Open Channel Flowmeter 713

Similar documents
713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

CHANFLO 2500 / 3000 Open Channel Flowmeters

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Design and applications

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

TMU. Coriolis Mass Flow Meter. for liquids and gas

phix Compact 4.10 PH, TEMPERATURE AND REDOX MEASUREMENT DATASHEET EN 4.10 PHIX DATASHEET 1812

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

Coriolis Massflowmeter

Mineral-insulated resistance thermometers to EN

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Mobrey open channel flow measurement systems

Coriolis Massflowmeter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

KFS. Flap-type flow meter. Design and range of application

Temperature head transmitter itemp PCP TMT 181

LST400 Ultrasonic level / open channel flow transmitter

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Sultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.

PAD - Heavy Duty Differential Pressure Trasmitter

Coriolis Mass Flow Meter Model TM

Technical specification FLUXUS F401 H2O

mass flowmeter for compressed air

SALES SERVICE +358 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

ED701 General Industry Pressure Transmitter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

MagFlux ELECTROMAGNETIC FLOWMETERS BROCHURE EN 3.05 MAGFLUX BROCHURE 1401

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Digital inductive conductivity transmitter

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Magnetic Inductive Flowmeter

Ultrasonic level transmitter, non-contact

Process ph/orp Analysis Systems

Digital conductivity transmitter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Magnetostrictive Level Transmitter

Specification DataFile

Positive Displacement Flow sensors

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

S200 I/O System Units

Magnetic-Inductive flow Meter fmi

Electro-Magnetic Flowmeters COPA-XE

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

Ultrasonic level meters ULM 70

ICARUS ELECTRONIC GAS VOLUME CONVERTER

Universal process controller econtrol

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Field indicator for current loops with HART communication Models DIH50, DIH52

Electromagnetic Flow Transmitter

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

4-20mA, 0-10V and general process measuring bargraph displays

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeter for liquids and gases

SPECIFICATION SHEET DISSOLVED OXYGEN ANALYZER/TRANSMITTER SYSTEM CONFIGURATION

Temperature transmitter itemp PCP DIN rail TMT 121

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Condumax W CLS15 and CLS15D

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

E l e c t r o m a g n e t i c f l o w m e t e r s

EN-2018 MAGNETIC FLOW METERS

MAGNETICALLY CONTROLLED LEVEL INDICATOR. Type: ITA-AVK. Manual. November 2008

FLOWMETER. Siemens MAG 5000/6000. Overview

Coriolis Massflowmeter

Submersible pressure sensor For water and wastewater Model LW-1

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

Universal process controller econtrol

Submersible pressure sensor For oils and fuels Model LF-1

Technical Specification FLUXUS ADM 8x27

FAST SAMPLING CONVERTER

S T T U S I N S T R U M E N T S

Page Type Resolution (mm) min. max. Output

Precision Thermistor Sensors

Operation. LEVEL Transmitters

Screw-in resistance thermometers with plug connector

IFC 010 Signal Converter

Rotary Measuring Technology

Preset counters, electronic

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

SITRANS T measuring instruments for temperature

Rod probe With coaxial tube reference probe

+GF+ SIGNET Temperature Transmitter Instructions

Digital flowmeter for continuous flow measurement

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

Transcription:

Open Channel Flowmeter 713 General Flow Converter 713 is designed for measuring and recording water flow in open ducts and channels. Flow Converter 713 is a complete instrument for the measuring of instantaneous flow and recording of totalised water flow. It can be adapted to any type of weir or flume. 3.1 Special features Supplied with either ultrasonic or hydrostatic sensor. Maximum accuracy with measuring ranges down to 0-10 cm. Flow Converter 713 is calibrated from the front panel. Easy to operate with setup information in English or other user-specified language. Security access code can be programmed. Adaption to any kind of weir or flume. Built-in control of Sampler e.g. MJK 780. Built-in totalizer with counter. All values stored in an E 2 -prom. Indication of average flow (m 3 /hour) actual, the last hour, today, the last 24 hours. Indication of accumulated flow (m 3 ) actual, the last hour, today, the last day. If 713 is set as an emergency stormflow meter, the number of stormflows, stormflow time and volume and start and stop time for the last stormflow are counted. Alarm can be set for high and low flow, and excess of 1- and 24-hour volumes. Application The Flow Converter 713 is especially used for measurement and recording of flow in public and industrial sewage plants. It is also installed in pumping stations for recording of emergency stormflow and for measuring in fish farming, in channels for irrigation system and for measurement in streams and rivers. Function The sensor of the Flow Converter provides a signal proportional to the level. The amplifier linearizes the signal from the sensor so it is proportional with the flow rate. The Flow Converter 713 can calculate flow on the basis of one of the three following principles: Preprogrammed formulas for different dimensions of the most common flumes and weirs such as Parshall-Venturi flumes and V-notch weirs based on ISO 1438. When using non-standard flumes or weirs the calculation formula can be programmed. For flumes where no calculation formula exists, a number of known flow values can be entered, on the basis of these a point-linearization is made. This is used for flumes which do not follow the ISO 1438 standard. GB 3.1 OpenChanFlow 713 080617 As our products are developed continuously, we reserve the right to make any change in dimensions and specifications.

Specifications Ultrasonic Sensor Measuring range 0-1 m ; 0-3 m Frequency 125 khz ; 30 khz Spreading 6 ; 3 Temperature -20...+60 C Blocking distance 40 cm ; 75 cm Dimension 103 94 mm Materials PP Green/Glass filled polyester Black/Glass reinforced epoxy White Cable Shielded, oil resistant PVC insulation, length 12 metres. Can be extended to Max. 50 m with 690010 cable ; Max. 100 m with 690010 cable Housing IP 68, water proof, withstands immersion, max. 1 bar CE EN50081-1, EN50082-1 Pressure Transmitter Expert 3400 Measuring ranges 203961 Expert 3400, range 0-0.3 m 1 RG top 203962 Expert 3400, range 0-1 m 1 RG top 203963 Expert 3400, range 0-3 m 1 RG top Temperature range -10... +50 C Temp. drift Better than ± 0,01% / C Measurement accuracy Better than ± 0,1% FS @10-30 C / ± 0,2% FS @ full temp. range Long time stability Better than ± 0,1% FS per year Dimension 50 167 mm voltage 10-30 V DC (12-30 V DC for cable lengths above 110 m) Output signal 2-wire, 4-20 ma (passive transmitter) Cable 2 0,5 mm2 (pressure) + 5 x 0,15 mm2 (data), shielded, PUR insulation Cable length 12 m. Can be extended max 600 Ω Enclosure IP 68, withstands a static pressure equal to max. overpressure. Approvals ATEX: II 2G EEx ia IIC T5/T6 and CE: EN61000-6-3/-4:2001, EN61000-6-1/-2:1999,EN50014:1997 E, EN50020:2002 Converter 713 Measuring ranges 0-0,3 m, 0-1 m, 0-3 m Dimensions 185 240 115 mm (h w d) 220-240V AC, 110-120V AC or 24V DC appr. 10 VA Temperature -20...+60 C Materials House and cover: Polystyrol Housing IP 65 Input signal From ultrasonic sensor, pressure transmitter or 4-20 ma Digital s Terminals 6-17: relay 1-4, max. 250 V, 4 A resistive load, max. 100 VA inductive load. Can be chosen as alarm, counter, flow>0 or sampler s. Terminals 18-20: relay 5 pulse (optocoupler) max 36 V, 50 ma one shot, 100 msec - 10 sec programmable. Analogue Terminals 21-22: 0-20 / 4-20 ma, max. 500 Ω, galvanic isolation. Serial RS 232 prepared Calculation Standard formulas according to ISO 1438 Optional formula Q = C h x or point-linearization Indication 2 24 characters LCD display for readout and programming Accuracy ±1 % (min. ±1 mm) CE EN50081-1, EN50082-1 2

Ultrasonic measuring system Standard connection Flow converter 713 Ultrasonic Measuring System Relay 1-4 Relay 5 pulse Ultrasonic Sensors 200570-200580 Analog n/a Ultrasonic measuring system using Shuttle Level Transmitter The level transmitter 511 is applied as preamplifier when the distance between the measuring location and the converter is greater than 50/100 m. It is the resistance (max. 600 Ω) which limit the length with a 3-wire, 4-20 ma supply. Flow Converter 713 4-20 ma Supplied Shuttle level transmitter Level transmitter type 511U 10 11 12 0-30 cm 0-100 cm 0-3 m 4-20mA Relay 1-4 Relay 5 pulse Analog Ultrasonic Ultrasonic sensor sensors 7005 200570-200580 Hydrostatic measuring system Flow Converter 713 Hydrostatic measuring system GND or shield Relay 1-4 Relay 5 pulse Analog n/a Pressure transmitter Expert 3400 Mounting Ultrasonic sensor The ultrasonic sensor is mounted behind the weir at a distance of 3-4 times the head.the ultrasonic sensor has a very narrow spreading of the sound signal and the distance to the highest level to be measured must not be less than the blocking distance and not more than the range + the blocking distance. Hydrostatic sensor The pressure transmitter is mounted behind the weir at a distance of 3-4 times the head or in a stilling well, to the flume. The pressure transmitter has as standard a 1 thread for mounting on a pipe. Min. distance for ultrasonic sensor= max. weir head + deadband. Hydrostatic sensor. 3

Dimensions Converter 713 Pressure transmitter Expert 3400 Ultrasonic sensors 200570-200580 1 ISO 135 mm 32 mm Dia. 50 mm Sensor stand for flume Bracket for Ultrasonic Sensor Universal bracket Order numbers Open Channel Flowmeter 713 201455 713U-1121, ultrasonic meas. system, incl. 200580, meas. range 0-1 m 201460 713U-1131, ultrasonic meas. system, incl. 200570, meas. range 0-3 m 202600 713P-1104, without sensor, 4-20 ma supplied 201464 713 - system complete with Shuttle Level Transmitter (202600 + 201215 202650 713P-1114, hydrostatic meas. system, incl. 203961, meas. range 0-0,3 m 202655 713P-1124, hydrostatic meas. system, incl. 203962, meas. range 0-1 m 202660 713P-1114, hydrostatic meas. system, incl. 203963, meas. range 0-3 m Accessories for Open Channel Flowmeter 713 200105 Panel mounting kit 200115 Local mounting kit with rainproof roof 200521 713U, 10-30 V DC supplied 200522 713P, 10-30 V DC supplied Accessories for Ultrasonic Sensor 200590 Connection box for cable for Ultrasonic Sensor 200595 Cable lenght not standard (+ cable pr. meter above standard lenght) 690010 Cable for Ultrasonic Sensor (state meter) 200205 Universal bracket 200220 Bracket for Ultrasonic Sensor 200230 Sensorstand for flume for Ultrasonic Sensor, max. flume width 550 mm 200235 Sensorstand for flume for Ultrasonic Sensor, max. flume width 950 mm Accessories for Pressure Transmitter Expert 3400 202922 Connection box for cable for Pressure Transmitter 202923 Connection box for cable for Pressure Transmitter, with connector for programmes 200126 Display insert 531 for connection box 202920 Cable lenght not standard (+ cable pr. meter above standard lenght) 691014 Cable for Pressure Transmitter Expert 3400 (state length in metres) 4

For measurement of water flow in open systems MJK supplies a range of prefabricated flumes. The flumes are manufactured in PVC, glass fibre and stainless steel. The flumes are ready for installation. Parshall, Venturi and Palmer & Bowlus flumes are made according to standards. The flumes are delivered as complete channel sections ensuring the best possible measuring accuracy. Standard types which cover the range from 25 m 3 /h to 2000 m 3 /h. Easy fitting and mounting. For more information about the MJK programme of flumes, see data sheet 3.8. Parshall flume Venturi flume Palmer & Bowlus flume

The Flow converter 713 is used for measuring the flow in open flumes and weirs. The determination of the flow rate is based on the following basic mathematical function: FLOW Q = f(level x. constant) The exponent x and the constant depends on the dimensions of the weir or the flume. The method of measurement and linearization complies with the norm ISO 1438. The norm indicates how the head over the weir and flumes are constructed and gives the calculations for the linearization. The Flow converter is operated by means of 4 function keys: the flow key, the summation key, the alarm key and the sample key. See the description of the function keys below. Function key for flow Q (t) : the instantaneous flow average flow for the last hour average flow today average flow for the last 24 hours Totalized ΣQ (t) : Flow total flow. total flow for the last hour. total flow today. total flow for the last 24 hours. Storm flow measurement total number of storm flows total time of storm flow total flow of storm flow. amount at last storm flow. storm flow start/end Function key for alarms: display of the previous 9 alarms with time for start and end of alarm. The flowmeter has alarms for: sensor errors (internal monitoring of flow converter), high and low flow alarm, high hour flow, high day flow. Function key for sampler: total number of samples total number of samples today total number of samples for the last 24 hours. The flow meter has s for transmission of measuring and counting values for connection to printer or data transmitter. Distributed by: MJK offices: www.mjk.dk mjk@mjk.dk +45 45 56 06 56 Norway www.mjk.no mjk@mjk.no +47 69 20 60 70 The Netherlands MJK Automation North America A/S www.mjk.com www.mjk.com mjknl@mjk.com mjkusa@mjk.com +31 251 672171 +1 847 482 8655 Sweden Australia www.mjk.se www.mjk.com kontoret@mjk.se mjk@mjk.com +46 53 31 77 50Fax: +45 +61 45 3 9755 56 06 152946