rate F-Series liquid ± 0,10% ± [½(zero stability/flow rate) x 100]% of rate ± 0,35% ± [(zero stability/flow rate) x 100]% of rate D (except DH38), DL and DT liquid ± 0,05% ± [½(zero stability/flow rate) x 100]% of rate ± 0,30% ± [(zero stability/flow rate) x 100]% of rate DH38 liquid ± 0,05% ± [½(zero stability/flow rate) x 100]% of rate ± 0,25% ± [½(zero stability/flow rate) x 100]% of rate Density accuracy Density repeatability Sensor model kg/m 3 kg/m 3 ELITE (except high-pressure CMF010P) liquid ± 0,5 ± 0,2 ± 2,0 ± 1,0 ELITE high-pressure CMF010P liquid ± 2,0 ± 1,0 ± 8,0 ± 4,0 F-Series liquid only ± 2,0 ± 1,0 D6, D12, D25, D40, liquid only ± 2,0 ± 1,0 DH100, DH150 DH6, DH12, DH25, liquid only ± 4,0 ± 2,0 DH38 D65, DL65, DT65, liquid only ± 1,0 ± 0,5 D100, DT100, D150, DT150, DH300 DL100, DL200, liquid only ± 0,5 ± 0,2 D300, D600 Sensor model Temperature accuracy Temperature repeatability All models ± 1 C ± 0,5% of reading in C ± 0,2 C * Flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications are based on reference conditions of water at 20 to 25 C, and 1 to 2 bar unless otherwise noted. For measurement specifications, refer to product specifications for each sensor. For values of zero stability, refer to product specifications for each sensor. RFT9739 Transmitter 3

RFT9739 functional specifications Output signals Analog Two independently configured analog outputs, designated as primary and secondary, can represent mass or volumetric flow rate, density, temperature, event 1 or event 2. These outputs cannot be changed from active to passive. With a pressure transmitter, outputs can also provide indication for pressure. Internally powered, can be selected as 4-20 ma or 0-20 ma current outputs. Galvanically isolated to ± 50 VDC, 1000 ohm load limit. Out-of-range capability: 0-22 ma on 0-20 ma output; 3,8-20,5 ma on 4-20 ma output. Milliamp (ma) output rangeability Flow Maximum span determined by sensor specifications Range limit determined by sensor maximum rate Minimum recommended span (% of nominal flow range): ELITE sensors 2,5% F-Series sensors 10% D, DL, and DT sensors 10% D300 and D600 sensors 5% High-pressure (DH) sensors 20% typical Density Range limit: 0 to 5000 kg/m 3 Minimum span: 100 kg/m 3 Temperature Range limit: 240 to 450 C Minimum span: 20 C Frequency One frequency/pulse output can be configured to indicate mass flow rate, volumetric flow rate, mass total (inventory), or volume total (inventory), independent of analog outputs. Internally powered, 0-15 V square wave, unloaded; 2,2 kohm impedance at 15 V, galvanically isolated to ± 50 VDC. In open collector configuration: sinking capability, 0,1 amps in on condition (0 volt level), 30 VDC compliance in off condition. Signal can be scaled up to 10000 Hz. Out-of-range capability to 15000 Hz. Programmable pulse width for low frequencies. Dual-channel frequency (rack-mount transmitter only) Approved for custody transfer applications, a dual-channel frequency output, referred to as frequency A and frequency B. Phase shift between channels is 90 degrees. Output derived from the primary frequency, and represents the same process variable as the frequency output, but with half the frequency. All specifications match frequency/pulse output except: Signal can be scaled up to 5000 Hz; out-of-range capability to 7500 Hz. The output complies with VDE/VDI 2188. Optocoupler (rack-mount transmitter only) The optocoupler is an externally powered output. Signal voltage: low level 0-2 VDC, high level 16-30 VDC. Maximum signal current 0,01 amp. Maximum capacitive load 150 nf at 10 khz. Output is derived from the primary frequency, and represents the same process variable as the frequency/pulse output. The output complies with VDE/VDI 2188. Control One control output can represent flow direction, fault alarm, zero in progress, event 1 or event 2. Internally powered, digital level, 0 or 15 V, 2,2 kohm pull-up, galvanically isolated to ± 50 VDC. In open collector configuration: sinking capability, 0,1 amps in on condition (0 volt level), 30 VDC compliance in off condition. Digital Switch allows selection of Bell 202 and/or RS-485 serial standard. Bell 202 signal is superimposed on primary variable ma output, and available for host system interface. Frequency 1,2 and 2,2 khz, amplitude 0,8 V peak-to-peak, 1200 baud. Requires 250 to 1000 ohms load resistance. RS-485 signal is a ± 5 V square wave referenced to transmitter ground. Baud rates between 1200 baud and 38,4 kilobaud can be selected. 4 RFT9739 Transmitter

Additional outputs Sensor frequency For use with Micro Motion peripheral devices, 8 V peak-topeak at sensor natural frequency, referenced to sensor ground, 10 kohm output impedance. Sensor temperature For use with Micro Motion peripheral devices, 5 mv/ C, referenced to signal ground, 10 kohm output impedance. API gravity output API gravity references to 15 C. Uses correlation based on API equation 2540 for Generalized Petroleum Products. Accuracy of corrected density calculation relative to API-2540 from 0 to 300 F: Process fluid g/cc kg/m 3 API Diesel, heater, fuel oils ± 0,0005 ± 0,5 ± 0,2 Jet fuels, kerosenes, solvents ± 0,002 ± 2,0 ± 0,5 Crude oils, JP4 ± 0,004 ± 4,0 ± 1,0 Lube oils ± 0,01 ± 10 ± 2,0 Gasoline, naphthenes ± 0,02 ± 20 ± 5,0 Minimum 4-20 ma span: 10 API. Standard volume Indicates standard volume at 60 F or 15 C for Generalized Petroleum Products when API is selected as density unit of measure. Accuracy of standard volume measurements depends on accuracies of mass flow rate, density, temperature and temperature-corrected API calculation, and can be estimated using the root mean square method. Standard volume accuracy of ± 0,5% of rate is typically attainable for Generalized Petroleum Products such as fuel oils, jet fuels, and kerosenes. Pressure compensation Analog input can accept a signal from a pressure transmitter for pressure compensation of flow and density. Range, 0-25 ma. Can be used to power independent pressure or differential pressure transmitter. Voltage sourcing capability, 15 V. Input impedance, 100 ohms. Slug-flow limits Transmitter senses density outside limits. Flow output remains at last measured value, for a programmed time of 0-60 seconds, before defaulting to the level that represents zero flow. Damping Wide range of programmed filter time constants for damping on flow, density, and temperature. Additional damping may be applied to ma outputs. Fault indication Faults can be indicated by user-selected downscale (0 ma or 0-2 ma, 0 Hz) or upscale (22,2-24 ma, 15-19 khz) output levels. Control output can also be configured to indicate a fault condition at 0 V. Output testing Current source Transmitter can produce a specified current between 0 and 22 ma on 0-20 ma output, or between 2 and 22 ma on 4-20 ma output. Frequency source Transmitter can produce a specified frequency between 0,1 and 15000 Hz. Local display Optional for field-mount transmitter. Standard on rack-mount transmitter. Display is a 2-line, 16-character, alphanumeric liquid crystal display (LCD). Using the transmitter's scroll function, the user can view flow rate, density, temperature, mass and volume totals and inventory levels, and status messages on the LCD. A reset button allows the user to reset the transmitter's flow totalizers and communication parameters, as well as zero the flowmeter. Low-flow cutoff Flow values below the low-flow cutoff cause analog, frequency, and digital outputs to default to zero flow levels. Each ma output may be configured for an additional low-flow cutoff. RFT9739 Transmitter 5

RFT9739 functional specifications continued Power supply options Field-mount transmitter 85 to 250 VAC, 48 to 62 Hz, 10 watts typical, 15 watts maximum, fused with IEC 127-3 400mA/250V, time-lag, subminiature. All AC-powered RFT9739 transmitters comply with low-voltage directive 73/23/EEC per IEC 1010-1 with Amendment 2. 12 to 30 VDC, 7 watts typical, 14 watts maximum, fused with IEC 127-3 1,6A/125V, time-lag, subminiature. At startup, transmitter power source must provide a minimum of 1,6 amperes of short-term current at a minimum of 12 volts at the transmitter's power input terminals. Rack-mount transmitter 110/115 VAC ± 25%, 48 to 62 Hz, 10 watts typical, 15 watts maximum, fused with UL/CSA 250mA/250V, time-lag, 5x20mm 220/230 VAC ± 25%, 48 to 62 Hz, 10 watts typical, 15 watts maximum, fused with UL/CSA 250mA/250V, time-lag, 5x20mm All AC-powered RFT9739 transmitters comply with low-voltage directive 73/23/EEC per IEC 1010-1 with Amendment 2. Environmental limits Ambient temperature limits Field-mount transmitter Without display Operating 30 to 55 C Storage 40 to 80 C With display Operating 10 to 55 C Storage 20 to 70 C Rack-mount transmitter Operating 0 to 50 C Storage 20 to 70 C Humidity limits Meets SAMA PMC 31.1-1980 Vibration limits Field-mount transmitter Meets SAMA PMC 31.1-1980, Condition 2 Rack-mount transmitter Meets SAMA PMC 31.1-1980, Condition 1 12 to 30 VDC, 7 watts typical, 14 watts maximum, fused with UL/CSA 2A/125V, medium-lag, 5x20mm. At startup, transmitter power source must provide a minimum of 2 amperes of short-term current at a minimum of 12 volts at the transmitter's power input terminals. 6 RFT9739 Transmitter

Environmental effects EMI effect on sensor and transmitter Transmitters with enhanced EMI immunity meet the requirements of the EMC directive 89/336/EEC per EN 50081-1 (January 1992) for field-mount RFT9739, EN 50081-2 (January 1992) for rack-mount RFT9739, and EN 50082-2 (March 1995), when operated at nominal rated flow measurement range. Enhanced EMI immunity is required for transmitters installed in the European Community after 1 January 1996. For specific EMC effects within the EC, the Technical EMC file may be reviewed at Micro Motion Veenendaal. All RFT9739 transmitters meet the requirements of SAMA PMC 33.1 (October 1978), Class 1, A, B, C (0,6% span) at nominal flow rate. All RFT9739 transmitters meet the recommendations of ANSI/IEEE C62.41 (1991) for surge and EFT. To meet the above specifications, the transmitter must be installed with an approved Micro Motion sensor, and the sensor cable must be either doubly shielded with full contact glands, or installed in continuous, fully bonded, metallic conduit. The transmitter and sensor must be directly connected to a low-impedance (less than 1 ohm) earth ground. Transmitter outputs must be run in standard twisted-pair, shielded instrument wire. Ambient temperature effect on transmitter On milliamp outputs ± 0,005% of span/ C On temperature output ± 0,01 C/ C On milliamp input ± 0,01% of span/ C Hazardous area classifications Field-mount transmitter Without display UL and CSA Class I, Div. 1, Groups C and D. Class II, Div. 1, Groups E, F, and G explosion proof when installed with approved conduit seals. Otherwise, Class I, Div. 2, Groups A, B, C, and D. Provides nonincendive sensor outputs for use in Class I, Div. 2, Groups A, B, C, and D; or intrinsically safe sensor outputs for use in Class I, Div. 1, Groups C and D or Class II, Div. 1, Groups E, F, and G. CENELEC EEx d [ib] IIC T6 flameproof when installed with approved cable glands. Otherwise, [EEx ib] IIC. SAA Exd [ib] IIC T6 With display UL and CSA Class 1, Div. 2, Groups A, B, C, and D. Provides intrinsically safe sensor outputs for use in Class I, Div. 1, Groups C and D; nonincendive sensor outputs for use in Class I, Div. 2, Groups A, B, C, and D. CENELEC Safe area only. Intrinsically safe sensor outputs for [EEx ib] IIC. SAA Ex [ib] IIC IP66 UL Division 2 nonincendive parameters for all RFT9739 field-mount transmitters Analog output Frequency output Parameter (Terminals 17-18, 19-20) (Terminals 14-16) V OC 36,5 V 16 V I SC 22 ma 51 ma C a 0,135 µf 1,5 µf L a 100 mh 37 mh Rack-mount transmitter UL Non-hazardous locations. Provides nonincendive sensor outputs for use in Class I, Div. 2, Groups A, B, C, and D; or intrinsically safe sensor outputs for use in Class I, Div. 1, Groups C and D or Class II, Groups E, F, and G. CSA Non-hazardous locations. Connections to sensor are intrinsically safe for use in Class I, Div. 1, Groups C, D, and Class II, Groups E, F, and G. CENELEC Safe area only. Connections to sensor are intrinsically safe in [EEx ib] IIC areas. RFT9739 Transmitter 7

RFT9739 field-mount physical specifications Housing IP65 (NEMA4X ) epoxy polyester painted cast aluminum Cable gland entrances Three 3/4-14 NPT on transmitter base Electrical connections Screw terminal blocks for all signal wiring can be unplugged. Fixed screw terminals for power connections. Screw terminal on housing for chassis ground. Studs for intrinsic safety ground. Weight (without display) 5,7 kg Dimensions in mm 4X Æ 9 71 Minimum clearance for removal of cover: without display 292 with display 335 Optional display Optional display 213 232 115 233 185 3x 3/4-14 NPT conduit opening Æ 184 5 60 60 39 8 RFT9739 Transmitter

RFT9739 rack-mount physical specifications Housing 19-inch rack, European standard DIN 41494: 128 mm (3HE) high x 142 mm (28TE) wide x 231,9 mm deep. Electrical connections Two connectors per DIN 41612, type F. Choose either fast-on (wire-pin) solder connectors (standard) or Y-shaped screw-terminal connectors (optional). Sensor connectors and output connectors are not interchangeable. Weight 2,0 kg Dimensions in mm 127 25TE With Y-shaped screw terminals 281,9 With fast-on/solder terminals 255,6 DIN 41612 male connectors 3HE 128,4 122,4 111,1 OUTPUT SENSOR 28TE 18,7 212,3 13TE 141,7 4,7 234,6 66 RFT9739 Transmitter 9

RFT9739 field-mount model number matrix RFT9739 Transmitter Model RFT9739 transmitter Housing options E Field-mount, without display, IP65 (NEMA 4X), explosion-proof D Field-mount, with display, IP65 (NEMA 4X) Power-supply options 4 85-250 VAC 5 12-30 VDC S E Configuration Standard Enhanced EMI immunity (CE compliant) requires installation with Micro Motion cable type RFP or RFT installed in conduit, or type CBPS or CBPA installed with approved cable glands Approvals M Micro Motion standard (no approvals) U UL B CENELEC intrinsically safe sensor outputs F CENELEC intrinsically safe sensor outputs/flameproof transmitter not available with housing code D Glands Available with approvals codes M, C, and S Available with approvals code U only with housing code D A No fittings or glands Available with approvals code U only with housing code E J 1 x explosion-proof seal fitting K 3 x explosion-proof seal fitting Available with approvals code B (non-eexd) B 1 x gland, nickel-plated brass (7-12,5 mm) C 3 x gland, nickel-plated brass (7-12,5 mm) Available with approvals code F only with housing code E D 1 x gland, nickel-plated brass (8-12 mm/10,5-16 mm) E 1 x gland, SS (8-12 mm/10,5-16 mm) F 3 x gland, nickel-plated brass (8-12 mm/10,5-16 mm) G 3 x gland, SS (8-12 mm/10,5-16 mm) Example* RFT9739 E 4 E B C *Example: RFT9739 E 4 E B C = RFT9739 field-mount transmitter in IP65 (NEMA 4X) explosion-proof housing without display; configured for 85-250 VAC power supply; enhanced EMI immunity (CE-compliant); CENELEC-compliant intrinsically safe sensor outputs; with three approved seal fittings 10 RFT9739 Transmitter

RFT9739 rack-mount model number matrix RFT9739 Transmitter Model RFT9739 transmitter R Housing options Rack-mount Power-supply options 1 110/115 VAC 2 220/230 VAC 3 12-30 VDC E Configuration Enhanced EMI immunity (CE compliant) requires installation with Micro Motion cable type RFP or RFT installed in conduit, or type CBPS or CBPA installed with approved cable glands M U B Approvals Micro Motion standard (no approvals) UL CENELEC intrinsically safe sensor outputs F S Connector options Fast-on/solder terminals Y-shaped screw terminals Example* RFT9739 R 2 E B F *Example: RFT9739 R 2 E B F = RFT9739 rack-mount transmitter, configured for 220/230 VAC power supply; enhanced EMI immunity; CENELEC compliant; with fast-on/solder terminal connectors RFT9739 Transmitter 11

Due to Micro Motion's commitment to continuous improvement of our products, all specifications are subject to change without notice. Micro Motion, ELITE, and ProLink are registered trademarks of Micro Motion, Inc., Boulder, Colorado. Rosemount is a registered trademark of Rosemount, Inc., Eden Prairie, Minnesota. HART is a registered trademark of HART Communication Foundation, Austin, Texas. Modbus is a registered trademark of Modicon, Inc., North Andover, Massachusetts. For the latest Micro Motion product specifications, view the PRODUCTS section of our Web site at www.micromotion.com Micro Motion Europe Groeneveldselaan 8 3903 AZ Veenendaal The Netherlands Tel +31 (0) 318 549 549 Fax +31 (0) 318 549 559 Toll - free numbers (UK only) Tel 0800-966 180 Fax 0800-966 181 Rest of Europe Tel +31 318 549 443 Fax +31 318 549 449 1999, Micro Motion, Inc. All rights reserved PS-00257-EU (10/99)