Max. sp Min. spe Negativ speed s Synchro out speed refere selection Menu 13. g t x (-1) UMV 4301

Similar documents
Ref /b VARMECA 10 Variable speed motors and geared motors. Parameter-setting manual

Advanced user guide. Commander SX. IP66/Nema 4X AC Variable Speed Drive en / a. Part Number :

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

GS1 Parameter Summary Detailed Parameter Listings...4 9

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

HPVFP High Performance Full Function Vector Frequency Inverter

Operating Instructions

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

6.9 Jump frequency - Avoiding frequency resonance

NX series Constant and variable torque Variable Speed Drives for induction motors

[ 4 ] Using pulse train input (F01 = 12)

vacon nx all in one application manual ac drives Phone: Fax: Web: -

Commissioning manual. Powerdrive MD2/FX

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

NX Series Inverters. HVAC Pocket Programming Guide

smd frequency inverter

CHAPTER 8 PARAMETER SUMMARY

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

User Guide. Optidrive Plus 3 GV Compact. OEM AC Variable Speed Drive kW (1 2HP) Installation and Operating Instructions

vacon nx ac drives all in one application manual

OPC-E1-PG3 Specifications

POWERDRIVE Variable speed drive

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

Unidrive. EF Advanced User Guide. Model sizes 1 to 5. Universal Variable Speed AC Drive for induction and servo motors

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

PROXIDRIVE IP66 variable speed drive

THYFREC-VT210S 400V System 37 to 315kW (C/T) 400V System 45 to 370kW (V/T) QUICK START GUIDE

THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE

user's manual nx frequency converters beam pump application asfiff13

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Troubleshooting Alarm Displays Warning Displays

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Inverter Drive /Vector Drive Motors & Controls

Altivar 68 Telemecanique

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

Multi-function, Compact Inverters. 3G3MV Series

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

Goodrive inverter for air compressor. Preface

User Guide. Optidrive Plus 3 GV Compact & Optidrive PCE. Compact AC Variable Speed Drive & Motor Mount Enclosure

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

S11 Adjustable Speed Drive Engineering Specification

13. Before making a service call Trip information and remedies

Parallel. Parallel. data transmission. Technical Information TR - ECE - TI - GB /05/2016

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

POWERDRIVE Dual output variable speed drive

Preface. Notes. Thank you for purchasing the VTP8 series AC drive.

UMV Open or closed loop flux vector controller. Installation and maintenance. This manual must be given to the end user. Faster/slower function

SCS Automation and Control Ltd

FUJI Inverter. Standard Specifications

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

MTY (81)

Contents. Safety Information and Precautions Product Information Operation Panel (Keypad & Display) Quick Setup...

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

TOSVERT TM VF-nC3 Parameter List

AZ Series. Function Edition. Closed Loop Stepping Motor and Driver Package. Operation. I/O signals. Parameter

Document number: Document version: r2 Date of release: Copyright Emotron AB 1998 Emotron AB reserves the right to alter product

Before you operate the inverter, the parameters that you must first program are the basic parameters.

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

Analog Servo Drive 30A8

POWERDRIVE Regenerative variable speed drive

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

PSF-520 Instruction Manual

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

SAFETY INSTRUCTIONS WARNING

Installation and Operational Instructions for ROBA -switch Type 017._00.2

MTY (81)

In the event of a failure, the inverter switches off and a fault code appears on the display.

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2)

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

IF30. User's manual. Description. Table of contents IF30

System Manual MOVITRAC LT E. Edition 04/2005 EA / EN

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

MD310 Quick Start Manual. General-Purpose AC Drive

ADTECH Solar inverter

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. Servo Amplifier Instruction Manual (Troubleshooting)

Instruction Manual. General application Inverter. IMO idrive2 XKL

KSC-10 Kelvin Speed controller 10A Rev.00 of 23/01/17

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

G320X MANUAL DC BRUSH SERVO MOTOR DRIVE

Impulse system MPT 700. Manual Edition GB

CROSS Chassis from 160 A to 450 A

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

Transcription:

Réf. 335-4.33 / a -.98.5 X-.39 Synchro output speed reference Menu 3 Max. sp Min. spe Negativ speed s.4 Synchro out speed refere selection Menu 3 Skip frequency Skip width.29.3.3 g t Run Run FWD REV 27 28 x (-).2. Maximum limit Minimum limit.3 Accele.4 Decele This manual must be given to the end user Speed skip Skip width.2.22.2.23 "S" ramp selection Ramp curve in "S " Standard with automatic extension (Stnd. Hd) Fixed ramp (FAST) Controlled ramp (St d Ct) 2. Reference before ramp.8.9.5 UMV 43 controllers for asynchronous and Settings and synoptic views.6 Select stopping mode Select deceleration mode R a

UMV 43 NOTE LEROY-SOMER reserves the right to modify the characteristics of its products at any time in order to incorporate the latest technological developments. The information contained in this document may therefore be changed without notice. LEROY-SOMER gives no contractual guarantee whatsoever concerning the information published in this document and cannot be held responsible for any errors it may contain, nor for any damage arising from its use. CAUTION For the user's own safety, this speed controller must be connected to an approved earth ( B terminal). If an accidental start of the installation represents a risk for personnel or the machinery to be driven, it is imperative that the equipment is supplied via an isolating device and a circuit-breaking device (power contactor) which can be controlled by an external safety system (emergency stop, fault detector). The speed controller is fitted with safety devices which can stop the speed controller and therefore stop the motor. The motor itself can become jammed for mechanical reasons. Finally, voltage fluctuations, and in particular power cuts, can also cause the motor to switch off. The removal of the causes of the shutdown can lead to restarting, which may be dangerous for certain machines or installations. In such cases, it is essential that the user takes appropriate precautions against the motor restarting after an unscheduled stop. The speed controller which is the subject of this manual is a component designed to be integrated in an installation or an electrical machine and can under no circumstances be considered to be a safety device. It is the responsibility of the manufacturer of the machine, the designer of the installation or the user to take all necessary precautions to ensure that the system complies with current standards and to provide devices to ensure the safety of equipment and personnel. Use of the speed controller for lifting : special instructions must be followed when implementing this application. These instructions are provided in a specific manual which is available on request. It is the responsibility of the user to request this manual from his usual LEROY-SOMER contact. LEROY-SOMER declines all responsibility in the event of the above recommendations not being observed.... Manual corresponding to software version 3. and 3. Update of manual 2465-4.33/c -3.97 For more recent software versions, refer to the enclosed leaflet or contact LEROY-SOMER 2

UMV 43 SAFETY AND OPERATING INSTRUCTIONS FOR SPEED CONTROLLERS (In accordance with the low voltage directive 73/23/EEC modified by 93/68/EEC) Throughout the manual, this symbol warns against consequences which may arise from inappropriate use of the speed controller, since electrical risks may lead to material or physical damage as well as constituting a fire hazard. - General Depending on their degree of protection, speed controllers can contain live bare parts, either moving or rotating, as well as hot surfaces, during operation. Unjustified removal of protections, incorrect use, faulty installation or inappropriate operation could represent a serious risk to personnel and equipment. For further information, consult the manual. All work relating to transportation, installation, commissioning and maintenance must be performed by experienced qualified personnel (see IEC 364 or CENELEC HD 384, or DIN VDE and national specifications for installation and accident prevention). In these basic safety instructions, qualified personnel means persons competent to install, mount, commission and operate the product and possessing the relevant qualifications. 2 - Use Speed controllers are components designed for integration in installations or electrical machines. When integrated in a machine, commissioning must not take place until it has been verified that the machine conforms with Directive 89/392/EEC (Machinery Directive). It is also necessary to comply with standard EN 624 which stipulates in particular that electrical actuators (which include speed controllers) cannot be regarded as circuit-breaking devices and certainly not as isolating devices. Commissioning can only take place if the requirements of the Electromagnetic Compatibility Directive (89/336/EEC, modified by 92/3/EEC) are met. Speed controllers meet the requirements of the Low Voltage Directive 73/23/EEC, modified by 93/68/EEC. The harmonised standards of the DIN VDE 6 series in connection with standard VDE 66, part 5 and EN 646/VDE 558 are also applicable. The technical characteristics and instructions concerning the connection conditions specified on the nameplate and in the documentation provided must be observed without fail. 3 - Transportation, storage All instructions concerning transportation, storage and correct handling must be observed. The climatic conditions specified in the technical manual must be observed. 4 - Installation The installation and cooling of equipment must comply with the specifications in the manual supplied with the product. Speed controllers must be protected against excessive stress. In particular, there must be no damage to parts and/or modification of the clearance between components during transportation and handling. Avoid touching the electronic components and contact parts. Speed controllers contain parts which are sensitive to electrostatic stress and may be easily damaged if handled incorrectly. Electrical components must not be exposed to mechanical damage or destruction (risks to health!). 5 - Electrical connection When work is performed on speed controllers which are powered up, national accident prevention specifications must be respected. The electrical installation must comply with the relevant specifications (for example conductor cross-sections, protection via fused circuit-breaker, connection of protective conductor). More detailed information is given in the manual. Instructions for an installation which meets the requirements for electromagnetic compatibility, such as screening, earthing, presence of filters and correct insertion of cables and conductors) are given in the documentation supplied with the speed controller. These instructions must be followed in all cases, even if the speed controller carries the CE mark. Adherence to the limits given in the EMC legislation is the responsibility of the manufacturer of the installation or the machine. 6 - Operation Installations incorporating speed controllers must be fitted with additional protection and monitoring devices as laid down in the current relevant safety regulations : law on technical equipment, accident prevention requlations, etc. Modification of speed controllers using control software is permitted. Active parts of the device and live power connections must not be touched immediately after the speed controller is powered down, as the capacitors may still be charged. In view of this, the warnings fixed to the speed controllers must be observed. During operation, all doors and protective devices must remain closed. 7 - Service and maintenance Refer to the manufacturer's documentation. This manual must be given to the end user. 3

UMV 43 Notes 4

UMV 43 PREFACE CAUTION This technical manual complements the Installation and Maintenance manual, ref 232. It is essential that before entering any settings for the controller all installation, connection and commissioning instructions contained in the document ref. 232, have been scrupulously adhered to. Both documents are supplied together with the speed controller. If either one is missing, please request it from your usual LEROY-SOMER contact. MENU ORGANISATION MENU Consult the installation and maintenance manual ref. 232 Access to other menus via = 49 3 4 5 6 7 8 9 2 22 23 24 25 26 27 28 29 3 3 UMV COD2 OPTION 4 4 43 44 MENU 7 CONFIGURATION OF ANALOGUE INPUTS/OUTPUTS UMV COM SERIAL LINK OPTION MENU 8 CONFIGURATION OF LOGIC INPUTS/OUTPUTS MENU 3 SYNCHRONISATION MENU 6 SPEED CONTROLLER CONFIGURATION (Keypad, terminal, starting modes, stopping modes, managing microbreaks) CLOCK AND COUNTERS MENU SPEED CONTROLLER STATES FAULT MANAGEMENT BRAKING RESISTORS MENU USER MENU CONFIGURATION SERIAL LINK MENU 9 MENU 2 LOGIC FUNCTIONS COMPARATORS & MENU 4 PID CONTROLLER P I D MENU SPEED REFERENCES MENU 2 RAMPS MENU 3 ENCODER INPUT SPEED LOOP MENU 4 CURRENT LOOP MENU 5 MOTOR CONTROL L L2 L3 U V W M 5

UMV 43 CONTENTS Pages - MENU : SPEED REFERENCE : Selections, limits and filters. - List of Menu parameters... 9 -.2 - Menu synoptic views... 2-3.3 - Explanation of menu parameters... 4 to 7 2 - MENU 2 : RAMPS 2. - List of Menu 2 parameters...... 9 2.2 - Menu 2 synoptic views... 2-2 2.3 - Explanation of menu 2 parameters... 22 to 24 3 - MENU 3 : ENCODER INPUT AND SPEED LOOP 3. - List of Menu 3 parameters... 25-26 3.2 - Menu 3 synoptic views... 27-28 3.3 - Explanation of menu 3 parameters... 29 to 32 4 - MENU 4 : CURRENT LOOP - TORQUE REGULATION 4. - List of Menu 4 parameters... 33 4.2 - Menu 4 synoptic views... 35-36 4.3 - Explanation of menu 4 parameters... 37-38 5 - MENU 5 : MOTOR CONTROL 5. - List of Menu 5 parameters...... 39-4 5.2 - Menu 5 synoptic views... 4-42 5.3 - Explanation of menu 5 parameters... 43 to 47 6 - MENU 6 : MANAGEMENT OF LOGIC CONTROLS AND COUNTERS 6. - List of Menu 6 parameters... 49 6.2 - Menu 6 synoptic views... 5-5 6.3 - Explanation of menu 6 parameters... 52 to 57 7 - MENU 7 : ASSIGNING ANALOGUE INPUTS AND OUTPUTS 7. - List of Menu 7 parameters... 59 7.2 - Menu 7 synoptic views... 6-6 7.3 - Explanation of menu 7 parameters... 62 to 64 8 - MENU 8 : ASSIGNING LOGIC INPUTS AND OUTPUTS 8. - List of Menu 8 parameters... 65 8.2 - Menu 8 synoptic views... 66-67 8.3 - Explanation of menu 8 parameters... 68-69 9 - MENU 9 : LOGIC FUNCTIONS AND +SPEED, -SPEED COMANDS 9. - List of Menu 9 parameters... 7 9.2 - Menu 9 synoptic views... 72-73 9.3 - Explanation of menu 9 parameters... 74-75 - MENU : SPEED CONTROLLER STATES AND DIAGNOSTICS. - List of Menu parameters... 77.2 - Menu synoptic views... 78-79.3 - Explanation of menu parameters... 8 to 83 - MENU : SETTING MENU - SERIAL LINK - CONTROLLER CHARACTERISTICS CHARACTERISTICS. - List of Menu parameters... 85.2 - Menu synoptic views... 86.3 - Explanation of menu parameters... 87 to 89 6

UMV 43 CONTENTS (CONT.) Pages 2 - MENU 2 : PROGRAMMABLE THRESHOLDS 2. - List of Menu 2 parameters...... 9 2.2 - Menu 2 synoptic view... 92 2.3 - Explanation of menu 2 parameters... 93 3 - MENU 3 : SYNCHRONISATION AND INDEXING 3. - List of Menu 3 parameters... 95 3.2 - Menu 3 synoptic views... 97 to 99 3.3 - Explanation of menu 3 parameters... to 2 4 - MENU 4 : PID CONTROLLER 4. - List of Menu 4 parameters... 3 4.2 - Menu 4 synoptic views... 4 4.3 - Explanation of menu 4 parameters... 5-6 5 - MENU 5 : RESERVE... 8 6 - MENU 6 : SMALL OPTION MODULE PARAMETER SETTING... 8 7 - MENU 7 : LARGE OPTION MODULE PARAMETER SETTING... 8 8 - MENU 8 : APPLICATION-SPECIFIC PARAMETERS... 8 9 - MENU 9 : APPLICATION-SPECIFIC PARAMETERS... 8 2 - MENU 2 : APPLICATION-SPECIFIC PARAMETERS... 9 7

UMV 43 Notes 8

UMV 43 - MENU : SPEED REFERENCE : Selection, limits and filters. - List of Menu parameters Parameter Description Type Mode Adjustment range. Read speed reference before limits RO.2 Read speed reference before frequency skips RO.3 Read speed reference before ramp RO.4 Speed reference offset R/W.5 Jog reference R/W.6 Maximum speed or frequency limit R/W Factory setting User setting ±. Hz ±3 min - - - ±. Hz ±3 min - - - ±. Hz ±3 min - - - ±. Hz. Hz ±3 min - min - to 4. Hz.5 Hz to 4 min - 5 min - to. Hz. Hz.7 Maximum speed or frequency limit R/W & to.6 min -.8 Selection of a negative minimum speed R/W or.9 Selection of speed reference offset R/W or. Selection of bi-directional mode R/W or. Start command indicator RO or - -.2 Direction of rotation indicator RO or - -.3 Jog operation indicator RO or - -.4 Selection of speed references R/W to 5.5 Selection of preset speeds R/W to 9.6 Preset speeds cycle time R/W to 4.s.s.7 Reference via keyboard R/W. Hz &.7 to.6 min -.8 Precision reference (integer) R/W.9 Precision reference (decimal) R/W ±. Hz ± 3 min - to.99 Hz.2 Precision reference enable R/W or.2 Preset speed ±. Hz. Hz to to R/W.28 Preset speed 8 & ± 3 min - min - to. Hz. Hz.29 Skip speed R/W & to 3 min - min - & & & & & & to 3 min - & to.99 min - 5. Hz 5 min - 3 min -. Hz min -. Hz. min -.3 Width of skip speed R/W to 5. Hz.5 Hz & to 5 min - 5 min -.3 Skip speed 2 R/W & to. Hz. Hz to 3 min - min - 9

UMV 43 List of Menu parameters (cont.) Parameter Description Type Mode Adjustment range.32 Width of skip speed 2 R/W & Factory setting to 5. Hz.5 Hz to 5 min - 5 min - User setting.33 Skip speed 3 R/W & to. Hz to 3 min -. Hz min -.34 Width of skip speed 3 R/W to 5. Hz.5 Hz & to 5 min - 5 min -.35 Skip speed zone indicator RO or - ±.6 or.36 Analogue speed reference R/A - -.7 to +.6 ±.6 or.37 Analogue speed reference 2 R/A - -.7 to +.6.38 Speed reference adjustment R/A ±. % -.39 Speed reference from Synchro mode RO & ±. Hz ±3 min - - -.4 Selection of speed reference from synchro mode RO or -.4 Selection of reference via to R/A or -.47 logic inputs.48 Preset speed cycle reset R/W or.49 Selected reference indicator RO to 5 -.5 Selected preset speed indicator RO to 8

UMV 43 Notes

UMV 43.2 - Menu synoptic views.2. - Selection of the speed reference Symbols Read and write Read only Read and assign Speed reference offset Analogue reference Analogue reference 2.4.36.37 Speed reference adjustment Ref. + 2 Ref. x.38 Offset selection.9 Analogue ref. 2 selection.4 Preset speed selection bit Preset speed selection bit Preset speed selection bit 2.45.46.47 Preset speed selection.5 3 4 Preset speed selection.42 Keypad selection.43 Preset speeds VP VP 2 VP 3 VP 4 VP 5 VP 6 VP 7 VP 8 Preset speed cycle Cycle timer.2.22.23.24.25.26.27.28.6 VP VP2 VP3 VP4 VP5 VP6 VP7 VP8 2 3 4 5 6 7 8 VP8 VP7 5.5.49.4 2 3 4 5 9 VP VP2 VP3 Precision ref. selection Speed reference selection.44 Speed reference. A Cycle reset.48 VP6 VP4 VP5 Reference via keypad.7 Precision reference.8.9 Integer value Decimal Store.2 Enable precision reference 2

UMV 43.2.2 - Limits and filters 26 27 28 MENU 8 Symbols Read and write Read only Read and assign MENU 6 Change direction of rotation Jog command Start/stop command.3.2. Polarity selection for the speed reference. OR.6.7 A Negative min. speed selection.8.6 Skip speeds 2 3.29.3.3.32.33.34 Skip Width Jog reference.5 X(-).6.6.2 Speed reference before skip frequencies.3 Speed reference before ramp Menu 2 Synchro output speed reference Menu 3.39.35 Synchro output speed reference selection Menu 3.4.6 Skip speed zone.7 3

UMV 43.3 - Explanation of parameters in menu Symbols : - open loop - closed loop - servo mode.: : Read speed reference before limits Adjustment range : : ±. Hz Indicates the speed reference value..2 &.3 : Read speed reference before ramp Adjustment range : : ±. Hz.2 : Indicates the speed reference after the limits but before frequency skips..3 : Indicates the speed reference after frequency skips but before the acceleration or deceleration ramps..4 : Offset speed reference Adjustment range : : ±. Hz Factory setting : :. Hz This reference is added to the selected reference if parameter. 9 is at. It can be used to correct the main reference selected to obtain a precise setting..5 : Jog reference Adjustment range : : to 4. Hz Factory setting : :.5 Hz Speed reference used for jog operation. : ± 3 min - : ± 3 min - : ± 3 min - : min - : to 4 min - : 5 min -.6 : Maximum speed limit Adjustment range : : to. Hz (See 3.2 ) Factory setting : : 5. Hz If parameter. 8 is at, this parameter sets the maximum limit for both directions of rotation. When. 8 is at, this is the maximum limit in forward operation only. : Sets the maximum frequency. Slip compensation may cause a slightly higher output frequency. & : Sets the maximum speed..7 : Minimum speed or frequency limit Adjustment range : If. 8 = : to.6 If.8 = : to -. Hz : to -3 min - (See 3.2 ) Factory setting : :. Hz If parameter. 8 is at, this parameter sets the minimum limit in uni-directional mode. Inactive when operating in jog or bi-directional mode. When parameter.8 is at, this is the negative minimum limit in reverse operation..8 : to 3 min - : 5 min - : 3 min - : min - : Selection of a negative minimum speed Adjustment range : or Factory setting : : The minimum limit. 7 can be between and the maximum limit. In this case, the adjustment range of the reference will be between. 7 and. 6 in forward operation and -.7 and -.6 in reverse operation. : Parameter.7 is used as a maximum limit in reverse operation. The adjustment range for the reference is then from.7 in reverse operation to.6 in forward operation. CAUTION : Operation in Jog or in bi-directional mode invalidates the minimum limit. 4

UMV 43.9 : Selection of speed reference offset Adjustment range : or Factory setting : : The speed reference offset added to the selected reference corresponds to the value which can be adjusted by parameter.38. : The offset takes the value of parameter.4.. : Selection of bi-directional mode Adjustment range : or Factory setting : : All negative references are treated as zero. : Enables the direction of rotation to be changed using the reference polarity.. to.3 : Drive control indicators de contrô Adjustment range : or These indicators are used to enable the control commands...2.3 : = Stop : = Run : = Forward : = Reverse : = Jog not confirmed : = Jog confirmed.4 : Selection of speed reference Adjustment range : to 5 Factory setting : This parameter is used to select the speed reference. It functions as follows : : Selection of the reference via logic inputs : Analogue reference 2 : Analogue reference 2 3 : Reference using preset speeds 4 : Reference via keypad 5 : Precision reference When this parameter is at, the reference used depends on the enabling of logic inputs assigned to parameters.4 to.44..4.42.43.44 : Selects analogue reference 2 : Selects preset speeds : Selects reference via keypad : Selects precision reference - If all these parameters are at, analogue reference will be selected. - If more than one of these parameters is at, it is the highest parameter which is taken into account..5 : Selection of preset speeds Adjustment range : to 9 Factory setting : This parameter is used to select the preset speeds. It functions as follows : : Selection of preset speeds via logic inputs : Preset speed 2 : Preset speed 2 3 : Preset speed 3 4 : Preset speed 4 5 : Preset speed 5 6 : Preset speed 6 7 : Preset speed 7 8 : Preset speed 8 9 : Automatic preset speed cycle When this parameter is at, the required preset speed is selected and is linked to the logic inputs assigned to the parameters.45 to.47. Selection is made according the following table..45.46.47 selected preset speed 2 3 4 5 6 7 8 When this parameter is at 9, the speed controller performs an automatic cycle VP --> VP2 ------ VP7 --> VP8 --> VP ------. Parameter.6 then enables the time switching from one speed to another to be adjusted..6 : Preset speed cycle times Adjustment range : to 4. s Factory setting :.s When an automatic cycle is selected (.5 = 9), this parameter sets the time for switching from one preset time to another. When parameter.48 goes to, the cycler is reset to and preset speed is selected..7 : Reference via keypad Adjustment range :.8. Adjustment range.7 to.6 (.7 >) ±.6 to.6.7 to.6 (.7 ) Factory setting : This parameter is used to adjust the reference when adjustment via keypad is selected (.4 = 4). Use the D key to increase the reference and the E key to reduce it. The reference value is stored during a power cut and is automatically reinitalised when the power is restored. On a return to factory settings.7 is reset to zero. 5

UMV 43.8,.9 : Precision reference Adjustment range :.8.9 & Factory setting : & : Normally, the frequency reference cannot have a resolution greater than.3 Hz. Using the precision reference enables a resolution of. Hz to be obtained. In this case,.8 is used to adjust the integer value of the reference and.9 the decimal value. and : The precision reference enables a resolution of. min - to be obtained..9 always has a positive value, the final precision reference being.8 +.9,.9 adds a value to.8 when this is positive and subtracts a value when.8 is negative..2 : Enabling the precision reference Adjustment range : or Factory setting : Since the precision reference is adjusted by 2 parameters,.2 is used to avoid the reference being used unexpectedly while it is being updated. : The precision reference is stored in the memory. : The precision reference is enabled..2 to.28 : Preset speeds Adjustment range : ±. Hz to.99 Hz ± 3 min - to.99 min -.8.9. Hz. Hz min -. min - : ±. Hz : ± 3 min -.29,.3 : Skip speeds.33 Adjustment range : Factory setting : Three skip speeds are available to avoid critical machine speeds. When a parameter is at, the function is deactivated..3,.32 : Width of skip speeds.34 Adjustment range : Factory setting : These parameters define the width of the skip around the avoided speed. The total skip speed is therefore equal to the threshold set ± skip width..35 : Skip speed zone indication Adjustment range : or This parameter is at when the selected reference is found within the skip speed zones. In this case, the motor speed does not correspond to the required reference..36,.37 : Analogue speed references and 2 Adjustment range :.8 = : ±.6 : to. Hz : to 3 min - :. Hz : min - : to 5. Hz : to 5 min - :.5 Hz : 5 min - Hz.8 = : -.7 to +.6 Hz Factory setting : :. Hz : min - The analogue inputs assigned to these parameters are automatically scaled so that. % of the input corresponds to the maximum speed. Equally input level % corresponds to the minimum reference (.7 )..2 to.28 respectively enable preset speeds VP to VP8 to be defined. 6

UMV 43 Uni-directional mode (.8 =. = ) Reference.6.4 : Selection of the speed reference from synchro mode Adjustment range : or This parameter is at when synchro mode has been enabled (menu 3) and.39 is then used as a priority speed reference..7 Bi-directional mode (. = ) Reference R max. %.4 to.47 : Selection of the reference via logic inputs Adjustment range : or These parameters are used to check the selection of the reference via logic inputs (see parameters.4 and.5 ).4.42.43 : Selection of analogue reference 2 : Selection of preset speeds : Selection of reference via keypad -. +. %.44.45 : Selection of precision reference : Selection of preset speeds bit.8 =, R max =.6. - R max.46.47 : Selection of preset speeds bit : Selection of preset speeds bit 2.8 =, R max = the higher of.6 or.7.38.39 Adjustment range : : Adjustment of speed reference Adjustment range : ±.% An offset, proportional to the selected reference can be added to this reference. The multiplication coefficient is determined by the analogue input assigned to parameter.38..38 Final ref.. = selected ref. x ( + ). : Speed reference from synchro mode : ±. Hz : ± 3 min - In synchro mode (menu 3) this parameter is used as a priority speed reference..48 : Preset speed cycle reset Adjustment range : or Factory setting : When this parameter is set to, the preset speed cycler (.5 = 9) is reset to zero. In this case the reference returns to preset speed. This parameter can be used to check the start of a cycle via logic input..49 : Selected reference indicator Adjustment range : to 5 Shows the reference which has been selected..5 : Selected preset speed indicator Adjustment range : to 8 Shows the selected preset speed. 7

UMV 43 Notes 8

UMV 43 2 - MENU 2 : RAMPS 2. - List of Menu 2 parameters Parameter Description Type Mode Adjustment range 2. Frequency or speed reference after ramp RO & ±. Hz ±3 min - Factory setting - - User setting 2.2 Enable ramps R/W & or 2.3 Ramp integration locking R/W or 2.4 Decleleration mode R/W to 2 2 2.5 Acceleration ramp adjustment range R/W or 2.6 Enable S ramp R/W or to 3. s 2 / Hz 3. s 2 /Hz 2.7 S ramp curve R/W to 3. s 2 / min -.5 s 2 / min -.3 s 2 / min - 2.8 DC bus voltage threshold R/W to 8 volts 7 volts 2.9 Selection of different FWD/REV ramps R/W or 2. Selection of acceleration ramps R/W to 9 2. to 2.4 Acceleration ramp to Acceleration ramp 4 R/W to 32. s/ Hz to 32. s/ min - to 32. s/ min - 5. s/hz 2. s/ min -.2 s/ min - 2.5 2.6 2.7 2.8 Acceleration Ramp FWD 5 or REV Acceleration Ramp FWD 6 or REV 2 Acceleration Ramp FWD 7 or REV 3 Acceleration Ramp FWD 8 or REV 4 R/W to 32. s/ Hz to 32. s/ min - to 32. s/ min - 5. s/hz 2. s/ min -.2 s/ min - to 32. s/ Hz.2 s/hz 2.9 Jog Acceleration Ramp R/W to 32. s/ min -. s/ min - to 32. s/ min -. s/ min - 2.2 Selection of deceleration ramps R/W to 9 2.2 to 2.24 Deceleration ramp to Deceleration ramp 4 R/W to 32. s/ Hz to 32. s/ min - to 32. s/ min -. s/hz 2. s/ min -.2 s/ min - 2.25 Deceleration Ramp FWD 5 or REV to 32. s/ Hz. s/hz 2.26 Deceleration Ramp FWD 6 or REV 2 R/W to 32. s/ min - 2. s/ min 2.27 Deceleration Ramp FWD 7 or REV 3-2.28 Deceleration Ramp FWD 8 or REV 4 to 32. s/ min -.2 s/ min - 2.29 Jog Deceleration Ramp R/W to 32. s/ Hz to 32. s/ min -.2 s/hz. s/hz to 32. s/ min -. s/ min - 2.3 Selection of reverse deceleration ramp R/W to 4 2.3 Selection of reverse acceleration and deceleration ramp R/W to 4 2.32 to 2.4 Selection of ramps via analogue inputs R/A or 9

UMV 43 2.2 - Menu 2 synoptic views 2.2. - Acceleration ramps Symbols Read and write Read only Read and assign FWD Acc. selection (b) 2.32 FWD Acc. selection (b) 2.33 FWD Acc. selection (b2) 2.9 = 2.9 = FWD/REV Acc. FWD Acc. FWD/REV 2 Acc. FWD 2 Acc. FWD/REV 3 Acc. FWD 3 Acc. FWD/REV 4 Acc. FWD 4 Acc. FWD/REV 5 Acc. REV Acc. FWD/REV 6 Acc. REV 2 Acc. FWD/REV 7 Acc. REV 3 Acc. FWD/REV 8 Acc. REV 4 Acc. 2.34 2. 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2 3 4 5 6 7 8 2 3 4 5 6 7.5 8 9 Menu Preset speed selection FWD Acc. ramp selection 2. REV Acc. selection (b) REV Acc. selection (b) 2.38 2.39 5 6 7 8 5 6 7 8 2 3 4 REV Acc. selection 2.3 Jog acc. 2.9 Different FWD/REV ramp selection 2.9 Jog selection.3 Menu A Menu Ramp input speed reference.3 Ramp adaptation REV acceleration N t FWD acceleration N t B C 2.5 Ramp range ( and ) 2.6 S ramp 2.7 S ramp curve 2

UMV 43 2.2.2 - Deceleration ramps Symbols Read and write Read only Read and assign 2.35 2.36 FWD Dec. selection (b) FWD Dec. selection (b) A B C Different FWD/REV ramp selection 2.9 Preset speed selection FWD Dec. ramp selection 2.2 Jog dec. 2.29 N FWD deceleration t N Menu REV deceleration t.5 9 8 7 REV Dec. selection 2.3 Ramp enable ( and ) 2.2 2 3 4 5 6 2 3 4 2 3 4 5 6 7 8 5 6 7 8 5 6 7 8 2.37 2.2 2.22 2.23 2.24 2.25 2.26 2.27 2.28 2.4 2.4 Ramp output speed reference 2. FWD Dec. selection (b2) 2.9 = 2.9 = FWD Dec. FWD/REV Dec. FWD 2 Dec. FWD/REV 2 Dec. FWD 3 Dec. FWD/REV 3 Dec. FWD 4 Dec. FWD/REV 4 Dec. REV Dec. FWD/REV 5 Dec. REV 2 Dec. FWD/REV 6 Dec. REV 3 Dec. FWD/REV 7 Dec. REV 4 Dec. FWD/REV 8 Dec. REV Dec. selection (b) REV Dec. selection (b) Menu 3 2.4 Deceleration mode 2.8 DC bus voltage threshold 2.3 Ramp integration locking 2

UMV 43 2.3 - Explanation of menu 2 parameters Symbols : - open loop - closed loop - servo mode 2. : Frequency or speed reference after ramp Adjustment range : : ±. Hz : ± 3 min - In increments of.hz or min - measurement of the setting after ramps. Used for diagnostics. 2.2 & : Ramp enabling Adjustment range : or Factory setting : : Ramps inhibited. : Ramps enabled. CAUTION : On a stop command ramp shortcircuiting is not active. 2.3 : Ramp integration locking Adjustment range : or Factory setting : : Ramp unblocked. : The ramp is blocked and acceleration (or deceleration) is interrupted. ATTENTION : Ramp integration cannot be locked on a stop command. 2.5 & : Adjustment range of the acceleration ramp Adjustment range : or Factory setting : : In closed loop mode, this parameter is used to select the adjustment range for the acceleration ramp. :. to 32. sec. :. to 32. sec. 2.6 : S ramp enabling Adjustment range : or Factory setting : : The ramp is linear. : A curve (defined in 2.7 ) at the start and end of the ramp avoids load swings. CAUTION : The S ramp is deactivated during controlled decelerations ( 2.4 : Stnd.Ct). 2.7 Adjustment range : Factory setting : Speed reference : : S ramp curve range : to 3. s 2 / Hz : to 3.s 2 / min - : 3.s 2 / Hz in - :.5s 2 / min - :.3s 2 / min - 2.4 : Selection of deceleration mode Adjustment range : to 2 Factory setting : 2 In increments of : Stnd Hd - Standard deceleration ramp with time extension to avoid DC bus overvoltage fault. : FAST - deceleration relative to time up to the current limit. With a drive load, a braking resistance option is essential. 2 : Stnd Ct - Deceleration ramp with DC bus voltage check. Suitable for lightly loaded machines and allowing more flexibility than the stnd.hd. setting. Acceleration Speed t 2 t 2 t = 2.7 + 2. for acceleration, t t 2 t t 2 Controller action t = 2.7 + 2.2 for deceleration. Programmed deceleration DC Bus U Motor speed The value of 2.7 determines the maximum acceleration and deceleration slope, at the start and at the end of the speed change. Compared with a linear ramp, the S ramp increases the total value of t, (t/2 at the start and end of the linear ramp). CAUTION : If a braking resistance is connected to the controller, 2.4 must be set to "FAST". t 22

UMV 43 2.8 : DC bus voltage threshold Adjustment range : to 8 Volts Factory setting : 7 Volts This threshold is used when the speed controller is configured in deceleration mode (Stnd.Hd) or 2 (Stnd.Ct). In mode, if this threshold is too low, the deceleration ramp does not reduce and the machine does not stop. If the threshold is too high and there are no resistances connected, the speed controller trips on a DC bus overvoltage ("O U" fault). In mode 2, if this threshold is too low, the machine makes a freewheel stop. If this threshold is too high and there are no resistances connected, the speed controller trips on a DC bus overvoltage ("O U" fault). The minimum value of this parameter must be greater than the voltage of the DC bus obtained with the maximum mains voltage. (V bus = V mains x V2). 2.9 : Selection of different FWD/REV ramps Adjustment range : or Factory setting : This parameter enables different acceleration or deceleration ramps to be obtained for each direction of rotation. : 8 forward and reverse acceleration and deceleration ramps. : 4 forward acceleration and deceleration ramps, 4 reverse acceleration and deceleration ramps. 2. 2.2 : Selection of acceleration and deceleration ramps Adjustment range : to 9 Factory setting : These parameters are used to select the acceleration and deceleration ramps as follows : : Selection of ramps via logic inputs 2.9 = 2.9 = : Ramp selection FWD/REV FWD 2 : Ramp selection FWD/REV 2 FWD 2 3 : Ramp selection FWD/REV 3 FWD 3 4 : Ramp selection FWD/REV4 FWD 4 5 : Ramp selection FWD/REV 5 REV 6 : Ramp selection FWD/REV 6 REV 2 7 : Ramp selection FWD/REV 7 REV 3 8 : Ramp selection FWD/REV 8 REV 4 9 : Association of ramps with preset speeds When parameter 2. is at, the acceleration ramp depends on the value of parameters 2.32 to 2.34, and similarly when 2.2 is at the deceleration ramp depends on the state of parameters 2.35 to 2.37. These parameters are used as input logic commands in order that ramps can be selected by external command. The ramp selected depends of the following combination of inputs : ACC DEC ACC DEC ACC DEC Ramp 2.34 2.37 2.33 2.36 2.32 2.35 selected 2 3 4 5 6 7 8 When parameters 2. or 2.2 are at 9, acceleration ramp 2. or deceleration ramp 2.2 are automatically adapted to the selected preset speed. 2. to 2.8 : Acceleration ramps Adjustment range : : to 32.s/ Hz : to 32.s/ min - : to 32.s/ min - Factory setting : : 5.s/ Hz : 2.s/ min - :.2s/ min - In increments of.s. Adjustment of the time to accelerate from to Hz or from to min -. Value of ramp (s) = Value of ramp (s) = t(s) x Hz (F2-F) Hz t(s) x min - (V2-V) min - Function Parameter 2.9 = 2.9 = 2. FWD/REV Acc. FWD Acc. 2.2 FWD/REV 2 Acc. FWD 2 Acc. 2.3 FWD/REV 3 Acc. FWD 3 Acc. 2.4 FWD/REV 4 Acc. FWD 4 Acc. 2.5 FWD/REV 5 Acc. REV Acc. 2.6 FWD/REV 6 Acc. REV 2 Acc. 2.7 FWD/REV 7 Acc. REV 3 Acc. 2.8 FWD/REV 8 Acc. REV 4 Acc. Parameter 2.9 is used to configure the controller, either for 8 acceleration ramps in both directions of rotation, or 4 forward acceleration ramps and 4 reverse acceleration ramps. 23

UMV 43 2.9 : Jog acceleration ramp 2.3 2.3 : Selection of reverse acceleration and deceleration ramp Adjustment range : : to 32. s/ Hz Factory setting : :.2 s/ Hz 2.2 to 2.28 Adjustment range : Factory setting : : to 32. s/ min - : to 32. s/ min - :. s/ min - : Deceleration ramps : to 32. s/ Hz : to 32. s/ min - : to 32. s/ min - :. s/ Hz : 2. s/ min - :.2 s/ min - In increments of.s. Adjustment of the time to decelerate from Hz to or from min - to. t(s) x Hz Value of ramp (s) = (F2-F) Hz t(s) x min - Value of ramp (s) = (V2-V) min - 2.2 FWD/REV Dec. FWD Dec. 2.22 FWD/REV 2 Dec. FWD 2 Dec. 2.23 FWD/REV 3 Dec. FWD 3 Dec. 2.24 FWD/REV 4 Dec. FWD 4 Dec. 2.25 FWD/REV 5 Dec. REV Dec. 2.26 FWD/REV 6 Dec. REV 2 Dec. 2.27 FWD/REV 7 Dec. REV 3 Dec. 2.28 FWD/REV 8 Dec. REV 4 Dec. Adjustment range : to 4 Factory setting : When parameter 2.9 is at so that different forward and reverse ramps can be obtained, these parameters are used to select the reverse acceleration ramps and deceleration ramps as follows : : Selection of ramps via logic inputs : Selection of reverse ramp 2 : Selection of reverse ramp 2 3 : Selection of reverse ramp 3 4 : Selection of reverse ramp 4 When parameter 2.3 is at, the reverse acceleration ramp selected depends on the value of parameters 2.38 and 2.39, and similarly when 2.3 is at, the reverse acceleration ramp selected depends on the value of parameters 2.4 and 2.4. These parameters enable ramps to be selected via an external command as follows : ACC DEC ACC DEC Ramp 2.39 2.4 2.38 2.4 selected REV REV 2 REV 3 REV 4 2.32 to 2.4 : Selection of ramps via logic inputs Adjustment range : or These parameters are used for selecting ramps via an external command. 2.32 : bit of FWD/REV Acc or. FWD Acc. selection Parameter 2.9 is used to configure the speed controller, either to obtain 8 deceleration ramps in both directions of rotation, or 4 forward deceleration ramps and 4 reverse deceleration ramps. 2.33 2.34 2.35 : bit of FWD/REV Acc or FWD Acc. selection : bit 2 of FWD/REV Acc. selection : bit of FWD/REV Dec. or FWD Dec. select. 2.29 : Jog deceleration ramp 2.36 2.37 : bit of FWD/REV Dec. or FWD Dec. select. : bit 2 of FWD/REV Dec. selection Adjustment range : : to 32 s/ Hz : to 32. s/ min - : to 32. s/ min - Factory setting : :.2 s/ Hz :. s/ min - 2.38 2.39 2.4 2.4 : bit of REV Acc. selection : bit of REV Acc. selection : bit of REV Dec. selection : bit of REV Dec. selection 24

UMV 43 3 - MENU 3 : ENCODER INPUT AND SPEED LOOP 3. - List of Menu 3 parameters Parameter Description Type Mode Adjustment range Factory setting 3. Final speed reference RO ±. Hz - - & ±3 min - 3.2 Speed feedback RO & ±3 min - - - 3.3 Speed error RO & ±3 min - - - 3.4 Speed loop output RO & ±Max. current limit - - 3.5 Zero speed threshold R/W 3.6 Speed reached alarm low threshold R/W 3.7 Speed reached alarm high threshold R/W 3.8 Overspeed threshold R/W 3.9 Speed reached alarm condition selection R/W or 3. Speed loop proportional gain R/W & to 32 2 3. Speed loop integral gain R/W & to 32 3.2 Speed loop derivative gain R/W & to 32 3.3 Frequency tracking selection R/W or 3.4 Scaling of frequency reference R/W to.. 3.5 Scaling frequency reference R/W. to.. 3.6 Enable frequency output R/W or 3.7 Frequency output adaptation (x 536) R/W or 3.8 Frequency output adaptation (x 92) R/W or 3.9 Additional speed input R/W to 2. Hz. Hz to 2 min - 5 min - to. Hz. Hz to 3 min - 5 min - to. Hz. Hz to 3 min - 5 min - to. Hz to 3 min - to the greater of. Hz 2 min - 4 min -.6 or.7 min - min - 3.2 Selection of additional speed input R/W & or 3.2 Number of points per encoder rev. R/W & 256 to 496 24 496 3.22 Encoder/frequency input selection R/W or & 3.23 Encoder supply voltage selection R/W or 3.24 Encoder impedance adaptation R/W or 3.25 Encoder phase control R/W or - 3.26 Read encoder speed RO ±3 min - - - & & & & User setting 25

UMV 43 List of Menu 3 parameters (cont.) Parameter Description Type Mode Adjustment range Factory setting 3.27 Read encoder position RO to 6383/6384 rev. - - 3.28 Encoder lead/lag R/W to 643/643 rev. - 3.29 Overspeed threshold selection R/W or 3.3 Window on speed feedback filter R/W & to. ms. ms 3.3 Disable ENCPH 9 fault R/W or User setting 26

UMV 43 3.2 - Synoptic views Menu 3 3.2. - Frequency reference via encoder input ( ) Encoder input Frequency signal input Frequency signal output.3 +5V +5V +V 3 4 A A 2 B 3 B 4 C 5 C 6 SUB D 5 connector F F D D + 3.7 2 3 4 Encoder impedance adaptation 3.24 3.22 Encoder/frequency signal selection 7 8 9 3.7.3-3.6 3.6 F F D D Position 3.9 Speed reached alarm condition selection Frequency output selection 3.6 Encoder supply voltage 3.23 Speed 3.27 3.26 Number of points/ rev. 3.2 X 536 selection 3.7 Speed reached reference.6 Frequency tracking selection Ramp output 3.3 speed reference Menu 2 2. f x 3.4 536 x 3.5 X 92 selection 3.8 Menu Speed < low alarm threshold Speed > high alarm threshold Scaling Zero speed.3 Speed < F min.4 Overspeed fault " ovspd ".5.7 X 92 X 536 Final speed reference 3. Speed reached low alarm threshold 3.6 Speed reached high alarm threshold 3.7 Motor frequency 5. Symbols Read and write Read only Read and assign Zero speed threshold Menu 5 3.5.7 3.29 Overspeed threshold selection +.5Hz. Polarity selection 3.8.6 or.7 + 2% Overspeed threshold 27

UMV 43 3.2.2 - Encoder input and speed loop ( & ) Encoder input Frequency signal input.3 +5V +5V +V B/A B/A A/B A/B C C U U V V W W 3 4 2 3 4 5 6 7 8 9 2 + SUB D 5 connector F F D D 2 3 4 3.7 3.7.3-3.6 3.6 Encoder impedance adaptation 3.24 3.22 Encoder supply voltage 3.23 Menu 2 Position Additional speed input 3.9 Encoder/frequency signal selection Number of points/rev. Phase control ( ) Lead/Lag ( ) Filter Disable ( ) ENCPH9 3.27 Ramp output speed reference 2. Encoder/frequency signal selection Speed reached reference.6 3.2 3.25 3.28 3.3 3.3 Menu Additional speed input selection 3.2 Final speed reference Encoder input speed Speed feedback 3.26.3.4 Resolver speed Menu 6 6.2 Zero speed Speed < F min Speed error 3. 3.3 D 3.2 3.2 Automatic resolver feedback selection Symbols Read and write Read only Read and assign Speed loop filter 3.3 P I 3. 3. Speed loop gains Zero speed threshold 3.5.7 Speed loop output 3.4 + 5 min Menu 4 -. Polarity selection 3.9 Speed reached alarm condition selection Overspeed reached " ovspd " Overspeed threshold 3.8 Speed <.5 alarm low threshold Speed >.7 alarm high threshold Speed reached alarm low threshold 3.6 Speed reached alarm high threshold 3.7 28

UMV 43 3.3 - Explanation of parameters in menu 3 Symbols : - open loop - closed loop 3.5 : Zero speed threshold Adjustment range : : to 2. Hz : to 2 min - - servo mode Factory setting : :. Hz 3. : Final speed reference : 5 min - Adjustment range : : ±. Hz : This parameter allows the final frequency reference to be read when the reference is given via a signal connected on the main encoder input. For all other operating modes 3. remains at. & : The final speed reference read represents the sum of the main speed reference at the end of the ramp and the additional speed input, if this is enabled. When the controller is locked, the final speed reference is at. 3.2 & : ± 3 min - : Speed feedback Adjustment range : ± 3 min - This parameter allows the actual speed to be read from either the motor encoder or from the RLV UMV option when a resolver is used as speed feedback. In the latter case, selection is automatic. : If motor frequency 5. is less than or equal to the level defined by this parameter, the zero speed alarm.3 is at, if not, it is at. & : If speed feedback 3.2 is less than or equal to the level defined by this parameter, the zero speed alarm.3 is at, if not, it is at. 3.6 : Speed reached alarm low threshold Adjustment range : : to. Hz Factory setting : : to 3 min - :. Hz : 5 min - Defines the lower limit for the speed reached alarm.. See parameter 3.9 for operation of the alarm. 3.7 : Speed reached alarm high threshold Adjustment range : : to. Hz 3.3 & : Speed error : to 3 min - Adjustment range : ± 3 min - The speed error is the difference between the final speed reference and the speed feedback after correction by the speed loop regulator. Factory setting : :. Hz : 5 min - 3.4 & : Speed loop output Adjustment range : ± current max limit. The speed loop output determines the torque reference required to define the active current. Defines the upper limit for the speed reached alarm. See parameter 3.9 for operation of the alarm. 29

UMV 43 3.8 : Overspeed threshold Adjustment range : : to. Hz : to 3 min - Increase the proportional gain until the motor vibrates, then reduce the value from 2 to 3 %, checking that the motor is stable on sudden variations of the speed reference, both at no-load and on-load. Factory setting : :. Hz : 2 min - : 4 min - Defines the frequency ( ) or the speed ( & ) above which the controller will trigger an overspeed fault. In open loop mode the adjustment of 3.8 is only effective if 3.29 =. 3.9 : Speed reached alarm condition selection Adjustment range : or Factory setting : This parameter is used to enable the frequency reached ( ) or speed reached ( & ) alarm signalled at parameter.6. The alarm can be controlled in 2 modes : : : frequency reached alarm.6 is at when 3. & : Speed loop integral gain Adjustment range : to 32 Factory setting : Controls motor speed stability on a load impact. Increase the integral gain to obtain the same on-load speed as at no-load on a load impact. 3.2 & : Speed loop derivative gain Adjustment range : to 32 Factory setting : In increments of. Controls motor speed stability when sudden reference variations occur or when the load is shed. Reduces speed overshoots. Normally, leave the setting at. 3.3 : Frequency tracking selection Adjustment range : or Factory setting : This parameter enables a reference signal connected on the main encoder input to be used as a reference. : Frequency tracking inhibited. : Frequency tracking enabled. (.3-3.6 ) < 5. < (.3 + 3.7 ). 3.4 : Scaling of frequency reference.6 is at when : speed reached alarm (.3-3.6 ) < 3.2 < (.3 + 3.7 ). : : frequency reached alarm.6 is at when 3.6 < 5. < 3.7..6 is at when : speed reached alarm 3.6 < 5. < 3.7. 3. & & & : Speed loop proportional gain Adjustment range : to 32 Factory setting : 2 Controls motor speed stability when sudden reference variations occur. 3.5 Adjustment range : 3.4 : to. 3.5 :. to. Factory setting :. The frequency reference from the encoder input can be scaled using the following formula : 3.4 3. = ( Encoder input frequency ) x ( ) 536 3.5 The encoder input frequency can be calculated using the formula : Speed of rotation F = 2 x x No. of encoder points 6 3.6 : Enable frequency output Adjustment range : or Factory setting : This parameter is used to enable the function which is used to obtain an image of the motor frequency on the main encoder input. This then becomes a frequency output. 3

UMV 43 3.7 3.8 : Output frequency adaptation Adjustment range : or Factory setting : 3.7 : 3.8 : Depending on the use required, the image of the output frequency can be multiplied by or 92 or 536 by combining parameters 3.7 & 3.8 as follows : : 3.9 : & Additional speed input Adjustment range : to the greater of.6 or.7 min - Factory setting : min - This additional speed input is an additional reference which is not assigned by the ramps. It can also be used as an error correction input when the synchronisation function (Menu 3) is used. 3.2 3.7 3.8 Ratio x x 92 x 536 x 536 & Adjustment range : or Factory setting : : Additional speed input inhibited. : Additional speed input enabled. : Additional speed input selection 3.2 : Number of points per encoder rev. Adjustment range : 256 to 496 Factory setting : : 24 : 496 The value of 3.2 depends on the maximum speed of the motor adjustable in.6 or.7. 3.2 maximum Max. permitted speed (min - ) 496-3 248 3-6 24 6-2 52 2-24 256 24-3 This parameter is used to configure the number of encoder points in the controller. An incorrect value for this parameter will result in incorrect reading of the motor speed and thus a controller malfunction. 3.22 : Encoder / frequency input selection Adjustment range : or Factory setting : : : : The reference is provided by an encoder (A, B) connected on the main encoder input. : The reference is provided by a Frequency/Direction signal (F, D) connected on the main encoder input. & : Speed feedback is provided by the motor encoder connected on the main encoder input or speed feedback is provided by a resolver connected on the RLV - UMV option and an encoder is used on the main input to provide an additional menu 3 function (synchro). : Speed feedback is provided by a resolver connected on the RLV - UMV option and a Frequency / Direction (F.D) signal is used on the main encoder input to provide an additional menu 3 function (Synchro etc). 3.23 : Encoder supply voltage selection Adjustment range : or Factory setting : : Supply voltage +5 V : Supply voltage +5 V. A +5 V supply voltage will destroy an encoder intended for use with a +5 V supply voltage. 3.24 : Encoder impedance adaptation Adjustment range : or Factory setting : When the encoder is connected to a single controller, the inputs should be loaded with a 2 Ω resistor in series with a nf capacitor. Where the encoder signal is used by several controller simultaneously, only the input of the furthest controller from the encoder must be loaded. : Encoder input charage activated. : Encoder input charage deactivated. 3.25 : Encoder phase control Adjustment range : or Factory setting : This test is used to check the phase lead/lag between the encoder (or the resolver) and the motor. In the case of an imbalance, the controller compensates automatically. The test must be performed on a machine at no-load by setting 3.25 to, releasing the controller and giving the start command. This parameter is automatically reset to when the test procedure has been completed. This test turns the motor at low speed for one motor revolution. Check that there is no risk of danger to people or equipment. 3

UMV 43 3.26 : Read encoder speed Adjustment range : ± 3 min - This parameter indicates the speed of the machine when the encoder is connected on the main encoder input. 3.27 : Read encoder position Adjustment range : to 6383/6384 revolutions This parameter indicates the encoder position connected on the main encoder input. The measurement is taken at the point where the encoder was positioned on powering up the controller. 3.28 : Encoder phase lead /lag Adjustment range : to 643/643 revolutions This parameter indicates the results of the encoder lead/lag test. It is memorised when the controller is powered down and is only modified when the lead/lag test is run again. Phase lead/lag can be entered manually but an incorrect value may cause the motor to turn in the wrong direction or a controller fault. 3.29 : Selection of the overspeed threshold Adjustment range : or Factory setting : ms : the overspeed threshold (forward or reverse) is the value set in.6 (or.7 ) + 2 %. : the overspeed threshold is as set in 3.8. 3.3 & : Filter on speed feedback window Adjustment range : to ms Factory setting : ms This parameter adjusts the width of the user window for the filter which has been added to the speed loop. This filter is used to minimise of the current drawn with a high inertia load and when a high gain is required on the speed loop. 3.3 : Disable ENC PH9 trip Adjustment range : or Factory setting : The ENC PH9 fault occurs when torque is applied with an incorrect sign and the motor is therefore subjected to uncontrolled acceleration. : Trip enabled : Trip disabled CAUTION : With some special configurations, the controller may suddenly trip on "ENC PH9", notably during very short accelerations with the motor under reduced load. If this occurs, disable the ENC PH9 trip. 32

UMV 43 4 - MENU 4 : CURRENT LOOP - TORQUE REGULATION 4. - List of Menu 4 parameters Parameter Description Type Mode Adjustment range Factory setting User setting 4. Total motor current RO to controller - - max. current (A) 4.2 Active motor current RO ± controller max current - - 4.3 Final torque reference RO ± % active In ( 5.7 x 5. ) - - 4.4 Current reference RO ± % active In - - 4.5 Motor current limit R/W & to max. active current 5.% (% active In) 75.% 4.6 Generator current limit R/W & to max. active current 5.% (% active In) 75.% 4.7 Symmetrical current limit R/W & to max. active current 5.% (% active In) 75.% 4.8 Torque reference R/W ± % active In 4.9 Torque offset R/W ± % active In 4. Torque offset selection R/W or 4. Torque regulation mode selection R/W or & to 4 4.2 Current loop filter R/W to 25 ms ms 2 4.3 Current loop proportional gain R/W to 3 5 3 4 4.4 Current loop integral gain R/W to 3 2 2 4.5 Motor thermal time constant R/W & to 4. s 89. s 7. s 4.6 Motor protection mode selection R/W or 4.7 Motor magnetising current RO ± controller max. current - - 4.8 Priority current limit RO to max. active current (%active In) - - 4.9 Overload integration RO to.% - - & 4.2 Selection of torque regulation mode RO ± % - - 33